首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aim of the present study was to fill the void in data related to hematological and biochemical parameters of donkey foals. Whole-blood and plasma samples were obtained from 16 Amiata donkey foals at birth, at 24 and 48 hours, and at 1, 2, 3, 4, 6, and 8 weeks of age. RBC, WBC, hemoglobin concentration (Hgb), mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, platelet count, glucose, creatinine, blood urea, triglycerides, total cholesterol, total bilirubin, aspartate aminotransferase, γ-glutamyl transferase, creatine-phosphokinase, alkaline phosphatase, total calcium, potassium, sodium, phosphorus, and albumin were measured. Similar to equine foals, values of RBC, Hgb, and Hct decreased significantly after the first 48 hours of life in Amiata donkey foals, reaching values similar to adult donkeys. No changes were found for mean corpuscular volume and mean corpuscular hemoglobin concentration during the study period. The WBC was low at birth when compared with subsequent measurements, but significantly increased in the subsequent surveys. Platelet count was lower in the first week, with a secondary peak 2 weeks later, and then a decline again up to the eighth week. In agreement with equine foals, electrolyte concentrations, triglycerides, and total cholesterol did not show significant differences. Creatinine, total bilirubin, and blood urea showed a trend similar to RBC, Hgb, and Hct. For the first time, data of hematological and biochemical parameters in Amiata donkey foals are provided.  相似文献   

2.
试验对海拔 3 0 0 0m的藏南谷地林芝引入家兔进行了部分生理指标的对比分析。测定了呼吸频率、心率、生理体温、血清蛋白质含量和血红蛋白含量。统计分析表明 :所测定项目的结果在 3品种兔之间均无明显差异 (P >0 0 5) ;但血红蛋白电泳分析 :3品种兔均呈现出A、A2 ,A33个区带 ,发现A3带以青紫兰兔最低 ,与其他 2品种兔差异极显著 (P <0 0 1 ) ;加里福尼亚兔A3带最高 ,显著高于中国白兔 (P <0 0 5)及青紫兰兔 (P <0 0 1 )。血清蛋白质电泳分析表明 :高原家兔的血清白蛋白均明显高于文献报道的低海拔饲养的新西兰白兔 ,血清总蛋白及其球蛋白含量明显下降  相似文献   

3.
BACKGROUND: The ADVIA 120 is an automated laser cell counter widely used in veterinary medicine. Although specific software for equine samples is available and validated, only a few reports have been published comparing the ADVIA 120 with other methods for equine hemogram evaluation. OBJECTIVES: The purpose of this study was to compare the hematologic values and reference intervals obtained on the ADVIA 120 with those obtained on an impedance cell counter and manual differential counts in healthy horses. METHODS: EDTA-anticoagulated blood samples were obtained from 114 clinically healthy horses of various breeds, both sexes, and 2-6 years of age. Samples were stored for up to 12 hours at 4 degrees C and then analyzed on the ADVIA 120 and the Hemat 8. A 100-cell to 200-cell differential leukocyte count was performed by 3 independent observers on May-Grünwald-Giemsa-stained smears. Intra-assay precision of the ADVIA 120 was determined by analyzing 5 replicates each of 10 of the blood samples. RESULTS: Results from the ADVIA were significantly higher than those from the impedance counter for RBC count, total WBC count, hemoglobin concentration, red cell distribution width, MCH, and MCHC, and significantly lower for HCT and platelet count. Significantly higher neutrophil and basophil counts and significantly lower lymphocyte counts were obtained with the ADVIA 120 compared with manual counts. Based on Passing-Bablok regression analysis, RBC and platelet counts were in good agreement between the 2 analyzers; a constant and proportional bias was present for other values. Coefficients of variation for erythrocyte parameters on the ADVIA were <1%, but were higher for platelet (6%), total WBC (2%), differential WBC (4%-30%), and reticulocyte (75%) counts. CONCLUSIONS: Results obtained with equine samples on the ADVIA 120 were comparable with those obtained on an impedance counter; reference intervals differed statistically but overlapped. The ADVIA had poor precision for reticulocyte and differential leukocyte counts such that the latter should always be verified on smears.  相似文献   

4.
果寡糖对固始鸡血液生理指标的影响   总被引:3,自引:0,他引:3  
本试验旨在研究不同添加剂量的果寡糖对固始鸡血液生理指标的影响,并确定果寡糖的最佳添加剂量。选用1日龄固始鸡公雏150只,随机分成5个处理组,1个为对照组,其余4个为试验组,对照组不加果寡糖,其他4个组的果寡糖添加水平分别为3、5、7mg/kg和9mg/kg。测定红细胞压积(PCV)、血红蛋白(Hb)含量、红细胞数量、白细胞数量、平均红细胞体积(MCV)、平均红细胞血红蛋白含量(MCH)和平均红细胞血红蛋白浓度(MCHC)等指标。试验结果表明:1)21和42日龄时,果寡糖试验组的红细胞压积、血红蛋白含量、红细胞数量和白细胞数量均显著高于对照组(P<0.05);与对照组相比,试验组的MCH和MCHC均略有升高,并且可以显著提高MCHC(P<0.05);2)日粮中添加5mg/kg果寡糖对提高红细胞压积、血红蛋白含量、红细胞数量、白细胞数量、MCH和MCHC具有最佳效果。  相似文献   

5.
Blood samples were taken from 78 wild and 21 farmed sika deer (Cervus nippon yesoensis) using ketamine-xylazine sedation during their excited (82 deer) and resting (17 deer) states. Red cell count (RBC), hemoglobin (Hb), packed cell volume (PCV) and mean corpuscular volume (MCV) were significantly higher and mean corpuscular hemoglobin concentration (MCHC) was lower in excited deer than in resting deer. There was no significant difference in total leukocyte count (WBC) between excited and resting wild males, while a marked increase of WBC with neutrophilia was observed in excited wild females. RBC and PCV were significantly higher and MCH was lower in excited males than in excited females. In wild deer, WBC was significantly higher in females than in males, but there was no significant difference in WBC between farmed males and females. Sex differences in the hematological parameters were not observed in fawns (10 months).  相似文献   

6.
Hematologic and rheologic changes were examined in 49 Thoroughbreds before and after competitive racing. Mean postrace values for RBC count, hemoglobin concentration, and PCV increased by 58 to 61%, whereas blood viscosity increased 2 to 3 times. Postrace echinocyte numbers were 162% greater than prerace values. Smaller, but statistically significant, changes were found for mean corpuscular hemoglobin concentration, red cell distribution width, plasma total protein concentration, total WBC count, neutrophil count, and lymphocyte count. Variables measured did not predict whether a horse was a bleeder not treated with furosemide, a bleeder treated with furosemide, or a nonbleeder.  相似文献   

7.
BACKGROUND: The CA530-VET is a completely automated impedance cell hematology analyzer, which yields a 16-parameter blood count including a 3-part leukocyte differential. OBJECTIVES: The aim of this study was to examine the operational potential of the CA530-VET and its value for use in veterinary practice. METHODS: The analyzer was tested for blood carry-over, precision, and accuracy. Comparison methods included the CELL-DYN 3500, microhematocrit centrifugation, manual platelet (PLT) counting for feline and equine species, and a 100-cell manual WBC differential. Blood samples for comparison of the methods were obtained from 242 dogs, 166 cats, and 144 horses. RESULTS: The carry-over ratio (K) was 0.28% for RBC, 0.59% for PLT, 0.32% for WBC, and 0.18% for hemoglobin (HGB) concentration. Coefficients of variation (CVs) for within-batch precision and duplicate measurement of blood samples were clearly within the required limits, except for duplicate platelet counts in cats (8.7%) and horses (9.5%). The WBC count was in excellent agreement for dogs and horses and RBC count was in excellent agreement for horses. The accuracy of feline WBC counts was not acceptable, with the exception of values at the high end of the range. RBC counts in dogs and cats, and HGB concentration and MCV in all 3 species were sufficiently accurate. The CA530-VET HCT results were in excellent agreement with microhematocrit results in horses but exceeded the maximum allowed inaccuracy for cats and dogs. In all species, PLT counts established mechanically and manually were not in adequate agreement. Large differences were found between the CA530-VET and the manual differential percentage for lymphocytes and "mid-sized cells" (monocytes and basophilic granulocytes). CONCLUSIONS: The CA530-VET can be considered useful for routine canine, feline, and equine blood cell analyses. It should not be considered accurate, however, for PLT counts, feline total WBC counts in the subnormal and normal range, and leukocyte differentials, except for granulocytes.  相似文献   

8.
Olive flounder, Paralichythys olivaceus fed with pomegranate enriched diet and challenged with or without Philasterides dicentrarchi had a significantly higher white blood cell (WBC) count on weeks 2 and 4 than the infected group fed with non enriched diet (standard diet). Similarly the red blood cell (RBC) counts did not significantly change in control and treated fish on weeks 1 and 2. It was significantly increased in treated fish on week 2 when compared to the control. In both the groups the hemoglobin (Hb) and hematocrit (Ht) levels significantly increased on weeks 2 and 4. The mean corpuscular volume (MCV) did not significantly change at any time in both groups whereas mean corpuscular hemoglobin (MCH) and mean corpuscular hemoglobin concentration (MCHC) increased significantly on week 4 in the treated group. The leukocytes such as lymphocytes (Lym), monocytes (Mon), neutrophils (Neu), and biochemical parameters such as total protein (TP), glucose (GLU), and calcium (CAL) levels significantly increased in treated groups on week 2 or 4 as compared to the control. The scuticocidal activity and respiratory burst activity were significantly enhanced in treated groups with or without parasite on weeks 2-4. However, the serum lysozyme activity was significantly enhanced from weeks 1 to 4. The protective response in terms of cumulative mortality was low in groups fed with enriched diet against parasite when compared to control. Therefore, we suggest that pomegranate enriched diet following challenge with P. dicentrarchi restores the altered hematological and biochemical parameters, and improves the innate immune system in olive flounder against P. dicentrarchi.  相似文献   

9.
Possible alterations in the erythrogram and in red blood cell volume indices were studied in ten Andalusian stallions subjected to two different types of exercise (trotting and galloping). For this purpose, the changes in these blood parameters were measured during resting, immediately after the exercise finished, and at 5, 10 and 30 min. of recovery.From the results it was deduced that the red blood cell count (RBC), the hematocrit value (PCV) and the concentration of hemoglobin (HB) increased significantly (p≤0.05) after finishing both types of exercise, with a greater increase with galloping. The return to baseline values was faster for trotting than for galloping. However, the RBC volume indices (mean corpuscular volume, mean corpuscular hemoglobin and mean corpuscular hemoglobin concentration) did not undergo any significant changes with either type of exercise.  相似文献   

10.
The purpose of this study was to test the hypothesis that age and sex significantly modulate the changes in hematological parameters of physiologically healthy Spanish Purebred horse, establishing the reference values. Blood samples were obtained on a total of 159 horses (n = 77 males and n = 82 females), classified in four age groups: group A (1–2 years; n = 39), group B (>2–3 years; n = 38), group C (>3–4 years; n = 41), and group D (>4–7 years; n = 41). By means ADVIA 2020i, red blood cell (RBC), hemoglobin concentration (HB), packed cell volume, mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration, platelets (PLTs), as well as total and differential white blood cells (WBCs) were determined. Total plasma protein was determined by spectrophotometry. Results obtained showed that sex had a limited influence on these parameters, being the HB higher in males and WBC higher in females (P = .047). Age caused a reduction in RBC, with a compensatory increase of MCV and MCH, decrease in WBC, PLT, lymphocytes (LYMPs), as well as an increase of N/L ratio (P = .047). Interactions between age and sex showed higher RBC in males than in females of the group B, and higher HB and WBC in males than in females of the group D. According to hematological data, Spanish Purebred horse was classified as a warm- or cold-blooded horse. Decline of RBC, WBC, and PLT parameters is a natural condition of horse with the advance of age, indicating a decrease of the narrow bone response.  相似文献   

11.
The analytic precision of an automated blood analyzer, the Technicon H*1(R), was evaluated utilizing blood samples collected from 20 piglets at 1 and 14 days of age. The effect of storing the blood samples at 4 degrees C for 24 and 48 hours also was determined. Blood samples were analyzed twice on the first day and once on each of the subsequent tow days. Within-sample coefficient of variation was approximately 1% for hemoglobin concentration, erythrocyte count, hematocrit, mean cell volume, erythrocyte distribution width and hemoglobin distribution width (HDW); and approximately 5% for total leukocyte (WBC), neutrophils and lymphocyte counts. Mean HDW and automated differential WBC counts changed during storage to a degree that could be of clinical importance. Manual determination of differential WBC counts were compared with those obtained from the automated analyzer. Results correlated well for neutrophils (r=0.92 in 1-day-old and r=0.93 in 14-day-old piglets, P<0.001) and lymphocytes (r=0.85 in 1-day-old and r=0.93 in 14-day-old piglets, P<0.001). Other WBC values were too low to compare reasonably.  相似文献   

12.
This study evaluated the variation in the prevalence of endoparasitoses and their impact on body condition and blood values of sheep of the Morada Nova breed. A total of 138 ewes were examined for their morphology (body weight, BW; body condition score, BCS), parasitology (faecal egg count, FEC; Famacha© score; coproculture), hematology (red blood cell count,RBC); hemoglobin concentration, HE; packet cell volume, PCV; mean corpuscular volume, MCV,; mean corpuscular hemoglobin, MCH; mean corpuscular hemoglobin concentration, MCHC; leukocytes, WBC) and serum biochemistry (glucose, cholesterol, triglycerides, urea, creatinine, total protein, albumin, globulin, AST and ALT). Overall the animals presented higher BW and BCS in the months of September and December, however, with high FEC, in addition to a large number of animals with Famacha score 4 and 5. The results showed that the main hematophagous worm affecting the sheep, the genus Haemonchus ssp, appeared in a greater proportion (30–71.66%) than the other worms in all months of the study, except in March. About 30% of the hematological values found in the study are outside the reference ranges for suable sheep e 45.50% for serum biochemistry. These findings demonstrate the most healthy period of the year was from March to June for endoparasites control, however, in the months of September and December the animals showed better performance measures.  相似文献   

13.
OBJECTIVE: To evaluate the clinical and histologic effects of repeated intraosseous (IO) needle placement in domestic pigs and determine whether blood and serum obtained intraosseously could be used for CBC and biochemical analyses. ANIMALS: 5 healthy 10-week-old pigs. PROCEDURE: An IO needle was placed in the proximomedial region of the tibia of anesthetized pigs every other week for 2 months, and IO blood was obtained for CBC and serum biochemical analyses. Results were compared with those obtained for blood collected at the same time from the auricular vein. Two weeks after the final samples were obtained, pigs were euthanatized and tibias were processed for histologic examination. RESULTS: Clinical abnormalities, including lameness, were not detected following IO needle placement. Histologic examination revealed only mild multifocal periosteal fibrosis and slight thickening of the periosteum without evidence of osteomyelitis. Chloride, creatinine, glucose, total protein, sodium, and BUN concentrations, alanine transaminase and gamma glutamyl transpeptidase activities, RBC count, mean corpuscular volume, and Hct did not significantly differ between IO and venous samples. However, aspartate transaminase activity, potassium, hemoglobin, and mean corpuscular hemoglobin concentrations, mean corpuscular hemoglobin, and platelet and WBC counts were significantly different. CONCLUSION AND CLINICAL RELEVANCE: Repeated placement of 10 needles may be a safe and clinically useful method to obtain serial blood samples from domestic pigs, particularly when other vascular sites are not accessible. Intraosseous blood can be used for many of the tests comprising CBC and serum biochemical analyses.  相似文献   

14.
BACKGROUND: Standardized hematologic methods and reference intervals have not been established for cartilaginous fishes (sharks, skates, and rays) despite the large number of animals displayed in zoos and aquariums worldwide. OBJECTIVE: The focus of this study was to validate CBC methods for sandbar shark (Carcharhinus plumbeus) blood, based on criteria established in human medicine, for the following tests: RBC count, total WBC count, PCV, hemoglobin (Hgb) concentration, and WBC differential percentages. METHODS: Replicate CBCs were performed using blood samples from 5 captive sandbar sharks. Three protocols for RBC and total WBC counts were compared, as were different centrifugation times for PCV determination, and 2 methods for Hgb concentration. Means, minimum and maximum values, and CVs were compared to CAP and CLIA performance guidelines for human tests. RESULTS: Total WBC counts in a diluent modified for elasmobranch blood, Hgb concentration by the cyanmethemoglobin method after removal of nuclei, and WBC differential percentages showed acceptable performance. PCV results were acceptable when tubes were centrifuged for at least 5 minutes. Total RBC counts by all 3 methods exceeded the acceptable error for manual counts of human cells. CONCLUSIONS: Standardized CBC tests can be used as health assessment tools for elasmobranchs. Total RBC counts should be viewed as estimates.  相似文献   

15.
BACKGROUND: Conventional techniques for canine cerebrospinal fluid (CSF) analysis require large sample volumes and are labor intensive and subject to operator variability. Objective: The purpose of this study was to evaluate the ADVIA120 CSF assay for analysis of canine CSF samples. METHODS: CSF samples collected from 36 healthy control dogs and 17 dogs with neurologic disease were processed in parallel using the automated assay and established manual methods using a hemocytometer and cytocentrifugation. Results for WBC (total nucleated cell) count, RBC count, and differential nucleated cell percentages were compared using Spearman rank correlation coefficients and Bland-Altman bias plots. RESULTS: Correlation coefficients for WBC and RBC counts were 0.57 and 0.83 for controls, and 0.92 and 0.94 for ill dogs, respectively. Coefficients for the percentages of neutrophils, lymphocytes, and monocytes were 0.53, 0.26, and 0.12 for controls and 0.77, 0.92, and 0.70 for dogs with neurologic disease. When data were combined (n=53), correlation coefficients were 0.86 and 0.91 for WBC and RBC counts, and 0.63, 0.43, and 0.30 for neutrophil, lymphocyte, and monocyte percentages. A 9.5% positive bias and 7.0% negative bias were obtained for the ADVIA 120 CSF assay for lymphocytes and macrophages in dogs with neurologic disease with Bland-Altman analysis. A 12.2% positive bias was found for lymphocyte percentage in dogs with neurologic disease. CONCLUSIONS: Manual and automated CSF assays had moderate to excellent correlation for WBC and RBC concentrations, but results were more variable for differential cell percentages. The ADVIA assay may be more useful for assessment of canine CSF with adjustment of cell differentiation algorithms.  相似文献   

16.
Peritoneal fluid and blood was collected from 8 healthy adult horses. Four 1-ml aliquots of peritoneal fluid from each horse were then contaminated with 0 ml (normal), 0.05 ml (1 drop), 0.10 ml (2 drops), and 0.20 ml (4 drops) of blood from the same horse. Samples were analyzed for RBC count, nucleated blood cell count, total protein concentration, and nucleated cell differential count. Statistical analysis revealed no significant changes in nucleated cell number, nucleated cell differential, or total protein concentration in peritoneal samples contaminated with blood. The RBC count significantly increased with blood contamination. It was concluded that up to 17% blood contamination of peritoneal fluid in clinically normal horses did not significantly alter interpretation of the nucleated cell count or protein concentration.  相似文献   

17.
Mercury (Hg) exists in various chemical forms, and it is different to health effects. The most toxic effects occur in the central nervous system during fetal development with irreversible alterations of the nerve cells of the cerebral cortex and, it is essential to monitor the tissue residues of Hg to protect the animal’s health. The present investigation was carried out during May 2019 in 20 horses located in equine sport center near the area of Milazzo, Messina, that is a part of Sicilian territory heavily polluted by many toxic substances. The purpose of this study was to determine the concentration of Hg in blood, serum, food, and water administered to horses and from the hematological profile as a biomarker of blood in relation to the bioaccumulation of Hg. The hematologic parameters (red blood cell, white blood cell, hemoglobin concentration, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, and platelets) were processed with an automated hematology analyzer, and Hg concentrations were determined by DMA-80. To carry out the variation in the Hg levels in serum and blood, the data were subjected to paired t-test analysis; post-hoc comparisons were performed using Tukey’s test. The differences were considered statistically significant when P < .05. Paired t-test showed that in blood samples, Hg concentrations were significantly higher than the serum, and blood samples were positively correlated with serum (r = 0.99; P < .0001). The Hg contents determined in blood, serum, hay, and water samples were below the respective benchmarks, and therefore, we can exclude any toxicological risk for athletic horse.  相似文献   

18.
日粮添加免疫生长促进剂C96对雏鸡若干血液指标的影响   总被引:1,自引:0,他引:1  
选择120只1日龄AA商品健康雏鸡,随机分为4组,每组30只。初步观察了日粮添加免疫生长促进剂C96对血液中红细胞总数(RBC)、比容(PCV)、血红蛋白含量(Hb)、网织红细胞比例(RCC)、白细胞总数(WBC)等的影响。结果表明:肉雏鸡在15d时,日粮添加C96为11mg/kg,饲料的C96组和疫苗-C96组,与对照组和疫苗组比较,RBC和Hb增高,WBC显著下降,RCC降低,PCV无明显规律性变化;30d和45d时,添加C96组和疫苗-C96组的RBC、Hb和PCV,与对照组和疫苗组基本相近,WBC和RCC均比对照组和疫苗组低或明显低。但30d时疫苗组的WBC比对照组高。整个试验期,RBC、WBC和PCV随日龄的增长呈上升趋势,RCC呈波动性下降。  相似文献   

19.
高致病性猪蓝耳病血液常规研究   总被引:1,自引:0,他引:1  
为了解高致病性猪蓝耳病(PRRS)患猪的血液生理指标,给临床防制提供理论依据,试验将健康仔猪和经实验室诊断为PRRS阳性的仔猪各6头,前腔静脉采血,EDTA抗凝管抗凝,用CA500全自动血液分析仪进行血液生理指标分析。结果:(1)PRRS组的白细胞总数、淋巴细胞显著增加(P0.05),单核细胞数量极显著降低(P0.01);(2)PRRS组平均红细胞血红蛋白和平均红细胞体积分布宽度变异系数显著(P0.05)或极显著(P0.01)降低;(3)PRRS组血小板计数、血小板压积、平均血小板体积显著(P0.05)或极显著(P0.01)增加。结果显示:PRRS病毒导致了机体的炎症反应,血管通透性增加,并激活了机体的凝血系统。  相似文献   

20.
OBJECTIVE: To examine total protein concentration and cell counts of sequentially collected samples of CSF to determine whether blood contamination decreases in subsequent samples and whether formulas used to correct nucleated cell count and total protein concentration are accurate. DESIGN: Case series. ANIMALS: 22 horses. PROCEDURE: For each horse, 3 or 4 sequential 2-ml samples of CSF were collected from the subarachnoid space in the lumbosacral region into separate syringes, and blood was obtained from the jugular vein. Total protein concentration, nucleated cell count, and RBC counts were determined in all samples. RESULTS: Among 3 sequential samples, total protein concentration and RBC count were significantly lower in samples 2 and 3, compared with sample 1. Nucleated cell count was significantly lower in sample 3, compared with sample 1. Among 4 sequential samples, total protein concentration and RBC count were significantly lower in samples 2, 3, and 4, compared with sample 1. Nucleated cell count was significantly lower in samples 3 and 4, compared with sample 1. For 3 correction formulas, significant differences in corrected values for nucleated cell count and total protein concentration were detected between sample 1 and sample 3 or 4. CONCLUSIONS AND CLINICAL RELEVANCE: Because iatrogenic blood contamination decreases in sequential CSF samples, a minimum of 3 samples should be collected before submitting the final sample for analysis. Formulas to correct nucleated cell count and total protein concentration are inaccurate and should not be used to correct for blood contamination in CSF samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号