首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents a three-phase four - wire active power filter based on one-cycle control. This method need not sense the three phase load currents or the three phase voltages, need not use any multipliers. It has simplified circuit , and the controller is composed of four integrators with reset along with several flip-flops, comparators and some analog components. The main circuit switching frequency is constant, which is desirable for industrial applications. Analysis and simulation are carried out with the four-arm inverter, the simulation results verify that the APF with one-cycle control can dynamically and effectually compensate the harmonics, reactive current and zero sequence current.  相似文献   

2.
As one-cycle controlled single-phase active power filter(APF) only can compensate harmonics and reactive currents simultaneously,this paper detects circuit based on instantaneous reactive theory and current traces control circuit based on one-cycle control with harmonic current.The control equations and circuit are set up.The results of simulation verify that this scheme is effective and APFs can compensate harmonic and reactive current according to requirement with the distorted source voltages.  相似文献   

3.
To solve the problem of low control accuracy and low stability of current X-ray machines, a kind of digital power supply for X-ray machine is introduced. In the digital power supply, some key technologies are used to improve the output stability of the high frequency inverter, including improved BUCK circuit for voltage regulating circuit, high frequency inverter and soft switching technology for the high-voltage generator. The PWM control technology is used to control the switch transistor of voltage regulating circuit and inverter circuit, which makes the drive waveform output stable and easy to control. In order to improve the control accuracy, reduce the volume and change high voltage consecutively, the software PID of the microcomputer is used to control the feedback circuit. The high-accuracy power chip is used for the filament power supply to make the filament electric current stable. Through the analysis of the circuit, the parameters of the circuit are calculated and the circuit is simulated by PSPICE software. The results show that the theoretical analysis is consistent with the practical simulation results. The design can meet the requirement of the technology indices of the power supply of the X-ray machines.  相似文献   

4.
针对光伏发电系统在不同天气状况下发电功率预测精度不高的问题,在分析传统方法的基础上,提出一种无迹卡尔曼滤波神经网络光伏发电预测方法。该方法利用无迹卡尔曼滤波实时更新神经网络模型的权重,以直流电压和电流作为系统的输入,以有功功率和无功功率作为系统的输出,分别建立两个独立的双输入单输出功率预测模型。实验结果表明:所提出的方法对有功功率和无功功率的预测精度分别为97.3%和94.2%,并且对天气具有良好的鲁棒性。  相似文献   

5.
Grounded on the theory of power equilibrium, a novel single phase series active power filter (APF) is proposed . By analyzing the power equilibrium character of series APF, the control algorithm and equation are deduced. In the proposed control strategy, instead of the fundamental current detection and complex computation, only the capacitance voltage and the source current on d.c. side are needed. The clear control loop has been realized with simple circuit and the series proposed APF can compensate both reactive and harmonic current simultaneously. The simulation results show the excellent compensation effect and confirm the validity of theoretical analysis.  相似文献   

6.
As for the drive of control system in electric vehicles, if the inverter power is supplied by a constant DC-link voltage, there are some disadvantages in the system, such as small utilization of the voltage, big current harmonic distortion of the motor windings. A new strategy for vector control of permanent magnet synchronous motor (PMSM) with variable DC-link voltage is proposed, which is suitable for electric vehicles. According to the reference voltage amplitude of the inverter, the new system uses bidirectional DC/DC converter to adjust the DC-link voltage to improve the performance of the vector control system. At last, the whole system is simulated with MATLAB software. The simulation results show that the new strategy for vector control can increase voltage utilization, decrease torque ripple, improve current waveform effectively and decrease the total harmonic distortion of motor current. The results also verify the effectiveness and feasibility of the new strategy.  相似文献   

7.
Based on the reactive surplus of Chongqing 220 kV main electric power network under low water and low load, and on state of higher system voltage, a thorough research is done on voltage and reactive power of the system power network by means of calculation,analysis and experiments. A main network calculating equivalence model of power network in Chongqing is constructed. And reactive power optimizing calculation is figured out on the Chongqing power network on condition that the loss minimum of the active power network is object function. Several optimizing compensatory schemes are put forward. Based on the calculation result and the analysis of all schemes, the most reasonable and feasible optimizing scheme could be achieved. Meanwhile, the feasibility that the system voltage could be adjusted when generator operating under excitation was demonstrated. According to the experience of under-excitation operation of the same type units , it decreases the system voltage, improves Chongqing power network running performance, and strengthens the coordination and stabilization of system.  相似文献   

8.
This paper presents a new hierarchical and coordinative control method for reactive power optimization in large-scale interconnected power systems. It combines the interconnection forecast method for hierarchical control in large-scale steady state industrial systems with the incremental linear programming method for reactive power optimization in real time. The results of applying the method to power system examples show that the method not only solves the problem of high dimension in order, but also keeps the advantages of the incremental linear programming method. The proposed method is also suitable for the security analysis of reactive power correction in large-scale interconnected power systems.  相似文献   

9.
This paper discusses about maximum power tranrfer from the active resistive network to the passive reactive network, and derives the condition that the load network must satisfy when the power transfer is maximum, and gives some examples about its application.  相似文献   

10.
The computer monitor and control system for hydropower station is always a structure system of laminate distribution and open style. The system can adjudge active power and inactive power of water turbine according to the requirement. The operators in active-control level give the value of active power and inactive power for water turbine by computer workstation. PLC of LCU run the power control procedure by net communication in order to realize power adjust. The power adjust of water turbine mainly by speed control system and magnetization system. The 2-D Fuzzy PID Control Model is proposed in order to carry out power adjust of water turbine . In this new method the parameter of PID can self-neaten on line according to power deviation and power deviation rate. By means of this procedure the machine unit can obtain given power value rapidly, exactly and stably. It can make the power adjust of monitor and control system obtain good control characteristic and robust, and it is benefit to extend the work life of machine unit.  相似文献   

11.
This paper has applied the var cost to the theory of spot price.An augmented Lagrange method is employed to develop the exact model of spot price of active power and reactive power,and the physical means of Lagrange multipliers are explained.The numerical examples are given to demonstrate the validity of the proposed model.  相似文献   

12.
This paper discuas the controlling principle of asynchronized turbogenerators,deduces their mathematical model,and studies their regulating characteristics of real and reactive power(or voltage)by means of simulation calculation of operating characteristics for a 200MW asychronlzed turbogenerator.The conclusion is that the asychronlzed tubogenerators not only can regulate real and reactive power independently but also has an excellent dynamic performance.  相似文献   

13.
The voltage instability of power system often occurs when the active power on one or more weak branches exceeds its transfer capability. A preventive control model for static voltage stability is proposed using the active power transfer capability of weak branches as static voltage stability constraints. A local line based voltage stability index is used to determine the critical contingencies, weak branches and transfer capability of each weak branch. A static security analysis method, which is based on DC power flow equations, is used to establish the non linear active power flow expressions on weak branches following each critical contingency. The active power constraints on weak branches can be obtained from the active power flow expressions and transfer capabilities of weak branches. A quadratic optimal model for preventive control including the proposed active power constraints on weak branches is presented. The simulation results for IEEEE14 bus system and IEEE118 bus system demonstrate the correctness and effectiveness of the proposed preventive control model.  相似文献   

14.
A new approach based on sensitivity method for the optimal power flow is presented in the paper. This method has the following advantages: it is suitable to solve a 200-node power system on the microcomputer; the convergence is easy to reach and the computation speed is quick; it is possible to reduce 8-14% power loss and to get maximum economic benefit by using this method; in power system dispatch center it can be used as an on-line voltage and reactive power control program to keep good voltage level. The proposed method has been proved successful by IEEE 118-node test system and the several real power systems such as 49-node, 61-node, 99-node and 200-node systems.  相似文献   

15.
A method introducing fictious variables for resolving the linear model of reactive power and voltages control in power systems is presented. The method theoritically guarantees the resolvability and optimizition of linear programming model. This method has been proved successful by IEEE 6 -node test system and the several practical power systems such as 49-node, 155 -node systems.  相似文献   

16.
Considering the characteristics of the dc side series active power filter (APF) that the output voltage cannot be adjusted and the control circuit is complex , an improved single phase dc series APF topology is proposed. The improvement of the new circuit topology and fundamental working principle are analyzed. Following the circuit power factor pre regulator principle, the designing method for the main circuit parameters is given. The voltage ring and the current ring are designed by using the zero pole method. The main circuit power switch is controlled with the same frequencies, while the control circuit was simplified further. Compared with the paralleled APF, the main circuit of topology structure is simplified and the number of the active switches is reduced, which show low input current harmonics, high power factor, large voltage output adjustment range and low cost. The simulation results prove that the proposed topology is correct and reliable.  相似文献   

17.
An A. C. load flow analysis of the reliability evaluation of composite generation and transmission systems is presented on the basis of a fast outage simulation algorithm and an optimal model of active and reactive power adjustment after outage contingencies. The information of the first -level outage events is utilized for simulating higher -level outage events in the fast outage simulation algorithm ; the optimal model is satisfactory in speed and accuracy with the application of concentric relaxation and linear increment constraint on the comprehensive adjustment of active and reactive power. As an example. the IEEE Reliability Test System is tested and the results show that the method is accurate and well-matched in speed with the method studied by R. Bllinton, et al.  相似文献   

18.
In this paper, a predictive control approach using neural networks for active power filter is proposed. The control system of active power filter using this method make using of the internal model control technology based on neural networks, meanwhile, to solve its questions such as lag because of calculating using neural networks, a predictive model based on neural networks is introduced. Simulation analysis shows that this control approach can compensate the lag of system and take advantage of self-adaptive characteristic of neural networks. Good result can be obtained.  相似文献   

19.
基于LabVIEW的潜油电泵数据采集系统   总被引:1,自引:0,他引:1  
应用LabVIEW虚拟仪器现场可编程门阵列(FPGA)对潜油电泵的电压、电流参量进行实时数据采集,通过上位机对采样数据进行分析处理,得到潜油电泵的视在功率、有功功率、无功功率和功率因数,并与电能质量检测仪检测数据进行对照。系统硬件采用NI sbRIO-9606和NI9683夹层板配合使用,突破了传统的依靠DAQ助手的硬件采集,基于现场可编程门阵列(FPGA)的数据采集系统,由软件构成采集功能芯片,可控性强,准确性高,应用性好。实验表明,该系统在误差允许范围内能够对数据进行准确采集。  相似文献   

20.
This paper describes an application of evolutionary programming(EP) to reactive power optimization and voltage control of power systems.Some technical problems which conclude mutation sacle,fitness value and population size have been solved to make EP practical for solving the optimal power flow problems.The computational results with EP have been compared with those obtained from a conventional gradient based optimization method.The comparision shows that EP are better than conventional methods in dealing with the optimization of noncontinuous and nonsmooth funcnons.The EP show the ability to search for the global optimum in reactive optimization that has multiple optima.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号