首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An enzyme-linked immunosorbent assay (ELISA) was developed for the fungicide thiram. Two types of haptens were synthesized. The first type exhibits the two symmetrical N-alkyl dithiocarbamate patterns of thiram with a spacer arm linked to one of the N-methyl terminal group. The second type exhibits one of the two symmetrical N-alkyl dithiocarbamate patterns of thiram with a variable-length spacer arm linked to one sulfur atom. Polyclonal antibodies suitable for thiram detection were obtained from immunization with an hapten of the first type, while haptens of the second type were used as coating antigens to develop a competitive ELISA against thiram. The IC(50) value for thiram was estimated to be 0.24 microg/mL, with a detection limit of 0.03 microg/mL. The assay seems to be thiram-specific since no or little cross-reaction with other dithiocarbamates were observed.  相似文献   

2.
A rapid and sensitive method for quantifying parthenolide in feverfew herb (Tanacetum parthenium) was developed that is significantly faster than those reported in the literature. The extraction system consisted of acetonitrile/water (90:10, v/v) in a bottle with stirring for 30 min. Both Soxhlet and bottle-stirring extractions were studied. Samples were analyzed using high-performance liquid chromatography with a Cosmosil C18-AR column (150 x 4.6 mm, 5 microm, 120 A). The mobile phase consisted of acetonitrile/water (55:45, v/v) with a flow rate of 1.5 mL/min and UV detection at 210 nm. Analysis time was 6 min, with a detection limit of 0.10 ng on column. The calibration curve was linear over a range of 0.160-850 microg/mL parthenolide with R(2) = 0.9999. Replicate tests indicated good reproducibility of the method with an RSD% = 0.88 (n = 10). Spike recovery of parthenolide was found to be 99.3% with an RSD% = 1.6 (n = 6).  相似文献   

3.
Enzyme-linked immunosorbent assay for microcystins in blue-green algal blooms   总被引:18,自引:0,他引:18  
A direct competitive enzyme-linked immunosorbent assay (ELISA) for the freshwater blue-green algal toxin microcystin (MCYST) in algae and water was developed. The assay involves coating anti-MCYST-variant leucine-arginine (LR) antibody to the ELISA plate and the use of MCYST-LR-peroxidase as the enzyme marker. The linear portion of the standard curve for MCYST in phosphate buffer containing saline (PBS) was 0.5-10.0 ng/mL (25-500 pg/assay). The minimum detection level for MCYST-LR was 0.20 ng/mL (10 pg/assay). Contaminated water could be directly used in the ELISA. The overall analytical recoveries for MCYST-LR added to water at levels of 1-20 ng/mL was 83.4%. For analysis of cellular MCYST, the toxin was first extracted from the algae with 0.1M ammonium bicarbonate, diluted with PBS to less than 0.5 mg dried algae/mL (less than 5.0 mg wet weight/mL) and directly used in the ELISA. C-18 reverse-phase Sep-Pak cartridges effectively adsorbed MCYST from the toxin-containing solutions. The toxin could be recovered from the cartridge by eluting with 60% methanol. Using this approach, an algae extract that was relatively free of MCYST was prepared and was used in a recovery study. The overall analytical recovery of MCYST added to the algae extract in the range of 0.25-20 ppm was 83% with a coefficient of variation of 11.9%. The detection limit for MCYST in dried algae was about 0.25-0.5 microgram/g (0.25-0.5 ppm) lyophilized algae sample. This method was applied for the analysis of several naturally occurring algal blooms. Limited samples were also analyzed for MYCST by liquid chromatography.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

4.
A reverse phase liquid chromatographic (LC) method has been developed for the assay of calcium pantothenate in commercial multivitamin tablet formulations and raw materials. The assay was validated according to the Pharmaceutical Manufacturers Association Quality Control HPLC Committee guidelines. The chromatographic system includes a C-18 column and a mobile phase consisting of 0.25M sodium phosphate buffer, pH 2.5, and acetonitrile (97 + 3 v/v). The column effluent is monitored by UV detection at 205 nm. The sample preparation involves only extraction in water followed by filtration. The method is stability-indicating with a detection limit of approximately 50 ng/mL of the calcium pantothenate in the samples. The system is linear from at least 0.02 to 0.10 mg/mL. The mean recovery of spiked placebos ranged from 98.7 to 99.8%. The within-day precision of the assay on finished products (N = 6) ranged from 0.3 to 2.0% CV. A system suitability criterion for resolution is based on the separation between calcium pantothenate and 2 closely eluting compounds, saccharin and a saccharin degradation product, 2-sulfamoylbenzoic acid.  相似文献   

5.
Two enzyme-linked immunosorbent assays (ELISA) for the insecticide azinphos-methyl have been optimized and characterized. Both ELISAs are based on monoclonal antibodies produced from an immunogen with a hapten containing a phthalimido moiety and on protein conjugates of heterologous ligands containing a 1,2,3-benzotriazine group. Assay I was performed in the conjugate-coated ELISA format and assay II in the antibody-coated format. Several physicochemical factors (ionic strength, pH, incubation times, and Tween 20 and BSA concentrations) that influence assay performance were studied and optimized. Regarding specificity, both monoclonal immunoassays highly cross-reacted with azinphos-ethyl and phosmet. Finally, both assays were applied to the analysis of azinphos-methyl in spiked real water samples. For assay I the sensitivity, estimated as the I(50) value, was 0.40 nM, with a practical working range between 0.10 and 1.75 ng/mL and a limit of detection of 0.05 ng/mL. For assay II the sensitivity was 1.01 nM, with a practical working range between 0.32 and 2.54 ng/mL and a limit of detection of 0.08 ng/mL.  相似文献   

6.
In this work, a polyclonal antibody for acrylamide (AA) was obtained by immunization of rabbits with N-acryloxysuccinimide (NAS) and keyhole limpet hemocyanin (KLH) conjugate. A direct enzyme-linked immunosorbent assay (ELISA) based on this antibody was developed with enhanced chemiluminescent (ECL) detection of AA in food samples. Assay conditions, such as concentrations of antibody and enzyme conjugate and competition time, were optimized. The effects of ionic strength and pH value were investigated. The optimized ECL-ELISA system allowed AA determination in a linear working range of 26.3-221.1 ng mL(-1) with an IC(50) value of 60.6 ng mL(-1) and a limit of detection of 18.6 ng mL(-1). Good recoveries with spiked food samples were obtained with a recovery range from 74.4 to 98.1%, and these results correlated well with those obtained using an HPLC method. This indicates that ECL-ELISA is applicable to the specific detection and routine monitoring of AA in food samples.  相似文献   

7.
A competitive enzyme-linked immunosorbent assay (ELISA) for pentachloronitrobenzene (PCNB), a fungicide and chemical intermediate, was developed using a polyclonal antiserum produced against a hapten-protein conjugate of pentachlorophenoxypropionic acid-bovine serum albumin (BSA). An indirect competitive ELISA of PCNB showed an IC50 of 37 ng/mL and a limit of detection (LOD) of 7 ng/mL. The ELISA can tolerate up to 10% (v/v) methanol, 5% (v/v) acetonitrile, or 5% (v/v) acetone without significant fluctuation of Amax and IC50. The assay sensitivity showed little change in a range of pH from 6 to 8 and concentrations of 0.05-0.2 M NaCl in the assay buffer. Very low cross-reactivities were observed for some structurally related compounds except for hexachlorobenzene (12%). The average recoveries of PCNB from fortified well water, river water, and soil samples were in ranges of 88-94, 80-91, and 70-81%, respectively. The correlations between the gas chromatographic and ELISA results were excellent (r 2 >or= 0.97, slopes from 0.86 to 1.10) for those fortified samples. The ELISA is a good alternative tool for monitoring PCNB residues in environmental samples.  相似文献   

8.
A competitive indirect enzyme-linked immunosorbent assay (ciELISA) for the organophosphorus insecticide acephate, O,S-dimethyl acetylphosphoramidothioate, was developed using a polyclonal antibody. Five different haptens mimicking the analyte were synthesized and conjugated with the carrier proteins bovine serum albumin (BSA) and keyhole limpet hemocyanin (KLH) by the N-hydroxysuccinimide active ester and diazotization methods. Polyclonal antibodies raised against hapten-KLH conjugates in rabbits and hapten-BSA conjugates as coating antigens were screened and selected for the assay in the homologous and heterologous ELISA systems. The effects of various assay conditions such as detergent, organic solvents, pH, and preincubation of the mixture of the polyclonal antibody and the analyte on the sensitivity were evaluated. The IC(50) value for acephate was 25 ng/mL in an optimized heterologous system using hapten-4-BSA as a coating antigen and a polyclonal antibody no. 8377 against hapten-1-KLH, showing the detection range of 5-140 ng/mL and the lowest detection limit of 2 ng/mL. The cross-reactivities of the structurally related organophosphorus insecticides, including the major metabolite of the analyte, methamidophos, were less than 1%. Recoveries from the analyte-fortified tap water, mulberry leaves, and lettuce samples in the assay were in the range of 72-121% by simple extraction, concentration, and dilution. These results indicate that the ELISA could be a convenient and supplemental analytical tool for monitoring acephate residues in environmental and agricultural samples.  相似文献   

9.
A modified liquid chromatographic method is described for the determination of Gentian Violet (GV) in animal feed. The reliable detection limit is 0.5 ng (reference standards), and 1 ppm GV was reliably determined in feed. The calibration curve was linear between 1 and 40 micrograms/mL. The method, developed in a study by the National Center for Toxicological Research, was modified to use methanol-water (9 + 1) instead of benzene-methanol as the eluting solution in the column cleanup. GV is extracted from feed with methanol-1N HCl (99 + 1), cleaned up on a Sephadex LH-20 column to remove any remaining interferences, separated on a Nova-Pak C18 column fitted with a precolumn filter, and determined at 588 nm. The identity of GV is confirmed by thin-layer chromatography (Rf = 0.47) by comparison with a reference standard. Average recoveries from 3 sets of 5 feed samples containing 2.5, 5.0, and 10.0 ppm GV were 115, 95, and 102%, respectively.  相似文献   

10.
A rapid and simple immunochemical method was developed for the assessment of the creatine kinase (MM) isoenzyme [CK(MM)], a protein marker linked with animal welfare and meat quality. The one-step time-resolved immunofluorometric assay produced quantitative results from serum or whole blood samples in 20 min. The analytical limit of detection (mean + 2s) for the immunoassay was 17 ng/mL (n = 6), and the functional limit of detection for the analysis of porcine whole blood samples was 426 ng/mL (n = 24). The working range of the method was linear up to 50 micro g/mL, and the within-assay precision varied between 2.1 and 10.9%. The analysis of porcine serum samples showed that the results from the immunoassay method and colorimetric CK enzyme activity determination were highly correlated (r(2) = 0.965, n = 17, p < 0.001). The practicability of the assay was demonstrated by the analysis of 300 porcine whole blood samples in a slaughterhouse environment.  相似文献   

11.
High-affinity and selective monoclonal antibodies have been produced against the strobilurin fungicide trifloxystrobin. A battery of functionalized haptens has been synthesized, and conjugate-coated enzyme-linked immunosorbent assays following different procedures have been developed. On the one hand, a two-step conjugate-coated immunoassay was optimized using extended or short incubation times, with limits of detection of 0.10 ng/mL for the extended assay and 0.17 ng/mL for the rapid assay. On the other hand, an immunoassay in the conjugate-coated format was optimized following a procedure consisting of just one incubation step. This one-step assay had a limit of detection of 0.21 ng/mL. All of these assays showed detection limits for trifloxystrobin in the low parts per billion range, well below the common maximum residue limits for this pesticide in foodstuffs (50 microg/kg).  相似文献   

12.
A capillary electrophoresis-based competitive immunoassay (CEIA) with a laser-induced fluorescence (LIF) detector for the determination of carbaryl was developed. The method was based on the competitive reactions between fluorescently labeled carbaryl tracer (Ag*) and free carbaryl (Ag) with a limited amount of anticarbaryl antibody (Ab), and the relative amounts of each were separated and determined by capillary electrophoresis (CE) with an LIF detector. Using CEIA, equilibrium was reached in 30 min, and the analytical results were obtained within a further 8 min. The linear range and the detection limit for carbaryl were 0.16-50 ng/mL and 0.05 ng/mL, respectively. The sensitivity of this CEIA with an LIF detector was almost 14 times greater than that of ELISA, which used the same immuno-reagents. The method was also applied to the analysis of carbaryl in rice with rapid and simple sample pretreatment. The method is thus proposed as a fast and sensitive assay for the detection of carbaryl.  相似文献   

13.
Vegetative insecticidal protein (Vip) is being employed for transgenic expression in selected crops such as cotton, brinjal, and corn. For regulatory compliance, there is a need for a sensitive and reliable detection method, which can distinguish between approved and nonapproved genetically modified (GM) events and quantify GM contents as well. A quantitative immunopolymerase chain reaction (IPCR) method has been developed for the detection and quantification of Vip protein in GM crops. The developed assay displayed a detection limit of 1 ng/mL (1 ppb) and linear quantification range between 10 and 1000 ng/mL of Vip-S protein. The sensitivity of the assay was found to be 10 times higher than an analogous enzyme-linked immunosorbent assay for Vip-S protein. The results suggest that IPCR has the potential to become a standard method to quantify GM proteins.  相似文献   

14.
A competitive direct enzyme-linked immunosorbent assay (ELISA) and high-pressure liquid chromatographic (HPLC) methods were compared in terms of accuracy and precision for the detection and quantification of glyphosate-spiked Nanopure, tap, and river waters. The ELISA had a detection limit of 0.6 ng mL(-)(1) and a linear working range of 1-25 ng mL(-)(1), whereas the HPLC method had a detection limit of 50 ng mL(-)(1) and a linear working range of 100-10000 ng mL(-)(l). No statistically significant differences (95% confidence interval) were found between the ELISA and HPLC analysis of the three water matrixes. The coefficients of variation obtained with the ELISA in tap water were between 10 and 19%, whereas the coefficients of variation for the HPLC analysis were between 7 and 15%. The use of ELISA for the analysis of glyphosate in water is a cost-effective and reliable method capable of meeting water quality guidelines established for Europe and North America.  相似文献   

15.
A competitive enzyme-linked immunosorbent assay (ELISA) was developed for the quantitative detection of the organophosphorus insecticide bromophos-ethyl. Four bromophos-ethyl derivatives (haptens) were synthesized and were coupled to carrier proteins through the pesticide thiophosphate group to use as an immunogen or as a coating antigen. Rabbits were immunized with either one of two haptens coupled to bovine serum albumin for production of polyclonal antibodies, and the sera were screened against one of the haptens coupled to ovalbumin. Using the serum with highest titer, an antigen-coated ELISA was developed, which showed an IC(50) of 3.9 ng/mL with a detection limit of 0.3 ng/mL (20% inhibition). An antibody-coated ELISA using an enzyme tracer was also developed, which showed an IC(50) of 6.5 ng/mL with a detection limit of 1.0 ng/mL (20% inhibition). The antibodies showed negligible cross-reactivity with other organophosphorus pesticides except with the insecticides bromophos-methyl and chlorpyrifos in the antibody-coated assay only. Recoveries of bromophos-ethyl from fortified crop and water samples ranged from 82 to 128% and from 95 to 127%, respectively.  相似文献   

16.
This article presents the generation of monoclonal antibodies (mAbs) with high specificity against 19-nortestosterone (NT) through cell fusion techniques and the development of a mAb-based indirect competitive ELISA (icELISA) method and colloidal gold-based immuno-chromatographic assay to detect NT residues in beef and pork samples. A modified carbodiimide method was employed to synthesize the artificial antigen, and BALB/c mice were used to produce anti-NT mAbs. On the basis of the checkerboard titration, an indirect competitive ELISA standard curve was established. This assay was sensitive and had a linear range from 0.03 to 38 ng/mL in phosphate buffered saline (PBS), with IC(50) and LOD values of 0.52 ng/mL and 0.01 ng/mL, respectively. Of all the competitive analogues, the produced mAb exhibited a high cross-reactivity to 17α-nortestosterone (83.6%), the main metabolite of NT in animal tissues. Except for moderate cross-reactivities with trenbolone (22.6%) and β-boldenone (13.8%), the other interference to the assay was negligible (<0.05%). In contrast, the strip test had a visual detection limit of 1 ng/mL in PBS, 2 μg/kg in beef, and 2 μg/kg in pork, respectively, and the results can be judged within 10 min. The ELISA and GC-MS results showed close correlation in beef (R2=0.9945) and in pork (R2=0.9977). Therefore, the combination of two immunoassays provides a useful screening method for quantitative or qualitative detection of NT residues in animal-origin products.  相似文献   

17.
Competitive direct enzyme-linked immunosorbent assay (ELISA) and the immunochromatographic assay were developed using a monoclonal antibody to detect gentamicin in the animal plasma and milk. No cross-reactivity of the antibody was observed with other aminoglycosides based on competitive direct ELISA, indicating that the antibody is highly specific for gentamicin. On the basis of the standard curves, the detection limits were determined to be 0.9 ng/mL in phosphate-buffered saline (PBS), 1.0 ng/mL in plasma, and 0.5 ng/mL in milk, respectively. Recoveries of gentamicin from spiked plasma and milk at levels of 25-100 ng/mL ranged from 85 to 112%. The concentration of intramuscularly injected gentamicin was successfully monitored in the rabbit plasma through competitive direct ELISA. The detection limits were estimated to be about 6 ng/mL of gentamicin in PBS, plasma, and milk using the colloidal gold-based immunochromatographic assay, which is suitable for the simple screening of gentamicin residues in the veterinary field. Observed positives can be confirmed using a more sensitive laboratory method such as competitive direct ELISA. Therefore, the assays developed in this study could complement each other as well as veterinary field and laboratory findings.  相似文献   

18.
The ethylenebisdithiocarbamate (EBDC) fungicide, nabam, was determined in several crop matrixes using liquid chromatography with postcolumn reaction detection. After separation by micellar liquid chromatography, nabam (EBDC sodium salt) was acid hydrolyzed to ethylenediamine and fluorigenically labeled with o-phthalaldehyde-mercaptoethanol (OPA-MERC). Standard curves were linear from the detection limit of ca 1 ng to 1000 ng. Nabam was recovered in high yield (89 plus or minus 7.7%) over a range of concentrations (0.1 to 20 ppm) from fortified samples of papaya, lettuce, cucumber, spinach, and applesauce using a simple extraction method. Efforts to convert the more popular EBDC fungicides, maneb and mancozeb, to nabam are discussed.  相似文献   

19.
A competitive-indirect enzyme-linked immunosorbent assay (CI-ELISA) was developed to quantify chlorimuron-ethyl in soil. The linear working range of the assay was from 1 to 1000 ng mL(-)(1). The assay had an I(50) value of 54 ng mL(-)(1), with a limit of detection of 2 ng mL(-)(1) and a limit of quantification of 27 ng mL(-)(1). Three soils were extracted using a carbonate buffer (pH 9.0) and the extracts spiked with chlorimuron-ethyl. Because of the effects of coextractants (matrix effects) from soil on the accuracy and precision of the ELISA, immunoaffinity chromatography (IAC) was used to purify chlorimuron-ethyl from soil extracts prior to analysis. The immunoaffinity columns, which had a total binding capacity of 1350 ng of chlorimuron-ethyl mL(-)(1) of immunosorbent, were prepared by binding anti-chlorimuron-ethyl antibodies to protein G Sepharose 4B. Although the matrix effects were largely removed using the affinity column, they could be completely removed by first passing the extract through a column containing epoxy-coupled 1,6-diaminohexane (EAH) Sepharose 4B to remove organic acids prior to IAC. Assay sensitivity was increased 100-fold using IAC to purify and simultaneously concentrate chlorimuron-ethyl from soil extracts. The purification strategy (EAH followed by IAC chromatography) removed matrix effects from all three soils and allowed for the accurate quantitation of chlorimuron-ethyl in soil extracts.  相似文献   

20.
A high-performance liquid chromatography (HPLC) method for the qualitative and quantitative analysis of allantoin in silk and seed of Zea mays has been developed. Allantoin separation in crude extract was achieved using a C 18 column and phosphate buffer solution (pH 3.0) as a mobile phase at ambient temperature at a flow rate of 1.0 mL/min and detected at 210 nm. The results showed that the amount of allantoin in samples was between 14 and 271 mg/100 g of dry plant material. A comprehensive validation of the method including sensitivity, linearity, repeatability, and recovery was conducted. The calibration curve was linear over the range of 0.2-200 microg/mL with a correlation coefficient of r2>0.999. Limit of detection (LOD, S/N=3) and limit of quantification (LOQ) values of the allantoin were 0.05 and 0.2 microg/mL (1.0 and 4.0 ng) respectively. The relative standard deviation (RSD) value of the repeatability was reported within 1.2%. The average recovery of allantoin added to samples was 100.6% with RSD of 1.5%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号