共查询到20条相似文献,搜索用时 0 毫秒
1.
ROBERT T. O''BRIEN 《Veterinary radiology & ultrasound》2007,48(2):146-148
Three dogs with a splenic hemangiosarcoma were imaged with conventional gray-scale ultrasound and no lesions were identified in the liver. After administration of intravenous ultrasound contrast medium (Definity) small, poorly enhanced, hypoechoic nodules were identified in the liver in each dog. The spleen and liver lesions were identified at surgery and the dogs underwent splenectomy and nodule biopsy. All lesions were identified histologically as hemangiosarcoma. These preliminary results suggest that contrast ultrasound may result in improved detectability of metastatic hepatic hemangiosarcoma. 相似文献
2.
R.T. O''Brien DVM MS M. Iani DVM J. Matheson DVM F. Delaney BS K. Young VMD PhD 《Veterinary radiology & ultrasound》2004,45(6):547-553
Thirty-two dogs with spontaneous hepatic nodules were given intravenous ultrasound contrast medium (Definity or Sonovue) and imaged with contrast harmonic software on a conventional ultrasound machine system. Digital video images were initially reviewed to describe the perfusion pattern of malignant nodules. The images were reviewed again to test this pattern against all individual nodules. Subjectively, there was improved conspicuity of malignant nodules after contrast enhancement compared with conventional imaging and increased numbers of malignant nodules were often noted. There was decreased conspicuity of benign nodules and no additional nodules were seen after contrast enhancement. There was a highly significant (P < 0.0001) association of malignancy with a hypoechoic nodule at surrounding normal liver peak contrast enhancement. Benign nodules were isoechoic to the surrounding normal liver at peak contrast enhancement. Only one benign nodule (hepatoma) had regions of hypoechogenicity compared with the surrounding normal liver at peak liver contrast enhancement. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were highly significant (P < 0.0001) (100%, 94.1%, 93.8%, 100%, and 96.9%, respectively). No complications or morbidity was noted throughout the course of the study. Contrast harmonic ultrasound appears to be accurate at discriminating between naturally occurring benign and malignant nodules in the liver of dogs. 相似文献
3.
Susan M. Newell DVM MS Lisa Neuwirth DVM MS Pamela E. Ginn DVM Gregory D. Roberts DVM Linda S. Prime BS Jay M. Harrison 《Veterinary radiology & ultrasound》1998,39(4):332-336
The prostate gland of 11 normal dogs and five dogs with histological confirmed chronic lymphocytic or lymphoplasmocytic prostatitis were imaged with grey-scale and Doppler ultrasound. Three vessel types (prostatic artery, capsular artery and parenchymal artery) were identified with color Doppler and the resistive index and maximum and minimum velocities were measured with pulsed wave Doppler. No differences between normal dogs and dogs with prostatitis was identified in either grey-scale ultrasound or in any Doppler parameters measured. Regardless of histologic diagnosis, acepromazine (0.05 mg/kg IV) caused a significant decrease in capsular artery maximum and minimum velocities and prostatic artery resistive index. This study establishes normal Doppler ultrasound parameters for the intact male canine prostate gland. Additional studies are necessary to further evaluate the clinical utility of Doppler ultrasound in canine prostatic diseases. 相似文献
4.
Olivier Taeymans Dominique G. Penninck Rachel M. Peters 《Veterinary radiology & ultrasound》2013,54(1):61-70
This study compares clinical, ultrasound, computed tomography (CT), magnetic resonance imaging (MRI), and pathology findings in 16 prospectively, and seven retrospectively recruited dogs presented for suspected thyroid carcinoma. Of these, 17 were confirmed thyroid carcinoma, while six were initially misdiagnosed. These included four carotid body tumors, one para‐esophageal abscess, and one undifferentiated squamous cell carcinoma. Thyroid carcinomas occurred in older dogs without evidence of sex predilection, and were more often unilateral. All were large, heterogeneous, moderately to strongly vascularized, and most commonly contained areas of dystrophic mineralization and/or fluid accumulations. On MRI, thyroid carcinomas appeared hyperintense compared to surrounding musculature in all imaging sequences used, while on CT they had a lower attenuation value than normal thyroid gland tissue. Histologically confirmed tumor capsule disruption with invasion of the surrounding structures was most commonly detected with MRI. Palpation was not an accurate predictor of locally invasive vs. well‐encapsulated masses. Computed tomography had the highest specificity (100%) and MRI had the highest sensitivity (93%) in diagnosing thyroid carcinoma, while ultrasound had considerably lower results. We conclude that ultrasound is adequate for use as a screening tool for dogs with suspected thyroid carcinoma, but recommend either CT or MRI for preoperative diagnosis and staging. 相似文献
5.
Anne Bahr DVM Robert Wrigley BVSc MS DVR Mowafak Salman BVMS PhD 《Veterinary radiology & ultrasound》2000,41(1):50-55
Diagnostic ultrasound currently provides a noninvasive, economical means to evaluate internal organ structure. Methods to increase the amount of diagnostic information obtained from the sonographic examination are being explored. A new area of research has recently focused on the ability of microbubble contrast agents to help provide additional information. A prospective study was undertaken to quantitatively evaluate the amount of gray scale enhancement of ultrasound images of six canine livers, spleens, and left kidneys that occurs after intravenous injection of Imagent. Computerized analysis was used to assess the percent change in brightness of these images. A transient decrease in the percent change in brightness was seen to occur after injection of higher doses of Imagent. This effect was more pronounced in the deeper portions of the organs of interest. Imagent provides a measurable change in the brightness of the organs of interest and would be potentially useful in a clinical setting. 相似文献
6.
INCIDENTAL AND NONINCIDENTAL CANINE THYROID TUMORS ASSESSED BY MULTIDETECTOR ROW COMPUTED TOMOGRAPHY: A SINGLE‐CENTRE CROSS SECTIONAL STUDY IN 4520 DOGS 下载免费PDF全文
Giovanna Bertolini Michele Drigo Luca Angeloni Marco Caldin 《Veterinary radiology & ultrasound》2017,58(3):304-314
Thyroid nodules are common in dogs and are increasingly likely to be detected with the increased use of advanced imaging modalities. An unsuspected, nonpalpable, asymptomatic lesion, defined as a thyroid incidentaloma, may be discovered on an imaging study unrelated to the thyroid gland. The objective of this single‐center cross‐sectional study was to assess the prevalence and computed tomography (CT) characteristics of incidental and nonincidental thyroid tumors in a large population of dogs, using prospective recruitment of patients undergoing CT examination for various reasons during the period of 2005–2015. Unilateral or bilateral thyroid masses were detected in 96/4520 dogs (prevalence, 2.12%; 95% confidence interval [CI], 1.70–2.54%). Seventy‐nine (82.3%) lesions were malignant and 17 (17.7%) were benign. Masses were discovered incidentally in 34/96 dogs (overall prevalence of incidentaloma, 0.76%; 95% CI, 0.51–1.02), and 24 (70.6%) of these 34 masses were thyroid carcinomas. Among the CT variables assessed, mineralization, vascular invasion, and tissue invasion were detected only in malignant tumors. Intratumoral vascularization was significantly associated with the presence of thyroid malignancy (P < 0.001). Although incidental thyroid nodules in dogs are relatively rare, they are often malignant. Findings indicated that the neck should be thoroughly assessed in middle‐aged and old patients undergoing body CT for various reasons. Thyroid nodules detected incidentally on CT should be sampled to avoid missing thyroid cancer. 相似文献
7.
Mauro Pivetta Luisa De Risio Richard Newton Ruth Dennis 《Veterinary radiology & ultrasound》2013,54(5):516-521
Asymmetry of the cerebral lateral ventricles is a common finding in cross‐sectional imaging of otherwise normal canine brains and has been assumed to be incidental. The purpose of this retrospective study was to compare the prevalence of ventricular asymmetry in brain MRI studies of normal dogs and dogs with idiopathic epilepsy. Brain MRI archives were searched for 100 neurologically normal dogs (Group 1) and 100 dogs with idiopathic epilepsy (Group 2). For each dog, asymmetry of the lateral ventricles was subjectively classified as absent, mild, moderate, and severe based on a consensus of two observers who were unaware of group status. Ventricular areas were measured from transverse T1W images at the level of the interthalamic adhesion. An asymmetry ratio was calculated as the ratio of the larger to smaller ventricular transverse area. There was excellent agreement between subjective assessments of ventricular asymmetry and quantitative assessments using asymmetry ratios (k = 0.995). The prevalence of asymmetry was 38% in Group 1 dogs and 44% in Group 2 dogs. Assymmetry was scored as mild in the majority of Group 2 dogs. There was no significant association between presence/absence and degree of ventricular asymmetry vs. dog group, age, gender, or skull conformation. Findings from the current study supported previously published assumptions that asymmetry of the lateral cerebral ventricles is an incidental finding in MRI studies of the canine brain. 相似文献
8.
Fern Delaney RDMS Robert T. O''Brien DVM MS Ken Waller BS 《Veterinary radiology & ultrasound》2003,44(5):577-580
The use of ultrasound to measure small bowel thickness is an important part of any ultrasound examination of the abdomen. Increased thickness of the intestinal wall is a hallmark for the detection of diseases ranging from inflammatory bowel disease to neoplasia. Our subjective impression has been that dogs with no clinical signs of gastrointestinal disease often have sonographic measurements greater than published norms. The purpose of this study was to prospectively reevaluate these norms. The clinical history on all dogs receiving an abdominal ultrasound examination was evaluated for signs of gastrointestinal disease. Those without clinical signs were entered into this study. The documentation of body weight, breed, jejunal thickness, and duodenal thickness was made in 231 dogs. Dogs were placed into five groups based on their weight. Sixty-nine breeds were represented with weight ranging from 2.1 to 64 kg. A statistically significant (P < or = 0.05) correlation between body weight and both jejunal and duodenal thickness was observed. We also found that the maximum thickness in both jejunum and duodenum in healthy dogs was larger than previously reported. These data indicate norms for the jejunum of < or = 4.1 mm for dogs up to 20 kg, < or = 4.4 mm for dogs between 20 and 39.9 kg, and < or = 4.7 mm for dogs over 40 kg. The data indicate norms for the duodenum < or = 5.1 mm for dogs up to 20 kg, < or = 5.3 kg for dogs between 20 and 29.9 kg, and < or = 6.0 mm for dogs over 30 kg. 相似文献
9.
KENNETH R. WALLER ROBERT T. O''BRIEN JAMES A. ZAGZEBSKI 《Veterinary radiology & ultrasound》2007,48(4):373-377
Eight normal dogs with no evidence of renal disease, weighing between 8 and 25 kg were imaged using contrast harmonic ultrasound after injection of a microbubble contrast medium. All dogs received three separate bolus injections of 0.05 ml of commercial contrast medium (Definity). Time/mean pixel value (MPV) curves were generated for selected regions in the cortex and medulla of the left kidney in each dog. Upslope, downslope, baseline, peak intensity, and time to peak were calculated for each zone. For a bolus injection, within the renal cortex (averaging all subjects) the upslope was 7.4 +/- 1.5 MPV/s, downslope was -0.4 +/- .2 MPV/s, baseline was 66.8 +/- 9.3 MPV, peak was 103.6 +/- 8.2 MPV, time to peak (from injection) was 12.8 +/- 5.3 s and from time of contrast medium reaching the kidney was 5.1 +/- 2.0 s. Within the renal medulla (averaging all subjects), upslope was 2.8 +/- 1.7 MPV/s, downslope was -0.3 +/- .2 MPV/s, baseline was 39.3 +/- 6.0 MPV, peak was 65.2 +/- 14.3 MPV, time to peak from injection was 20.9 +/- 6.4 s and from time of contrast reaching the kidney was 11.6 +/- 4.1 s. These baseline data may prove useful in the evaluation of dogs with diffuse disease or vascular compromise. 相似文献
10.
SOFIJA R. LILES KEITH E. LINDER BRANDON CAIN ANTHONY P. PEASE 《Veterinary radiology & ultrasound》2010,51(4):447-452
The purpose of this study is to characterize the sonographic appearance of canine parathyroid glands using high‐resolution ultrasonography. Ten cadaver dogs were studied after euthanasia for reasons not relating to the parathyroid. The cervical region was examined using a 13–5 MHz linear transducer in right and left recumbency. Ultrasonographic features of the parathyroid and thyroid glands were compared with the gross and histopathologic findings. Thirty‐five structures were identified sonographically as parathyroid glands but only 26 of 35 glands (74% positive predictive value) were proven to be normal parathyroid glands histopathologically. Of the nine false positives, five (14%) were proven to be lobular thyroid tissue. The remaining four (11%) structures were visible grossly or found histopathologically. There were no statistical differences between ultrasonographic and gross measurements of the parathyroid glands. The average size as seen sonographically was 3.3 × 2.2 × 1.7 mm and the average gross size was 3.7 × 2.6 × 1.6 mm (length, width, height). The average size of the thyroid lobules assessed sonographically was 2.3 × 1.6 × 0.8 mm (length, width, height). Normal parathyroid glands can be identified using high‐resolution ultrasonography. But some thyroid lobules will be misinterpreted as parathyroid glands; this will result in false positives when identifying parathyroid glands with ultrasonography. 相似文献
11.
Rochelle M. Salwei Robert T. O''Brien Jodi S. Matheson 《Veterinary radiology & ultrasound》2005,46(5):411-416
Doppler ultrasound has been used in humans to determine angioarchitecture of lymph nodes as the criterion for the determination of malignancy. We hypothesized that the vascular and perfusion patterns of a canine malignant lymph node could be characterized with intravenous microbubble ultrasound contrast media and that contrast harmonic ultrasound could provide better conspicuity of the angioarchitecture when compared with Power Doppler ultrasound. In this study, 11 peripheral lymph nodes in dogs with histologically verified malignant lymphoma were imaged with fundamental ultrasound, Power Doppler ultrasound, and three contrast harmonic pulse sequences to characterize the vascular pattern and perfusion. Vascular imaging was greatly enhanced in these nodes with 2.13 times more vessels seen with contrast harmonic ultrasound compared with Power Doppler ultrasound (P < 0.01). The angioarchitecture of lymphomatous lymph nodes of dogs in this study were similar to those previously described in malignant superficial lymph nodes in human patients; 45.5% of the nodes had displacement of the central hilar vessel, 45.5% had aberrant vessels, 63.6% had pericapsular vessels, 36.4% had subcapsular vessels, and 81.8% had loss of the central hyperechoic band in fundamental sonography. Poor perfusion, indicated by a lower mean pixel intensity increase between pre- and postcontrast administration images, was seen in 36.4% of the lymph nodes while 63.6% had fair to good perfusion. The perfusion patterns in nine of the 11 lymph nodes were homogenous and two showed focal hypoperfused regions. We conclude that Power Doppler and contrast harmonic ultrasound are beneficial in accurately depicting angioarchitechture and can provide additional information in determining the presence of malignant vascular characteristics within lymphomatous nodes in dogs. 相似文献
12.
Simonetta Citi Tommaso Chimenti Veronica Marchetti Francesca Millanta Tommaso Mannucci 《Veterinary radiology & ultrasound》2013,54(6):646-651
Micronodular ultrasound lesions have been detected in the colonic submucosa of dogs and cats at our hospital. The lesions had rounded/oval shapes, measured 1–3 mm in size, and exhibited a hypo/anechoic ultrasonographic pattern. To our knowledge, these lesions have not been previously reported in human or veterinary patients. The purpose of this retrospective study was to determine whether micronodular lesions were associated with other abdominal ultrasound abnormalities or clinical findings. Medical records of dogs and cats with sonographic reports describing micronodular lesions within the colonic submucosa were reviewed. Concurrent ultrasonographic abnormalities were recorded and compared with clinical sidgns and follow‐up data. A total of 42 dogs and 14 cats met inclusion criteria. Concurrent sonographic abnormalities included the following: increased colon wall thickness (12.5%); small bowel wall thickening, altered layering, and/or hyperechoic mucosa (45%); abdominal effusion (29%); caudal mesenteric lymphadenopathy (46%); mesenteric lymphadenopathy (27%); and pericolic peritoneal fat reactivity (9%). Fifty of 56 animals presented with diarrhea. Twenty‐seven cases had clinical signs of colitis and ultrasonographic lesions were limited to the colonic submucosa. In nine cases, follow‐up examination at 6–8 weeks showed resolution of clinical and ultrasonographic signs. Ultrasonographic and clinical examinations in 17 patients at 12–18 months and in 20 patients at 18–30 months from initial diagnosis showed resolution of submucosal lesions and clinical signs of enteropathy. The authors propose that micronodular submucosal ultrasound lesions may represent reactive intraparietal lymphoid follicles and may be indicators of colonic inflammatory diseases in dogs and cats. 相似文献
13.
Rochelle M. Salwei DVM Robert T. O''Brien DVM MS Jodi S. Matheson DVM 《Veterinary radiology & ultrasound》2003,44(3):301-305
Contrast harmonic ultrasound was used to determine macrovascular and perfusion patterns in three dogs with congenital extrahepatic solitary portosystemic shunts (PSS). With coded harmonic angiographic ultrasound, the size and tortuosity of the hepatic arteries were subjectively increased. Single pulse intermittent low-amplitude harmonic perfusion imaging provided contrast enhancement time-intensity curves from regions of interest in the liver. Mean (+/- standard deviation) peak perfusion times of dogs with PSS were significantly shorter (p = 0.01; 7.0 +/- 2.0 s) than reported in normal dogs (22.8 +/- 6.8 s). The contrast inflow slope for the dogs with PSS (14.6 +/- 3.7 pixel intensity units [PIU] was significantly (p = 0.05) larger than reported for normal dogs (3.6 +/- 1.4 PIU/s). These results indicate that combined coded harmonic angiographic and contrast harmonic perfusion sonography can be used to detect increased hepatic arterial blood flow as an indicator of PSS in dogs. 相似文献
14.
Giovanna Bertolini Alessia Diana Mario Cipone Michele Drigo Marco Caldin 《Veterinary radiology & ultrasound》2014,55(5):521-530
Caudal vena cava duplication has been rarely reported in small animals. The purpose of this retrospective study was to describe characteristics of duplicated caudal vena cava in a large group of dogs. Computed tomography (CT) and ultrasound databases from two hospitals were searched for canine reports having the diagnosis “double caudal vena cava.” One observer reviewed CT images for 71 dogs and two observers reviewed ultrasound images for 21 dogs. In all CT cases, the duplication comprised two vessels that were bilaterally symmetrical and approximately the same calibre (similar to Type I complete duplication in humans). In all ultrasound cases, the duplicated caudal vena cava appeared as a distinct vessel running on the left side of the abdominal segment of the descending aorta and extending from the left common iliac vein to the left renal vein. The prevalence of caudal vena cava duplication was 0.46% for canine ultrasound studies and 2.08% for canine CT studies performed at these hospitals. Median body weight for affected dogs was significantly lower than that of unaffected dogs (P < 0.0001). Breeds with increased risk for duplicated caudal vena cava were Yorkshire Terrier (odds ratio [OR] = 6.41), Poodle (OR = 7.46), West Highland White Terrier (OR = 6.33), and Maltese (OR = 3.87). Presence of a duplicated caudal vena cava was significantly associated with presence of extrahepatic portosystemic shunt(s) (P < 0.004). While uncommon in dogs, caudal vena cava duplication should be differentiated from other vascular anomalies when planning surgeries and for avoiding misdiagnoses. 相似文献
15.
PABLO GÓMEZ‐OCHOA FRANCISCO LLABRÉS‐DÍAZ SERGIO RUIZ ANDREA CORDA SAUL PRIETO IVÁN SOSA TOMMASO GREGORI MANUEL GASCÓN 《Veterinary radiology & ultrasound》2010,51(5):523-526
Portosystemic shunts (PSSs) allow portal blood to bypass the liver and enter the systemic circulation. Definitive diagnosis requires surgical identification, positive contrast portography, ultrasonography, or scintigraphy. This study was designed as a preliminary step to developing an alternative/adjuvant protocol to these imaging modalities. The main goals were to establish a technique for ultrasound‐guided percutaneous trans‐splenic injection of agitated saline, to evaluate the feasibility of performing the test to explore the postsplenic portal vasculature highlighted by the microbubbles, and to ascertain whether agitated saline microbubbles cross the sinusoidal barrier. Agitated saline was injected into the spleen of 20 healthy sedated dogs under sonographic guidance. The transducer was then repositioned to visualize the portal vein, the caudal vena cava, and the right atrium through different acoustic windows. Satisfactory results were achieved in all dogs. The microbubbles were visualized in all dogs as small intense echo signals within the portal vein at the level of the porta hepatis immediately after injection. In 18 out of 20 dogs, the echogenic signal of the microbubbles disappeared immediately once within the hepatic parenchyma, whereas in two dogs, the echoes from the microbubbles lasted for several seconds within the intrahepatic portal vasculature. The absence of microbubbles beyond the sinusoidal barrier in all of the healthy dogs included in this study makes trans‐splenic injection of agitated saline a candidate as an adjuvant technique for the diagnosis of PSS, being easy to perform and repeat, as well as safe and technically feasible. 相似文献
16.
William P. Thomas DVM David Sisson DVM Timothy G. Bauer DVM John R. Reed DVM 《Veterinary radiology & ultrasound》1984,25(2):65-72
From a two-year review of diagnostic two-dimensional real-time echocardiographic studies, a diagnosis of cardiac mass lesion was made in 18 dogs. Thirteen of 18 also had pericardial effusion. Three types of lesions were identified: (1) right atrial masses (7 dogs; 5 confirmed as hemangiosarcoma) originating from the wall of the right atrium of right auricle and projecting into the atrial lumen, pericardial space, or both; (2) large cavitary pericardial masses (2 dogs; both confirmed as abscesses) located over the right ventricle; (3) heartbase masses (9 dogs; 6 confirmed as neoplasms) attached to the ascending aorta, with varying degrees of infiltration of heartbase structures. Although extrapericardial portions of the masses were not outlined as well as intrapericardial portions, surgical accessibility was correctly predicted in most dogs. It was concluded that two-dimensional echocardiography (2DE), performed systematically using multiple imaging planes, allowed accurate detection and localization of cardiac and pericardial masses in dogs and was useful in predicting surgical accessibility of these lesions. 相似文献
17.
Rachel Lande Shona L. Reese Laura C. Cuddy Clifford R. Berry Antonio Pozzi 《Veterinary radiology & ultrasound》2014,55(1):23-28
Osteochondrosis is a common developmental abnormality affecting the subchondral bone of immature, large breed dogs. The purpose of this retrospective study was to describe CT lesions detected in scapulohumeral joints of 32 immature dogs undergoing CT for thoracic limb lameness. Eight dogs (14 scapulohumeral joints) had arthroscopy following imaging. Thirteen dogs (19 scapulohumeral joints) were found to have CT lesions, including 10 dogs (16 scapulohumeral joints) with subchondral bone lesions and 3 dogs with enthesopathy of the supraspinatus tendon. In one dog, subchondral bone lesions appeared as large oval defects within the mid‐aspect of the glenoid cavities, bilaterally. These lesions resembled osseous cyst‐like lesions commonly identified in the horse. This is the first report of such a presentation of a subchondral bone lesion in the glenoid cavity of a dog. In all dogs, small, focal, round or linear lucent defects were visible within the cortical bone at the junction of the greater tubercle and intertubercular groove. These structures were thought to represent vascular channels. Findings from this study support the use of CT as an adjunct modality for the identification and characterization of scapulohumeral subchondral bone lesions in immature dogs with thoracic limb lameness. 相似文献
18.
William H. Adams DVM Michael A. Walker DVM Gregory B. Daniel DVM MS Mark G. Petersen DVM MA Alfred M. Legendre DVM MS 《Veterinary radiology & ultrasound》1995,36(5):417-424
Seven dogs with thyroid gland carcinoma were treated with 131 I and hormone suppressive therapy either alone (3 dogs) or in combination with surgery (3 dogs) or 137 Cs teletherapy and chemotherapy (1 dog). Empirically chosen doses of 75 to 137 mCi of 131 I were given orally (2 dogs) and intravenously (5 dogs). Adverse effects were limited to acute, transient bone marrow hypoplasia and pancytopenia. Nominal objective reduction in tumor volume or size and number of pulmonary metastases was observed in 4 dogs treated with 131 I and thyroxine. Of these 4 dogs, 2 had stable disease for periods of 4 and 12 months while a third dog had stable disease for 27 months following two 131 I treatments at 3 month intervals. The fourth dog had progressive disease. Two dogs with mediastinal metastases showed reduction in localization of 99m Tc pertechnetate and radioiodine following 2 and 3 treatments using 131 I. It appears that relatively high doses of 131 I can be used safely for the treatment of canine thyroid tumors and that further investigation can be justified to define its efficacy. 相似文献
19.
A tibial tuberosity radiolucency is sometimes identified on lateral radiographs of canine stifle joints, however little is known about the cause or significance. The purpose of this study was to describe the prevalence, association with other stifle conditions, and histopathologic characteristics of tibial tuberosity radiolucencies in a group of dogs. Radiographs of all canine stifle joints over 5 years were evaluated. Presence or absence of a tibial tuberosity radiolucency was recorded by an observer who was unaware of clinical status. Patient signalment and presence of other stifle joint conditions were recorded from medical records. A tibial tuberosity radiolucency was found in 145/675 dogs (prevalence = 21.5%). Statistically significant associations were identified between tibial tuberosity radiolucency and stifle condition (P < 0.0001), breed size (P = 0.011), and younger age of presentation (P = 0.001), but not with gender (P = 0.513). Dogs with a tibial tuberosity radiolucency had higher odds of having a medial patellar luxation than dogs without (OR = 9.854, P < 0.0001, 95% CI 6.422–15.120). Dogs with a tibial tuberosity radiolucency had lower odds of having a cranial cruciate ligament rupture than dogs without (OR = 0.418, P < 0.0001, 95% CI 0.287–0.609). Four canine cadavers, two with normal stifles and two with tibial tuberosity radiolucencies, underwent radiographic, computed tomographic, and histologic examination of the stifles. Computed tomography revealed a hypoattenuating cortical defect in the lateral aspect of the proximal tibial tuberosity that corresponded histopathologically to a hyaline cartilage core. Findings indicated that the tibial tuberosity radiolucency may be due to a retained cartilage core and associated with medial patellar luxation in dogs. 相似文献
20.
PREVALENCE OF EAR DISEASE IN DOGS UNDERGOING MULTIDETECTOR THIN‐SLICE COMPUTED TOMOGRAPHY OF THE HEAD 下载免费PDF全文
Previous reports describing the prevalence of ear diseases in dogs have primarily been based on dogs presenting with clinical signs of disease. The prevalence of subclinical ear disease remains unknown. The purpose of this cross‐sectional retrospective study was to describe the prevalence of lesions consistent with middle and external ear disease in dogs presented for multidetector computed tomography (CT) of the head and/or cranial cervical spine at our hospital during the period of July 2011 and August 2013. For each included dog, data recorded were signalment, CT findings, diagnosis, and treatment. A total of 199 dogs met inclusion criteria. Nineteen dogs (9.5%) were referred for evaluation of suspected ear disease and 27 dogs (13.5%) had histories or physical examination findings consistent with otitis externa. A total of 163 dogs (81.9%) had CT lesions consistent with external ear disease (i.e. ear canal mineralization, external canal thickening, and/or narrowing of the external canal). Thirty‐nine dogs (19.5%) had CT lesions consistent with middle ear disease (i.e. soft tissue attenuating/fluid material in the tympanic bullae, bulla wall thickening or lysis, and/or periosteal proliferation of the temporal bone). Findings from this study indicated that the prevalence of external and middle ear disease in dogs could be higher than that previously reported. 相似文献