首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
The problem of vibration isolation for the multi supporting machine installed on flexible foundations was studied by power flow and four end parameters methods.The general model of machine,isolator and flexible foundations was founded,and the transmission characteristic of the vibration system is analyzed.The expressions of power flow of the system with wave propagation effect being concerned was also presented.Finally,the effect of foundation flexibility and wave propagation on isolation was analyzed in detail.  相似文献   

2.
Mathematical model of power frequency electric field is established based on Charge Simulation Method(CSM) to analyze power frequency electric field caused by EHV lines with overhead ground wires and its effect, which are entering the megalopolis. Calculative method on the electric field under the transmission lines is analyzed and validated. According to the criterion of environmental evaluation, the distributing characteristic of electric field is summarized, in case of various arrangement manners of lines. At last, some advice and methods of eliminating electric field under the transmission lines entering the megalopolis is proposed with regard to protecting environment.  相似文献   

3.
The utilization of Flexible AC Transimssion System(FACTS)technology has significant impact on power system reliability performance.Series FACTS devices such as Thyristor Controlled Phase Shifting Transformers(TCPSTs) and Thyristor Controlled Series Compensators(TCSCs) can change the natural allocation of the power flow and effectively alleviate transmission congestion.Parallel FACTS devices such as Static Var Compensators(SVCs)can provide reactive power support and maintain voltage stability.So it is important to quantitatively evaluate their benefits to the power system reliability.The traditional models of the composite generation and transmission system reliability evaluation are mainly focused on conventional generation and transmission facilities.This paper researches the power flow model of TCPST and TCSC,and then presents the optimal load shedding model incorporating TCPSTs,TCSCs and SVCs and effectively incorporates them into the reliability evaluation model.The proposed method is tested on the RBTS and the obtained results show that the system reliability can be improved effectually by FACTS devices.  相似文献   

4.
风电并网时既要考虑系统的可靠性又要考虑输电阻塞。目前风电场容量可信度仅从可靠性单一角度提出。为此从输电阻塞角度提出了风电场容量可信度的定义;通过Monte Carlo法建立计及元件故障(发电机、线路和变压器)的风电场容量可信度模型,并提出该模型的二分法求解算法;同时还提出了风电阻塞指标以描述风电场并入电力系统对缓解系统输电阻塞的贡献。通过对修改的IEEE-RTS进行算例分析,验证了方法的正确性和实用性。结果表明:系统阻塞状况的缓解程度与并入风电场的位置有关,风电场容量可信度和风电阻塞指标相结合可以评价风电场并网对系统阻塞状况改善的有效性和经济性。  相似文献   

5.
This paper describes an application of evolutionary programming(EP) to reactive power optimization and voltage control of power systems.Some technical problems which conclude mutation sacle,fitness value and population size have been solved to make EP practical for solving the optimal power flow problems.The computational results with EP have been compared with those obtained from a conventional gradient based optimization method.The comparision shows that EP are better than conventional methods in dealing with the optimization of noncontinuous and nonsmooth funcnons.The EP show the ability to search for the global optimum in reactive optimization that has multiple optima.  相似文献   

6.
In order to achieve optimal bidding strategy of power plants in electricity market, the authors build optimal bidding model by predicting the bidding coefficients of competitors, and the optimal bidding coefficient without considering transmission capacity is achieved. Based on the bidding coefficients, the market clearing model is built, and the expected market clearing price is achieved. According to the expected values, the authors calculate the power flow. When forecasting the transmission congestion, this paper presents an optimal bidding model taking transmission congestion into account. Based on sensitivity analysis, the output regulation of power plants with minimum cost of eliminating congestion is achieved. Simulation results demonstrate that the proposed method can help power plants achieve the optimal profit.  相似文献   

7.
电网发生大面积冰灾情况时,多条输电线路存在覆冰故障隐患,电网稳定运行受到严重威胁,需要提前制定输电线路融冰方案,合理安排融冰顺序。针对此问题,分析输电线路覆冰继续运行给电网带来的停电风险,将与待融冰输电线路相关联的变电站的电气主接线展开,将传统削负荷模型改进后应用于输电网与变电站主接线的组合网络,建立断路器可靠性模型,计算靠后融冰线路因继续运行的电网停电风险;利用计及风速及降雨影响的输电线路覆冰增长预测模型,计算输电线路的覆冰率,根据覆冰率门槛值确定待融冰线路集,基于覆冰严重度模型构建系统全局的覆冰指数指标;综合考虑电网停电风险及系统全局覆冰指数建立输电线路融冰紧迫度指标,动态更新待融冰线路并决策融冰顺序。最后,以IEEE RBTS系统进行算例分析,验证了所提方法的可行性与合理性。  相似文献   

8.
A novel method for power transmission line monitoring and fault diagnosis is proposed based on non linear frequency response analysis. The power line carrier signal has been used for on line monitoring of power transmission line. As the non linear frequency response function describes the system inherent characterization, different frequency response patterns corresponding to different operation states of transmission line can be established. Based on the analysis of transmission line characteristics of fault modes, various fault features can be extracted, thereby achieve online monitoring and fault diagnosis on transmission line. Simulation experiments show the effectiveness of the proposed method.  相似文献   

9.
A new approach of the automatic contingency selection and ranking with the network flow programming (NFP) is presented in this paper. NFP is adaptable to change the network topology as the transmission or generation branches arc in single or multiple outage. Thus the fast calculation of the contingency states by NFP cm provide the urgent information in real time N- 1 security analysis. In the paper, automatic contingency selection and ranking forP- and Q-type subproblem arc solved by an unified network flow model and algorithm. It is based on the existence of weak coupling between real and reactive quantities in power systems. The performance indices to assess the severity of contingencies are defined as the total real and reactive load required to be curtailed. The proposed ACS technique including the model and its algorithm are examined with IEEE 5-, 14-, 30-, 57- and 118- bus test systems on M-340. And the encouraging results are given in the paper.  相似文献   

10.
A fault location algorithm for transmission lines in circle network is presented.The algorithm uses local data. Its location accuracy is independent of power # flow, transient resistance and variation of remote system impedance. Simulation results are satisfactory.  相似文献   

11.
《保鲜与加工》2003,(10):52-55
This paper studies the question for considering optimal load curtailment in bulk power system adequacy evaluation. A minimization model of load curtailment is utilized for the contingency states which may have load curtailment. In order to calculate realistic bus indexes, two practical load curtailment philosophies are incorporated in the minimization model of load curtailment, which is achieved in computer program developed for bulk power system reliability evaluation. The minimization model of load curtailment, correlated algorithms, and flow chart of program are given in this paper. The effectiveness and availability of the model are verified from two case studies.  相似文献   

12.
The paper presents a Monte-carlo method for reliability evaluation of large scale composite generation transmission systems. The method, which possesses coputational rapidity and sufficient accuracy,is based on combining the dispersed sampling techique with the analysis approach and the optimization model of power not supplied. Because the amount of calculation increases only linearly with, the number of elements, it is specially sui- table for large scale systems. The Monte-carlo sampling draws more near the real situation than determinate state enumeration in simulating occurrence of power system outages. Also, the method can be easily generalized to involve multi-states of elements, multi-levels and stochastic distribution of loads. The results of IEEE-RTS, as example, are given and compared with ones obtained by using the other two methods.  相似文献   

13.
An orphogonal frequency division multiplexing(OFDM) based cognitive radio architecture was designed to meet the transmission requirements of a cognitive radio system. After finishing the allocation of subtransmission, and keeping BER within the limit that ensures service quality, an adaptive bit allocation method was proposed to allocate the bit and energy of subtransmission dynamically. The total power for launching needed reached its minimum (or SNR per bit reached its maximum). Compared with the fixed bit allocation method, the proposed method is simpler, decreases the system transmission power, and has better BER performance.  相似文献   

14.
The full name of variable tooth thickness plane worm gear transmission is. Backlash adjustable plane worm gear with variable tooth thickness enveloping worm transmission, which is a new kind of accurate power transmission that is intervenient between traditional motion transmission and power transmission. Tooth surface equations of the variable tooth thickness plane worm gear transmission are deduced based on the theory of engagement. Basing on the result, the authors create a finite analysis model of backlash adjustable variable tooth thickness plane enveloping worm with perfect tooth shape by using I-DEAS software, and then has done finite element analysis of backlash adjustable variable tooth thickness plane enveloping worm transmission. Finally, the author drew a conclusion about distribution of principal stress and load distribution between teeth, which offer some references for strength and performance analysis of worm transmission.  相似文献   

15.
To adapt to the continuous improvement of rural power consumption level in the new rural construction,in particular,with the continuous development of the rural economy,the actual operation of the rural power network has emerged as the high loss of electrical power which leads to a greater cost of the electricity,lower power supply reliability,the supply voltage and frequency do not satisfiy with requirements,etc.Through analysis of a typical rural power network,from the overall planning of the transmission to distribution equipments(such as lines,transformers and reactive-load compensation devices),the author proposes some specific measures such as reducing power loss and improving the voltage quality and reliability methods.Through calculation for lines power loss rate and percent of voltage pass,the results show that the methods proposed by the author are effective.The directions to the development trend of the rural power network is given.  相似文献   

16.
现有IEEE(institute of electrical and electronics engineers)标准,目前只能明确0.5~1.7 MHz有限频段的输电线路无源干扰谐振机理。为拓展输电线路无源干扰谐振的研究频率,引入广义谐振理论,提出了一种基于电磁场能量平衡的干扰谐振频率预测构想。将大尺度空间下输电线路铁塔阵列及天线等效为广义封闭系统,从而基于复坡印廷定理,推导了电磁开放系统广义谐振因子的表达式,求解得到的广义谐振因子零值点为无源干扰谐振频点。该方法由于避开了传统将铁塔等效为半波天线的局限,因此可以实现中波频段无源干扰谐振预测。采用IEEE标准算例进行验证,结果表明:1.7 MHz频率以下,基于广义谐振理论的无源干扰谐振频率预测值和缩比模型实测值最大误差不超过±0.169 MHz。  相似文献   

17.
由于无线电能传输距离的改变或谐振线圈之间发生偏移、负载改变等多方面的影响使系统的输入阻抗发生变化,导致输入阻抗与射频源内阻不匹配,使传输效率大幅下降。在射频源和发射线圈之间加入阻抗匹配网络可以提高无线电能的传输效率。为了提高阻抗匹配的精度和速度,提出了一种改进的粒子群算法。重点将改进算法和传统算法进行仿真实验比较,证明了改进算法在匹配精度和速度方面的优越性。最后将该算法嵌入到自动阻抗匹配系统中,提高了无线电能的传输效率,同时证明了所提算法的有效性。  相似文献   

18.
An A. C. load flow analysis of the reliability evaluation of composite generation and transmission systems is presented on the basis of a fast outage simulation algorithm and an optimal model of active and reactive power adjustment after outage contingencies. The information of the first -level outage events is utilized for simulating higher -level outage events in the fast outage simulation algorithm ; the optimal model is satisfactory in speed and accuracy with the application of concentric relaxation and linear increment constraint on the comprehensive adjustment of active and reactive power. As an example. the IEEE Reliability Test System is tested and the results show that the method is accurate and well-matched in speed with the method studied by R. Bllinton, et al.  相似文献   

19.
In order to improve the existing method of electric network reliability evaluation, the basic concepts, for example, the flow through the failure events, the sent ends and received ends of these failure events, the load curtailment region of the received ends and the degree of the load curtailment, are defined. With these concepts, the connotation of LCSN (Load Curtail Strategy by Near) is enriched and algorithms of the load curtailment region are conducted. The theory foundation for further exploring LCSN is created. The results show that the algorithm can quickly and effectively make reliability assessment of power systems.  相似文献   

20.
The voltage instability of power system often occurs when the active power on one or more weak branches exceeds its transfer capability. A preventive control model for static voltage stability is proposed using the active power transfer capability of weak branches as static voltage stability constraints. A local line based voltage stability index is used to determine the critical contingencies, weak branches and transfer capability of each weak branch. A static security analysis method, which is based on DC power flow equations, is used to establish the non linear active power flow expressions on weak branches following each critical contingency. The active power constraints on weak branches can be obtained from the active power flow expressions and transfer capabilities of weak branches. A quadratic optimal model for preventive control including the proposed active power constraints on weak branches is presented. The simulation results for IEEEE14 bus system and IEEE118 bus system demonstrate the correctness and effectiveness of the proposed preventive control model.  相似文献   