OBJECTIVE: To evaluate in vitro holding power and associated microstructural and thermal damage from placement of positive-profile transfixation pins in the diaphysis and metaphysis of the equine third metacarpal bone. SAMPLE POPULATION: Third metacarpal bones from 30 pairs of adult equine cadavers. PROCEDURE: Centrally threaded positive-profile transfixation pins were placed in the diaphysis of 1 metacarpal bone and the metaphysis of the opposite metacarpal bone of 15 pairs of bones. Tensile force at failure for axial extraction was measured with a materials testing system. An additional 15 pairs of metacarpal bones were tested similarly following cyclic loading. Microstructural damage was evaluated via scanning electron microscopy in another 6 pairs of metacarpal bones, 2 pairs in each of the following 3 groups: metacarpal bones with tapped holes and without transfixation pin placement, metacarpal bones following transfixation pin placement, and metacarpal bones following transfixation pin placement and cyclic loading. Temperature of the hardware was measured with a surface thermocouple in 12 additional metacarpal bones warmed to 38 C. RESULTS: The diaphysis provided significantly greater resistance to axial extraction than the metaphysis. There were no significant temperature differences between diaphyseal and metaphyseal placement. Microstructural damage was limited to occasional microfractures seen only in cortical bone of diaphyseal and metaphyseal locations. Microfractures originated during drilling and tapping but did not worsen following transfixation pin placement or cyclic loading. CONCLUSIONS AND CLINICAL RELEVANCE: Centrally threaded, positive-profile transfixation pins have greater resistance to axial extraction in the diaphysis than in the metaphysis of equine third metacarpal bone in vitro. This information may be used to create more stable external skeletal fixation in horses with fractures.  相似文献   

2.
OBJECTIVE: To compare the in vitro holding power and associated microstructural damage of 2 large-animal centrally threaded positive-profile transfixation pins in the diaphysis of the equine third metacarpal bone. SAMPLE POPULATION: 25 pairs of adult equine cadaver metacarpal bones. PROCEDURE: Centrally threaded positive-profile transfixation pins of 2 different designs (ie, self-drilling, self-tapping [SDST] vs nonself-drilling, nonself-tapping [NDNT] transfixation pins) were inserted into the middiaphysis of adult equine metacarpal bones. Temperature of the hardware was measured during each step of insertion with a surface thermocouple. Bone and cortical width, transfixation pin placement, and cortical damage were assessed radiographically. Resistance to axial extraction before and after cyclic loading was measured using a material testing system. Microstructural damage caused by transfixation pin insertion was evaluated by scanning electron microscopy. RESULTS: The temperature following pin insertion was significantly higher for SDST transfixation pins. Periosteal surface cortical fractures were found in 50% of the bones with SDST transfixation pins and in none with NDNT transfixation pins. The NDNT transfixation pins were significantly more resistant to axial extraction than SDST transfixation pins. Grossly and microscopically, NDNT transfixation pins created less damage to the bone and a more consistent thread pattern. CONCLUSIONS AND CLINICAL RELEVANCE: In vitro analysis revealed that insertion of NDNT transfixation pins cause less macroscopic and microscopic damage to the bone than SDST transfixation pins. The NDNT transfixation pins have a greater pull out strength, reflecting better initial bone transfixation pin stability.  相似文献   

3.
OBJECTIVE: To evaluate clinical findings, complications, and outcome of horses and foals with third metacarpal, third metatarsal, or phalangeal fractures that were treated with transfixation casting. DESIGN: Retrospective case series. Animals-29 adult horses and 8 foals with fractures of the third metacarpal or metatarsal bone or the proximal or middle phalanx. PROCEDURES: Medical records were reviewed, and follow-up information was obtained. Data were analyzed by use of logistic regression models for survival, fracture healing, return to intended use, pin loosening, pin hole lysis, and complications associated with pins. RESULTS: In 27 of 35 (77%) horses, the fracture healed and the horse survived, including 10 of 15 third metacarpal or metatarsal bone fractures, 11 of 12 proximal phalanx fractures, and 6 of 8 middle phalanx fractures. Four adult horses sustained a fracture through a pin hole. One horse sustained a pathologic unicortical fracture secondary to a pin hole infec-tion. Increasing body weight, fracture involving 2 joints, nondiaphyseal fracture location, and increasing duration until radiographic union were associated with horses not returning to their intended use. After adjusting for body weight, pin loosening was associated with di-aphyseal pin location, pin hole lysis was associated with number of days with a transfixation cast, and pin complications were associated with hand insertion of pins. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that transfixation casting can be successful in managing fractures distal to the carpus or tarsus in horses. This technique is most suitable for comminuted fractures of the proximal phalanx but can be used for third metacarpal, third metatarsal, or middle phalanx fractures, with or without internal fixation.  相似文献   

4.
OBJECTIVE: To determine the effect of 2 hydroxyapatite pin coatings on heat generated at the bone-pin interface and torque required for insertion of transfixation pins into cadaveric equine third metacarpal bone. SAMPLE POPULATION: Third metacarpal bone pairs from 27 cadavers of adult horses. PROCEDURES: Peak temperature of the bone at the cis-cortex and the hardware and pin at the trans-cortex was measured during insertion of a plasma-sprayed hydroxyapatite (PSHA)-coated, biomimetic hydroxyapatite (BMHA)-coated, or uncoated large animal transfixation pin. End-insertional torque was measured for each pin. The bone-pin interface was examined grossly and histologically for damage to the bone and coating. RESULTS: The BMHA-coated transfixation pins had similar insertion characteristics to uncoated pins. The PSHA-coated pins had greater mean peak bone temperature at the cis-cortex and greater peak temperature at the trans-cortex (70.9 +/- 6.4(o)C) than the uncoated pins (38.7 +/- 8.4(o)C). The PSHA-coated pins required more insertional torque (10,380 +/- 5,387.8 Nmm) than the BMHA-coated pins (5,123.3 +/- 2,296.9 Nmm). Four of the PSHA-coated pins became immovable after full insertion, and 1 gross fracture occurred during insertion of this type of pin. CONCLUSIONS AND CLINICAL RELEVANCE: The PSHA coating was not feasible for use without modification of presently available pin hardware. The BMHA-coated pins performed similarly to uncoated pins. Further testing is required in an in vivo model to determine the extent of osteointegration associated with the BMHA-coated pins in equine bone.  相似文献   

5.
In vitro local fatigue testing of the third metacarpal bone from Thoroughbred and Standardbred racehorses was performed, using fully reversed cyclic bending. Strain number of cycle data were accumulated and indicated that significant difference did not exist between the 2 breeds. It was concluded that the marked difference in the incidence of fatigue failure in the third metacarpal bone (bucked shins, dorsal metacarpal disease) seen in Thoroughbreds and Standardbreds was not related to any differences between the 2 breeds in mechanical properties of the bone.  相似文献   

6.
Objectives: To compare the number of cycles to failure of 4.5 mm broad dynamic compression plates (DCP), 4.5 mm broad limited‐contact dynamic compression plates (4.5‐LC‐DCP), and 5.5 mm broad limited‐contact dynamic compression plates (5.5‐LC‐DCP) having a rough (denoted by a prefix R‐) versus a standard smooth contact surface for the fixation of osteotomized equine 3rd metacarpal (MC3) bones. Study Design: Experimental. Animal Population: Fifteen pairs of adult equine cadaveric MC3 bones. Methods: Fifteen pairs of equine MC3 were divided into 3 test groups (5 pairs each) for comparison of (1) R‐DCP fixation with DCP fixation, (2) R‐4.5‐LC‐DCP fixation with 4.5‐LC‐DCP fixation, and (3) R‐5.5‐LC‐DCP fixation with 5.5‐LC‐DCP fixation to repair osteotomized equine MC3 bones under palmarodorsal 4‐point bending cyclic fatigue testing. For each group an 8‐hole plate with rough contact surface was applied to the dorsal surface of one randomly selected bone from each pair and a corresponding 8‐hole plate with smooth contact surface was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard ASIF techniques. All MC3 bones had mid‐diaphyseal osteotomies. Mean number of cycles to failure for each method were compared using a paired t‐test within each group. Significance was set at P<.05. Results: Mean cycles to failure ± standard deviation was significantly greater for the R‐DCP fixation (230,025 ± 23,129) compared with the DCP fixation (103,451 ± 14,556), for the R‐4.5‐LC‐DCP fixation (99,237 ± 14,390) compared with the 4.5‐LC‐DCP fixation (46,464 ± 6325) and for the R‐5.5‐LC‐DCP fixation (65,113 ± 7796) compared with the 5.5‐LC‐DCP fixation (34,224 ± 3835). Conclusion: For the fixation of osteotomized MC3 bones, the constructs with plates having rough contact surface were superior to the corresponding constructs with plates having standard smooth contact surfaces in resisting cyclic fatigue under palmarodorsal 4‐point bending.  相似文献   

7.
Seemingly, propagation of a dorsal cortical fracture in the third metacarpal bone developed after continued race performance in 2 horses. Historically, both horses had intermittent lameness that had responded to nonsteroidal anti-inflammatory drugs and brief rest periods. However, lameness in both horses had increased in severity. Radiography revealed a dorsal cortical fracture of the third metacarpal bone, with propagation of the fracture plane proximally. Fractures were incomplete and healed with stall rest in both horses.  相似文献   

8.
OBJECTIVE--To compare the mechanical properties of 2 interlocking-nail systems for fixation of ostectomized equine third metacarpi (MC3): (1) a standard interlocking nail with 2 parallel screws proximal and distal to a 1-cm ostectomy; and (2) a modified interlocking nail with 2 screws proximal and distal to a 1-cm ostectomy with the screws offset by 30 degrees. ANIMAL OR SAMPLE POPULATION--Twelve pairs of adult equine forelimbs intact from the midradius distally. METHODS--Twelve pairs of equine MC3 were divided into 2 test groups (6 pairs each): torsion and caudocranial 4-point bending. Standard interlocking nails (6-hole, 13-mm diameter, 230-mm length) were placed in 1 randomly selected bone from each pair. Modified interlocking nails (6-hole, 13-mm, 230-mm length, screw holes offset by 30 degrees) were placed in the contralateral bone from each pair. All bones had 1-cm mid-diaphyseal ostectomies. Six construct pairs were tested in caudocranial 4-point bending to determine stiffness and failure properties. The remaining 6 construct pairs were tested in torsion to determine torsional stiffness and yield load. Mean values for each fixation method were compared using a paired t test within each group. Significance was set at P <.05. RESULTS--Mean (+/-SEM) values for the MC3-standard interlocking-nail composite and the MC3-modified interlocking-nail composite, respectively, in 4-point bending were: composite rigidity, 3,119 +/- 334.5 Nm/rad (newton. meter/radian) and 3,185 +/- 401.2 Nm/rad; yield bending moment, 205.0 +/- 18.46 Nm and 186.7 +/- 6.17 Nm; and failure bending moment, 366.4 +/- 21.82 Nm and 378.1 +/- 20.41 Nm. There were no significant differences in the biomechanical values for bending between the 2 fixation methods. In torsion, mean (+/-SEM) values for the MC3-standard interlocking-nail composite and the MC3-modified interlocking-nail composite were: composite rigidity, 135.5 +/- 7.128 Nm/rad and 112.5 +/- 7.432 Nm/rad; gap stiffness, 207.6 +/- 10.57 Nm/rad and 181.7 +/- 12.89 Nm/rad; and yield load, 123.3 +/- 2.563 Nm and 107.5 +/- 8.353 Nm, respectively. Composite rigidity and gap stiffness for standard interlocking-nail fixations were significantly higher than the modified interlocking-nail fixation technique in torsion. Yield load had a tendency to be higher for the standard interlocking-nail fixation (P =.15). CONCLUSIONS--No significant differences in biomechanical properties were identified between a standard interlocking nail and one with the screw holes offset by 30 degrees in caudocranial 4-point bending. The standard interlocking nail was superior to the modified interlocking nail in torsional gap stiffness and composite rigidity. The torsional yield load also tended to be higher for the standard interlocking nail. CLINICAL RELEVANCE--The standard interlocking nail with parallel screw holes is superior to a modified interlocking nail with the screw holes offset by 30 degrees in ostectomized equine MC3 bones in vitro when tested in torsion.  相似文献   

9.
Five horses with long incomplete longitudinal fractures of the third metacarpal bone and three horses with similar fractures of the third metatarsal bone were examined. In three of the metacarpal fractures a long incomplete fissure extended proximomedially, in association with the more common lateral condylar fracture of the third metacarpal bone, and in the other two cases the fracture originated from the medial aspect of the distal articular surface. In the three horses with fractures of the third metatarsal bone the fractures had a consistent spiral configuration.  相似文献   

10.
Objective— To compare monotonic biomechanical properties and fatigue life of a broad locking compression plate (LCP) fixation with a broad limited contact dynamic compression plate (LC‐DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. Study Design— In vitro biomechanical testing of paired cadaveric equine MC3 with a mid‐diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. Animal Population— Cadaveric adult equine MC3 bones (n=12 pairs). Methods— MC3 were divided into 3 groups (4 pairs each) for: (1) 4‐point bending single cycle to failure testing; (2) 4‐point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. The 8‐hole, 4.5 mm LCP was applied to the dorsal surface of 1 randomly selected bone from each pair. One 8‐hole, 4.5 mm LC‐DCP) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard ASIF techniques. All MC3 bones had mid‐diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t‐test within each group. Significance was set at P<.05. Results— Mean yield load, yield bending moment, composite rigidity, failure load and failure bending moment, under 4‐point bending, single cycle to failure, of the LCP fixation were significantly greater than those of the LC‐DCP fixation. Mean cycles to failure for 4‐point bending was significantly greater for the LCP fixation compared with LC‐DCP fixation. Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad LCP fixation compared with the LC‐DCP fixation. Conclusion— The 4.5 mm LCP was superior to the 4.5 mm LC‐DCP in resisting the static overload forces (palmarodorsal 4‐point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4‐point bending. Clinical Relevance— The results of this in vitro study may provide information to aid in the selection of a biological plate for the repair of equine long bone fractures.  相似文献   

11.
Nuclear scintigraphy was used to evaluate healing of third metacarpal bone (MC III) fractures in 2 horses (horses 1 and 2) and a third metatarsal bone fracture in 1 horse (horse 3) after stabilization of each fracture with 2 broad dynamic compression plates. In horse 1, the fracture had uniform uptake of 99mTc methylene diphosphonate on days 1, 15, and 30 after surgery. The fracture healed, and the horse was discharged from the clinic on day 52. In horse 2, a 6-cm photopenic region (ie, area of low radioactivity) was seen over the diaphysis of MC III on day 3. The region persisted and became more distinct by day 32. The diaphysis of MC III sequestered, and horse 2 was euthanatized on day 44. In horse 3, vascularity was seen bridging the fracture on day 5, with a 3-cm photopenic region over the dorsal diaphysis of the third metatarsal bone. By days 18 and 32, uptake of 99mTc methylene diphosphonate in the region had increased, indicating vascularization of the site. the fracture healed, and horse 3 was discharged from the clinic on day 47. Our findings indicated that serial nuclear scintigraphy can be used to evaluate fracture vascularization after surgery in horses.  相似文献   

12.
13.
The stiffness, load to failure, and bending moments of adult intact equine humeri and humeri repaired with 3 fixation techniques were determined in vitro. Bones were tested in axial compression (30 pairs), mediolateral 3-point bending (15 pairs), and caudocranial 3-point bending (15 pairs). An oblique osteotomy of 1 humerus of each pair was performed to simulate the long spiral oblique fractures that occur clinically in horses. Bones were repaired in 3 ways: group 1--nylon band cerclage fixation (20 bones); group 2--multiple intramedullary pinning (20 bones); and group 3--nylon band cerclage fixation and multiple intramedullary pinning (20 bones). Intact bones were significantly (P less than 0.05) stronger than repaired bones in each testing mode. Bones repaired with bands only were significantly less stiff in bending than were bones repaired with pins only or with pins and bands. In compression, only specimens repaired with pins and bands were significantly stiffer than were bones repaired with bands only. Bones repaired with bands only required significantly less load to failure in compression and in caudocranial bending than did bones repaired with pins only or with pins and bands. Bones repaired with pins only deformed through the full displacement of the actuator (5 cm), and pins deformed plastically. Bones repaired with pins and bands were stiffer and had higher bending moments than did bones repaired with pins only, but the differences were not significant.  相似文献   

14.
OBJECTIVES: To compare the monotonic biomechanical properties of a prototype equine third metacarpal dynamic compression plate (EM-DCP) fixation with a double broad dynamic compression plate (DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional testing. The EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of one randomly selected bone from each pair. Two DCPs, 1 dorsally (10-hole, 4.5 mm broad) and 1 laterally (9-hole, 4.5 mm broad) were applied to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the EM-DCP fixation were significantly greater (P<.0001) than those of the double broad DCP fixation. Mean cycles to failure in 4-point bending of the EM-DCP fixation was significantly greater (P<.0008) than that of the double broad DCP fixation. Mean yield load, composite rigidity, and failure load in torsion of the EM-DCP fixation were significantly greater (P<.0035) than that of the double broad DCP fixation. CONCLUSION: The EM-DCP provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: Results of this in vitro study support the conclusion that the prototype EM-DCP fixation is biomechanically superior to the double broad DCP fixation for the stabilization of osteotomized equine MC3.  相似文献   

15.
Objective: To determine the effect of proximal ulnar osteotomy (PUO), distal ulnar osteotomy (DUO), and DUO with release of the interosseous ligament (DOLR) on displacement of the proximal ulna at the radioulnar joint. Study Design: Experimental mechanical study. Sample Population: Cadaveric, skeletally mature canine thoracic limb pairs (n=11). Methods: Thoracic limbs disarticulated at the elbow were randomly assigned to 1 of 2 groups: (A) limbs were tested with no treatment (NOTX), then with PUO; (B) limbs were tested with DUO followed by DOLR. A distraction force was applied to the proximal ulna with the distal limb secured in a frame, and displacement of the proximal ulnar segment at the radioulnar joint was recorded. Results: Mean displacement was 0.36 mm (95% confidence interval [CI]: 0?1.12 mm) in the NOTX group, 4.68 mm (95% CI: 3.82–5.55 mm) for PUO limbs, 0.95 mm (95% CI: 0.52–1.39 mm) for the DUO group, and 4.36 mm (95% CI: 3.71–5.02 mm) for the DOLR group. Mean ulnar displacement of the DOLR group was significantly different compared with the DUO group, but there was no significant difference between the PUO and DOLR groups. Conclusions: No significant difference was observed in displacement of the proximal ulnar segment after DOLR compared with PUO.  相似文献   

16.
Osteochondritis dissecans of the sagittal ridge of the third metacarpal and metatarsal bones was diagnosed in 8 horses during an 18-month period. Seven of the horses were less than or equal to 2 1/2 years old. Synovial distention of the affected fetlock joints and a pain response to fetlock flexion were typical findings. Lameness predominated in 1 limb at a trot, although fetlock flexion frequently elicited lameness in other affected limbs. Radiography revealed bony lesions (flattening, erosion, or fragmentation) of the sagittal ridge in at least 2 fetlock joints in all horses. The onset of signs was not correlated with the severity of radiographic changes in all horses.  相似文献   

17.
OBJECTIVE: To compare monotonic mechanical properties of gap-ostectomized third metacarpal bones (MC3) stabilized with an MP35N interlocking nail system with contralateral intact bones. ANIMALS OR SAMPLE POPULATION: Twenty-four pairs of cadaveric equine MC3s. METHODS: Third metacarpal bones were divided into 4 mechanical testing groups (6 pairs per group): compression, palmarodorsal (PD) and mediolateral (ML) 4-point bending, and torsion. One MC3 from each pair was randomly selected as an intact specimen, and the contralateral gap ostectomized bone was stabilized with a 4-hole, 14-mm-diameter, 250-mm-long, MP35N intramedullary nail, and four, 7-mm-diameter, 60-mm-long MP35N interlocking screws (constructs). Mechanical testing properties were compared between intact specimens and constructs with a paired t test (significance set at P <.05). RESULTS: Intact specimens were significantly stronger and stiffer than constructs in all testing modes except PD bending. Constructs achieved mean yield strengths that were 57% (compression), 81% (PD bending), 68% (ML bending), and 78% (torque) of intact specimens. Constructs achieved mean stiffnesses that were 53% (compression), 58% (PD bending), 41% (ML bending), and 47% (torque) of intact specimens. CONCLUSION: Monotonic yield mechanical properties of MP35N intramedullary interlocking nail-stabilized, gap-ostectomized MC3 were lower than those of paired intact bones but exceeded reported in vivo loads for dorsopalmar bending and compression and estimated in vivo torsional loads. CLINICAL RELEVANCE: Considering the benefits associated with intramedullary interlocking nail fixation of fractures, this system should be considered for use for repair of MC3 fractures with applicable fracture configurations.  相似文献   

18.
19.
OBJECTIVES: To compare the monotonic biomechanical properties and fatigue life of a broad, limited contact, dynamic compression plate (LC-DCP) fixation with a broad, dynamic compression plate (DCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An LC-DCP (8-hole, 4.5 mm) was applied to the dorsal surface of 1 randomly selected bone from each pair. One DCP (8-hole, 4.5 mm broad) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: The mean 4-point bending yield load, yield bending moment, composite rigidity, failure load, and failure bending moment of LC-DCP fixation were significantly greater (P<.01) than those of broad DCP fixation. Mean cycles to failure for 4-point bending was significantly (P<.001) greater for broad DCP fixation compared with broad LC-DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion was significantly (P<.02) greater for broad LC-DCP fixation compared with broad DCP fixation. CONCLUSION: Broad LC-DCP offers increased stability in static overload testing, however, it offers significantly less stability in cyclic fatigue testing. CLINICAL RELEVANCE: The clinical relevance of the cyclic fatigue data supports the conclusion that the broad DCP fixation is biomechanically superior to the broad LC-DCP fixation in osteotomized equine MC3 bones despite the results of the static overload testing.  相似文献   

20.
OBJECTIVE: To evaluate the influence of a tibial plateau leveling jig on osteotomy orientation, fragment reduction, and postoperative tibial plateau angle (TPA) during tibial plateau leveling osteotomy (TPLO). STUDY DESIGN: In vitro experimental study. ANIMALS: Large-breed canine cadavers (n=20). METHODS: TPLO was performed on 40 hindlimbs using 4 methods. Group 1: Jig; dogs in dorsal recumbency with the osteotomy parallel to the distal jig pin. Groups 2-4: No jig; dogs in lateral recumbency with the osteotomy in a vertical orientation (group 2: tibia parallel to the table top; group 3: controlled superimposition of the femoral condyles; group 4: internal rotation of the tibia). Postoperative TPA, fragment reduction, and osteotomy orientation relative to the tibial plateau were compared. Positive or negative values denoted deviation from parallel relative to the tibial plateau. RESULTS: Postoperative TPA, fragment reduction, and proximodistal osteotomy orientation were not significantly different between groups. Craniocaudal osteotomy orientation was significantly different (P<.005) from the tibial plateau. Median deviations were -4.0 degrees (group 1), 11.8 degrees (group 2), 11.2 degrees (group 3), and 0.2 degrees (group 4). Group 1 was not significantly different from group 4. CONCLUSIONS: A jig is not essential for osteotomy orientation, tibial plateau rotation, or fragment reduction. Comparable results were achieved performing a vertical osteotomy with the tibia slightly internally rotated (10 degrees -15 degrees) and parallel to the table surface. CLINICAL RELEVANCE: TPLO without use of a jig reduces surgical trauma, is less time consuming, and reduces cost.  相似文献   