首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
森林防火隔离带技术的变革与优势   总被引:2,自引:0,他引:2  
以消减可燃物的方式预防和阻隔森林火灾是林火管理工作的核心。传统阻隔技术向遮荫型防隔火技术的演变已成为近10余年西方多林国家林火管理工作的重要走向。从林火的特点和蔓延基本规律出发, 遮荫型防火隔离带技术通过局部消减可燃物载量和规则化可燃物分布, 显著降低其可能形成的林火强度, 使大多数火灾自行熄灭。该项技术的实施不受区域和气候条件限制; 与传统全光式防火隔离带和生物防火林带相比, 不但工作量较小, 对林分植被和生态环境的干扰也较小。该项技术实现了偶发性林火的防控、森林健康及生态维护的有机结合, 以此替代传统防火隔离带技术效益显著。针对遮荫型防隔火技术的进一步研究工作应包括不同稀化程度林带潜在火行为和其防隔火效能的量化评估、林地局部可燃物稀化的高效作业机具以及伴随该项技术实施产生的大量生物质副产品的有效利用问题。  相似文献   

2.
Canopy fuel characteristics that influence the initiation and spread of crown fires were measured in representative Aleppo pine (Pinus halepensis Mill.) stands in Greece. Vertical distribution profiles of canopy fuel load, canopy base height and canopy bulk density are presented. Aleppo pine canopy fuels are characterized by low canopy base height (3.0–6.5 m), while available canopy fuel load (0.96–1.80 kg/m2) and canopy bulk density (0.09–0.22 kg/m3) values are similar to other conifers worldwide. Crown fire behavior (probability of crown fire initiation, crown fire type, rate of spread, fireline intensity and flame length) in Aleppo pine stands with various understory fuel types was simulated with the most updated crown fire models. The probability of crown fire initiation was high even under moderate burning conditions, mainly due to the low canopy base height and the heavy surface fuel load. Passive crown fires resulted mostly in uneven aged stands, while even aged stands gave high intensity active crown fires. Assessment of canopy fuel characteristics and potential crown fire behavior can be useful in fuel management and fire suppression planning.  相似文献   

3.
北京西山防火林带空间布局与规划   总被引:1,自引:0,他引:1       下载免费PDF全文
以北京市西山试验林场分场魏家村林场为研究区域,系统地研究了火发生历史、可燃物分布、主风向、坡度、山脊、防火公路、居民区分布等,确定了网络适宜的最小控制面积,通过面向对象的分类方法对林中空地和防火公路进行分类,筛选适宜建山脊防火林带的坡度和山脊线,进而确定防火林带的空间格局。共规划三类防火林带:山脊防火林带、防火公路防火林带和林缘防火林带,整个防火林带网络将整个区域分割成不等大小的独立单元,平均面积为41.24 hm2,防火公路总长36 816 m,防火网络总面积占研究区域面积的7.35%。  相似文献   

4.
森林火灾中的树冠火研究   总被引:5,自引:1,他引:4  
森林火灾按其燃烧物和燃烧部位的不同, 通常可分为地表火、树冠火和地下火3种。树冠火是指在林冠层燃烧和蔓延的火, 通常与地表火同时发生。树冠火发生数量不多, 但其燃烧温度高、火强度大、蔓延速度快, 对森林的破坏性极大。从树冠火的发生机制、蔓延模型、扑救方法、预防和减弱树冠火发生及蔓延危险性的措施几方面对当前国内外树冠火的研究进展进行了综述, 并对今后的研究方向进行了展望。  相似文献   

5.
Crown fire occurrence and subsequent crown fire behaviour are strongly dependent on canopy fuel characteristics, especially canopy fuel load (CFL), canopy bulk density (CBD) and canopy base height (CBH). Therefore, quantification of such variables is required for the appropriate selection of silvicultural treatments aimed at reducing susceptibility to crown fire. Data from the IV Spanish National Forest Inventory and individual tree biomass dry weight equations were used to estimate the canopy fuel characteristics of four representative types of pine stands in north-western Spain. Probability of crown fire initiation and crown fire rate of spread were simulated by using the mean surface fuel load observed for each type of pine in this area and assuming different burning conditions. The results indicate that a 22.13 % of the sample plots analysed showed a rather high potential for active crown fire spread under moderate burning conditions, and this value increases to 69.27 % under extreme burning conditions. Equations relating the canopy fuel characteristics to common stand variables (stand density, basal area and dominant height) were fitted simultaneously for each pine, and weighting factors for heteroscedasticity were included. The models explained more than 93.90, 74.70 and 69.42 % of the observed variability in CFL, CBD and CBH, respectively. Basal area was the most important variable for estimating CFL and CBD while dominant height explained most of the observed variability in CBH. The use of the fitted equations together with existing dynamic growth models and fire management decision support systems will enable assessment of the crown fire potential associated with different silvicultural alternatives used in these types of pine stands.  相似文献   

6.
通过对2001-2007年黑龙江省夏季森林火灾调查研究发现,该地区夏季林火种类有地表火、地下火、树冠火3种,这3种蔓延方式之间相互演变,多数为地表火与地下火同时存在。夏季林火蔓延速度普遍较慢,地表火蔓延速度大多在0.05m/s以下;浅层地下火在有林地的燃烧速度为2-4m/h、草甸为1-3m/h,深层地下火在有林地的燃烧速度为0.2m/h以下、草甸为0.05m/h以下;树冠火蔓延速度一般为180-600m/h。  相似文献   

7.
Nomographs that calculate the threshold values of surface fire parameters which lead to crown fire initiation were created by linking two separate fire behavior models: Van Wagner’s crown fire ignition criteria and Byram’s surface fire model. The nomographs were also based on the existing surface (fuel load, fuel heat content) and canopy (foliar moisture content, live crown base height) fuel models of Aleppo (Pinus halepensis Mill.) pine forests of Mediterranean Greece. The most important fire parameters for crown fire initiation that are calculated by the nomographs are the critical flame length and the forward spread rate of the surface fire. These parameters are readily observable in the field during fires. The nomographs provide a judicious way to assess whether a crown fire is likely to occur in a conifer forest stand. Although the fire behavior models used had limited testing and are based on certain assumptions, yet they are widely applied in forestry practice worldwide, as a basis for justified fire prevention and suppression planning.  相似文献   

8.
The early post-fire development of mycobiota following a crown fire in mountain pine plantations and a surface fire in Scots pine plantations, and in the corresponding unburnt stands in the coastal sand dunes of the Curonian Spit in western Lithuania was investigated. Species numbers in unburnt Pinus mugo and Pinus sylvestris stands showed annual fluctuation, but in the burnt sites, the numbers of fungi increased yearly, especially in the crown fire plots. Both burnt stand types—P. mugo and P. sylvestris—showed strongly significant (two-way ANOSIM; R = 1, p < 0.05) differences in species composition; the differences between unburnt sites were clearly expressed but less significant (R = 0.86, p < 0.05). Fungal species composition of burnt P. mugo and P. sylvestris sites was qualitatively different from that of corresponding unburnt sites (two-way ANOSIM; R ≥ 0.75, p < 0.05). The chronosequence of mycobiota in surface fire burns was less clearly defined than in crown fire sites, reflecting the greater patchiness of impacts of the surface fire. Although both fire types were detrimental or at least damaging to all functional groups of fungi (saprobic on soil and forest litter, wood-inhabiting, biotrophic, and mycorrhizal and lichenized fungi), their recovery and appearance (fructification) patterns varied between the groups and among the burn types. The end of the early post-fire fungal succession (cessation of sporocarp production of pyrophilous fungi) was recorded 3 years after the fire for both crown and surface fire types, which is earlier than reported by other authors. Rare or threatened fungal species that are dependent on fire regime were not recorded during the study.  相似文献   

9.
There is a lack of knowledge to identify and classify forest structures according to the risk of crown fires, especially in Mediterranean regions. In this study, for the first time, we use real information, obtained after a wildfire that burnt under extreme meteorological conditions, to classify forest structures of Pinus halepensis into fuel types as a function of crown fire potential. We identified fourteen forest structures which characterize many forest types in Western Mediterranean areas depending on canopy closure, number of tree layers, percent of each tree layer and overall tree density. By using the pattern of fire types that burnt the most numerous forest structures, we have identified four fire hazard groups of forest structures which are considered different fuel types. The first two had the lowest risk of active crown fires and they differed in the proportion of surface fires and passive crown fires. The third fuel type was the threshold between structures with low and high extreme fire behavior; while the fourth had a high risk of active crown fires. Firefighters and forest managers who are demanding this kind of schema, will test and upgrade this classification of fuel types in function of crown fire potential during future wildfires.  相似文献   

10.
To determine the suitability of Schima superba Gardn. et Champ as a fuelbreak, we compared and analyzed the flammability characteristics of tree litter from three trees commonly grown in south China, i.e., Pinus massoniana Lamb., Cunninghamia lanceolata (Lamb.) Hook., and S. superba, using a cone calorimeter at five different water content levels. Water content levels of 10%, 15%, 20%, 25% and 30% for the litter were manually produced with a new technique of adding water to dry litter. The cone calorimeter utilized a radiant heat intensity for leaf litter of 20 kW/m2 (510°C) and for twig litter of 30 kW/m2 (608°C). Results show that fixing the water content level by adding water with a pipette was an acceptable technique. For S. superba, compared to P. massoniana and C. lanceolata, 1) the heat release rate (HRR) was slower and lower; 2) the total heat released (THR) from the material was lower and started later in the burning process; and 3) except for the 10% water content, pkHRR/TTI was less. These results show that overall, S. superba was the best of the three species to be used as a fuelbreak in south China. __________ Translated from Scientia Silvae Sinicae, 2008, 44(5): 96–101 [译自: 林 业科学]  相似文献   

11.
防火林带营造木荷火力楠混交林生长效果分析   总被引:1,自引:0,他引:1  
对马尾松低产林改造,营造防火林带木荷火力楠生长效果进行了调查,发现林木生长良好。结果显示:经过14a的培育,其林木生长不同,木荷火力楠混交林的林分生长量,比木荷、火力楠纯林的林分生长量更具优势,平均树高、胸径、树冠、枝下高、郁闭度、单株材积、蓄积量,分别比木荷、火力楠纯林林分平均树高大13.54%、8.55%,胸径粗18.39%、14.21%,树冠大8.24%、22.26%,枝下高8.75%、17.67%,郁闭度大2.13%、3.23%,单株材积大45.43%、41.18%,蓄积量大54.95%、37.54%。土壤肥力N、P、K分别提高0.9%、1.92%、1.79%,1.80%、6.00%、3.64%。木荷火力楠混交林能涵养水源、保持水土,有效控制林火蔓延,可减少森林火灾和灾后损失。  相似文献   

12.
Bark beetle-caused tree mortality in conifer forests affects the quantity and quality of forest fuels and has long been assumed to increase fire hazard and potential fire behavior. In reality, bark beetles, and their effects on fuel accumulation, and subsequent fire hazard, are poorly understood. We extensively sampled fuels in three bark beetle-affected Intermountain conifer forests and compared these data to existing research on bark beetle/fuels/fire interactions within the context of the disturbance regime. Data were collected in endemic, epidemic and post-epidemic stands of Douglas-fir, lodgepole pine and Engelmann spruce. From these data, we evaluated the influence of bark beetle-caused tree mortality on various fuels characteristics over the course of a bark beetle rotation. The data showed that changes in fuels over time create periods where the potential for high intensity and/or severe fires increases or decreases. The net result of bark beetle epidemics was a substantial change in species composition and a highly altered fuels complex. Early in epidemics there is a net increase in the amount of fine surface fuels when compared to endemic stands. In post-epidemic stands large, dead, woody fuels, and live surface fuels dominate. We then discuss potential fire behavior in bark beetle-affected conifer fuels based on actual and simulated fuels data. Results indicated that for surface fires both rates of fire spread and fireline intensities were higher in the current epidemic stands than in the endemic stands. Rates of spread and fireline intensities were higher in epidemic stands due, however, to decreased vegetative sheltering and its effect on mid-flame wind speed, rather than changes in fuels. Passive crown fires were more likely in post-epidemic stands, but active crown fires were less likely due to decreased aerial fuel continuity. We also discuss the ecological effects of extreme fire behavior. Information is presented on managing forests to reduce the impact of bark beetle outbreaks and the interplay between management, bark beetle populations, fuels and fire hazard and behavior.  相似文献   

13.
Several wildfire prevention programs in southern Europe are currently using livestock grazing for the maintenance of fuelbreaks. This silvopastoral management is valued for being sustainable and effective in reducing fuel loads, but few studies have analyzed other impacts linked to fuelbreak grazing. This paper reports on an experiment performed within the wildfire prevention program in Andalusia (southern Spain) with the aim of clarifying and quantifying the effect of fuelbreak grazing on herbage biomass, ground cover, herbage species composition, and growth of holm oak saplings. The study site, located in a semiarid Mediterranean environment, was grazed by a shepherded sheep flock from February to June in three consecutive years at a similar stocking rate. Livestock consumed between 33 and 68 % of herbage production in the different years, and the greatest fuel reduction (remaining dry matter of 200?kg?ha?1) was registered in Year 2, when rainfall and herbage production was lowest. Ground cover was significantly affected by grazing: on average, the percentage of bare soil increased three-fold, while herbage cover was reduced by a quarter. The botanical composition of herbage varied remarkably between years, but very little between Grazed and Non-Grazed areas within each year. Non-browsed holm oak saplings became progressively larger than browsed ones, differences only reaching clear statistical significance at the end of the three experimental years. At this time, the volume of browsed saplings was 47–56 % smaller than that of non-browsed holm oaks, even though the former had also grown significantly in the course of the experiment.  相似文献   

14.
This paper describes the development of a logistic model to predict the probability of surface fire spread in Brazilian rainforest fuels from outdoor experimental measurements. Surface fires spread over litter composed mostly of dead leaves and twigs. There were 72 individual outdoor experiments in eighteen sites. The fire propagated in 49% of the experiments. In each experiment, the litter height, litter temperature, unburned litter mass, wet and dry litter mass, soil temperature, wet and dry soil mass, ambient wind velocity, ambient air temperature, ambient air relative humidity and duration of fire spread were measured. Using these data, the rate of fire spread, litter bulk density, litter and soil moisture content, litter load and litter residue fraction were determined. For the sake of analysis, experimental results were classified into two groups: one for which the fire propagated and the other one for which the fire self-extinguished. Analyses of a logistic regression model showed that the relevant parameters for fire propagation are litter height and litter moisture content. Concerning the probability of successful fire propagation, the model showed a true positive rate of 71% and a true negative rate of 84%. The outdoor experiments also served to gather data to improve the understanding of surface fires and to provide input data for future computer simulations.  相似文献   

15.
Canopy fuel characteristics that influence the initiation and spread of crown fires were measured in forty representative Aleppo pine (Pinus halepensis Mill.) stands in Greece. Aleppo pine canopy fuels are characterized by low canopy base height (CBH) (2.0–6.5 m), while available canopy fuel load (CFL) (0.63–1.82 kg/m2) and canopy bulk density (CBD) (0.07–0.22 kg/m3) values are similar to those of other conifers worldwide. Regression equations for the estimation of canopy fuels were developed based on common stand parameters. Stand basal area was the best-fitted predictor for the estimation of CFL and CBD at stand level, explaining 77 and 74 % of the observed variation, respectively. Regression analysis failed to provide any significant estimates for the CBH. Prediction of canopy fuel characteristics based on stand basal area can be useful in fuel management and fire prevention planning since it and can be easily incorporated into existing forest inventory systems and can be used for the Kyoto protocol requirements of carbon changes in Aleppo pine forests located in Greek sites.  相似文献   

16.
生物防火林带技术的科学基础和发展前景   总被引:4,自引:0,他引:4       下载免费PDF全文
生物防火林带技术是将特定常绿阔叶树种呈带状密植到易燃的植物群落中,用以预防和阻隔地表火及树冠火蔓延。研究表明,生物防火林带的防隔火功能不只是来自于植物叶片间可燃性的差异,更多源于常绿阔叶树的树冠结构以及相对密植构成的独特林分。通过抑制带内地表可燃物的生长,实现对地表火的阻隔;在遭受树冠火袭击时,以其树冠较弱的可燃性和分层特性消减火势(强度),降低火蔓延过程中热量输运的效率,使火蔓延自动终止。与传统的防火隔离带(生土带)相比,该项技术在阻挡火焰辐射、飞火以及保持水土和生态维护等方面拥有绝对优势。由于缺乏对其抵抗树冠火规模的量化认识,也没有建立起量化的技术性能指标以及细化的实施规范,生物防火林带技术仍处于经验型阶段。对该项技术的进一步发展与完善,不仅可以确保其在森林防火分隔实践中的应用效果,还可以在森林和城镇结合部等火灾多发地域发挥更大的作用。  相似文献   

17.
Spatial heterogeneity of fuel moisture content determines the spread rate and direction of a forest fire.Research on the spatial heterogeneity of the moisture content of dead fuel of Larix gmelinii Rupr.showed that:(1) fuel moisture content in litter layer semi-humus layer humus layer,and the coefficient of variation decreased with sampling depth;(2) the sill value of the semi-humus layer was highest,the humus layer moderate,the litter layer the smallest,overall,the spatial heterogeneity of the semi-humus layer was the highest.The humus layer in the slant direction and three layers in a vertical direction showed strong spatial correlation with the lowest nugget coefficient of 0.0968;(3)the fuel moisture content of the humus layer showed strong spatial anisotropy;and,(4) estimating the total moisture content of the sampling site by stimulated sampling reasonable control of the sampling interval,and increasing the sampling intensity can reduce the error.When the sampling intensity is increased to more than 16 and the sampling interval 3 m,the standard error is 15%.The spatial heterogeneity of fuel moisture content is best revealed by increasing sampling density,sampling in different fire seasons,and in different slope directions and positions.The results can provide a scientific basis for forest fire prediction and prevention.  相似文献   

18.
以云杉不同光照强度的树冠枝条针叶和老针叶为试样,研究灰分中矿质元素的种类与分布特点和对亚甲基蓝的吸附,结果表明,阳面针叶中的矿质元素含量高于阴面,且K和Ca元素的含量高于Mg和Fe元素;老叶的矿质元素含量高于新叶,同样K和Ca元素的含量高于Mg和Fe元素。灰分在紫外可见光波长为650nm处时,亚甲基蓝的吸光度值最大;吸附平衡时间为70 min;0.4 g灰分为最佳用量;90℃时达到吸附平衡;在酸性范围内,随pH值增大,吸附力下降,碱性条件下则相反。  相似文献   

19.
针叶林阔叶化改造的森林生态防火效果初报   总被引:2,自引:0,他引:2  
结合森林生态防火,引入木荷、苦槠、青冈、石栎、枫香等耐火目的树种对马尾松和杉木林退化系统进行阀叶化改造.在千岛湖区进行杉木间伐补植木荷、枫香,杉木萌芽林补植苦槠、青冈,马尾松林下补植枫香、青冈或苦槠、石栎四种不同阔叶化改造试验,3年后的调查测定结果表明:通过改造,优化了林分结构,马尾松阔叶化改造促进生态恢复的速度更为迅速.改造林分内枯落物比针叶林少,而枯落物含水率高;土壤含水率则因立地条件而异.阔叶化改造后具有明显提高生物多样性和防火效果及一定的涵养水源、保持水土作用.通过针叶林阔叶化改造,调整树种的组成结构、可燃物的空间分布,改善林地环境,以森林的片状控制代替林带控制,全方位有效控制森林火灾,在当前可持续发展和生态环境改善日益重视的社会背景与发展趋势下,具有推广应用前景.  相似文献   

20.

Context

Density management diagrams (DMDs) are useful for designing, displaying and evaluating alternative density management regimes for a given stand-level management objective. The inclusion of variables related to crown fire potential within DMDs has not previously been considered.

Aims

The aim of this study was to include isolines of variables related to crown fire initiation and spread in DMDs to enable identification of stand structures associated with different types of wildfire.

Methods

Biometric and fuel data from maritime pine (Pinus pinaster Ait.) stands in NW Spain were used to construct DMDs. Different surface and crown fire behaviour models were used together to estimate crown fire potential.

Results

The crown fire potential varied greatly throughout development of the maritime pine stands. Low stands were more prone to crowning. The type of crown fire was mainly determined by stand density.

Conclusion

The DMDs developed can be used to identify relationships between stand structure and crown fire potential, thus enabling the design of thinning schedules aimed at reducing the likelihood of crowning.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号