首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Effects of ventriculectomy and prosthetic laryngoplasty on upper airway flow mechanics and blood gas tensions in exercising horses with induced left laryngeal hemiplegia were assessed. Five adult horses were trained to stand, trot (4.5 m/s), and gallop (7.2 m/s) on a treadmill (6.38 degrees incline). Inspiratory and expiratory airflows (VImax, VEmax, respectively) were measured using a 15.2-cm diameter pneumotachograph in a face mask. Inspiratory and expiratory transupper airway pressures (PuI, PuE, respectively) were determined as pressure differences between barometric pressure and lateral tracheal pressure. Blood collected from exteriorized carotid arteries was analyzed for PaO2, PaCO2, pH, hemoglobin (Hb) content, and HCO3- values. Heart rate (HR) was determined with an HR monitor. Measurements were made with horses standing, trotting, and galloping before left recurrent laryngeal neurectomy (LRLN; base line), 14 days after LRLN, 30 days after ventriculectomy (44 days after LRLN), and 14 days after prosthetic laryngoplasty (58 days after LRLN). Before LRLN (base line), increasing treadmill speed for horses from standing to the trot and gallop progressively increased HR, respiratory frequency, VImax, VEmax, PuI, PuE, Hb, and PaCO2 values and decreased PaO2, pH, and HCO3- values; inspiratory and expiratory impedances were unchanged. After LRLN, inspiratory impedance and PuI were significantly (P less than 0.05) increased in horses at the trot and gallop, and PaCO2 was significantly increased in horses at the gallop. The VImax and respiratory frequency were significantly (P less than 0.05) decreased in horses at the gallop. Left recurrent laryngeal neurectomy had no effect on PuE, VEmax, HR, PaO2, pH, Hb, or expiratory impedance values.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
OBJECTIVE: To report the effect of unilateral laser vocal cordectomy on respiratory noise and airway function in horses with experimentally induced laryngeal hemiplegia (LH). STUDY DESIGN: Experimental study. ANIMALS: Six Standardbred horses without upper airway abnormalities at rest or during high-speed treadmill exercise. METHODS: Respiratory sounds and inspiratory trans-upper airway pressure (P(Ui)) were measured before (baseline) and 14 days after induction of LH by left recurrent laryngeal neurectomy, and again 30, 60, 90, and 120 days after endoscopically assisted laser cordectomy of the left vocal cord. Data were collected with the horses exercising on a treadmill at a speed producing maximum heart rate (HR(max)). RESULTS: In horses exercising at HR(max), induction of LH caused a significant increase in P(Ui), sound level (SL), and the sound intensity of formant 2 (F(2)) and 3 (F(3)). The sound intensity of formant 1 (F(1)) was unaffected by induction of LH. Laser vocal cordectomy had no effect on SL, or on the sound intensity of F(1) and F(3). At 30, 60, 90, and 120 days after surgery, P(Ui) and the sound intensity of F(2) were significantly reduced, but these variables remained significantly different from baseline values. CONCLUSIONS: Unilateral laser vocal cordectomy did not effectively improve upper airway noise in horses with LH. The procedure decreased upper airway obstruction to the same degree as bilateral ventriculocordectomy. CLINICAL RELEVANCE: Currently, laser vocal cordectomy cannot be recommended for the treatment of upper airway noise in horses with LH.  相似文献   

3.
During the years 1971-1979, 127 horses with left laryngeal hemiplegia were studied. The physical characteristics and clinical signs observed in this study were recorded in Part I and Part II of ths series of papers. Of these 127 horses, 81 were treated by the laryngoplasty procedure. Complications of surgery are described and the effects of the operation on respiratory noise and performance are evaluated. In 54.8% of horses the chronic respiratory noise observed during exercise was apparently diminished or eliminated post-operatively. The performance of 44% of horses was apparently improved after surgery. Post-operative racing success occurred in 38% of horses treated. Satisfactory arytenoid adduction as assessed endoscopically within 9 days of surgery was achieved in 77% of cases. Surgical failure appeared to be related to cutting of the laryngeal cartilages by the prosthesis and techniques to minimise this are discussed.  相似文献   

4.
REASONS FOR PERFORMING STUDY: Laryngoplasty is the technique of choice for treatment of laryngeal hemiplegia, with the aim of improving airway function and/or eliminating respiratory noise. However, there are no quantitative data in the literature describing the effect of laryngoplasty on upper airway noise or its relationship to upper airway mechanics in horses with laryngeal hemiplegia. OBJECTIVES: To determine whether laryngoplasty reduces respiratory noise in exercising horses with laryngeal hemiplegia; and to establish whether the degree of upper airway obstruction can be predicted by upper airway noise, or the degree of arytenoid abduction correlated with airway obstruction and noise production. METHODS: Six Standardbred horses with normal upper airways during maximal exercise were used. Respiratory sounds and inspiratory transupper airway pressure (Pui) were measured in all horses before and after induction of laryngeal hemiplegia and 30, 60 and 90 days after laryngoplasty. Inspiratory sound level (SL) and the sound intensity of the 3 inspiratory formants (F1, F2 and F3, respectively) were measured using a computer-based sound analysis programme. The degree of abduction was graded by endoscopic visualisation 1, 30, 60 and 90 days post operatively. Linear regression analysis was used to determine correlations between Pui, sound indices and grades of arytenoid abduction. RESULTS: In laryngeal hemiplegia-affected horses, Pui, inspiratory SL and the sound intensity of F1, F2 and F3 were significantly increased. At 30 days following laryngoplasty, the sound intensity of F1 and Pui returned to baseline values. The sound intensities of F2, F3 and SL were significantly improved from laryngeal hemiplegia values at 30 days post operatively, but did not return to baseline at any measurement period. Sound level, F2 and F3 were significantly correlated with Pui (P<0.05), but the correlations were weak (r2 = 0.26, 035 and 0.40, respectively). Grade of abduction and F2 were positively and significantly correlated (P<0.006, r2 = 0.76). Grade of arytenoid abduction and Pui were not correlated (P = 0.12). CONCLUSIONS: Laryngoplasty reduced inspiratory noise in laryngeal hemiplegia-affected horses by 30 days following surgery, but did not return it to baseline values. While upper airway noise and Pui were correlated, this relationship was insufficiently strong to predict Pui from noise in individual animals. The degree of arytenoid abduction was not correlated with Pui, but was positively correlated with noise production. POTENTIAL RELEVANCE: Laryngoplasty reduces upper airway noise in horses with laryngeal hemiplegia, but is not as effective as bilateral ventriculocordectomy in this regard, although respiratory noise reduction occurs more rapidly than with bilateral ventriculocordectomy. Residual noise during exercise cannot be used as a predictor of improvement in upper airway function in individual horses following laryngoplasty. The degree of arytenoid abduction obtained following surgery does not affect upper airway flow mechanics. Interestingly, we found that the greater the arytenoid abduction, the louder the respiratory noise.  相似文献   

5.
The effect of left laryngeal hemiplegia on airway flow mechanics in 5 exercising horses was examined, and the efficacy of surgical repair by prosthetic laryngoplasty was evaluated. Measurements of the upper airway flow mechanics were made with horses on a treadmill (incline 6.38 degrees) while standing (period A); walking at 1.3 m/s (period B); trotting at 2.6 m/s (period C); trotting at 4.3 m/s (period D); and standing after exercise (period E). Experiments were done on healthy horses before any surgical manipulation (control), at 10 days after left recurrent laryngeal neurectomy, and at least 14 days after prosthetic larynogoplasty. Increasing treadmill speed from period A to period D progressively increased heart rate, respiratory frequency, peak inspiratory flow, and peak expiratory flow, but inspiratory resistance and expiratory resistance remained unchanged. Neither left recurrent laryngeal neutrectomy nor prosthetic laryngoplasty affected heart rate, respiratory frequency, peak expiratory flow, or expiratory resistance when compared with those values at the control measurement periods. Left recurrent laryngeal neurectomy resulted in inspiratory flow limitation at peak inspiratory flow of approximately 25 L/s, and increased inspiratory resistance at periods D and E. Subsequent prosthetic laryngoplasty alleviated the flow limitation and reduced inspiratory resistance at measurement periods D and E.  相似文献   

6.
OBJECTIVE: To compare upper airway mechanics, arterial blood gases, and tracheal contamination in horses with induced left laryngeal hemiplegia (recurrent laryngeal neuropathy [RLN]) treated by laryngoplasty/vocal cordectomy (LPVC) or modified partial arytenoidectomy (MPA). STUDY DESIGN: Repeated measures under the following conditions: Control, RLN, LPVC, and MPA. ANIMALS: Six horses. METHODS: Two trials were conducted under all conditions at 80% and 100% of maximal heart rate (HR(max)). In Trial 1, arterial blood gases, tracheal and pharyngeal pressures, and laryngeal videoendoscopy were recorded. In Trial 2, upper airway pressure and airflow were determined. Tracheobronchial aspirates were performed after exercise to quantify airway contamination. RESULTS: Compared with control, RLN significantly increased inspiratory impedance and worsened exercise-induced hypoxemia. At 80% HR(max), LPVC restored most variables to control values. At 100% HR(max), LPVC improved all variables, but did not restore minute volume, arterial pH, and PaCO(2). At 80% HR(max), MPA restored all variables except bicarbonate to control values. At 100% HR(max), MPA improved all variables, but did not statistically restore minute ventilation or bicarbonate level. Only minor differences were noted between LPVC and MPA. Both resulted in equivalent tracheal contamination. CONCLUSIONS: Airway mechanics and arterial blood gas values were not restored to normal after either LPVC or MPA in horses exercising at HR(max). This does not affect ventilation at sub-maximal exercise, but has clinical implications at HR(max). Both procedures diminish normal laryngeal protective mechanisms. CLINICAL RELEVANCE: At sub-maximal exercise intensities both LPVC and MPA restore airway ventilation to normal. At maximal exercise the superiority of LPVC over MPA is slight.  相似文献   

7.
OBJECTIVE: To examine the effect of cordopexy, laryngoplasty, and cordopexy combined with a modified laryngoplasty on airway mechanics. STUDY DESIGN: Experimental airway mechanics were determined by subjecting equine cadaveric larynges to airflows similar to inspiratory airflow of exercising horses. ANIMALS OR SAMPLE POPULATION: Twenty equine larynges. METHODS: Using cadaveric larynges, we developed and tested a new technique of arytenoid cartilage abduction. All larynges had the right arytenoid cartilage abducted to mimic the degree of arytenoid abduction that occurs at maximal exertion in live horses. Three surgical techniques were used to stabilize the left arytenoid cartilage of treated larynges; the left arytenoid cartilage was not stabilized in control larynges. Technique 1: Cordopexy--a suture was placed between the vocal ligament and the lamina of the thyroid cartilage. Technique 2: Standard laryngoplasty--a suture was placed between the muscular process of the arytenoid cartilage and the caudomedial aspect of the cricoid cartilage. Technique 3: Cordopexy plus modified laryngoplasty--the cordopexy suture was placed with a second suture between the horizontal ridge rostral to the muscular process of the left arytenoid cartilage and the lamina of the thyroid cartilage. Translaryngeal impedances (TI) were determined for each surgical technique by subjecting the larynges to increasing airflows and measuring the translaryngeal pressure differences. The arytenoid right to left angle quotient (RLQ) and the glottic cross-sectional area (CSA) were also measured. RESULTS: At maximal airflow, the adjusted means for the arytenoid RLQ and the TI for the cordopexy plus modified laryngoplasty (1.48 +/- 0.04, 0.69 +/- 0.05 cm H2O/L/s) and the standard laryngoplasty (1.39 +/- 0.04, 0.78 cm H2O/L/s) were different (P < .05) from values obtained after cordopexy alone (2.74 +/- 0.37, 1.76 +/- 0.48 cm H2O/L/s) or in control larynges (3.66 +/- 0.54, 4.16 +/- 0.96 cm H2O/L/s). Overall, a cordopexy plus modified laryngoplasty (9.69 cm2), a standard laryngoplasty (9.34 cm2), and a cordopexy alone (9 cm2) resulted in an increased glottic CSA greater than that for control larynges (6.94 cm2; P = .0001). CONCLUSIONS: Cordopexy alone did not improve airflow in a left laryngeal hemiplegic model. Cordopexy plus modified laryngoplasty was as efficacious as the standard laryngoplasty in alleviating the effects of left laryngeal hemiplegia on TI, glottic CSA, and arytenoid RLQ. CLINICAL RELEVANCE: Fixation of the vocal cord (cordopexy) in addition to a laryngoplasty procedure may prove useful in the surgical treatment of equine laryngeal hemiplegia.  相似文献   

8.
9.
Thirty-eight horses suspected of having laryngeal hemiplegia had electromyograms (EMGs) performed on the dorsal cricoarytenoid muscle (DCAM). Electromyographic abnormalities consisted of fibrillation potentials, positive sharp waves, bizarre high frequency discharges, and reduced insertional activity. Normal motor activity consisted of motor unit activity during inspiration, or less frequently motor unit activity during inspiration with subsequent tonic motor activity. In affected muscles, motor unit activity was often absent but when present there was activity consisting of motor units which did not correspond to a particular phase of respiration or it was consistent with normal motor unit activity.  相似文献   

10.
REASONS FOR PERFORMING STUDY: Show and performance horse with laryngeal hemiplegia (LH) often present for excessive respiratory noise rather than significant exercise intolerance. Therefore, the goal of surgery in these horses is to reduce respiratory noise but there are no quantitative studies evaluating the effect of any upper-airway surgery in LH-affected horses. OBJECTIVE: To determine whether bilateral ventriculocordectomy (VC) reduces respiratory noise in exercising horses with laryngeal hemiplegia. METHODS: Six Standardbred horses with normal upper airways were used in this study. Respiratory sounds and inspiratory trans-upper airway pressure (Pui) were measured in all horses before and after induction of LH, and 30, 90 and 120 days after VC. In horses with LH, spectrogram analysis revealed 3 inspiratory sound formants centred at approximately 400, 1700 and 3700 Hz. Inspiratory sound levels (SL) and the sound intensity of the 3 inspiratory formants (F1, F2, F3 respectively) were measured using a computer-based sound analysis programme. RESULTS: In LH-affected horses, Pui, inspiratory SL and the sound intensity of F2 and F3 were significantly increased compared to baseline values. At 90 and 120 days after VC the sound intensities of F2 and F3 returned to baseline values. The Pui and SL, were significantly decreased compared to LH values, but remained different from baseline. CONCLUSIONS: VC effectively reduces inspiratory noise in LH-affected horses by 90 days following surgery. Inspiratory trans-upper airway pressures are improved 30 days following VC, but do not return to baseline values. POTENTIAL RELEVANCE: VC can be recommended as a surgical treatment of LH-affected horses if reduction of respiratory noise is the primary objective of surgery. Further studies are required to determine if variations of the surgical technique used in this study will have similar results.  相似文献   

11.
REASONS FOR PERFORMING STUDY: Recent studies have evaluated surgical techniques aimed at reducing noise and improving airway function in horses with recurrent laryngeal neuropathy (RLN). These techniques require general anaesthesia and are invasive. A minimally invasive transnasal surgical technique for treatment of RLN that may be employed in the standing, sedated horse would be advantageous. OBJECTIVE: To determine whether unilateral laser-assisted ventriculocordectomy (LVC) improves upper airway function and reduces noise during inhalation in exercising horses with laryngeal hemiplegia (LH). METHODS: Six Standardbred horses were used; respiratory sound and inspiratory transupper airway pressure (Pui) measured before and after induction of LH, and 60, 90 and 120 days after LVC. Inspiratory sound level (SL) and the sound intensities of formants 1, 2 and 3 (Fl, F2 and F3, respectively), were measured using computer-based sound analysis programmes. In addition, upper airway endoscopy was performed at each time interval, at rest and during treadmill exercise. RESULTS: In LH-affected horses, Pui, SL and the sound intensity of F2 and F3 were increased significantly from baseline values. At 60 days after LVC, Pui and SL had returned to baseline, and F2 and F3 values had improved partially compared to LH values. At 90 and 120 days, however, SL increased again to LH levels. CONCLUSIONS: LVC decreases LH-associated airway obstruction by 60 days after surgery, and reduces inspiratory noise but not as effectively as bilateral ventriculocordectomy. POTENTIAL RELEVANCE: LVC may be recommended as a treatment of LH, where reduction of upper airway obstruction and respiratory noise is desired and the owner wishes to avoid risks associated with a laryngotomy incision or general anaesthesia.  相似文献   

12.
Right recurrent laryngeal neuropathy (RLN) is an uncommon, acquired disease for which the aetiology can frequently be diagnosed. Numerous aetiologies have been proposed for right‐sided RLN which comprises 2% of all cases of RLN. In this report we discuss the clinical course, treatment and outcome following right‐sided laryngeal paralysis as a complication of left‐sided prosthetic laryngoplasty in a horse. To the authors' knowledge, this is the first report of such a surgical complication.  相似文献   

13.
Reasons for performing study: Little is known about the efficacy of bilateral ventriculectomy (VE) or bilateral ventriculocordectomy (VCE) in draught horses. Objectives: To compare the effect of VE and VCE on upper airway noise in draught horses with recurrent laryngeal neuropathy (RLN) by use of quantitative sound analysis techniques. Hypothesis: In competitive draught horses with grade 4 RLN, VE and VCE reduce upper airway noise during exercise, but VCE is more effective. Methods: Thirty competitive hitch or pulling draught horses with grade 4 RLN were evaluated for upper airway sound during exercise. Respiratory rate (RR), inspiratory (Ti) and expiratory time (Te), the ratio between Ti and Te (Ti/Te), inspiratory (Sli) and expiratory sound levels (Sle), the ratio between Sli and Sle (Sli/Sle), and peak sound intensity of the second formant (F2) were calculated. Eleven horses were treated with VE and 19 with VCE. After 90 days of voice and physical rest and 30 days of work, the horses returned for post operative upper airway sound evaluation and resting videoendoscopy. Results: VE significantly reduced Ti/Te, Sli, Sli/Sle and the sound intensity of F2. Respiratory rate, Ti, Te and Sle were unaffected by VE. VCE significantly reduced Ti/Te, Ti, Te, Sli, Sli/Sle and the sound intensity of F2, while RR and Sle were unaffected. The reduction in sound intensity of F2 following VCE was significantly greater than following VE. After VE and VCE, 7/11 (64%) and 15/18 (83%) owners, respectively, concluded that the surgery improved upper airway sound in their horses sufficiently for successful competition. Conclusions: VE and VCE significantly reduce upper airway noise and indices of airway obstruction in draught horses with RLN, but VCE is more effective than VE. The procedures have few post operative complications. Potential relevance: VCE is recommended as the preferred treatment for RLN in draught horses. Further studies are required to evaluate the longevity of the procedure's results.  相似文献   

14.
A prosthesis, composed of a steel cable and stress-reducing washers, was developed to prevent failure of laryngoplasty, a common treatment for horses affected by recurrent laryngeal neuropathy. Laryngoplasties were performed on 15 cadaveric larynges using a polyester suture on one side and the cable prosthesis on the other. Each prosthesis was distracted at a displacement rate of 20 mm/s using a servohydraulic materials testing machine until laryngoplasty failed. Distraction force and actuator displacement were recorded and analysed. All 15 laryngoplasties performed with a suture failed at the muscular process at a mean +/- s.d. force of 55.8 +/- 13.1 N. Six laryngoplasties performed with the cable prosthesis failed at the muscular process at mean force 219.6 +/- 125.0 N. In the other 9, the arytenoid cartilage was avulsed from the larynx at mean force 206.4 +/- 75.3 N, and the cable then tore through the muscular process at mean force 357.0 +/- 32.0 N. The difference in force required to cause failure of laryngoplasty was significant (P<0.0001). Although the prosthesis resisted substantially higher forces than did the suture, the effects of the prosthesis in vivo must be evaluated.  相似文献   

15.
Recurrent laryngeal neuropathy (RLN) has been recognised for two centuries in horses. Surveys undertaken in Europe and the United States have reported that prosthetic laryngoplasty is the most common treatment for RLN, particularly for advanced cases. Despite widespread adoption of this surgical technique for treatment of RLN, reported success rates still vary widely, particularly in horses used for high intensity exercise where outcomes are often considered moderate, at best. Studies evaluating the outcome of the procedure are complicated by the use of variable criteria for measuring success, various modifications in the procedure, differing athletic demands in horses used in different equine disciplines and horses lost to follow‐up. Furthermore, post operative complications appear to be common, in particular, the effects of the surgery on airway dynamics which are not completely understood. Proposed modifications to the technique may provide a means of improving success rates; however, standardised objective measurements taken before and after surgery are required to effectively evaluate the potential benefits and outcomes of the procedure.  相似文献   

16.
The efficacy of a nerve muscle pedicle (NMP) graft in restoring upper airway function was evaluated in exercising horses with induced left laryngeal hemiplegia. The NMP graft was created from the first cervical nerve and the omohyoideus muscle and transplanted into the left cricoarytenoideus dorsalis muscle. Seven adult Standardbreds were trained to exercise on a treadmill inclined at 6.38 degrees. With the horses at rest and exercising at 4.2 and 7.0 m/s, the following variables were recorded: peak inspiratory and expiratory transupper airway pressures (defined as the pressure difference between a lateral tracheal catheter and a mask catheter), peak inspiratory and expiratory air flow, inspiratory and expiratory impedance, tidal volume, minute ventilation, heart rate, and respiratory frequency. Measurements were made before left recurrent laryngeal neurectomy (LRLN), 28 days after LRLN, and 12, 24, and 52 weeks after the NMP graft (n = 5) or sham operation (n = 2). Before LRLN, exercise increased inspiratory and expiratory air flow and transupper airway pressure, whereas the impedance was unchanged. After LRLN, transupper airway inspiratory pressure and impedance were significantly greater and inspiratory air flow was significantly less than baseline values at 7.0 m/s. The sham operation did not improve airway function. Twelve weeks after insertion of the NMP graft, inspiratory impedance and inspiratory air flow were significantly different (improved) from LRLN values. Twenty-four weeks after insertion of the NMP graft, inspiratory impedance was not significantly different from LRLN values.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

17.
Four variations of abductor muscle prosthesis for treating laryngeal hemiplegia were evaluated in 153 horses by questionnaire, and in the 100 Thoroughbred racehorses in this group survival analysis was used to compare their racing performances and earnings with those of 400 control horses. The questionnaire indicated that the technique which included a ventriculectomy and 2 prostheses was regarded as being the most successful (P less than 0.01) and resulted in the least residual stertor (P less than 0.001). Survival analysis showed that there was no significant difference between the treated group of horses and the control horses (P greater than 0.05).  相似文献   

18.
Reasons for performing study: The risk of respiratory conditions, such as inflammatory airway disease (IAD) and exercise‐induced pulmonary haemorrhage (EIPH), are thought to be higher in racehorses that undergo prosthetic laryngoplasty with ventriculocordectomy (PLVC) surgery to treat left‐sided laryngeal hemiplegia (LLH) than in racehorses with normal laryngeal function. However, this has not been investigated formally owing to the difficulty of obtaining reliable follow‐up data. Objectives: To determine the incidence of respiratory conditions (IAD and EIPH), duration of racing career, number of starts and number of starts for which stakes money was earned in racehorses that had undergone PLVC surgery to treat LLH, compared with racehorses that did not have LLH or undergo any laryngeal surgery. Methods: A retrospective cohort study design was used, with surgical, clinical and race data of Thoroughbred racehorses obtained from the time of importation until retirement. The surgical cohort consisted of racehorses that had undergone PLVC for LLH and met specific inclusion criteria. Every surgical case was matched, according to trainer, year of import into Hong Kong and pre‐import international handicap rating, to 2 unexposed racehorses. Results: Respiratory conditions, such as excessive tracheal mucus and epistaxis due to severe EIPH, were significantly increased in the surgical cohort, compared with the matched unexposed cohort (P values <0.001 and <0.004, respectively). Racing career duration in the surgical cohort was significantly shorter than in the unexposed cohort, which was primarily due to retirement because of epistaxis. The number of race starts was fewer in the surgical than in the unexposed cohort after surgery/matching, but the number of starts for which stakes money was earned was not significantly different. Conclusions and potential relevance: Owners and trainers should be advised that racehorses with LLH that undergo PLVC surgery are at an increased risk of respiratory conditions (IAD and severe EIPH), which is likely to shorten their racing career compared to racehorses with normal laryngeal function. Racing performance in terms of race starts was significantly less in racehorses that had undergone PLVC surgery; however, the number of starts for which stakes money was earned was similar to those racehorses that were unexposed.  相似文献   

19.
OBJECTIVE: To determine long-term effects of transendoscopic, laser-assisted ventriculocordectomy (LAVC) on airway noise and performance in horses with naturally occurring left laryngeal hemiplegia. DESIGN: Retrospective case series. ANIMALS: 22 horses with left laryngeal hemiplegia treated by means of LAVC. PROCEDURES: Medical records were reviewed and initial complaint, intended use of the horse, duration of abnormal airway noise, preoperative performance level, endoscopic findings, surgical procedure, postoperative treatment, and complications were recorded. Follow-up telephone interviews with owners and trainers were conducted to determine time for return to intended use, level of postoperative performance, and percentage reduction in airway noise. RESULTS: All horses were examined because of excessive airway noise; 10 (45%) had concurrent exercise intolerance. Left ventriculocordectomy was performed in all 22 horses; bilateral ventriculocordectomy (right ventriculocordectomy was done 1 year later) was performed in 1 horse (5%). Complications occurred in 3 (14%) horses. Twenty (91%) horses returned to their intended use. Excessive airway noise was eliminated after surgery in 18 (82%) horses; exercise intolerance improved postoperatively in 8 of 10 horses. Three racing Thoroughbreds returned to racing; 1 additional racehorse returned to racing but required a laryngoplasty 1 year later to continue racing. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that LAVC was an effective procedure for elimination of excessive airway noise and improvement of performance in horses with left laryngeal hemiplegia.  相似文献   

20.
OBJECTIVE: To compare racing performance before and after prosthetic laryngoplasty for treatment of laryngeal neuropathy in inexperienced and experienced Thoroughbred racehorses. DESIGN: Retrospective study. ANIMALS: 52 Thoroughbred racehorses treated with prosthetic laryngoplasty for laryngeal neuropathy. PROCEDURE: Lifetime race records were analyzed by use of a verified regression model. Individual race records and hospital records were also reviewed. RESULTS: Experienced horses had a decline in performance, as measured by performance index, earnings percentage, and mean prediction error, during the 6-month period before prosthetic laryngoplasty. Performance improved after surgery, relative to performance in 1 to 4 races immediately before surgery, but did not attain previous baseline values for performance index and earnings percentage, although racing speed was restored to baseline values. Factors associated with failure to attain baseline levels of performance included other racing-related injuries and disorders, major complications of surgery, and age. Individually, however, many horses had long and successful careers after surgery. Performance of inexperienced horses after surgery was at least equal to that of experienced horses. CONCLUSIONS AND CLINICAL RELEVANCE: In addition to warning clients of the complications associated with prosthetic laryngoplasty, it may be prudent to provide a guarded prognosis for full restoration of racing performance in older horses, unless they are especially talented and are free of other racing-related problems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号