首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVE:To evaluate the use of a portocaval venograft and ameroid constrictor in the surgical management of intrahepatic portosystemic shunts (PSS). STUDY DESIGN: Prospective, clinical study. Animal Population: Ten client-owned dogs with intrahepatic PSS. METHODS: Portal pressure was measured after temporary suture occlusion of the intrahepatic PSS. In dogs with an increase in portal pressure greater than 8 mm Hg, a single extrahepatic portocaval shunt was created using a jugular vein. An ameroid ring was placed around the venograft and the intrahepatic PSS was attenuated. Transcolonic pertechnetate scintigraphy was performed before surgery, 5 days after surgery, and 8 to 10 weeks after surgery. Dogs with continued portosystemic shunting were evaluated further by laparotomy or portography. Clinical outcome and complications were recorded. RESULTS: Mean (+/- SD) portal pressure increased from 6 +/- 3 to 19 +/- 6 mm Hg with PSS occlusion; in all 10 dogs, the increase in portal pressure was greater than 8 mm Hg. There were no intraoperative complications, and, after creation of the portocaval shunt, the intrahepatic PSS could be completely ligated in 8 of 10 dogs. The final portal pressure was 9 +/- 4 mm Hg. Postoperative complications included coagulopathy and death (1 dog), ascites (3 dogs), and incisional discharge (3 dogs). Five of 8 dogs had continued portosystemic shunting at 8 to 10 weeks after surgery. Multiple extrahepatic PSS were demonstrated in 4 of these dogs. Clinical outcome was excellent in all 9 surviving dogs. CONCLUSIONS AND CLINICAL SIGNIFICANCE: The surgical technique resulted in a high incidence of multiple extrahepatic PSS. Short-term clinical results were promising, but long-term outcome must be evaluated further.  相似文献   

2.
OBJECTIVES: To evaluate outcome in dogs with left divisional intrahepatic portosystemic shunts (PSS) treated by partial ligation (PL) or ameroid ring constrictor (ARC) placement on the left hepatic vein. DESIGN: Retrospective study. ANIMALS: Dogs (n=28) with left divisional intrahepatic PSS. METHODS: Retrieved data from medical records of dogs with left divisional intrahepatic PSS that had PL (n=17) or ARC (n=11) were signalment, history, clinical signs, preoperative blood work, portal pressure measurements, ARC size, complications and postoperative technetium scintigraphy. Outcome assessed by owner interview 6 months-10 years after surgery was classified as excellent, good or poor. Differences were tested by exact chi2 test. RESULTS: Major complications occurred in 3 dogs: coagulopathy (1 PL dog died), ascites (1 PL dog survived) and seizures (1 ARC dog died). Eight PL dogs had technetium portal scintigraphy; 1 dog was negative and 7 dogs positive for persistent shunting. Seven ARC dogs had scintigraphy; 4 dogs were negative and 3 positive for persistent shunting. In PL dogs, long-term clinical outcome was excellent (92%) or good (8%) whereas, in ARC dogs it was excellent (20%), good (50%) or poor (30%). This outcome difference between treatment groups was significant (P=.0012). CONCLUSION: Dogs treated by PL had significantly better long-term outcome compared with ARC treated dogs. CLINICAL RELEVANCE: Based on these data, ARC placement on the left hepatic vein in dogs with left-divisional intrahepatic PSS cannot be recommended.  相似文献   

3.
OBJECTIVE: To document the signalment; history; clinical signs; clinicopathologic, diagnostic imaging, and surgical findings; perioperative complications; and long-term clinical results of ameroid ring constrictor (ARC) placement on single extrahepatic portosystemic shunts (PSS) in cats. DESIGN: Retrospective study. ANIMALS: 23 cats treated with an ARC on a single extrahepatic PSS. PROCEDURE: An ARC was placed surgically around the PSS. Portal pressure was measured prior to ARC placement, with complete temporary PSS occlusion, and after ARC placement. Cats were scheduled for recheck transcolonic portal scintigraphy 8 to 10 weeks after surgery. Follow-up information was obtained by telephone interview with the owners. RESULTS: An ARC was successfully placed in 22 of 23 cats. Intraoperative complications, consisting of PSS hemorrhage, occurred in 2 cats. Mean (+/- SD) portal pressure (n = 15) was 6.7+/-2.9 mm Hg before PSS manipulation, 18.6+/-7.7 mm Hg with complete temporary PSS occlusion, and 6.9+/-2.7 mm Hg after ARC placement. Postoperative complications developed in 77% (17 of 22) of cats after ARC placement, and included central blindness, hyperthermia, frantic behavior, and generalized motor seizures. Perioperative mortality rate was 4.3% (1 of 23). Persistent shunting was identified in 8 of 14 cats. Overall, 75% (15 of 20) of cats had an excellent long-term outcome. CONCLUSIONS AND CLINICAL RELEVANCE: Placement of an ARC on single extrahepatic PSS in cats resulted in low surgical complication and perioperative mortality rates, but most cats did have substantial postoperative complications. Persistent shunting was common, although many cats with persistent shunting were clinically normal.  相似文献   

4.
OBJECTIVE: To evaluate the efficacy of cellophane banding of single congenital extrahepatic portosystemic shunts in dogs using transcolonic portal scintigraphy. To investigate the portal circulation of those dogs with elevated postoperative shunt fractions to determine the cause of the persistent shunting. Further, to evaluate whether presenting signs, clinical pathology findings and liver histopathology are predictive of outcome. DESIGN: Prospective study of 16 dogs presenting with single congenital extrahepatic portosystemic shunts. PROCEDURE: Dogs with single extrahepatic portosystemic shunts attenuated by cellophane banding underwent portal scintigraphy and bile acids tolerance testing pre- and post-operatively. Dogs identified with elevated shunt fractions at 10 weeks post-operatively underwent mesenteric portovenography. Qualitative hepatic histopathology from all dogs was reviewed by a veterinary pathologist and assigned a semi-quantitative score to identify any abnormalities that may predict surgical outcome. RESULTS: At 10 weeks post cellophane banding, 10 of 16 cases (63%) had normal shunt fractions, whilst six dogs (37%) had increased shunt fractions and seven dogs (44%) had increased serum bile acids. Of these dogs, mesenteric portovenography revealed incomplete closure of the shunt in three dogs (18.6%) and multiple acquired shunts in three dogs (18.6%). Liver histopathology findings were similar for all dogs, regardless of outcome. CONCLUSIONS: Cellophane banding is an efficacious method for complete gradual occlusion of single extrahepatic shunts when the shunt vessel is attenuated to < or = 3 mm. Transcolonic portal scintigraphy is a reliable method for assessment of shunt attenuation and, unlike serum bile acids, is not influenced by other causes of liver dysfunction.  相似文献   

5.
Gradual occlusion of the splenic vein, using a specialized device (ameroid constrictor), was evaluated experimentally in three normal beagle dogs. Splenoportograms were used to verify that total occlusion of the splenic vein had occurred in all dogs within 4 to 5 weeks after application of the device. The ameroid constrictor (AC) was also evaluated as a method of gradual vascular occlusion in 12 dogs and two cats with single, extrahepatic, portosystemic shunts (PSS). Serum bile acid (SBA) concentrations were measured and portal scintigraphy (PS) was performed on all 14 animals preoperatively and 10, 20, 30, and 60 days postoperatively. Two dogs (14%) died from portal hypertension in the early postoperative period. One dog and one cat developed multiple acquired PSS, confirmed by mesenteric portography 90 days after the operation. Portal scintigraphy confirmed total occlusion of the primary shunt in the other 10 animals. Shunt fractions (SF), as measured by PS on postoperative days 30 and 60, declined significantly from preoperative values. Significant decreases were noted between preoperative and postoperative values for preprandial SBA on postoperative day 60 and for postprandial SBA on postoperative day 30. SBA concentrations did not correlate with SF. Based on this study, gradual vascular occlusion using the AC is recommended as a method for treatment of single, extrahepatic, PSS.  相似文献   

6.
Per rectal portal scintigraphy using 99mTechnetium pertechnetate (99mTcO4-) was used to diagnose portosystemic shunts (PSS) before surgical confirmation in seven dogs and two cats. Shunt fractions, representing the percent of portal blood that bypasses the liver, were determined by computer analysis of the scintigraphic images. Animals with portosystemic shunts had a mean preoperative shunt fraction of 84.02% (n = 9). The mean postoperative shunt fraction in four animals was 58.22%. The mean shunt fraction in ten control dogs was 5.00%. Per rectal portal scintigraphy is an innovative, easily performed, inexpensive method to diagnose congenital portosystemic shunts in dogs and cats.  相似文献   

7.
OBJECTIVE : To determine prognostic evaluation and correlation of the degree of narrowing and the diameter of the portal vein in dogs with a congenital portosystemic shunt (CPS). STUDY DESIGN : Longitudinal prospective study. ANIMALS : Ninety-seven dogs with CPS. METHODS : Shunt diameter was recorded before and after silk ligation to calculate degree of closure. Portal vein diameter was measured in 74 dogs. Short-term (30 days) and long-term (>1 year) outcome were evaluated. Dogs with clinical signs after 1 year were re-examined to assess the degree of portosystemic shunting and compared with matched operated dogs without clinical signs. Correlations between clinical outcome, degree of closure, and portal vein diameter were statistically analyzed. RESULTS : Short-term and long-term mortality were 27% and 2.9% respectively. Clinical recurrence occurred in 10% of dogs. The degree of closure was significantly associated with mortality, but not with clinical recurrence. A significant correlation was found between degree of closure and the diameter of the cranial part of the portal vein. Portal vein diameter was only significantly associated with mortality in extrahepatic CPS. Subclinical portosystemic shunting was confirmed in 3 of 10 dogs. CONCLUSION : The degree of shunt closure depended on portal development. Long-term outcome did not depend on the degree of closure or portal development at the time of surgery. This suggested that factors such as hepatic and portal regeneration after surgery may be important. CLINICAL RELEVANCE : Determination of factors that predict the outcome after surgical treatment of CPS in dogs is important to gain insight in treatment selection or new therapeutic options.  相似文献   

8.
OBJECTIVE: To evaluate the use of a portocaval venograft without an ameroid constrictor in the surgical management of intrahepatic portosystemic shunts (PSS). STUDY DESIGN: Prospective clinical study. ANIMALS: Seven dogs with intrahepatic PSS. METHODS: Portal pressure was measured after temporary suture occlusion of the intrahepatic PSS. In dogs with an increase in portal pressure > or =8 mm Hg or signs of portal hypertension, a single extrahepatic portocaval shunt was created using a jugular vein. Clinical outcome and complications were recorded. RESULTS: The mean (+/-SD) portal pressure increased from 5.9+/-1.6 to 17.9+/-4.1 mm Hg with PSS occlusion. There were no intraoperative complications and, after creation of the portocaval shunt, the intrahepatic PSS could be completely ligated in all dogs. The final portal pressure was 9.6+/-1.9 mm Hg. Complications developed during postoperative hospitalization in 5 dogs and included incisional discharge (4 dogs), ascites (3), ventricular premature contractions (2), and melena, bloody diarrhea, neurologic signs, coagulopathy, and aspiration pneumonia (each in 1 dog). Six dogs died or were euthanatized with clinical signs related to depression, inappetance, abdominal pain, vomiting, melena, and abdominal distention, with a median survival of 82 days (range, 20-990 days). One dog was clinically normal at 33 months after surgery. CONCLUSIONS: Clinical signs observed in 6 dogs after surgery were consistent with portal hypertension. Use of a portocaval venograft without an ameroid constrictor may reduce the likelihood of hepatic vascular development, thereby increasing the risk of life-threatening portal hypertension should the venograft suddenly occlude. CLINICAL RELEVANCE: Use of a portocaval venograft without an ameroid constrictor to control portal hypertension after ligation of an intrahepatic PSS cannot be recommended.  相似文献   

9.
OBJECTIVE: To evaluate outcomes after attenuation of extrahepatic portosystemic shunts in dogs using surgical silk. DESIGN: Retrospective study. PROCEDURE: Case records were reviewed for degree of surgical attenuation, experience of the primary surgeon, perioperative mortality and problems related to persistent portosystemic shunting or shunt ligation. Presence of portosystemic shunting after surgery was evaluated by ammonia tolerance testing, measurement of postprandial serum bile acid, plasma urea and cholesterol concentrations and liver enzyme activity. The influence of age, postocclusion portal pressure, primary surgeon, degree of attenuation and postoperative biochemical findings on the occurrence of postoperative problems was assessed. RESULTS: The mortality rate was 2.1%. Shunt attenuation was complete in 34% and partial in 66% of dogs. Portal hypertension necessitating ligature removal was encountered in only one dog. Five dogs experienced neurological abnormalities (seizures or ataxia), possibly as a manifestation of 'postligation seizure syndrome'. Postoperative liver function was normal in 78% of dogs, including 70% with partial shunt attenuation. Experience of the surgeon was related positively to outcome after partial attenuation (P = 0.002). Postoperative biochemical evidence of abnormal liver function was the most sensitive predictor of recurrence of clinical signs referable to persistent portosystemic shunting. CONCLUSIONS: In the hands of an experienced surgeon, surgical attenuation of single extrahepatic shunts was safe and effective, even in animals with partial attenuation. Most dogs with biochemical evidence of persistent shunting suffer relapse of clinical signs within 18 months of surgery. Postligation neurological syndromes of variable intensity may be more common than previously thought.  相似文献   

10.
The medical records of 65 dogs that underwent complete or partial ligation of a single congenital portosystemic shunt (CPSS) were reviewed to determine the long-term clinical results. Information retrieved from the records included age at surgery, preligation (baseline) portal pressure, postligation portal pressure, change in portal pressure from baseline, complete or partial occlusion of the shunting vessel and fasting, and 2-hour postprandial bile acids from the preoperative, early postoperative (PO), and greater than 1 year PO time periods. A clinical rating score derived from a follow-up examination greater than 1 year PO was assigned to each dog. Of the 56 dogs that survived the perioperative period, 29 (52%) had complete and 27 (48%) had partial ligations. Age at surgery, pre- and postligation portal pressure, change in portal pressure from baseline and serum bile acid concentrations were not related to long-term clinical outcome. Clinical rating scores were significantly greater for dogs with partial CPSS ligations compared with dogs with complete ligations, indicating a less favorable clinical outcome for partial ligations. Fasting and 2-hour postprandial bile acid values at both PO time intervals were significantly greater in partial versus complete ligation groups. Follow-up information for more than 1 year was available on 18 of 29 dogs (62%) with complete ligations. All were clinically normal. Of 27 dogs with partial ligations, 11 dogs (41%) developed recurrence of clinical signs resulting in presentation to the university or referring veterinarian for additional surgery, medical management, or euthanasia. Only three dogs with partial CPSS ligation (11%) were clinically normal. Another nine dogs (33%) were operated on again before the possible development of clinical signs and four dogs (15%) were unavailable for follow-up. It was concluded that partial ligation of CPSS is associated with a greater recurrance of clinical signs and patient morbidity than complete ligation.  相似文献   

11.
OBJECTIVE : To report outcomes after cellophane banding of single congenital portosystemic shunts in dogs and cats. STUDY DESIGN : Retrospective study of sequential cases. ANIMALS : One hundred and six dogs and five cats. METHODS : Medical records were reviewed for breed, sex, age at surgery, shunt anatomy, results of pre- and postoperative biochemical analysis, development of postligation neurologic dysfunction, portal hypertension or other serious complications, and the owners' perception of their animal's response to surgery. RESULTS : Ninety-five dogs and all 5 cats had extrahepatic shunts. Eleven dogs had intrahepatic shunts. Six dogs (5.5%) died as a result of surgery from portal hypertension (2 dogs), postligation neurologic dysfunction (2), splenic hemorrhage (1) and suspected narcotic overdose (1). Serious complications were more common in dogs with intrahepatic shunts than those with extrahepatic shunts (P=.002). Postligation neurologic dysfunction necessitated treatment in 10 dogs and 1 cat; 8 dogs and the cat survived. Clinical signs attributed to portosystemic shunting resolved or were substantially attenuated in all survivors. Postoperative serum bile acid concentrations or results of ammonia tolerance testing were available for 88 animals; 74 (84%) were normal and 14 (16%) were abnormal. Multiple acquired shunts were documented in two animals. CONCLUSIONS : Cellophane banding is a safe and effective alternative to other methods of attenuation. CLINICAL RELEVANCE : Slow occlusion of portosystemic shunts using a variety of methods is being evaluated world wide. Cellophane banding is a relatively simple procedure with comparable safety and efficacy to previously reported techniques.  相似文献   

12.
Objective To evaluate the efficacy and short term effects of a cellophane banding technique for progressive attenuation of canine single extrahepatic portosystemic shunts.
Design A prospective trial of 11 dogs with single congenital extrahepatic shunts.
Procedure Rectal ammonia tolerance testing and routine biochemical tests were performed preoperatively on all dogs. In seven dogs, preoperative abdominal Doppler ultrasonography was also performed. Exploratory laparotomy revealed a single extrahepatic portocaval shunt in each animal, which was attenuated using a cellophane band with an internal diameter of 2 to 3 mm. The abdomen was closed routinely. Follow-up biochemical analysis and abdominal Doppler ultrasonography or splenoportography were performed postoperatively.
Results The shunt was not amenable to total ligation in 11 dogs, based upon reported criteria. All dogs recovered uneventfully from surgery without evidence of portal hypertension, and showed clinical improvement thereafter. Shunt occlusion was deemed to have occurred in 10 dogs based on resolution of biochemical and/or sonographic abnormalities. One dog continued to have sonographic evidence of portosystemic shunting when evaluated 3 weeks after surgery, despite normal ammonia tolerance, but was lost to subsequent follow-up. Two dogs, in which 3 mm cellophane bands were placed, experienced delayed shunt occlusion.
Conclusion Cellophane banding is simple to perform, and causes progressive attenuation of single extrahepatic shunts in dogs. Further work is needed to determine the maximum diameter of a cellophane band which will produce total attenuation, and the long-term safety and reliability of the treatment.  相似文献   

13.
Two dogs with simultaneous congenital and acquired portosystemic shunts are reported. The first dog was an eight-month-old, male Golden Retriever with a history of peritoneal effusion, polyuria/polydipsia, and stunted growth. The dog had a microcytic, hypochromic anemia, a mildly elevated AST, and a moderate to severely elevated preprandial and postprandial serum bile acids. Transcolonic portal scintigraphy confirmed the presence of a portosystemic shunt. An intraoperative mesenteric portogram was performed. Two conjoined congenital extrahepatic portosystemic shunts and multiple acquired extrahepatic portosystemic shunts were identified. The second dog was a five-month-old, mixed breed with two week history of peritoneal effusion. Abdominal ultrasound and transcolonic scintigraphy were used to diagnose a portosystemic shunt. A single extrahepatic portosystemic shunt, portal hypertension, and multiple acquired collateral shunts were identified at surgery. The histologic alterations observed in these dogs were consistent with a portosystemic shunt. In these dogs, the presence of congenital and acquired portosystemic shunts and histopathologic findings are considered to represent a combination of congenital portosystemic shunts and noncirrhotic portal hypertension or portal vein hypoplasia.  相似文献   

14.
The aims of this study were to determine if accurate diagnosis of congenital portosystemic shunt was possible using two dimensional, grey-scale ultrasonography, duplex-Doppler, and color-flow Doppler ultrasonography in combination, and to determine if dogs with congenital portosystemic shunts have increased or variable mean portal blood flow velocity. Eighty-two dogs with clinical and/or clinicopathologic signs compatible with portosystemic shunting were examined prospectively. Diagnosis of congenital portosystemic shunt was subsequently confirmed in 38 of these dogs using operative mesenteric portography: 14(37%) dogs had an intrahepatic shunt and 24(63%) had an extrahepatic shunt. Ultrasonography had a sensitivity of 95%, specificity of 98%, and accuracy of 94%. Ultrasonographic signs in dogs with congenital portosystemic shunts included small liver, reduced visibility of intrahepatic portal vessels, and anomalous blood vessel draining into the caudal vena cava. Correct determination of intra - versus extrahepatic shunt was made ultrasonographically in 35/38 (92%) dogs. Increased and/or variable portal blood flow velocity was present in 21/30 (70%) dogs with congenital portosystemic shunts. In one dog with an intrahepatic shunt the ultrasonographic diagnosis was based partly on finding increased mean portal blood flow velocity because the shunting vessel was not visible. Detection of the shunting vessel and placement of duplex-Doppler sample volumes were facilitated by use of color-flow Doppler. Two-dimensional, grey-scale ultrasonography alone is sufficient to detect most intrahepatic and extrahepatic shunts; sensitivity is increased by additional use of duplex-Doppler and color-flow Doppler. Increased and/or variable portal blood flow velocity occurs in the majority of dogs with congenital portosystemic shunts.  相似文献   

15.
Cases diagnosed with portosystemic shunting between the years 1993 and 2001 were reviewed. Sensitivities of screening tests and abdominal ultrasonographic evaluation for the detection of portosystemic shunting were evaluated. Prognosis for surgically treated shunts was also evaluated. Results indicated that both paired serum bile acids and blood ammonia levels were useful screening tests for portosystemic shunting. However, paired bile acid tests were significantly more sensitive than blood ammonia levels. Overall postoperative mortality rates for extrahepatic shunts and intrahepatic shunts were 8.7% and 20%, respectively. Postoperative mortality rates were slightly higher for animals treated with partial ligation when compared to those treated with ameroid ring placement, although this did not reach statistical significance. Long-term complication rates for animals with single extrahepatic portosystemic shunts treated with complete ligation, ameroid ring placement, and partial ligation alone were 9%, 15.4%, and 42%, respectively. Animals >2 years of age with extrahepatic shunts had almost identical postoperative mortality and long-term complication rates as animals < or = 2 years of age. No animal in this study had paired bile acid samples within the reference range postoperatively, indicating continued abnormal liver function after surgery.  相似文献   

16.
We describe the use of ultrasonography‐guided percutaneous splenic injection of agitated saline and heparinized blood for the diagnosis of portosystemic shunts (PSS) in 34 dogs. Agitated saline mixed with 1 ml of heparinized autologous blood was injected into the spleen of 34 sedated dogs under sonographic guidance. The transducer was then sequentially repositioned to visualize the portal vein, the caudal vena cava, and the right atrium through different acoustic windows. It was possible to differentiate between intrahepatic and extrahepatic shunts depending on the entry point of the microbubbles into the caudal vena cava. Portoazygos shunts and portocaval shunts could be differentiated based on the presence of microbubbles in the caudal vena cava and/or the right atrium. In one dog, collateral circulation due to portal hypertension was identified. In dogs with a single extrahepatic shunt, the microbubbles helped identify the shunting vessel. The technique was also used postoperatively to assess the efficacy of shunt closure. All abnormal vessels were confirmed by exploratory laparotomy or with ultrasonographic identification of the shunting vessel. Ultrasound‐guided transsplenic injection of agitated saline with heparinized blood should be considered as a valuable technique for the diagnosis of PSS; it is easy to perform, safe, and the results are easily reproducible.  相似文献   

17.
The value of ultrasonography was evaluated in 85 dogs and 17 cats presented with a clinically suspected portosystemic shunt (PSS). A PSS was confirmed in 50 dogs and nine cats (single congenital extrahepatic in 42, single congenital intrahepatic in 11, and multiple acquired in six). Six dogs and one cat had hepatic microvascular dysplasia, and 29 dogs and seven cats had a normal portal system. Ultrasonography was 92% sensitive, 98% specific, and had positive and negative predictive values of 98% and 89%, respectively, in identifying PSS, with an overall accuracy of 95%. When a PSS was identified with ultrasonography, extrahepatic, intrahepatic, and multiple acquired PSS could be correctly differentiated in 53/54 patients (98%). The combination of a small liver, large kidneys, and uroliths had positive and negative predictive values of 100% and 51% for the presence of a congenital PSS in dogs. The portal vein/aorta (PV/Ao) and portal vein/caudal vena cava (PV/ CVC) ratios were smaller in animals with extrahepatic PSSs compared with animals with microvascular dysplasia, intrahepatic PSSs and those without portal venous anomalies (P<0.001). All dogs and cats with a PV/Ao ratio of < or = 0.65 had an extrahepatic PSS or idiopathic noncirrhotic portal hypertension. Dogs and cats with PV/Ao and PV/CVC ratios of > or = 0.8 and > or = 0.75, respectively, did not have an extrahepatic PSS. Reduced or reversed portal flow was seen in four of four patients with multiple acquired PSSs secondary to portal hypertension. The presence of turbulence in the caudal vena cava of dogs had positive and negative predictive values of 91% and 84%, respectively, for the presence of any PSS terminating into that vein.  相似文献   

18.
OBJECTIVE: To determine postoperative (< or = 6 days), short-term (< or = 90 days), and long-term (> or = 6 months) outcomes of cats undergoing ameroid constrictor occlusion of single congenital extrahepatic portosystemic shunts (PSS) and identify factors associated with outcome. DESIGN: Retrospective study. ANIMALS: 12 cats. PROCEDURE: Cats with single congenital PSS that underwent surgical placement of ameroid constrictors were identified. Follow-up information was obtained through telephone interviews and facsimile correspondence with referring veterinarians and owners. Results-All cats survived the surgery and were discharged from the hospital. One cat had seizures during the postoperative period. Five cats were clinically normal during follow-up evaluations within 90 days after the surgery. Long-term follow-up information was available for 9 cats. Three were clinically normal, 4 had been euthanatized because of progressive neurologic disease, and 2 had neurologic abnormalities that could not be controlled with medication. Four of 7 cats with continued or recurrent neurologic abnormalities 1 or more months after surgery had normal scintigraphic or hepatic function test results 2 to 6 months after surgery. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that the long-term outcome of ameroid constrictor occlusion of PSS in cats is poor. Owners of older cats and cats with preexisting neurologic signs should be made aware of the potential for a poor outcome when considering surgical correction of this disease.  相似文献   

19.
Objective —To evaluate lack of encephalopathy as a positive prognostic factor for complete ligation of extrahepatic congenital portosystemic shunts in dogs.
Study Design —Retrospective analysis of case records.
Animals —Dogs with extrahepatic congenital portosystemic shunts treated at the Veterinary Medical Teaching Hospital of the College of Veterinary Medicine, Cornell University, from 1985 to 1996.
Methods —The ability to completely ligate the shunting vessel in 12 nonencephalopathic dogs was compared with that in 44 encephalopathic dogs with similar shunts.
Results —Clinical signs in the 12 nonencephalopathic dogs were related to ammonium biurate urolithiasis. All 12 dogs had single extrahepatic shunting vessels. The rate of complete ligation in the nonencephalopathic dogs was 92%, whereas the rate of complete ligation in the 44 encephalopathic dogs with single extrahepatic shunts was 59%. The ability to completely ligate the shunt in nonencephalopathic dogs was significantly better ( P = .04) than in the encephalopathic dogs.
Conclusion—Lack of encephalopathy is a positive prognostic factor for complete ligation of single extrahepatic congenital portosystemic shunts.
Clinical Relevance —In most affected dogs, extrahepatic congenital portosystemic shunts in nonencephalopathic dogs can be completely ligated.  相似文献   

20.
A prospective study was conducted to determine the sensitivity and specificity of diagnosis of portosystemic shunts (PSS) and the accuracy of anatomically locating single congenital PSS in dogs using magnetic resonance angiography (MRA). MRA was performed on 10 normal dogs and 23 dogs with PSS. Sensitivity and specificity of MRA to diagnose any shunt among all dogs were 80% and 100%, respectively. Among dogs identified with PSS, sensitivity and specificity of MRA for diagnosis of multiple extrahepatic shunts were 63% and 97%, respectively, and for diagnosis of single congenital shunts were 79% and 100%, respectively. Using MRA, radiologists correctly identified shunts as extrahepatic or intrahepatic in 83% of patients and correctly identified the origin and insertion of the shunts in 57% and 97% of patients, respectively. Use of MRA is specific for diagnosis of PSS and is a sensitive indicator of anatomic location of single congenital portosystemic shunts.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号