首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 12 毫秒
1.
A liquid chromatographic (LC) method was developed for determining vitamins D2 and D3 in fortified milk and infant formulas. The lipid-soluble components were extracted from the aqueous phase by homogenizing in isopropanol-methylene chloride with magnesium sulfate added to remove water. The vitamins were fractionated from the lipid material by using gel permeation chromatography (GPC) followed by further cleanup of the combined GPC fractions on a muBondapak/NH2 column. Four muStyragel (100 A) columns connected in series were used for GPC fractionation of sample extracts in methylene chloride. Injection and collection were repeated 3 times to collect enough vitamin D for quantitation. The muBondapak/NH2 column, using a mobile phase of methylene chloride-isooctane-isopropanol (600 + 400 + 1), resolved vitamin D from other UV-absorbing compounds and soy sterols in infant formula and from cholesterol in milk. Vitamins D2 and D3 coeluted as one peak, with the resolution and vitamin level sufficient for visual monitoring (280 nm/0.02 absorbance unit full scale) in a collection time of 22-26 min. A Zorbax ODS (6 micron) column and a methylene chloride-acetonitrile-methanol (300 + 700 + 2) mobile phase were used for LC quantitation; vitamins D2 and D3 were baseline resolved in about 11 min. The infant formula samples included ready-to-use and concentrated liquids prepared in nonfat milk base or soy base fortified with vitamins D2 or D3 at 400 IU/qt or L (10 micrograms). The mean percent recovery of added vitamin D3 (400-500 IU/qt) from infant formula (n = 7) was 89.6 +/- 6.7 (coefficient of variation (CV) 7.5%).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
A gas-liquid chromatographic (GLC) method, using a 4% XE-60 on 80-100 mesh Gas-Chrom Q column, a flame ionization detector, and anthracene as the internal standard, has been developed for the direct determination of nikethamide. Eight collaborators analyzed 4 samples, using methanol as the solvent; the coefficients of variation obtained ranged from 1.19 to 3.20%. In a limited study with acetone as the solvent, the coefficients of variation ranged from 0.59 to 1.96%. The GLC method with acetone as a solvent has been adopted as official first action.  相似文献   

3.
4.
5.
Gas-liquid chromatography GLC) coupled with column chromatography was used to accurately determine as little as 25 ppm p-chloroacetanilide in acetaminophen. p-Chloroacetanilide was eluted from a pH 8 phosphate-buffered diatomite partition column by using purified tetrachloroethylene (acetaminophen was retained). This solution was concentrated, internal standard (docosane) was added, and p-chloroacetanilide was determined by using a 0.9 m X 2 mm glass column packed with 3% Poly A 103 on Supelcoport and a flame ionization detector with electronic integration. Standard curves were linear for 10-100 ppm p-chloroacetanilide. Various chromatographic materials were investigated for optimal retention characteristics. High pressure liquid chromatography (HPLC) was also evaluated as an alternative; however, lack of reproducibility of the HPLC column favored the GLC procedure.  相似文献   

6.
7.
8.
A gas-liquid chromatographic (GLC) method developed by other workers for determining pentachlorophenol (PCP) in water has been adapted for determining PCP in raw and homogenized milk. PCP is extracted from milk with benzene and from the benzene into a potassium carbonate solution. Acetic anhydride is added to the aqueous solution to form PCP acetate, which is extracted into hexane and then determined by electron capture GLC. Duplicate determinations of PCP in milk fortified at levels of 0.02, 0.2, and 2.0 ppm gave respective average recoveries of 80.0, 87.2, and 85.0%. PCP levels as low as 0.005 ppm can be detected in 20 g milk.  相似文献   

9.
A method is described for the determination of vitamins D2 + D3 in milk- and soy-based infant formula. Vitamins D2 and D3 are extracted from the saponified sample and converted to isotachysterols with acidified butanol. Reverse-phase liquid chromatography (LC) is used to remove interferences, and total vitamin D is quantitated using normal-phase LC. Recoveries of spiked samples averaged 97.6% for milk-based infant formula, and 98.8% for soy-based infant formula. This method quantitates vitamin D2 + D3 in infant formulas containing as low as 40 IU/qt when prepared according to label direction.  相似文献   

10.
Gas-liquid chromatographic determination of capsaicin.   总被引:1,自引:0,他引:1  
A simple and accurate method has been developed for the quantitative determination of capsaicin in capsicum spices and their oleosresins. Capsaicin is extracted with acetone and separated from interfering substances, using an activated alumina column. The column is first eluted with acetone, and then the capsaicin is eluted with acetone-methanol-water (75+25+2). The capsaicin is quantitated by gas-liquid chromatography, using a Carbowax 20M-Teflon column and piperine as an internal standard. Results can be calculated as per cent capsaicin or Scoville units. Recovery of added capsaicin averaged 101%.  相似文献   

11.
12.
13.
A reverse phase high pressure liquid chromatographic (HPLC) method for quantitating vitamin K1 in enzymatic hydrolysates of infant formula is described. The vitamin is extracted with n-pentane before determination by isocratic and isothermal reverse phase HPLC. Recovery of vitamin K1 added to 5 infant formulas ranged from 84 to 103%.  相似文献   

14.
A gas-liquid chromatographic method is presented for determining ethopabate in 0.8 and 8.0% premixes. A sample is extracted with tetrahydrofuran containing an internal standard, by sonication or overnight soaking. The extract is clarified by centrifugation, diluted if necessary, and injected into a gas chromatograph equipped with a flame ionization detector. Average per cent recoveries for spiked blank samples were 100.6 at the 0.8% level and 100.4 at the 8.0% level. Precision, as indicated by replicate analyses of several premixes, ranged from 0.5 to 1.7% relative standard deviation.  相似文献   

15.
Vitamin D2 or vitamin D3 is determined by liquid chromatography (LC) in milk and infant formula. Vitamin D is extracted from the saponified sample, passed through an amino-cyano LC cleanup column to remove major interferences, and quantitated using normal phase LC. Within-day precision is 4.5% relative standard deviation (RSD); the overall method RSD (reflecting technician-to-technician, day-to-day, and within-day variability) is 7.7%. Overspike recoveries averaged 97% for milk, 98% for milk-based infant formula, and 93% for soy-based infant formula. The performance of the method is compared with that of the official AOAC vitamin D method (rat bioassay). The method is applicable to the determination of vitamin D in milk and in the major milk- and soy-based infant formulas available in the United States. The method can quantitate (but not distinguish) either vitamin D2 or vitamin D3. The method is applicable to milk and infant formula samples containing between 100 and 1500 IU vitamin D/L. Sample throughput is between 4 and 8 replicates per day.  相似文献   

16.
17.
18.
A gas-liquid chromatographic (GLC) method was developed for the detection and determination of thiourea in citrus peels. After the peel is extracted with ethyl ether, the ether extract is adsorbed on sodium sulfate together with water. Thiourea is recoverd from both the sodium sulfate and the peel residue with ethyl acetate-acetone(2+1). The extracted mixture is cleaned on an alumina column, the eluate is concentrated under vacuum, and thiourea is extracted from the concentrate with sodium carbonate solution. GLC was carried out on the prepared benzoyl derivative of thiourea. The average recoveries of thiourea from lemon peel were 85.3, 93.1, and 97.6% at the fortification levels of 1, 10, and 100 ppm, respectively. The detection limit was low as 0.08 ppm.  相似文献   

19.
20.
A method is presented for the determination of permethrin (m-phenoxybenzyl cis,trans-(+/-)-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropanecarboxylate) in bovine tissues. Fat and muscle samples were cleaned up first by liquid-liquid partition on a bonded phase chromatographic column. Final cleanup of fat and muscle was performed on a short Florisil column. Liver, kidney, spleen, and heart tissues only required cleanup on a Florisil column before quantitation of permethrin by electron capture gas-liquid chromatography.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号