首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
The aim of this study was to develop a competitive inhibition ELISA (CI-ELISA) for detection of antibodies to bovine viral diarrhea virus (BVDV) using the helicase domain of NS3 (non-structural) protein and monoclonal antibody (MAb) against it and to estimate its sensitivity and specificity using two commercial ELISA kits as independent references. The 45-kDa helicase domain of NS3 protein of BVDV was expressed in Escherichia coli and 18MAbs were developed against it. MAb-11G8 was selected for use in CI-ELISA on the basis of maximum inhibition (90%) obtained with BVDV type 1 infected calf serum. Based on the distribution of percent inhibition of known negative sera (n=166), a cut-off value was set at 40% inhibition. In testing 914 field serum samples of cattle (810) and buffaloes (104), the CI-ELISA showed a relative specificity of 95.75% and 97.38% and sensitivity of 96% and 94.43% with Ingenesa kit and Institut Pourquier kit, respectively. This study proved that the use of helicase domain of NS3 (45-kDa) is equally good as the whole NS3 protein (80-kDa) used in commercial kits for detection of BVDV antibodies in cattle and buffaloes.  相似文献   

2.
A microtitre ELISA has been established for the quantitation of antibodies to bovine viral diarrhoea virus (BVDV). Single dilutions of sera were assayed and units of antibody were calculated from a standard curve. In order to detect the maximum number of responding animals both IgG1 and IgG2 antibody should be assayed, although detection of IgG1 alone was nearly as effective. The ELISA was as sensitive as the virus neutralization test for detection of antibody; comparison of an ELISA that detected IgG1 plus IgG2 antibody to BVDV with the virus neutralization test gave a correlation coefficient (r) of 0.89 (P less than 0.001 for 95 compared sera). Although similar amounts of IgG1 and IgG2 antibodies were present in sera from both experimentally- and naturally-infected cattle, antibody to BVDV in colostrum and in the sera from young calves was predominantly IgG1. The number of adult cows with antibody was 40 out of 41 while 36 of 44 calves reared in a beef unit were found to have produced antibody by the time they were 31.5 weeks old, an indication of the high prevalence of BVDV in the cattle population.  相似文献   

3.
To detect Bovine Virus Diarrhoea Virus (BVDV)-specific antibodies in cattle serum, plasma and bulk milk, a simple, reliable and rapid blocking ELISA ("Ceditest") has been developed using two monoclonal antibodies ("WB112" and "WB103") directed to different highly conserved epitopes on the non-structural peptide NS3 of pestiviruses. The test can be performed at high reproducibility using undiluted samples. In testing 1000 field serum samples, the ELISA showed a specificity and a sensitivity relative to the virus neutralization test of 99% and 98%, respectively. The blocking ELISA is able to detect specific antibodies in serum obtained 12 days after an acute infection and in serum of vaccinated and challenged animals. A frequency distribution diagram, obtained by testing almost 1800 random Dutch field serum samples, showed a clear separation between a negative population (maximum frequency of the % inhibition at -5%) and a positive population (maximum frequency of the % inhibition at 95%). Based on these data, the prevalence of seropositive animals was 65% (95% confidence interval: 63%-67%). By exchanging plasma- and bulk milk samples between two laboratories (The Netherlands and Denmark), a good overall agreement was found between results obtained with the Ceditest and those obtained with the Danish blocking ELISA as used in the Danish BVDV eradication programme. The results indicate that BVDV infections can reliably be diagnosed by the Ceditest ELISA and that the test is suitable for use in large scale screening and eradication programmes.  相似文献   

4.
本研究旨在建立一种检测牛病毒性腹泻病毒(BVDV)抗体的间接ELISA方法。将BVDV的非结构蛋白NS3基因克隆到原核表达载体pET-32a中进行表达,将纯化后的蛋白作为包被抗原,优化ELISA条件,建立了BVDV抗体间接NS3-ELISA检测方法,并对该方法的特异性、敏感性和重复性进行检测,结果均较好。用所建立的NS3-ELISA方法检测从广西各牛场采集的475份牛血清样品,检出率为24.8%,与商品化试剂盒比较,符合率为97%。结果表明,本研究建立的NS3-ELISA方法简便、快捷,可大批量检测,适用于BVDV的诊断、抗体水平监测及流行病学调查。  相似文献   

5.
The sensitivity and specificity of an enzyme-linked immunosorbent assay (ELISA) to detect antibodies; to Babesia bovis was evaluated in 1000 sera from Holstein heifers. Five hundred of them were from cattle naturally or experimentally infected with B. bovis and 500 from uninfected heifers born and raised in a region free of the vector of cattle babesiosis. Additionally, the ELISA was evaluated and compared with an indirect immunofluorescent antibody (IFA) test in 374 heifers inoculated with different kinds of B. bovis antigens in four trials. The cross-reaction was also evaluated in 50 heifers infected with Babesia bigemina and 50 heifers infected with Anaplasma marginale. The mean percentage positivity of negative sera in relation to the ELISA strong positive sera was 8%. The seropositive/seronegative cutoff point was set as twice the mean percentage positivity of negative cattle sera ( = 16%). The sensitivity of the ELISA was 98% with a 95% confidence interval (CI) of 96–99%. The specificity was 95% (CI 93–97%). The agreement was 97% and the kappa value was 0.93. The predictive values of positive and negative results were 95% and 98% respectively. ELISA showed a similar sensitivity to that of the IFA test to detect antibodies to different B. bovis antigens. Its sensitivity ranged from 97.1% to 100% (CI 89–100%), while the sensitivity of the IFA test ranged from 92.8% to 100% (CI 83–100%). ELISA cross-reacted in 8% and 6% of the sera carrying B. bigemina and A. marginale antibodies, respectively, while the IFA showed 4% cross-reaction in each situation. The ELISA evaluated has the advantages of a proper sensitivity, objectivity and capacity to be adapted to test large number of samples in a short period of time. The results indicate that the ELISA is a suitable replacement for the IFA test to detect B. bovis antibodies in cattle sera, especially in epidemiological studies.  相似文献   

6.
Bovine viral diarrhea virus (BVDV) affects cattle populations causing clinical signs that range from subclinical immunosuppression to severe reproductive and respiratory problems. Detection and removal of persistently infected (PI) calves is the single most important factor for control and eradication of BVDV. Current testing strategies to detect PI calves rely heavily on immunohistochemistry (IHC) and a commercially available antigen capture ELISA (ACE) assay. These viral assays depend on 1 or 2 monoclonal antibodies which target the E(rns) glycoprotein of BVDV. The sensitivity and specificity of these two tests have been reported previously. The purpose of this research was to characterize a strain of BVDV (AU501) that was undetectable using IHC and ACE based on a single monoclonal antibody, but was consistently detected in samples from a Holstein steer using virus isolation and PCR testing. Sequencing of this AU501 viral isolate revealed a unique mutation in the portion of the genome coding for the E(rns) glycoprotein. This unique field strain of BVDV demonstrates the risk of relying on a single monoclonal antibody for detection of BVDV. Multiple testing strategies, including polyclonal or pooled monoclonal antibodies that detect more than one viral glycoprotein may be necessary to detect all PI calves and facilitate eradication of BVDV.  相似文献   

7.
An ELISA was developed for the detection of Fasciola hepatica antibody in serum of cattle. The assay was applied to sera from 258 naturally infected cattle, 256 non-infected cattle and six calves experimentally infected with F. hepatica. The diagnostic sensitivity and specificity of the ELISA test was 98% (95% confidence intervals, 96-100%) and 96% (95% confidence intervals, 93-98%) respectively at a cut-off value of 15% positivity. The results using sera from the experimentally infected calves showed that antibodies were first detected 2-4 weeks after infection. The ELISA test was also compared to the commercially available Bio-X bovine F. hepatica ELISA kit. A subset of 39 positive sera and 47 negative sera were selected from the samples used to evaluate the in-house test. The results indicated that the agreement between the two tests was almost perfect (k statistic=0.82).  相似文献   

8.
AIM: To assess the ability of two commercial bovine viral diarrhoea (BVD) virus (BVDV) antigen-capture enzyme-linked immunosorbent assays (ELISAs) to detect virus in serum and skin biopsies. METHODS: Thirty cattle persistently infected (PI) with BVDV were identified using routine diagnostic laboratory testing. Additional ear-notch skin biopsies and blood samples were collected from these animals to confirm the diagnosis, and from 246 cohorts, to determine their BVDV status. Skin biopsies were soaked overnight in buffer and the eluate collected. All sera and eluate were tested using two commercially available ELISAs for detecting BVDV antigen, and a subsample of positive and negative sera was tested using a polymerase chain reaction (PCR) test. A study was also performed to ascertain the risk of cross contamination occurring during the collection and processing of skin biopsies. RESULTS: Both serum and skin samples tested using either ELISA resulted in the detection of all cattle identified as PI and no non-infected cattle were incorrectly classified as infected using either method. Agreement between all assays (ELISAs, whether performed on serum or skin, and PCR) was 100%. No cross-contamination of skin samples between animals was evident using routine biopsy methods. CONCLUSIONS: Viraemic cattle infected with BVDV were accurately identified using either of the two commercial ELISAs evaluated on either serum or skin samples. CLINICAL RELEVANCE: Either skin biopsies or serum samples can be collected from cattle to determine their BVDV status. This should overcome problems in accurately identifying the infection status of young calves in which colostral antibodies might interfere with the antigen-capture ELISA.  相似文献   

9.
The performance characteristics of a blocking ELISA test applied to serum and individual milk for the detection of antibodies to bovine viral diarrhoea virus (BVDV) were assessed using 1189 matched milk/serum samples collected from cows of 42 dairy herds located in Brittany (west of France). This test was based on a monoclonal antibody directed against non-structural protein NS2-3 of pestiviruses. All tests were performed blind. For each type of sample, negative/positive cut-off values were determined using receiver operating characteristic (ROC) analysis. Sensitivity and specificity were estimated using the virus neutralisation test as a reference. For sera, the ROC analysis provided a negative/positive inhibition percentage cut-off value of 50% giving a sensitivity and a specificity of 96.9 and 97.8%. For individual milk samples, the cut-off was fixed at 30%, leading to a sensitivity and a specificity of 96.9 and 97.3%. Using this test, a good overall agreement was found between results obtained on matched milk/serum samples (Kappavalue=0.95). The present results indicate that this blocking ELISA test is reliable enough for use in a mass screening and control scheme on BVDV.  相似文献   

10.
为建立检测牛传染性鼻气管炎病毒(IBRV)血清抗体的阻断ELISA方法,本研究以经蔗糖密度梯度离心法纯化的IBRV作为免疫原制备1株单克隆抗体(MAb),命名为cp-1-1。经间接ELISA、IFA和western blot鉴定,该MAb与IBRV呈阳性反应,与牛病毒性腹泻病毒(BVDV)及牛副流感病毒3型(BPIV3)呈阴性反应,具有较强的特异性。质谱分析结果显示MAb cp-1-1识别的表位位于IBRV VP8蛋白。以纯化的IBRV作为包被抗原、MAb cp-1-1作为检测抗体,建立检测IBRV血清抗体的阻断ELISA方法。该检测方法的抗原包被量为0.89μg/孔,样品稀释度为12,检测抗体MAb量为1.3μg/孔,二抗稀释度为15000。利用50份IBRV抗体呈弱阳性的牛血清(中和抗体效价为14~116)作为标准参考血清,确定该检测方法的阻断率Cut Off值为52.06%,即阻断率高于52.06%时判为阳性,低于52.06%时判为阴性。阻断ELISA方法特异性试验显示仅IBRV阳性血清检测为阳性,而BVDV、BPIV3、牛腺病毒3型(BADV-3)和O型口蹄疫病毒(O-FMDV)阳性牛血清均检测为阴性,表明该方法具有较强的特异性;该方法可检测的最低中和抗体效价为14,与病毒中和试验的敏感性一致,表明该方法具有较高的敏感性;重复性试验显示该方法批内、批间变异系数均小于10%,显示较好的重复性。对130份现地牛血清检测结果显示,该方法与病毒中和试验的符合率为98.46%。用该方法对某牛场接种IBRV灭活疫苗的牛血清进行检测,抗体阳性率为99.51%(205/206)。另外,采用该方法对我国8个省(市、自治区)的801份牛血清进行检测,IBRV的抗体阳性率为41.6%(333/801)。本研究建立的阻断ELISA方法可以用于IBRV疫苗免疫监测和血清流行病学调查,为我国IBR的防控提供技术支持。  相似文献   

11.
12.
An indirect enzyme-linked immunosorbent assay (I.ELISA) is described for detection of bovine serum antibody to epizootic hemorrhagic diseases of deer virus (EHDV). Serum samples, at a dilution of 1:200, were incubated with group-specific EHDV antigens, pre-adsorbed to microtiter plates. Bound antibodies were detected by a murine monoclonal antibody to bovine immunoglobulin (Ig)G1 (heavy-chain specific) conjugated with horseradish peroxidase. The performance of the I.ELISA in detecting antibodies to EHDV in sequential serum samples from calves experimentally infected with serotypes 1,2,3 and 4 was evaluated. The I.ELISA detected EHDV antibodies from 14 days postinfection when seroconversion by the standard agar gel immunodiffusion (AGID) test was also evident. The group-specific antibodies to EHDV increased exponentially during the first two to four weeks postinfection and remained relatively stable for about 12 months in some calves. Unlike observations with the AGID test, no reaction was seen in the I.ELISA between blue-tongue virus (BTV) antigen and sera from calves given a single dose of EHDV. The performance of the I.ELISA and AGID were compared using 3,135 AGID negative bovine field sera from herds in Ontario, Alberta and British Columbia and 130 AGID positive samples collected from cattle in 1987 and 1988 during and after outbreaks of EHD in the Okanagan Valley, British Columbia. The specificity and sensitivity of the assay relative to the AGID test were 99.3% and 91.5% respectively, with an overall agreement of 99.0% between the tests.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

13.
When six cattle persistently infected with bovine virus diarrhoea virus (BVDV) were inoculated with lymphocytes infected with bovine leukosis virus (BLV), a depressed antibody response to BLV was observed by ELISA which was due to a decrease in IgG1 synthesis. The ELISA was more sensitive and more reliable than the agar gel immunodiffusion (AGID) test in detecting BLV infection in cattle persistently infected with BVDV. Decreased antibody responses were manifested in the AGID test by negative, inconclusive or weakly positive reactions: only two of the six cattle developed antibodies that generated positive AGID reactions.  相似文献   

14.
AIMS: To assess the sensitivity and specificity of a bulk tank milk (BTM) antibody enzyme-linked immunosorbent assay (ELISA) to detect likely infection of a dairy herd with bovine viral diarrhoea virus (BVDV). The ELISA was subsequently used to estimate the prevalence of likely infected herds in parts of the North Island of New Zealand. METHODS: BTM samples from 724 randomly selected dairy herds in the Waikato, Bay of Plenty and Northland regions of New Zealand were tested for BVDV antibodies. From this group, 20 herds were again randomly selected from each of the quartiles of the ELISA percentage inhibition (%INH) result. From each participant herd, serum from 15 randomly selected calves aged 6-18 months and 15 cows was collected and tested using an indirect blocking ELISA for BVDV antibodies. RESULTS: Among serum results from calves from 50 herds available for analysis, 34 (68%) herds were classified as likely non-infected (0-3 seropositive among 15 calves) and 16 (32%) as likely infected (5-15 seropositive among 15 calves). Receiver-operator characteristic (ROC) analysis identified an optimal cut-off for BTM of 80%INH associated with 81% sensitivity and 91% specificity for likely herd infection. The prevalence of BVDV antibodies in cows within herds and %INH for BVDV in bulk milk were positively correlated (p<0.01). The association between bulk milk %INH and the prevalence of BVDV antibodies in calves was stronger than the same association in cows. Based on the threshold of 80%INH, the 95% confidence interval (CI) for prevalence of likely infection in the 724 herds in the Waikato, Bay of Plenty and Northland regions of New Zealand was 12-17%. Vaccination against BVDV was not significantly associated with the likely infection status of the herd based on prevalence of BVDV antibodies among calves. CONCLUSION: An ELISA test result for BVDV antibodies in BTM >/=80%INH can be used as a threshold to indicate the presence of likely infection with BVDV in dairy herds in New Zealand, with 81% sensitivity and 91% specificity.  相似文献   

15.
Neosporosis is of alarming economic concern in the cattle industry. The effectiveness of diagnostic tests for detecting specific antibodies against Neospora caninum is hampered by potential cross-reaction with other coccidia. Use of a single specific antigen might improve test specificity. An indirect enzyme-linked immunosorbent assay (ELISA) was developed using the truncated protein NcSRS2 expressed in Escherichia coli. The ELISA results were compared with those of the indirect fluorescence antibody test (IFAT). Receiver Operating Characteristic (ROC) and Tests in the Absence of a Gold Standard (TAGS) analysis revealed an assay having 96% specificity and 95% sensitivity when applied to 145 positive and 352 negative sera from two distinct cattle populations. Using OD ≤ 0.095 as the cut-off point, the assay's negative and positive predictive values ranged from 98.8% to 50.8% and from 58.8% to 99.1%, respectively, depending on neosporosis prevalence in a given area. The novel ELISA-NcSRS2 format described in the present report constitutes a specific and sensitive method for detecting N. caninum in cattle.  相似文献   

16.
An enzyme-linked immunosorbent assay (ELISA) for antibodies to Babesia bovis was evaluated in comparison with the indirect fluorescent antibody test (IFAT) in Australia and Zimbabwe. Positive and negative threshold values for the ELISA were set using sera from cattle of known infection status. Sensitivity and specificity estimates for the ELISA based on 158 positive sera from cattle experimentally infected with Australian isolates of B. bovis and 318 negative sera collected from B. bovis-free herds in Australia were 100% and 99.4%, respectively. The specificity of the assay in Africa, based on 328 sera from B. bovis-free herds in Kenya and South Africa, was 99.7%. The ELISA was compared with the IFAT using sequential sera from 16 calves experiencing primary B. bovis infections, and a total of 777 field sera collected from B. bovis-endemic herds in Australia and Zimbabwe. In primary infections, the ELISA and IFAT detected antibodies at or about the same time. With sera from endemic herds, the performance of the ELISA was at least comparable with that of the IFAT. Two hundred and fourteen of 221 sera that were negative by IFAT, were negative by ELISA, and 428 of 439 sera that were clearly positive by IFAT were positive by ELISA. Of 117 sera that gave equivocal (suspect or weak positive) results in the IFAT, 20 were positive by ELISA, 7 were suspect and 90 were negative. We conclude that the ELISA will be useful for epidemiological studies on B. bovis in Australia and Zimbabwe, and probably elsewhere.  相似文献   

17.
OBJECTIVE: To compare a recently developed recombinant MSP-5 competitive inhibition ELISA with a card agglutination test for detection of antibodies to Anaplasma marginale and Anaplasma centrale in Australian cattle. MATERIALS AND METHODS: The ELISA was compared with the card agglutination test using 208 sera from cattle in Anaplasma-free herds, 86 sera from cattle experimentally infected with A marginale or A centrale and 757 sera from cattle in areas endemic for A marginale. RESULTS: The specificity of the ELISA, based on testing 208 sera from cattle in Anaplasma-free areas, was 99.5%, and the sensitivities for detection of antibodies to A marginale and A centrale in sera from the experimentally infected cattle were 98.0% and 100%, respectively. For the same sets of sera, the specificity of the card agglutination test was 98.6% and the sensitivities for detection of antibodies to A marginale and A centrale were 98.0% and 100%, respectively. For the 757 sera collected from cattle in areas endemic for A marginale, the agreement between the ELISA and the card agglutination test depended on the positive threshold selected for the ELISA. The maximum achievable agreement was 91.5% (kappa = 0.73; 95% confidence interval 0.66, 0.79). CONCLUSION: We conclude that the competitive inhibition ELISA is a useful alternative to the card agglutination test for detection of A marginale or A centrale infection in cattle. The assay should be particularly useful for epidemiological applications such as prevalence studies and control programs.  相似文献   

18.
Kang YJ  Jo JO  Cho MK  Yu HS  Cha HJ  Ock MS 《Veterinary parasitology》2012,186(3-4):480-485
A serological survey for Neospora caninum and Besnoitia besnoiti was carried out in beef and dairy cattle in South Australia. Serum samples of dairy cattle (n=133) from 9 properties and tank milk samples from a further 122 dairy herds were tested. An additional 810 sera from beef cattle from 51 properties were also tested. Testing at the individual animal level by IDEXX NEOSPORA X2 Ab test ELISA revealed a low prevalence of N. caninum antibodies of only 2.7% (95% CI; 1.6-3.7%) sera positive, as did the milk testing that showed 2.5% (95% CI; 1.4-3.6%) of tank milks being positive. At the herd level, 29.4% (95% CI; 16.9-41.9%) of beef, and 44.4% (95% CI; 12.0-76.9%) of dairy cattle herds showed serum antibodies. The highest within-herd prevalence in beef was 20% and 25%in dairy, which explains the low herd prevalence in dairy detected by bulk milk testing. Testing for B. besnoiti antibodies by PrioCHECK(?) Besnoitia Ab 2.0 ELISA initially identified 18.4% (95% CI: 15.8-21.0%) of 869 individual cattle sera as positive by ELISA at the manufacturer's suggested cut-off threshold (15 PP). Additional tests by immunoblot and IFAT, however, could not confirm any of the ELISA results. The use of a higher (40 PP) threshold in the ELISA is suggested to improve specificity. There is thus no evidence of B. besnoiti infection in South Australian cattle.  相似文献   

19.
Serum samples from healthy dairy and beef cattle, living in tick-infested areas of Connecticut, USA, were analyzed by polyvalent enzyme-linked immunosorbent assays (ELISA), indirect fluorescent antibody (IFA) staining methods, or Western blot procedures to detect antibodies to tick-borne agents. Of the 80 sera tested by ELISA with whole-cell or 10 separate recombinant antigens (fusion proteins) of Borrelia burgdorferi sensu stricto, 57 (71%) were positive to 1 or more antigens, while 36 (45%) reacted to whole-cell antigens by IFA staining methods. Three (4%) of 80 samples had antibodies to Anaplasma phagocytophilum. There were antibodies to outer surface protein (Osp) A, OspB, OspC, OspE, OspF, protein (p) 41-G, p35, p37, and VlsE antigens of B. burgdorferi, but there was no reactivity to the p39 antigen by ELISA. Western immunoblots of a subset of 9 sera verified antibody presence in all samples and showed distinct reactivities to multiple proteins having molecular masses of about 31 kilodaltons (kDa), 34 kDa, 35 kDa, 41 kDa, and 83/93 kDa. High specificity (97%) was noted when 16 cattle sera containing antibodies to Leptospira interrogans serovars, Brucella sp., Anaplasma marginale, or A. phagocytophilum were tested by ELISA with separate whole-cell or recombinant B. burgdorferi antigens. An ELISA and Western blot analyses can be used to confirm the exposure of cattle to B. burgdorferi.  相似文献   

20.
A blocking (B) dot enzyme-linked immunosorbent assay (ELISA), using a monoclonal antibody (mAb) against a group specific antigen of bluetongue virus (BTV) is described for the detection of BTV antibodies to BTV in cattle sera. Dots of BTV antigens were adsorbed to nitrocellulose (NC) strips and/or NC mounted in the windows of dipsticks. After blocking the remaining sites of the NC paper with milk powder solution and immersion in the test sample, the NC strips and dipsticks were exposed to mAb. Bound mAb was detected with peroxidase conjugated anti-mouse IgG (H and L). In the absence of anti-BTV antibody in the test sample, BTV antigen sites were reactive with mAb as indicated by a brown colored dot in the presence of the enzyme substrate, hydrogen peroxide and diaminobenzidine. In the presence of sufficient anti-BTV antibodies no color reaction was observed. The performance of these assays in detecting anti-BTV antibody in field blood eluate samples, prepared from whole blood dried on filter paper, from 395 bluetongue-free cattle in Canada and 635 sentinel cattle in Florida, USA, was evaluated and compared with the standard competitive (C) ELISA. The specificity of the dipstick B-dot ELISA was identical to that of the C-ELISA in testing of BT-free Canadian cattle but not in the testing of samples from the sentinel cattle in Florida, resulting in values of 100% diagnostic and 88.9% relative specificity, respectively. Based on the C-ELISA, the specificity of the NC strip B-dot ELISA was low and in the same order as that of the dipstick assay.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号