首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
The objective of this study was to determine the intra- and inter-observer variability of echocardiographic measurements in dogs. Four observers with different levels of experience in echocardiography performed 192 echocardiographic examinations of six dogs on four different days. The lowest within- and between-day coefficients of variation (CV) (%) were 13.8 and 5.2 for the right ventricle in diastole, 8.9 and 4.5 for the interventricular septal thickness in diastole (6.3 and 7.0 in systole), 7.7 and 9.4 for the left ventricular free-wall thickness in diastole (8.1 and 5.2 in systole), 3.1 and 5.0 for the left ventricular end-diastolic diameter (6.2 and 7.0 for end-systolic diameter), 10.2 and 10.8 for the left ventricular shortening fraction, and 8.2 and 9.8 for the left atrium/aorta ratio, respectively. Most of these lowest CVs were observed by the two most experienced observers. Conversely, all maximum values were obtained with the two less experienced observers. These differences in observer-dependent variability may considerably influence the minimum number of animals required to detect a treatment-associated change in echocardiographic variables.  相似文献   

2.
OBJECTIVE: To evaluate the effects of positioning and number of repeated measurements on intra- and interobserver variability of echocardiographic measurements in dogs. DESIGN: Prospective study. ANIMALS: 4 healthy dogs. PROCEDURE: Each observer performed 24 examinations, separately assessing each dog 6 nonconsecutive times (3 times with the dog in lateral recumbency and 3 with the dog in a standing position). Variables evaluated included M-mode measurements of left ventricular end-diastolic and left ventricular end-systolic diameters, left ventricular free-wall thickness in diastole and systole, interventricular septal thickness in diastole and systole, left ventricular shortening fraction, and 2-dimensional measurements of the left atrial diameter-to-aortic diameter ratio. RESULTS: All coefficients of variation (range, 3.4% to 26.6%) were similar between operators and positions and were < 15% for 27 of 32 values. For both operators, repeatability of the measurements was better for left ventricular end-systolic diameter, left ventricular free-wall thickness in diastole, left ventricular free-wall thickness in systole, and the left atrial diameter-to-aortic diameter in the standing position, and similar for both positions for shortening fraction and left ventricular end-diastolic diameter. No effect of cardiac cycle was observed. CONCLUSIONS AND CLINICAL RELEVANCE: Within-day variability of conventional echocardiography performed with the dog in the standing position was at least as good as that obtained with the dog in lateral recumbency for most measured variables. Single measurements of each variable may be sufficient for trained observers examining dogs that do not have an arrhythmia. The standing position should be used, particularly for stressed or dyspneic dogs.  相似文献   

3.
In healthy cats sedated with a combination of ketamine hydrochloride and acepromazine, the reproducibility of sequential echocardiographic examinations was studied. The effects of experimental alteration in heart rate, contractility, and preload on the echocardiogram also were studied. Ten cats had M-mode echocardiograms recorded once weekly for 5 weeks. There were no statistically significant differences in echocardiographic measurements over time, although measurements of certain cardiac structures of an individual cat did vary from time to time. The cardiovascular system was altered by a constant infusion of isoproterenol, followed by a rapid intravenous infusion of isotonic fluid equal to 25% of the calculated blood volume, and then by a rapid withdrawal of blood equal to the amount of fluid previously given. Cardiac output using indocyanine green dilution curves were determined for each treatment and compared to the cardiac output calculated from the echocardiogram. The correlation coefficient was 0.90 for all treatments. During the infusion of isoproterenol a significant increase in the percent fractional shortening and left ventricular wall amplitude occurred compared to the control echocardiogram. After the rapid infusion of fluid, none of the mean echocardiographic measurements significantly changed from control values although the left ventricular chamber diameter at systole significantly increased, and the percent fractional shortening significantly decreased, when compared to values obtained during isoproterenol infusion. Significant changes recorded between echocardiographic measurements made after blood withdrawal compared to those made after fluid loading included an increase in left ventricular wall thickness at diastole, a decrease in left ventricular diameter at diastole, and a decrease in the present left ventricular wall thickening. Cats were terminated and the average of measurements made during the repeatability study of the septal and left ventricular wall thickness during systole, rather than during diastole, more closely approximated the postmortem measurements.  相似文献   

4.
Change in M-mode echocardiographic values in cats given ketamine   总被引:1,自引:0,他引:1  
Determination was made of changes in heart rate and certain M-mode echocardiographic values in healthy cats given ketamine (3 to 5 mg/kg, IM). Heart rate and septal and left ventricular posterior wall thickness in diastole increased, and left ventricular internal diameter in diastole and shortening fraction decreased (P less than 0.02) after ketamine was given. With the adjustment for heart rate by analysis of covariance, left ventricular internal diameter in diastole, shortening fraction, and velocity of circumferential fiber shortening were significantly decreased (P less than 0.05) from base-line values.  相似文献   

5.
OBJECTIVE: To determine reference values for M-mode echocardiographic parameters in nonsedated healthy adult Maine Coon cats and compare those values with data reported for nonsedated healthy adult domestic cats. DESIGN: Prospective study. ANIMALS: 105 healthy adult Maine Coon cats. PROCEDURE: Over a 3-year period, M-mode echocardiographic examinations (involving a standard right parasternal transthoracic technique) were performed on Maine Coon cats as part of prebreeding evaluations; values of M-mode parameters in healthy individuals were collected, and mean values were calculated for comparison with those reported for healthy adult domestic cats. RESULTS: The mean +/- SD weight of Maine Coon cats was significantly greater than that of domestic cats. Mean values of left ventricular internal dimension at end diastole and end systole (LVIDd and LVIDs, respectively), interventricular septal thickness at end systole (IVSs), left ventricular posterior wall thickness at end systole (LVPWs), left atrial dimension at end systole (LADs), and aortic root dimension (Ao) in Maine Coon cats differed significantly from values in healthy domestic cats. The greatest differences detected between the 2 groups involved values of LVIDd, LADs, and Ao. Linear regression analysis revealed a weak but significant correlation between weight and each of LVIDd, LVPWs, IVSs, Ao, LADs, and left ventricular posterior wall thickness at end diastole. CONCLUSIONS AND CLINICAL RELEVANCE: Values of several M-mode echocardiographic parameters in Maine Coon cats differ from those reported for domestic cats; these differences should be considered during interpretation of echocardiographic findings to distinguish between cardiac health and disease in this breed.  相似文献   

6.
Background: Hypohydration causes transient echocardiographic changes in pigs, dogs, humans, and cats. These changes mask the diagnosis of some cardiac diseases (valvular regurgitation, dilated cardiomyopathy) and promote the diagnosis of others (hypertropic cardiomyopathy and infiltrative disease), thus inhibiting accurate echocardiographic evaluation. Objectives: To describe the echocardiographic changes associated with hypohydration in normal horses. Animals: Ten adult horses without detectable cardiac disease. Methods: Experimental study. Echocardiographic examinations were performed on horses in the euhydrated and hypohydrated states. Horses were hypohydrated by combined water deprivation and furosemide administration until a 4–7% reduction in bodyweight was achieved. Statistical analyses were performed by paired t‐tests. Results: Hypohydration decreased left ventricular internal diameter in systole (0.8 ± 0.6 cm) and diastole (1.7 ± 0.9 cm), left atrial diameter (1.5 ± 0.4 cm) and left ventricular volume (490 ± 251 mL) (P‐values < .01), and increased septal wall thickness in diastole (0.6 ± 0.3 cm), free wall thickness in diastole (0.5 ± 0.3 cm), mean wall thickness (0.5 ± 0.2 cm) and relative wall thickness (0.2 ± 0.1 cm) (P‐values < .01). Conclusions and Clinical Importance: Hypohydration produces changes in left ventricular and atrial size that could mask or promote the severity of cardiac disease. The thickened, “pseudohypertrophied” appearance of the left ventricle in hypohydrated horses could affect interpretation of echocardiographic variables that are applied to the prediction of athletic performance. Echocardiography may prove a noninvasive method of monitoring volume status and response to fluid therapy in hypovolemic horses.  相似文献   

7.
The use of transthoracic echocardiography in dolphins has been limited so far owing to technical and anatomical specificities. Anatomic M-mode (AMM) is a postprocessing echocardiographic technique generating M-mode studies from two-dimensional (2D) cineloops independently of the ultrasound beam orientation. The aim of the present study was to determine the within-day (repeatability) and between-day (reproducibility) variability of AMM echocardiography in awake healthy bottlenose dolphins (BN, Tursiops truncatus). Four adult BN trained to lie in left recumbency at the water surface were involved in the protocol. A total of 96 echocardiographic examinations were performed on 4 different days by a trained observer examining each BN 6 times per day. Video clips of 2D left parasternal long-axis views showing the left ventricle (LV) ventrally and the aortic root dorsally were recorded at each examination and analyzed for AMM measurements in a random order. A general linear model was used to determine the within-day and between-day coefficients of variation (CV). All examinations were interpretable allowing calculation of 10 AMM variables (i.e., end-diastolic and end-systolic ventral and dorsal LV myocardial wall thicknesses as well as LV and aortic diameters, mean aortic diameter, and LV shortening fraction). Most within- and between-day CV values (18/20) were <15%, the lowest being observed for the end-diastolic LV diameter (1.6%). In conclusion, AMM provides a simple non-invasive evaluation of heart morphology and function in the awake BN with good repeatability and reproducibility of the measurements. Further studies are required to determine the corresponding reference intervals.  相似文献   

8.
Left ventricular hypertrophy signals a poor prognosis in hypertensive humans. Cardiac disease is common in cats with systemic hypertension. The aims of this study were to characterize the echocardiographic findings of cats with systemic hypertension and to determine if reducing the degree of hypertension is associated with resolution of cardiac hypertrophy. Echocardiographic examinations were performed on 19 cats with naturally occurring systemic hypertension. Fourteen of these cats were subsequently studied after a minimum of 3 months of treatment with the antihypertensive agent amlodipine. Hypertensive cats had a significantly thicker interventricular septum in both systole and diastole, thicker left ventricular free wall in both systole and diastole, and larger left atrium compared to the published normal values and 74% (14/19) of the cats met criteria for left ventricular hypertrophy (diastolic septal or free-wall thickness > 0.60 cm). Systolic blood pressure was lower after treatment (217 +/- 25 mm Hg, range: 180-275 mm Hg; and 142 +/- 27 mm Hg, range: 90-200 mm Hg). No difference was found in any of the echocardiographic measurements between the untreated and treated cats, although more cats had ventricular hypertrophy before treatment (11/14) than after initiating amlodipine (6/14; P = .006). Ventricular hypertrophy is common in hypertensive cats and may resolve after the initiation of amlodipine.  相似文献   

9.
Echocardiographic findings in 103 cats with hyperthyroidism   总被引:1,自引:0,他引:1  
Using M-mode echocardiography, cardiac abnormalities were studied in 103 cats with untreated hyperthyroidism. In addition, follow-up echocardiography was performed on 24 of these cats to assess the long-term (4 to 21 months) effect of treatment (thyroidectomy or radioiodine) on thyrotoxic cardiac disease. The most common echocardiographic abnormality in the 103 untreated hyperthyroid cats was hypertrophy of the left ventricular caudal wall (71.9%). Hypertrophy of the interventricular septum also was documented in 39.8% of the 103 cats. Other abnormalities included high values for left atrial diameter (70.0%), aortic root diameter (18.5%), and left ventricular diameter at end diastole (45.6%). In some of these cats, indices of contractility were enhanced; in 21.4% and 14.6% of the cats, values for shortening fraction and velocity of circumferential fiber shortening, respectively, were greater than those values measured in clinically normal cats. After treatment of the hyperthyroidism, left ventricular hypertrophy resolved or improved in many of the cats, as indicated by decreases in left ventricular caudal wall and interventricular septum thicknesses. Hyperdynamic wall motion resolved in all cats after treatment, as evidenced by consistent decreases in shortening fraction and velocity of circumferential fiber shortening. Despite these improvements, some cats had one or more persistently abnormal echocardiographic values after treatment. These results suggested that in cats, hyperthyroidism commonly is associated with largely reversible cardiomyopathy. In those cats in which cardiomyopathy persists or worsens after treatment, underlying primary cardiomyopathy or thyroid hormone-induced cardiac structural damage may exist.  相似文献   

10.
Left ventricular echocardiographic parameters in cats were recorded, measured and analyzed to study the effects of a combination of xylazine and sodium pentobarbital on left ventricular function. The depressant effects of a combination of xylazine and sodium pentobarbital on the left ventricular dimension at end diastole, the percent change in minor diameter and the velocity of circumferential fibre shortening were compared to echocardiographic values of unanesthetized cats. No change in heart rate was noted. Stroke volume and cardiac output were depressed.  相似文献   

11.
Echocardiographic examinations were performed on 25 normal healthy cats placed in left lateral recumbency. The cats were representative of serveral breeds, consisted of 12 males and 13 females, and weighed between 2 and 6.5 kg. Twelve measurements from the echocardiograms of each cat were made for the purpose of compiling a small data base (reference values). These measurements included wall thicknesses, luminal dimensions, and contractile indices. Left ventricular wall thickness averaged 0.37 +/- 0.08 cm, and the septal wall thickness averaged 0.45 +/- 0.09 cm. The average left ventricular lumen in diastole was 1.48 +/- 0.26 cm, and in systole, it was 0.88 +/- 0.24 cm, which resulted in an average shortening fraction of 41 +/- 7.3%. Velocity of circumferential shortening, an index of contractility, averaged 2.86 +/- 0.78 cm. In eight additional cats, both ventricles were catheterized for echographic chamber identification and then cineangiographic procedures. Then these cats were euthanatized, and postmortem measurements were compared with echocardiographic and cineangiographic measurements. According to the three methods of determining wall thickness, differences were less than 15%, where the range of deviations was between 0 and 0.5 mm and the average deviation was -0.01 +/- 0.26 mm.  相似文献   

12.
A retrospective study was performed in 75 hypertensive cats to determine the spectrum and frequency of M-mode echocardiographic abnormalities. Results indicated that 21.3% of the cats had M-mode measurements within normal reference ranges. For cats with echocardiographic abnormalities, changes were variable. Thirty-nine percent of hypertensive cats had hypertrophy of the interventricular septum in diastole, and 41.3% had hypertrophy of the left ventricular (LV) posterior wall in diastole. One cat in five had a dilated left atrium, while fractional shortening and LV internal dimension in diastole were normal in 82.7% and 86.7% of the cats, respectively. The marked variability of echocardiographic findings in hypertensive cats made echocardiography an unreliable screening test for hypertension.  相似文献   

13.
Donkey (Equus asinus), the cheapest form of agricultural power in Egypt, is used principally as draught or pack animals and may also be ridden, or used for threshing, raising water, milling, and other work. The aim of the present study was to provide B-mode and M-mode echocardiographic reference ranges from a sample of population of donkeys (E. asinus) based on the probability theory and statistics. In the present study, B-mode and 2-dimensional guided M-mode echocardiography were performed on 44 clinically healthy donkeys (E. asinus) (22 males and 22 females), without any neither clinical nor echocardiographic evidence of cardiovascular diseases, aged 2–25 year old, and weighed 150–350 kg. The echocardiographic dimensions, including interventricular septum thickness at end diastole, interventricular septum thickness at end systole, left ventricular internal diameter at end diastole, left ventricular internal diameter at end systole, left ventricular posterior wall thickness at end diastole, and left ventricular posterior wall thickness at end systole were assessed. The cardiac function indices, including end diastolic volume, end systolic volume, stroke volume, ejection fraction, and fractional shortening were also measured. B-mode and guided M-mode echocardiographic examination of healthy donkeys revealed that both the interventricular septum thickness and the left ventricular posterior free wall were greater during systole than diastole. However, the left ventricular dimension during diastole was greater than systole. Furthermore, the recorded data of cardiac function indices, including end diastolic volume, end systolic volume, stroke volume, ejection fraction, and fractional shortening using B-mode echocardiography were closer to those recorded by guided M-mode echocardiography. To our knowledge, this is the first Egyptian study to report the echocardiographic reference ranges of donkeys (E. asinus) based on the probability theory and statistics, the coefficient of variation. The results of the present study can be used as standard and reference values for further echocardiographic studies in donkeys and represent a step in the identification, interpretation, and evaluation of cardiovascular disorders in such animals.  相似文献   

14.
Background: Noninvasive assessment of left ventricular (LV) function is incompletely studied in horses.
Objectives: The goals of this study were to investigate the feasibility, techniques, and reliability of tissue Doppler imaging (TDI) for characterization of LV radial wall motion in healthy horses.
Animals: Three Standardbreds, 3 Thoroughbreds; age 8–14 years; body weight 517–606 kg.
Methods: Repeated echocardiographic examinations were performed by 2 observers in unsedated horses using TDI. Test reliability was determined by estimating measurement variability, within-day interobserver variability, and between-day interobserver and intraobserver variability of all echocardiographic variables. Variability was expressed as coefficient of variation (CV) and the absolute value below which the difference between 2 measurements will lie with 95% probability.
Results: Assessment of LV radial wall motion by TDI was feasible in all horses. Measurement variabilities were very low (CV < 5%) to low (CV 5–15%) for most variables. Within-day interobserver variability as well as between-day interobserver and intraobserver variabilities were low to moderate (CV 16–25%) for most variables. All pulsed-wave TDI variables of systolic LV function showed very low to low variability, whereas some of the variables of LV diastolic and LA function showed moderate to high (CV > 25%) variability. Pulsed-wave TDI variables appeared more reliable than color TDI variables.
Conclusions and Clinical Importance: Measurement of TDI indices of LV function is feasible and reliable in adult Standardbred and Thoroughbred horses. The clinical relevance of LV function assessment by TDI remains to be determined.  相似文献   

15.
Thirty-five young cats were studied by echocardiography from the 2nd to 12th weeks of life to analyze correlation between body weight, body surface area, age and heart rate with fourteen echocardiographic parameters. There was a positive linear correlation (r = 0.49-0.78) between the independent variables (body weight, body surface area, age) and left ventricular wall thickness and diameter, aortic diameter and left atrial diameter, whereas there was a negative correlation (r = -0.39 and r = -0.43) between the heart rate and left ventricular diameter during systole and diastole. No linear dependence of the fractional shortening, ejection fraction, percentage thickening of the interventricular septum and left ventricular posterior wall, LA/AO ratio, and the ratio IVSED/LVWED to the independent variables was observed.  相似文献   

16.
Normal cats and cats with congestive cardiomyopathy (CCM) and hypertrophic cardiomyopathy (HCM) were examined using M-mode echocardiography to determine its diagnostic capabilities. Sixteen normal cats were examined to verify previously reported data and to add further echocardiographic inforamtion (left atrial/aortic root ratio, left posterior wall thickness at end systole and end diastole, amplitude of mitral valve excursions, and velocity of valve opening and closure) to aid in differential diagnosis. Significant (p<0.05) changes were detected between the normal cats and those with cardiomyopathy. In each type of cardiomyopathy, alterations in left atrial dimension, left atrial/aortic root ratio, left ventricular dimension, left ventricular wall thickness and percentage of ventricular dimensional change were identified. Altered mitral valve motion was found with HCM. Echocardiography was found to be an accurate technique for definitive diagnosis of feline cardiomyopathy.  相似文献   

17.
ECHOCARDIOGRAPHIC REFERENCE VALUES IN WHIPPETS   总被引:1,自引:0,他引:1  
The aim of the study was to establish reference echocardiographic values for whippets, to compare these values with previously published reference values for the general dog population, and to determine whether there is an influence of gender and breeding lines on echocardiographic measurements. Echocardiographic parameters from 105 apparently healthy whippets without cardiac symptoms were used to establish reference values for the breed and to compare these values with two previously reported reference ranges. The coefficients of the allometric equation Y= aM(b), useful to reconstruct normal M-mode and two-dimensional average values for whippets of varying weights, were calculated, as well as the lower and upper limits of the 95% prediction interval. First, we found that whippets have a significantly larger left ventricular diameter, increased left ventricular wall, and interventricular septum thickness than expected, in diastole as well as in systole. Fractional shortening was significantly lower than the reference value. Second, comparing males and females, taking body weight differences into account, females had a significantly larger left ventricular diameter in diastole and systole. Minor differences were found between racing and show pedigree dogs. In conclusion, the results of this study confirm that breed-specific reference values are needed in echocardiography. In whippets, the values found in this study can be used as references in order to avoid overinterpretation of cardiac dilation, hypertrophy, and/or decreased contractility in these dogs.  相似文献   

18.
OBJECTIVE: To assess the feasibility, describe the techniques, and determine the reliability of transthoracic echocardiography for characterization of left atrial (LA) size and LA mechanical function in horses. ANIMALS: 6 healthy adult horses. PROCEDURES: Repeated echocardiographic examinations were performed independently by 2 observers in standing, unsedated horses by use of 2-dimensional echocardiography, pulsed-wave flow Doppler, and tissue Doppler imaging (TDI) techniques. Test reliability was determined by estimating measurement variability, within-day interobserver variability, and between-day inter- and intraobserver variability of all echocardiographic variables. Variability was expressed as the coefficient of variation (CV) and the absolute value below which the difference between 2 measurements will lie with 95% probability. RESULTS: Most echocardiographic variables of LA size had low overall variability (CV, < 15%). Among the 2-dimensional indices of LA mechanical function, area-based and volume-based ejection phase indices had moderate between-day variability (CV usually < 25%). Transmitral Doppler flow indices were characterized by low to high between-day variability (CV, 6% to 35%). The TDI wall motion velocities had high between-day variability (CV, > 25%), whereas most TDI-derived time intervals had low variability (CV, < 15%). CONCLUSIONS AND CLINICAL RELEVANCE: LA size and mechanical function can be reliably assessed in standing, unsedated horses by use of 2-dimensional echocardiography, transmitral blood flow velocity profiles, and analyses of LA wall motion by use of TDI. These results may provide useful recommendations for echocardiographic assessment of LA size and function in horses.  相似文献   

19.
BACKGROUND: Diagnosis of cardiomyopathy of cats is based on 2-dimensional (2D) echocardiography. However, circulating fluid volume largely determines diastolic cardiac chamber dimensions, and reduced diastolic volume in other species results in what has been called "pseudohypertrophy of the ventricular myocardium." HYPOTHESIS: Altered hydration produces changes on 2D echocardiography that may confound the diagnosis or severity assessment of cardiomyopathy of cats. ANIMALS: Ten normal colony-sourced mixed breed cats were included. METHODS: Cats were examined by echocardiography at baseline and at completion of 3 protocols (volume depletion and maintenance-rate and anesthetic-rate IV fluid administration) applied in randomized crossover design with a 6-7 day washout period. RESULTS: Volume depletion increased diastolic left ventricular interventricular septal (IVSd) and free wall diameter (4.5 +/- 0.4 to 5.8 +/- 0.6 mm; P < .001) with wall thickness exceeding 6 mm in 4 cats. Diastolic left ventricular internal diameter (LVIDd) decreased, and reduction in systolic left ventricular internal diameter (LVIDs) produced end-systolic cavity obliteration in 7 cats. Left-atrial-to-aortic-root ratio (LA: Ao, 1.4 +/- 0.2 to 1.2 +/- 0.1, P < .05) and left atrial area in diastole (LAAd) decreased with volume depletion. Maintenance-rate IV fluid administration increased LAAd and fractional shortening (FS%). Anesthetic-rate IV fluid administration increased LVIDd, FS%, LAAd, and LA:Ao ratios (to 1.7 +/- 0.1, P < .01), producing an LA: Ao ratio above normal limits in 6 cats. A systolic heart murmur developed with administration of fluid at maintenance (n = 1) and anesthetic rates (n = 6). CONCLUSIONS: Altered hydration status produces changes in the echocardiographic examination of normal cats that may lead to an erroneous diagnosis of cardiomyopathy or mask its presence. Hydration status should be considered during echocardiographic examination in cats.  相似文献   

20.

Background

Maine coon cats have a familial disposition for developing hypertrophic cardiomyopathy (HCM) with evidence of an autosomal dominant mode of inheritance [1]. The current mode to diagnose HCM is by use of echocardiography. However, definite reference criteria have not been established. The objective of the study was to determine the prevalence of echocardigraphic changes consistent with hypertrophic cardiomyopathy in Swedish Maine coon cats, and to compare echocardiographic measurements with previously published reference values.

Methods

All cats over the age of 8 months owned by breeders living in Stockholm, listed on the website of the Maine Coon breeders in Sweden by February 2001, were invited to participate in the study. Physical examination and M-mode and 2D echocardiographic examinations were performed in all cats.

Results

Examinations of 42 asymptomatic Maine coon cats (10 males and 32 females) were performed. The age of the cats ranged from 0,7 to 9,3 years with a mean of 4,8 ± 2,3 years. Four cats (9,5%) had a diastolic interventricular septal (IVSd) or left ventricular free wall (LVPWd) thickness exceeding 6,0 mm. In 3 of these cats the hypertrophy was segmental. Two cats (4,8%) had systolic anterior motion (SAM) of the mitral valve without concomitant hypertrophy. Five cats (11,9%) had IVSd or LVPWd exceeding 5,0 mm but less than 6,0 mm.

Conclusion

Depending on the reference values used, the prevalence of HCM in this study varied from 9,5% to 26,2%. Our study suggests that the left ventricular wall thickness of a normal cat is 5,0 mm or less, rather than 6,0 mm, previously used by most cardiologists. Appropriate echocardiographic reference values for Maine coon cats, and diagnostic criteria for HCM need to be further investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号