共查询到20条相似文献,搜索用时 31 毫秒
1.
Angelica Stranieri Roberta Ferrari Sergio Zanzani Gabriele Rossi 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2016,45(2):225-228
A 13‐year‐old female Domestic Shorthair cat was presented to the Veterinary Teaching Hospital of the University of Milan for an interscapular mass suspected to be a mesenchymal malignant tumor. A preoperative CBC performed with Sysmex XT‐2000iV showed leukocytosis with neutrophilia and eosinophilia. The Sysmex WBC/DIFF scattergram showed an additional, well‐separated cluster of events between the neutrophil, eosinophil, and lymphocyte clusters. Blood smear evaluation revealed the presence of a significant number of basophils; thus, it was hypothesized that the additional cluster could represent the basophilic population. A second CBC, 24 days later, showed the same pattern on the WBC/DIFF scattergram in the absence of leukocytosis and neutrophilia. After surgical excision of the mass, a definitive diagnosis of feline injection site sarcoma was made. To the author's knowledge, there are no previous reports about the identification of feline basophils in the WBC/DIFF scattergram of Sysmex XT‐2000iV. 相似文献
2.
Harold Tvedten Päivi Johansson 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2010,39(2):190-192
Background: The large size of many feline platelets and the high frequency of platelet aggregation often results in falsely low platelet counts in this species. A combination of optical platelet counting to detect even large platelets and the use of prostaglandin E1 (PGE1) to inhibit platelet clumping may increase the accuracy of feline platelet counting. Objective: The objective of this study was to compare platelet counts in feline whole blood samples with and without the addition of PGE1 and using different analytical methods in a clinical setting. Methods: Platelet counts were determined in 10 feline patients in a referral veterinary hospital using 2 sample types (EDTA, EDTA with PGE1) and 2 methods of analysis (optical counting [PLT‐O] and impedance counting [PLT‐I]) on the Sysmex XT 2000 iV analyzer. Results: All PGE1–PLT‐O samples had platelet counts of >200 × 109/L. Mean platelet count using PGE1–PLT‐O (410,256±178 × 109/L) was significantly higher (P<.03) compared with PGE1–PLT‐I (256±113 × 109/L), EDTA–PLT‐O (238±107 × 109/L), and EDTA–PLT‐I (142±84 × 109/L) methods. Depending on the method, platelet counts in 2 to 7 of 10 cats were <200 × 109/L when PGE1‐PLT‐O was not used. A slightly increased platelet count in response to treatment of a feline patient with thrombocytopenia would have been missed without use of PGE1–PLT‐O. Conclusions: Using PLT‐O analysis on EDTA samples containing PGE1 provides higher, and therefore likely more accurate, feline platelet counts in a clinical setting. 相似文献
3.
Inger Lilliehöök Harold Tvedten 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2009,38(2):175-182
Background: The Sysmex XT‐2000iV is a laser‐based, flow cytometric hematology system that stains nucleic acids in leukocytes with a fluorescent dye. A 4‐part differential is obtained using side fluorescence light and laser side scatter. Objective: The purpose of this study was to validate the Sysmex XT‐2000iV for determining differential leukocyte counts in blood from ill dogs, cats, and horses. Methods: Blood samples from diseased animals (133 dogs, 65 cats, and 73 horses) were analyzed with the Sysmex XT‐2000iV (Auto‐diff) and the CELL‐DYN 3500. Manual differentials were obtained by counting 100 leukocytes in Wright‐stained blood smears. Results: Leukocyte populations in the Sysmex DIFF scattergram were usually well separated in equine samples, but were not as well separated in canine and feline samples. Correlation among the Sysmex XT‐2000iV, CELL‐DYN 3500, and manual counts was excellent for neutrophil counts (r ≥.97) and good for lymphocyte counts (r ≥.87) for all three species. Systematic differences between the 3 methods were seen for lymphocyte and monocyte counts. The Sysmex reported incomplete differential counts on 18% of feline, 13% of canine, and 3% of equine samples, often when a marked left shift (>10% bands) and/or toxic neutrophils were present. Eosinophils were readily identified in cytograms from all 3 species. Neither the Sysmex nor the CELL‐DYN detected basophils in the 7 dogs and 5 cats with basophilia. Conclusions: The Sysmex XT‐2000iV automated differential leukocyte count performed well with most samples from diseased dogs, cats, and horses. Basophils were not detected. Immature neutrophils or prominent toxic changes often induced errors in samples from cats and dogs. 相似文献
4.
5.
6.
Maria Elena Gelain Gabriele Rossi Luca Giori Stefano Comazzi Saverio Paltrinieri 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2010,39(2):169-179
Background: Classification of leukemias requires specialized diagnostic techniques. Automated preliminary indicators of neoplastic cells in blood would expedite selection of appropriate tests. Objective: The objective of this study was to assess the capacity of the Sysmex XT‐2000iV hematology analyzer to identify neoplastic cells in canine blood samples. Methods: Blood samples (n=160) were grouped into 5 categories: acute leukemia (n=30), chronic leukemia (n=15), neoplasia without blood involvement (n=41), non‐neoplastic reactive conditions (n=31), and healthy dogs (n=43). WBC counts, WBC flags, scattergrams, percentages of cells with high fluorescence intensity, and percentages of cells in the lysis‐resistant region were evaluated alone or in combination to establish a “leukemic flag.” Sensitivity, specificity, negative (LR?) and positive (LR+) likelihood ratios, and the number of false‐negative (FN) and false‐positive (FP) results were calculated, and receiver operating characteristic curves were designed for numerical values. Results: Among single measurements and parameters, only the evaluation of scattergrams minimized FN and FP results (sensitivity 100%, specificity 94.8%, LR+ 19.17, and LR? 0.00), although their interpretation was subjective. The more objective approach based on the generation of a “leukemic flag” had a sensitivity of 100%, specificity of 87.0%, LR? of 0.00, and LR+ of 7.67. Conclusion: Using a novel gating strategy the Sysmex XT‐2000iV may be used effectively to screen canine blood for hematopoietic neoplasia. 相似文献
7.
High diagnostic accuracy of the Sysmex XT‐2000iV delta total nucleated cells on effusions for feline infectious peritonitis 下载免费PDF全文
Alessia Giordano Angelica Stranieri Gabriele Rossi Saverio Paltrinieri 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2015,44(2):295-302
8.
Inger Lilliehöök Harold Tvedten 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2009,38(2):163-174
Background: The Sysmex XT‐2000iV is a laser‐based, flow cytometric hematology system that has been introduced for use in large and referral veterinary laboratories. Objective: The purpose of this study was to validate the Sysmex XT‐2000iV for counting erythrocytes, reticulocytes, platelets, and total leukocytes in blood from ill dogs, cats, and horses. Methods: Blood samples from diseased animals (133 dogs, 65 cats, and 73 horses) were analyzed with the Sysmex XT‐2000iV and the CELL‐DYN 3500. Manual reticulocyte counts were done on an additional 98 canine and 14 feline samples and manual platelet counts were done on an additional 73 feline and 55 canine samples, and compared with automated Sysmex results. Results: Hemoglobin concentration, RBC counts, and total WBC counts on the Sysmex were highly correlated with those from the CELL‐DYN (r≥0.98). Systematic differences occurred for MCV and HCT. MCHC was poorly correlated in all species (r=0.33–0.67). The Sysmex impedance platelet count in dogs was highly correlated with both the impedance count from the CELL‐DYN (r=0.99) and the optical platelet count from the Sysmex (r=0.98). The Sysmex optical platelet count included large platelets, such that in samples from cats, the results agreed better with manual platelet counts than with impedance platelet counts on the Sysmex. Canine reticulocyte counts on the Sysmex correlated well (r=0.90) with manual reticulocyte counts. Feline reticulocyte counts on the Sysmex correlated well with aggregate (r=0.86) but not punctate (r=0.50) reticulocyte counts. Conclusion: The Sysmex XT‐2000iV performed as well as the CELL‐DYN on blood samples from dogs, cats, and horses with a variety of hematologic abnormalities. In addition, the Sysmex detected large platelets and provided accurate reticulocyte counts. 相似文献
9.
Nazaré Pinto da Cunha Alessia Giordano Mario Caniatti Saverio Paltrinieri 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2009,38(2):230-241
Background: The Sysmex XT‐2000iV is a hematology analyzer that combines laser and impedance technology. Its usefulness for determining cell counts in canine and feline intracavitary effusions has not yet been studied. Objectives: The objectives of this study were to evaluate the analytical performance of the Sysmex XT‐2000iV for cell counts in effusions from dogs and cats, and to assess correlation with an impedance counter and concordance with diagnoses based on cytologic findings. Methods: Effusions (43 pleural, 23 peritoneal, 6 pericardial) were analyzed from 32 dogs and 34 cats. Total nucleated cell count (TNCC), HCT, and RBC count were determined on the Sysmex and compared with those obtained on an impedance counter (Hemat 8, SEAC). Imprecision, linearity, and limit of detection were determined for the Sysmex. An algorithm was designed using quantitative and qualitative data from the Sysmex to classify the effusions and the results were compared with diagnoses based on cytologic findings. Results: Intra‐assay and interassay coefficients of variation on the Sysmex were variable. Linearity of TNCC was ≥0.993 for dogs and cats, with the exception of effusions from cats with feline infectious peritonitis, which had delta (Δ) TNC values >3.0. In comparison with the Hemat 8, a proportional error was found for TNCC on the Sysmex. Effusion classification based on the algorithm was concordant with that obtained by cytologic examination in 43/72 (60%) samples. Discordant results usually were due to the misclassification of cells with similar morphology (such as mesothelial and carcinoma cells) in Sysmex scattergrams. Conclusion: The Sysmex XT‐2000iV provides a precise and accurate TNCC and has moderate concordance with cytologic findings for classifying canine and feline effusions. Although microscopic examination of effusions is necessary to achieve an accurate diagnosis, the Sysmex can provide preliminary information that may be helpful to cytopathologists. 相似文献
10.
11.
12.
Comparison of 4 point‐of‐care blood gas analyzers for arterial blood gas analysis in healthy dogs and dogs with cardiopulmonary disease 下载免费PDF全文
Elodie Roels DVM Kris Gommeren DVM DECVIM Frédéric Farnir Ir PhD François Delvaux MS Frédéric Billen DVM PhD DECVIM Cécile Clercx DVM PhD DECVIM 《Journal of Veterinary Emergency and Critical Care》2016,26(3):352-359
13.
Harr KE Raskin RE Heard DJ 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2005,34(4):383-388
BACKGROUND: Few studies have been done to evaluate anticoagulants for use with blood samples from birds and reptiles. Heparin currently is the most commonly used anticoagulant in practice, but may adversely affect blood cell staining and quantitation. OBJECTIVE: The purpose of this study was to evaluate the effects of lithium heparin, K3-EDTA, and sodium citrate, with and without the addition of albumin, on hematologic variables in macaw (Ara sp) and python (Python molurus bivittatus) blood samples. METHODS: Blood samples from 10 macaws and 10 Burmese pythons were collected in heparin-coated syringes and placed into tubes containing either lithium heparin, K3-EDTA, or sodium citrate with and without the addition of 0.25 mL of a 22% bovine serum albumin solution. Cell lysis was determined by counting the number of lysed cells/200 WBCs in Wright's-Giemsa-stained blood smears and by qualitative evaluation of pink plasma in microhematocrit tubes. A CBC was done after 3, 12, and 24 hours of storage at 4 degrees C in anticoagulant-containing tubes and results were compared with those obtained at 0 hour for the heparin-coated syringe sample. A biochemical panel also was done at each time point in similarly stored lithium-heparin samples. RESULTS: Hemolysis was significantly increased in citrated samples from both macaws and pythons beginning at 12 hours. At 24 hours, 19 of 30 (63%) macaw samples in all anticoagulants had >100 lysed cells/200 WBCs. There were no significant differences in hematologic values in samples from pythons collected in heparin or EDTA at any time point. No significant differences were found in the number of lysed cells or in other hematologic data in samples with albumin. Glucose concentration decreased and potassium concentration increased significantly over time in heparinized blood samples. CONCLUSIONS: Based on the results of this study, whole blood samples anticoagulated with lithium heparin or EDTA should be evaluated within 12 hours (macaws) or 24 hours (pythons) of collection and stored at 4 degrees C for best results. Citrate should be avoided as it may result in increased cell lysis. The addition of albumin does not prevent cell lysis. 相似文献
14.
L. Ferreira K. Lisenko B. Barros M. Zangeronimo L. Pereira R. Sousa 《Journal of animal physiology and animal nutrition》2014,98(1):1-8
The use of medium‐chain triglycerides (MCTs) has been studied for years in an attempt to elucidate their effects in food intake and body weight in animals. The aim of this study was to determine whether there is evidence that the use of MCT reduces consumption and body weight gain in rats, a species chosen as it has been widely used as an animal model in different surveys. A search of scientific work was performed in November 2011 on two bases: ‘Web of Science’ and ‘PubMed’. The terms sample size and homogeneity, randomisation, food consumption and weight gain, body composition, enzyme activity and hormonal activity in rats were used as selection criteria. Thirteen papers were selected after the refinement of the research. Twelve studies measured weight gain and among these, seven detected a decrease in weight gain and five found no differences. Twelve papers also measured food intake and among these, four detected a decrease in consumption, one detected an increase and seven found no differences. Based on established criteria for the ranking of scientific papers, it is concluded that there is strong evidence that MCTs can effectively reduce the consumption and subsequent weight gain of animals. However, in the long term, there may not be differences in results depending on the phenotypic adaptation of animals to a new metabolic condition. 相似文献
15.
16.
Identification of contaminant interferences which cause positive urine reagent test strip reactions in a cage setting for the laboratory‐housed nonhuman primate,Beagle dog,and Sprague–Dawley rat 下载免费PDF全文
William D. Siska Dennis J. Meyer Albert E. Schultze Catherine Brandoff 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2017,46(1):85-90
17.
18.
19.
Liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) for analysis of endogenous steroids in the luteal phase and early pregnancy in dogs: a pilot study 下载免费PDF全文
Bodil S. Holst Mark M. Kushnir Jonas Bergquist 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2015,44(4):552-558
20.
The Effect of Inadequate Presample Blood Volume Withdrawal from Intravenous Catheter and Extension Sets on Measured Circulating L‐Blood Lactate Concentration in Horses Receiving Lactated Ringer's Solution 下载免费PDF全文
F.J. Marqués S. Higgins R. Chapuis C. Waldner 《Journal of veterinary internal medicine / American College of Veterinary Internal Medicine》2017,31(1):51-54