首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 562 毫秒
1.
In human beings, intrarenal blood flow impedance, expressed as the resistive index (Rl) and obtained by duplex Doppler ultrasonography, has been used to aid in diagnosis and prognosis of renal failure. Higher than normal values for Rl were obtained in 3 of 4 dogs with acute tubular necrosis (ATN) and in 5 of 10 dogs with glomerulonephrosis (GN). Normalization of Rl was observed in 2 dogs with ATN evaluated serially during treatment. Increased Rl values were obtained in 9 of 10 cats with nonobstructive renal disease and in 2 of 5 cats with obstructive renal disease. Normalization of Rl was observed in 3 cats with renal failure in which treatment was effective (1 with obstruction; 2 with nonobstructive disease). The magnitude of increase in Rl did not correlate with the magnitude of concurrent renal dysfunction. These results suggest that duplex Doppler evaluation of intrarenal Rl is more useful as an ancillary diagnostic technique in azotemic dogs with ATN than in those with GN and in azotemic cats with nonobstructive than in those with obstructive disease.  相似文献   

2.
Resistive index (RI) and pulsatility index (PI) are indirect measurements of blood flow resistance that may be used to evaluate vascular changes in renal and ophthalmologic diseases. To our knowledge, no reports are available describing values for renal and ocular PI index in the unsedated dog and ocular RI and PI indices in the unsedated cat. The purpose of this study was to measure normal values for both intrarenal and ocular RI and PI within the same subject in unsedated clinically normal dogs and cats. Twenty-seven dogs and 10 cats were considered healthy by means of physical examination, CBC, biochemical profile, urinalysis, and ultrasonography. Systolic blood pressure was measured by Doppler ultrasonography. Intrarenal and ocular arteries were scanned by pulsed Doppler ultrasonography to calculate RI and PI. No significant differences were noted between the values obtained for the right vs. the left kidney and eye. The upper values of these indices were calculated as mean+2 standard deviations resulting in 0.72 and 1.52 for dog renal RI and PI; 0.7 and 1.29 for cat renal RI and PI; 0.76 and 1.68 for dog ocular RI and PI; and 0.72 and 1.02 for cat ocular RI and PI.  相似文献   

3.
The feasibility and reproducibility of obtaining the pulsed-wave Doppler measurements of resistive index (RI) and pulsatility index (PI) were investigated in intrarenal arteries of normal, nonsedated cats, and cats anesthetized with isoflurane. In addition, relative renal function and relative renal blood flow were evaluated using quantitative renal scintigraphy. The percentage of injected dose uptake, time to peak activity, and two indices of renal blood flow (K/A ratio and flow index) obtained during the first pass of 99mTc-MAG3, were determined for both awake and anesthetized cats. Results indicate that measuring RI and PI in nonsedated cats is readily accomplished and that the results are reproducible within an animal. Mean RI and PI values in the awake cats were 0.55 and 0.8, respectively. Significant differences between the awake and anesthetized cats were found for all pulsed-wave Doppler and quantitative renal scintigraphic measurements evaluated.  相似文献   

4.
Abnormal intrarenal flow In a seven-year old female Tibetan terrier with Addison's disease was demonstrated by duplex Doppler examination. Abnormal flow may reflect renal vasoconstriction due to increased activity of the renin-anglotensln system. Although not pathognomonic, an Increased resistive Index (< 0 - 70) In an otherwise ultrasonographically normal kidney can be due to Addison's disease and the technique may prove valuable as a quick non-Invasive tool In the management of this disease.  相似文献   

5.
OBJECTIVE: To determine scintigraphic, sonographic, and histologic changes associated with renal autotransplantation in cats. ANIMALS: 7 adult specific-pathogen-free cats: 5 males, 2 females, 1 to 9 years old. PROCEDURE: Renal autotransplantation was performed by moving a kidney (5 left, 2 right) to the left iliac fossa. Before and at multiple times after surgery, for a total of 28 days, cats were evaluated by B-mode and Doppler ultrasonography, scintigraphy, and renal biopsy. RESULTS: By 24 hours after surgery, a significant decrease (42%) in mean glomerular filtration rate (GFR) and an increase in mean renal size (81% increase in cross-sectional area) were evident in the transplanted kidney, compared with preoperative values. By postsurgery day 28, reduction in GFR was 23%. Significant changes in renal blood flow velocity were identified in both kidneys. Consistent changes in resistive index or pulsatility index for either kidney could not be identified. When all postoperative histologic data were combined, the histologic score, indicating degree and numbers of abnormalities detected, for the transplanted kidney was significantly higher than that for the control kidney. CONCLUSIONS: Significant changes in renal function, size, and histologic abnormalities develop secondary to acute tubular necrosis in cats after uncomplicated renal autotransplantation. CLINICAL RELEVANCE: Evaluation of renal size and function may be of benefit for clinical evaluation of feline renal transplant patients, whereas measurement of the resistive index may be of little clinical value.  相似文献   

6.
Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n=50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17±13.46 cm/s and 0.38±0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15±0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17±9.40 cm/s and 0.54±0.07. The RA had a mean ESA of 1.12±1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828±0.296. The IA showed PSV and RI values of 32.16±9.33 cm/s and 0.52±0.06, respectively. The mean ESA of all IAs was 0.73±0.61 m/s(2). The calculated upper limit of the reference value was 2.0m/s(2). The mean renal-interlobar artery ratio was 1.45±0.57. The RI values obtained in this study were similar to values reported in the literature. Some conditions that lead to a decrease in compliance and to an increase in vascular resistance can affect the Doppler spectral waveforms without changes in RI. To our knowledge, there are no studies that were directed toward to the normal ESA values of the renal vasculature in Persian cats. This study introduced a new ratio between the PSV of the RA and the IA. This index was developed based on the well-known effects of Doppler on the detection of stenosis, regardless of the cause. Further studies are necessary to verify the hemodynamic behavior of this index under pathological conditions in cats as well as the effect of aging, nephropathies and systemic pressure on Doppler velocimetric parameters.  相似文献   

7.
This study was performed to validate the procedure of transarterial embolization of the renal artery (TAE-RA) using iohexol-ethanol solution in rabbits with unilateral experimental hydronephrosis and to evaluate the embolized kidney and contralateral normal kidney using B-mode ultrasonography and color Doppler ultrasonography. Experimental hydronephrosis was induced at 17 days after ligation of unilateral ureter in 13 rabbits. Renal artery embolization was performed using selective catheterization in the hydronephrotic kidney of eight rabbits and electrocardiography, oxygen saturation, body temperature, pulse, and respiratory rate were within normal ranges during procedures. Iohexol-ethanol solution was used as embolic material. Average ethanol dose for renal artery embolization was 1.4 +/- 0.7 ml/kg. There were no rabbits expired after TAE-RA and no side effects associated with regurgitation of iohexol-ethanol solution. In color Doppler ultrasonographic findings, there was no blood flow into the embolized kidneys treated by TAE-RA, however, blood flow signal was found in hydronephrotic kidney not treated by TAE-RA. Ultrasonographically, the mean longitudinal length of the embolized kidney significantly decreased at 2 and 3 months after TAE-RA. No significant difference of resistive index values was found between contralateral normal kidney of rabbits treated by TAE-RA and contralateral normal kidneys of rabbits treated with nephrectomy. We may conclude that TAE-RA with iohexol-ethanol solution is a viable alternative to nephrectomy in rabbits with unilateral hydronephrosis.  相似文献   

8.
OBJECTIVES: To determine blood flow velocities and indices from spectral waveforms obtained by use of Doppler ultrasonography of thoracic limb arteries of horses and to assess interobserver and patient variability associated with the technique. ANIMALS: 9 clinically normal adult horses. PROCEDURE: Left thoracic limb arteries of 8 nonsedated horses were examined at 5 sites by use of pulsed-wave Doppler ultrasonography to determine a range of values for peak systolic, end diastolic, and mean velocities and resistive and pulsatility indices. Interobserver and patient variabilities were determined by 2 operators repeating similar measurements on 1 horse 8 times at weekly intervals. RESULTS: A range of values for each variable measured at the 5 selected sites was obtained. For each variable, strong positive correlations (R > or = 0.7) were detected for > 70% of the site-to-site comparisons made (excluding the coronary band). Among horses, resistive index varied least, whereas over time, mean velocity varied least. Waveform characteristics were consistent with resistive (n = 5) or nonresistive (4) patterns. In the single-horse experiment, waveform characteristics were consistent throughout the 8 weeks, and operator effects were not detected. CONCLUSIONS AND CLINICAL RELEVANCE: Doppler ultrasonography of no one site resulted in more reliable measurements of blood flow characteristics in thoracic limb arteries of horses. Mean velocity and resistive index were the least variable measurements made. Pulsed-wave Doppler ultrasonography may be a useful technique for evaluating diseases that alter normal thoracic limb arterial blood flow in horses.  相似文献   

9.
Resistive index (RI) and pulsatility index (PI) are indirect measurements of blood flow resistance that may be measured by pulsed wave Doppler ultrasonography. Chemical restrain may potentially alter the indices although it is required to perform ultrasonography in some patients. The purpose of this study was to describe values for both intrarenal and ocular RI and PI within the same subject in clinically normal dogs sedated with a midazolam and butorphanol combination and evaluate if there are any significant changes between sedated and nonsedated dogs. Fifteen healthy Beagle dogs were studied by Duplex Doppler interrogation in interlobar or arcuate arteries of the kidney and long posterior ciliary artery. Pulse rate and systolic blood pressure were also determined. All measurements were recorded before and after the administration of a sedative combination of midazolam (0.2 mg/kg) and butorphanol (0.2 mg/kg). Mean comparison tests (paired t-tests or Wilcoxon's rank-sum test) were used to determine if any significant differences existed between right and left renal values or right and left ocular values. A correlation study (Pearson or Spearman) was applied between RI, PI, and systolic pressure, and pulse rate. RI and PI were significantly higher in sedated Beagles than in unsedated Beagles. There was neither correlation between index and systolic blood pressure nor pulse rate. In conclusion, provided that normal RI and PI increase in sedated animals, then reference ranges should be higher when sedated--healthy or ill--animals are evaluated.  相似文献   

10.
Renal length, height, width, resistive index (RI), size of cortex, and medulla were determined by renal ultrasonography in 50 healthy Korean domestic short-hair cats. In the sagittal plane, the renal length was 3.83 ± 0.51 cm (mean ± SD) in the left kidney and 3.96 ± 0.48 cm in the right kidney, whereas the renal height was 2.42 ± 0.27 cm in the left kidney and 2.36 ± 0.28 cm in the right kidney. In the transverse plane, the renal height was 2.42 ± 0.28 cm in the left kidney and 2.38 ± 0.27 cm in the right kidney, whereas the renal width was: 2.65 ± 0.35 cm in the left kidney and 2.63 ± 0.31 cm in the right kidney. In the dorsal plane, the renal length was 3.84 ± 0.53 cm in the left kidney and 3.97 ± 0.54 cm in the right kidney, whereas the renal width was 2.65 ± 0.34 cm in the left kidney and 2.66 ± 0.33 cm in the right kidney. There were no significant differences (p > 0.05) among the same structure sizes measured in different planes. In the sagittal plane, the size of the renal cortex was 0.47 ± 0.08 cm in the left kidney and 0.47 ± 0.08 cm in the right kidney, whereas of the size of the renal medulla was 0.55 ± 0.30 cm in the left kidney and 0.50 ± 0.07 cm in the right kidney. RI evaluated by pulsed wave Doppler sonography was 0.52 ± 0.05 in the left kidney and 0.55 ± 0.05 in the right kidney. The actual renal dimensions determined by gross examination were not statistically different from those determined by ultrasonography. Furthermore the renal dimensions and RI were statistically correlated to the body weight of cats.  相似文献   

11.
A duplex ultrasound system incorporating a pulsed wave Doppler ultrasound probe with conventional B-mode real-time imaging was used to evaluate portal vein blood flow in eight normal dogs. Adequate visualization of the cranial abdominal vessels was obtained from the right lateral 11th or 12th intercostal space. Doppler spectral analysis showed non-pulsatile flow with a wide range of linear flow velocities across the vessel lumen typical of laminar blood flow. Results for portal vein blood flows were 49.8 ± 13.5 ml/min/kg body weight (mean ± SD) with a range of 37.8 - 76.8 ml/min/kg body weight. These values overestimate portal blood flow by approximately 2 times when compared with published studies using invasive techniques. This overestimation is primarily due to the use of the maximal flow velocity in the blood flow calculations.  相似文献   

12.
Background: The diagnosis of feline pancreatic disease is difficult, because clinical abnormalities and routine noninvasive diagnostic tests are unreliable. Objective: The purpose of this study was to investigate by Doppler ultrasonography if vascularity and blood volume differs in the otherwise ultrasonographically normal and diseased feline pancreas. Animals: Thirty‐six client owned cats. Methods: The pancreas was examined with B‐mode and contrast‐enhanced color and power Doppler ultrasonography. Doppler images were analyzed with a computer program: parameter fractional area represents a vascularity index and color‐weighted fractional area assesses blood volume. Results: Based on the B‐mode findings, the pancreas was considered normal in 11 clinically healthy cats and diseased in 25 cats of which 4 were clinically healthy and 21 had clinical signs consistent with pancreatic disease. Histologic or cytologic samples were taken in all diseased pancreata. Fifteen samples were of diagnostic quality: purulent or mixed cellular inflammation (8), nodular hyperplasia (4), and neoplasia (3) were identified. Vascularity and blood volume for all Doppler methods was significantly higher in cats with pancreatic disease. Significantly higher Doppler values were detected with power Doppler than with color Doppler, and with postcontrast color and power Doppler than with precontrast Doppler technologies. Conclusion: Contrast‐enhanced Doppler ultrasonography appears feasible in the feline pancreas. Significant differences were found between normal cats and those with evidence of pancreatic pathology. Further studies are needed to evaluate its use for the differentiation of pancreatic disorders and in cats suspected to have pancreatic disease but without B‐mode ultrasonographic changes of the pancreas.  相似文献   

13.

Background

Doppler ultrasonography is an important tool for evaluating hepatic portal hemodynamics. However, no study in dogs of different body weights, in the range encountered in routine clinical veterinary practice, has been reported. It can be difficult to obtain an ideal insonation angle when evaluating the main portal vein, so evaluation of the right portal vein branch has been described in humans as an alternative. The aim of this study was to analyze, through Doppler ultrasonography, the hemodynamics in the right portal vein branch in dogs of different body weights.

Methods

Thirty normal dogs were divided in three groups by weight, in order to establish normal values for mean velocity, flow volume and portal congestion index of the right portal vein branch by means of Doppler ultrasonography.

Results

In all dogs ideal insonation angles were obtained for the right portal vein branch. The average velocity was similar in the three groups, but the portal congestion index and the flow volume differed, showing that the weight of the dog can influence these values.

Conclusion

Doppler ultrasonography for the evaluation of flow in the right branch of the portal vein could be a viable alternative, or complement, to examining the main vessel segment. This is especially so in those animals in which an ideal insonation angle for examination of the main portal vein is hard to obtain. In addition, the weight of the dog must be considered for the correct evaluation of the portal system hemodynamics, particularly for portal blood flow and the congestion index.  相似文献   

14.
The resistive index (RI) is a measurement of arteriole vascular resistance and is obtained by pulsed-wave Doppler interrogation. The diagnostic potential of the renal resistive index (RI) was retrospectively investigated in 142 kidneys from 81 dogs. The resistive index of each kidney was compared to clinical laboratory parameters, clinical diagnoses, and sonographic findings. The mean renal resistive index (RI) for 22 normal kidneys was 0.61 (standard deviation = 0.06). An elevation in the mean renal RI (>0.70) was found for the clinical diagnoses of acute renal failure and congenital dysplasia. When a RI of greater than 0.70 was considered abnormal, the sensitivity and specificity of the RI in determining normal vs, abnormal kidneys were 38% and 96% respectively.  相似文献   

15.
Renal length and width dimensions were determined from survey radiography and excretory urography in 28 cats of various sex and reproductive status. Renal dimensions were expressed as a ratio to the length of the second lumbar vertebra. Renal dimensions were not significantly different when males were compared to females. However, significant differences in renal dimensions between intact and neutered cats were identified. Renal length ratios for neutered cats were: left kidney 2.22 +/- 0.14 (mean +/- standard deviation), right kidney 2.29 +/- 0.14. In intact cats, renal length ratios were: left kidney 2.60 +/- 0.19, right kidney 2.65 +/- 0.24. The mean renal length ratios for neutered cats was smaller than previously reported normal values. Thus, reproductive status should be considered when evaluating feline kidneys for alterations in size. Based on this study, normal feline renal length ratios range from 1.9 to 2.6 for neutered cats and 2.1 to 3.2 for intact cats.  相似文献   

16.
Ultrasonographic diagnosis of congenital portosystemic shunt in 14 cats   总被引:2,自引:0,他引:2  
Twenty-four cats with clinical and, or, clinico-pathological signs compatible with portosystemic shunting were examined prospectively using two-dimensional grey-scale, duplex and colourflow Doppler ultrasonography. Diagnosis of congenital portosystemic shunt was subsequently confirmed in 14 cats using operative mesenteric portography and surgery. Of the 14 affected cats, nine were purebred; eight were male and six female. The mean age at the time of diagnosis was nine months (range four to 27 months). Ultrasonographic evidence of a small liver was present in seven cats (50 per cent); visibility of intrahepatic portal vessels was reduced in three (21 per cent). An anomalous blood vessel was identified ultrasonographically in each cat; in 10 cats (71 per cent) the vessel was observed to originate from the portal vein and drain into the caudal vena cava. Abnormally variable portal blood flow waspresent in eight of the 10 cats in which it was measured. At surgery, six shunts were intrahepatic and eight extrahepatic; the ultrasonographic diagnosis of intra- versus extra-hepatic shunt was correct in 13 cats (93 per cent). No anomalous blood vessels or abnormalities affecting the portal vein were detected ultrasonographically in any of the 10 cats that did not have congenital portosystemic shunting. Hence, the accuracy of ultrasonography for diagnosis of congenital portosystemic shunting in this series was 100 per cent.  相似文献   

17.
OBJECTIVE: To determine the range of various cardiac parameters using echocardiography in apparently normal, healthy English Bull Terriers. DESIGN: Fourteen English Bull Terriers were selected for study. Cardiac auscultation of the parents of these dogs was normal. Echocardiographic examination of one parent of each animal showed: no mitral or aortic valve abnormalities; no myocardial lesions; no two dimensional evidence of fixed or dynamic left ventricular outflow tract obstruction; and no systolic aortic or left ventricular outflow tract turbulence on colour flow Doppler examination. The 14 selected dogs did not have arrhythmias or murmurs, and on echocardiographic examination had similar findings to their parents. Systolic blood pressure was measured in all dogs and they had no clinical evidence of Bull Terrier polycystic kidney disease or Bull Terrier hereditary nephritis. PROCEDURE: All dogs were auscultated and subjected to a sequential global echocardiographic assessment of the heart, including two dimensional long and short axis, and colour flow Doppler interrogation of the mitral and aortic valves. Dimensional measurements, including those from the left atrium, aortic annulus and left ventricle, were taken from a right parasternal window, and derived values such as fractional shortening, stroke volume and left atrial to aortic annulus ratio were calculated. Peak systolic aortic velocity was measured from the left parasternal window using two dimensional-guided pulsed wave Doppler with angle correction. Systolic blood pressure was measured using a Doppler monitor. The absence of Bull Terrier polycystic kidney disease was determined using renal ultrasonography, and of Bull Terrier hereditary nephritis using urinary protein to creatinine ratio. RESULTS: These 14 dogs had greater left ventricular wall thickness and smaller aortic root diameters than those reported as normal for other breeds of comparable body size. Left atrial dimensions were also larger, however this may have been due to the "maximising" method of measurement. These apparently normal English Bull Terriers also had higher aortic velocities than those reported for other breeds, possibly due to a smaller aortic root diameter or other anatomic substrate of the left ventricular outflow tract, lower systemic vascular resistance, or breed-specific "normal" left ventricular hypertrophy. While these dogs were selected to be as close to normal as possible, the breed may have a particular anatomy that produces abnormal left ventricular echocardiographic parameters. CONCLUSION: These echocardiographic parameters may be used to diagnose left ventricular outflow tract obstruction and left ventricular hypertrophy, and inaccurate diagnoses may result if breed-specific values are not used.  相似文献   

18.
This study evaluated the effects of thyroxine on renal function in the cat. Baseline serum thyroxine (T4) concentrations, clinicopathologic data (complete blood count [CBC], serum chemistry panel, urinalysis), and nuclear medicine determinations of glomerular filtration rate (GFR), effective renal plasma flow (ERPF), and effective renal blood flow (ERBF) were measured in 10 normal adult cats. Cats were then injected with thyroxine (T4) (50 micrograms/kg SQ) daily for 30 d to induce hyperthyroidism. Clinicopathologic and nuclear medicine studies were repeated at 30 d. Cats injected with thyroxine had significant increases in T4, GFR, and ERBF and significant declines in serum creatinine and blood urea nitrogen (BUN) values. Administration of high doses of exogenous thyroxine to cats results in significant stimulation of renal function.  相似文献   

19.
OBJECTIVE: To compare measurements of blood flow in the common femoral artery obtained by duplex Doppler ultrasonography (DDU) and a reference ultrasonic transit-time flow (TTF) method and to examine the impact of Doppler spectral waveform measurement techniques on volumetric estimates. ANIMALS: 5 healthy female pigs. PROCEDURES: Femoral arterial blood flow was measured simultaneously in anesthetized pigs by use of a TTF probe (left femoral artery) and transcutaneous DDU (right femoral artery). A range of flow states was induced pharmacologically by using xylazine, bradykinin, dobutamine, and isoflurane. Volumetric blood flow was calculated from DDU waveforms, using the product of the flow velocity integral (FVI), the cross-sectional vessel area, and heart rate. Three calculations of FVI were obtained by manually tracing the Doppler spectral envelopes at the outer envelope, the modal, and the inner envelope of the spectral dispersion pattern. Data analysis included calculation of Pearson correlation coefficients and Bland-Altman limits of agreement. RESULTS: Blood flow measured by DDU was more closely correlated with TTF measurements when the modal or inner envelope tracing method was used (r, 0.76 and 0.78; limits of agreement, -100 to 54.2 and -48.5 to 770 mL/min, respectively). Limits of agreement for the outer envelope tracing method were -238.5 to 64 mL/min. CONCLUSIONS AND CLINICAL RELEVANCE: Transcutaneous DDU is a reliable noninvasive technique for measuring blood flow in the femoral artery of pigs over a range of flow states. Tracing the inner envelope of the Doppler spectral dispersion pattern provided the best estimate of blood flow in this study.  相似文献   

20.
Changes in renal fnction of twenty-two cats treated for hyperthyrodism using radioiodine were evaluated. Serum thyroxine (T4), serum creatinine, blood urea nitrogen (BUN) and urine specificgravity were measured before treatment and 6 and 30 days after treatment. Twenty-two cats had pretreatment and 21 cats had 6 day posttreatment measurement of glomercular filtration rate (GFR) using nuclear medicine imaging techniques. there were significant declines in serum T4 at 6 days following treatment, but the changes in GFR, serum creatinine and BUN were not significant. At 30 days following treatment, there were significant increases in BUN and serum creatinine and further significant declines in serum T4. Nine cats were in renal failure prior to treatment and 13 cats were in renal failure 30 days following treatment. Renal failure was defined as BUN greater than 30 mg/dl and/or serum creatinine greater than 1.8 mg/dl with concurrent urine specific gravity less than 1.035. these 13 cats included eight of 9 cats in renal failure prior to treatment on 9 of these 13 cats indicated that all remained in renal failure. Based on receiver operating curve analysis of pretreatment glomerular filtration rate (GFR) in predicting posttreatment renal failure, a value of 2.25 ml/kg/min as a point of maximum sensitivity (100%) and spefificity (78%) was derived, Fifteen of 22 cats had pretratmentGFR measurements of less than 2.25 ml/kg/min. these 15 cats included all 9 cats in renal failure and 65 cats with normal renal clinicopathologic values prior to treatment. at 30 days following treatment, 13 of these 15 cats were in renal failure. The 2 cats not in renal failure had persistently increased serum T4 values. seven of 22 cats had pretreatment GFR measurements greater than 225 ml/kg/min. None of these 7 cats was in renal failure at 30 days following treatment, all cats having normal BUN, serum creatinine, and urine specific gravity values. It was concluded that significant declines in renal function occur after treatment of hyperthyroidism and this decline is clinically important in cats with renal disease. Pretreatment measurement of GFR is valuable in detecting subclinical renal disease and in predicting which cats may have clinically important declines in renal function following treatment.  相似文献   