首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
This paper reports the successful use of a half limb cast to treat prior failures in healing of a synovial hernia in a Thoroughbred yearling. The hernia was due to a nonhealing arthroscopy portal and was confirmed using ultrasonography and positive contrast arthrography to visualise the communication between the metacarpophalangeal joint and subcutaneous space. Surgery was performed 3 times, due to failure of healing of the joint capsule and recurrence of clinical signs. A half limb cast applied following the final surgery effected a repair. At 2 months post surgery there was no recurrence of the subcutaneous swelling and at 3 months post surgery a repeat positive contrast arthrogram confirmed healing of the hernia.  相似文献   

2.
3.
A 2-month-old intact female Rottweiler was presented for investigation of coughing and respiratory distress 9 d after an exploratory laparotomy for intestinal foreign body removal. Tracheal stenosis was suspected by radiography and confirmed with computed tomography (CT) and tracheoscopy. After 1 wk of medical management, clinical signs had resolved and the severity of the tracheal narrowing was markedly improved, as confirmed by radiography and tracheoscopy. Tracheal stenosis is a considerable complication of endotracheal intubation in veterinary medicine and may be medically managed, depending on the severity of the tracheal injury.Key clinical message:To our knowledge, this is the first clinical case report of tracheal stenosis resulting from endotracheal intubation in a dog and its resolution after medical management.  相似文献   

4.
BACKGROUND: Orotracheal intubation is a commonly performed procedure in the cat, but it is not without complications. Tracheal rupture has been reported in cats, but trauma to the arytenoids from intubation has not been documented. OBSERVATIONS: An otherwise healthy, 5-year-old male domestic shorthair cat presented for total ear canal ablation to resolve intractable otitis media and externa. The cat was premedicated with glycopyrrolate, hydromorphone, and acepromazine. Anesthesia was induced with diazepam and ketamine, and maintained with isoflurane in oxygen. During orotracheal intubation, the larynx was poorly visualized and excessive force was used to perform intubation. Subsequently, blood was observed in the larynx and laryngoscopy revealed a tear lateral to the patient's right arytenoid which had been created during intubation. The larynx was re-intubated normally and the cat suffered no obvious ill effects from the trauma to the larynx. CONCLUSIONS: Direct observation and proper technique must be employed during orotracheal intubation in cats in an attempt to avoid laryngeal trauma.  相似文献   

5.
A Dutch Warmblood, with no other underlying clinical disease, presented for surgical excision of a sarcoid tumour on the distal right pinna under general anaesthesia. At the end of the procedure, immediately before being moved to recovery, the horse became light and made repeated attempts to move whilst attached to the hoist. Anaesthesia was deepened with intravenous thiopental sodium (Thiopentone)1 and the horse was moved into the recovery room. The trachea was extubated with the cuff of the endotracheal tube inadvertently left partially inflated. Recovery was smooth and the horse stood uneventfully. The following day subcutaneous emphysema was noted along the neck and tracheoscopy revealed an abnormal dorsoventrally flattened trachea and a 5 cm tear in the dorsal aspect of the trachea. Symptomatic treatment resulted in progressive healing of the lesion and the horse recovered fully with no evidence of respiratory complications.  相似文献   

6.
7.
A 5‐year‐old pony presented with sudden onset of severe respiratory distress associated with tracheal rupture and peritracheal emphysema. Subsequent endoscopic examination revealed multiple mucosal nodules protruding into the tracheal lumen. Biopsy of the tracheal wall revealed well‐demarcated submucosal cartilagenous/osseous nodules. The appearance was considered to resemble tracheobronchopathia osteochondroplastica.  相似文献   

8.
Endotracheal intubation is commonly performed in horses undergoing general anaesthesia to avoid fluid aspiration and provide mechanical ventilation and inhalational anaesthetic agents. Secondary laryngeal and tracheal trauma following intubation is not rare. This case report describes the successful treatment of a horse with laryngeal and tracheal trauma secondary to intubation during myelography. Based on other clinical reports and clinical experience, movement of the endotracheal tube during myelography was considered the most likely cause of the damage. This case underscores the importance of monitoring horses for development of respiratory signs after general anaesthesia for computerised tomography and myelography.  相似文献   

9.
Tracheal rupture and stenosis are well-reported problems in human beings and cats following endotracheal intubation. However, this problem has been rarely reported in dogs. This case report describes a case of tracheal necrosis 5 days following endotracheal intubation in a dog associated with overinflation of the endotracheal tube cuff and multiple changes in position.  相似文献   

10.
11.
ObjectiveTo design and construct an affordable simulator of the cat larynx for training intubation maneuvers and to share the designs for its fabrication.Study designResearch and development study.AnimalsA domestic cat.MethodsThe cadaver of a cat, dead by natural causes, was frozen in sternal recumbency with the neck extended and the mouth wide open. A computed tomography image was acquired and used to construct a digital three-dimensional (3D) model of the pharynx and trachea. A digitally adapted model was 3D-printed and used to generate a silicone model of these structures, which was placed within a wooden container. The quality of the simulator was assessed by 46 veterinary anesthesiologists and veterinarians with experience in tracheal intubation maneuvers, and their opinions were obtained through an anonymous questionnaire.ResultsSeveral preliminary prototypes were assessed regarding stability, texture and cost. Finally, a silicone model of a cat larynx (LaryngoCUBE) was produced and encased in a wooden container. Results from the questionnaire showed high scores regarding anatomy, tissue texture and intubation maneuver realism, compared with the real procedure.Conclusionsand clinical relevance Use of LaryngoCUBE as a training tool may improve the skills of students and reduce the use of animals for teaching endotracheal intubation. Blueprints and computational models are provided online so that the simulator can be fully reproduced.  相似文献   

12.
OBJECTIVE: To compare the cardiorespiratory effects and incidence of gastroesophageal reflux with the use of a laryngeal mask airway (LMA) or endotracheal tube (ET) in anesthetized cats during spontaneous (SV) or controlled ventilation (CV). STUDY DESIGN: Prospective randomized experimental trial. ANIMALS: Thirty-two adult crossbred cats, weighing 2.7 +/- 0.4 kg. METHODS: The cats were sedated with intramuscular (IM) methotrimeprazine (0.5 mg kg(-1)) and buprenorphine (0.005 mg kg(-1)), followed 30 minutes later by induction of anesthesia with intravenous (IV) thiopental (12.5-20 mg kg(-1)). An ET was used in 16 cats and an LMA in the remaining 16 animals. Anesthesia was maintained with 0.5 minimum alveolar concentration (0.6%) of halothane in oxygen using a Mapleson D breathing system. Cats in both groups were further divided into two equal groups (n = 8), undergoing either SV or CV. Neuromuscular blockade with pancuronium (0.06 mg kg(-1)) was used to facilitate CV. Heart and respiratory rates, direct arterial blood pressure, capnometry (PE'CO2) and arterial blood gases were measured. Gastric reflux and possible aspiration was investigated by intragastric administration of 5 mL of radiographic contrast immediately after induction of anesthesia. Cervical and thoracic radiographs were taken at the end of anesthesia. Data were analyzed using anova followed by Student-Newman-Keuls, Kruskal-Wallis or Friedman test where appropriate. RESULTS: Values for PaCO2 and PE'CO2 were higher in spontaneously breathing cats with the LMA when compared with other groups. Values of PaO2 and hemoglobin oxygen saturation did not differ between groups. Gastroesophageal reflux occurred in four of eight and two of eight cats undergoing CV with ET or LMA, respectively. There was no tracheal or pulmonary aspiration in any cases. CONCLUSIONS AND CLINICAL RELEVANCE: The use of an LMA may be used as an alternative to endotracheal intubation in anesthetized cats. Although aspiration was not observed, gastric reflux may occur in mechanically ventilated animals.  相似文献   

13.
OBJECTIVE: To compare the doses of propofol required for insertion of the laryngeal mask airway (LMA) with those for endotracheal intubation in sedated dogs. STUDY DESIGN: Randomized prospective clinical study. Animals Sixty healthy dogs aged 0.33-8.5 (3.0 +/- 2.3, mean +/- SD) years, weighing 2.2-59.0 (23.4 +/- 13.6, mean +/- SD) kg, presented for elective surgery requiring inhalation anaesthesia. METHODS: Animals were randomly assigned to receive either a LMA or an endotracheal tube. Pre-anaesthetic medication was intravenous (IV) glycopyrrolate (0.01 mg kg(-1)) medetomidine (10 microg kg(-1)) and butorphanol (0.2 mg kg(-1)). Repeated IV propofol injections (1 mg kg(-1) in 30 seconds) were given until LMA insertion or endotracheal intubation was achieved, when the presence or absence of laryngospasm, the respiratory rate (fr) and the total dose of propofol used were recorded. RESULTS: The total propofol dose (mean +/- SD) required for LMA insertion (0.53 +/- 0.51 mg kg(-1)) was significantly lower than for endotracheal intubation (1.43 +/- 0.57 mg kg(-1)). The LMA could be inserted without propofol in 47% of dogs; the remainder needed a single 1 mg kg(-1) bolus (n = 30). Endotracheal intubation was possible without propofol in 3.3% of the dogs, 47% needed one bolus and 50% required two injections (n = 30). The f(r) (mean +/- SD) was 18 +/- 6 and 15 +/- 7 minute(-1) after LMA insertion and intubation, respectively. CONCLUSION AND CLINICAL RELEVANCE: Laryngeal mask airway insertion requires less propofol than endotracheal intubation in sedated dogs therefore propofol-induced cardiorespiratory depression is likely to be less severe. The LMA is well tolerated and offers a less invasive means of securing the upper airway.  相似文献   

14.
ObjectiveTo assess the effects of intravenous (IV) fentanyl on cough reflex and quality of endotracheal intubation (ETI) in cats.Study designRandomized, blinded, negative controlled clinical trial.AnimalsA total of 30 client-owned cats undergoing general anaesthesia for diagnostic or surgical procedures.MethodsCats were sedated with dexmedetomidine (2 μg kg–1 IV), and 5 minutes later either fentanyl (3 μg kg–1, group F) or saline (group C) was administered IV. After alfaxalone (1.5 mg kg–1 IV) administration and 2% lidocaine application to the larynx, ETI was attempted. If unsuccessful, alfaxalone (1 mg kg–1 IV) was administered and ETI re-attempted. This process was repeated until successful ETI. Sedation scores, total number of ETI attempts, cough reflex, laryngeal response and quality of ETI were scored. Postinduction apnoea was recorded. Heart rate (HR) was continuously recorded and oscillometric arterial blood pressure (ABP) was measured every minute. Changes (Δ) in HR and ABP between pre-intubation and intubation were calculated. Groups were compared using univariate analysis. Statistical significance was set as p < 0.05.ResultsThe median and 95% confidence interval of alfaxalone dose was 1.5 (1.5–1.5) and 2.5 (1.5–2.5) mg kg–1 in groups F and C, respectively (p = 0.001). The cough reflex was 2.10 (1.10–4.41) times more likely to occur in group C. The overall quality of ETI was superior in group F (p = 0.001), with lower laryngeal response to ETI (p < 0.0001) and ETI attempts (p = 0.045). No differences in HR, ABP and postinduction apnoea were found.Conclusions and clinical relevanceIn cats sedated with dexmedetomidine, fentanyl could be considered to reduce the alfaxalone induction dose, cough reflex and laryngeal response to ETI and to improve the overall quality of ETI.  相似文献   

15.
16.
17.
18.
OBJECTIVE: To investigate the effect of endotracheal tube cuff inflation pressure on the occurrence of liquid aspiration and tracheal wall damage. STUDY DESIGN: Prospective, randomized experimental study. ANIMALS: Ten healthy horses, weighing 535 +/- 55 kg. METHODS: Horses were anesthetized, orotracheally intubated, placed in dorsal recumbency, and maintained on isoflurane in oxygen with controlled ventilation for 175 +/- 15 minutes. The horses were randomly assigned to an endotracheal cuff pressure of 80-100 or 120 cm H2O. The cuff pressure was continuously monitored and maintained at a constant pressure. Methylene blue in saline was instilled proximal to the cuff. After euthanasia, the trachea was opened distal to the endotracheal tube tip to check for evidence of dye leaking past the cuff. The cervical trachea was then resected and opened longitudinally for gross and histologic examinations. RESULTS: No blue staining was found distal to the cuff in any horse. Visual examination of the tracheal mucosa revealed hyperemic and hemorrhagic lesions at the site of the cuff contact. Histologic changes included epithelium attenuation or erosion, submucosal neutrophilic infiltration, and submucosal hemorrhages. Lesions were absent or less extensive in the lower cuff pressure group as compared to the high cuff pressure group. CONCLUSIONS: The endotracheal tube cuff produced a seal sufficient to prevent leakage in both groups. Tracheal wall damage was more severe and occurred more frequently in the higher cuff pressure group. CLINICAL RELEVANCE: Tracheal mucosal damage induced by cuff inflation is pressure-dependent. Cuff pressure monitoring is recommended.  相似文献   

19.
ObjectiveTo assess the effects of two sizes of silicone endotracheal tubes with internal diameter 26 mm (ETT26) and 30 mm (ETT30) inflated to minimum occlusive volume on tracheal and laryngeal mucosa of adult horses anesthetized for 2 hours with isoflurane.Study designProspective, randomized, blinded, crossover experimental study.AnimalsA total of eight healthy adult mares.MethodsUpper airway endoscopy and ultrasound measurements of internal tracheal diameter were performed the day before anesthesia. Horses were anesthetized and orotracheally intubated with ETT26 or ETT30. Ease of intubation was scored. The cuff was inflated in 10 mL increments to produce a seal. Final volume of air used and intracuff (IC) pressure (measured by pressure transducer) were recorded. At the end of anesthesia, a manometer was used to measure IC pressure and these measurements compared against measurements from the pressure transducer. Laryngeal and tracheal mucosa were assessed via endoscopy and assigned a score 0–3 before anesthesia, and at 2 and 24 hours following extubation.ResultsData are from seven horses because one horse with laryngeal hemiplegia was excluded. Mean tracheal ultrasound measurement was 3.5 ± 0.4 cm. No significant differences were noted between endotracheal tube sizes for intubation score, IC pressures, inflation volumes or tracheal or laryngeal injury scores at any time point. IC pressure measured by manometer was slightly higher than that by transducer (+1.0 ± 2.8 mmHg).Conclusions and clinical relevanceResults identified no clear advantage of one endotracheal tube size over the other in the population of horses studied, when endotracheal intubation is properly applied and IC pressure is carefully monitored. However, given that ETT26 was associated with the highest observed IC pressures and the only observed incidents of tracheal circumferential erythema, the larger ETT30 may be the better choice in most cases where tracheal size is sufficient.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号