首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
Our goal was to develop and validate a technique to identify the sentinel lymph nodes of the mammary glands of healthy dogs with contrast‐enhanced ultrasound, and evaluate the feasibility of obtaining representative samples of a sentinel lymph node under ultrasound guidance using a new biopsy device. Three healthy intact female adult hounds were anesthetized and each received an injection of octafluoropropane‐filled lipid microspheres and a separate subcutaneous injection of methylene blue dye around a mammary gland. Ultrasound was then used to follow the contrast agent through the lymphatic channel to the sentinel lymph node. Lymph node biopsy was performed under ultrasound guidance, followed by an excisional biopsy of the lymph nodes and a regional mastectomy procedure. Excised tissues were submitted for histopathologic examination and evaluated as to whether they were representative of the node. The ultrasound contrast agent was easily visualized with ultrasound leading up to the sentinel lymph nodes. Eight normal lymph nodes (two inguinal, one axillary in two dogs; two inguinal in one dog) were identified and biopsied. Lymphoid tissue was obtained from all biopsy specimens. Samples from four of eight lymph nodes contained both cortical and medullary lymphoid tissue. Contrast‐enhanced ultrasound can be successfully used to image and guide minimally invasive biopsy of the normal sentinel lymph nodes draining the mammary glands in healthy dogs. Further work is needed to evaluate whether this technique may be applicable in patients with breast cancer or other conditions warranting evaluation of sentinel lymph nodes in animals.  相似文献   

2.
Four dogs with an accessory spleen are described. The accessory spleens appeared as a round‐to‐triangular structure located in the perisplenic area. They were homogeneous and isoechoic with the adjacent spleen. Contrast‐enhanced ultrasound was performed using a second generation microbubble contrast medium (sulfur hexafluoride). The type and timing of enhancement of the accessory spleen was similar to that of the parent spleen. Contrast‐enhanced ultrasound is a noninvasive modality useful in distinguishing an accessory spleen from a mass of another origin.  相似文献   

3.
Pancreatitis is the most frequent disease affecting the exocrine pancreas in dogs and reliable diagnostic techniques for predicting fatal complications are lacking. Contrast‐enhanced ultrasound (CEUS) improves detection of tissue perfusion as well as organ lesion vascular pattern. Objectives of this prospective case control study were to compare perfusion characteristics and enhancement patterns of the pancreas in healthy dogs and dogs with pancreatitis using CEUS. Ten healthy dogs and eight dogs with pancreatitis were selected based on physical examination, abdominal ultrasound, and blood analysis findings. A CEUS study of the pancreas was performed for each dog and two observers who were aware of clinical status used advanced ultrasound quantification software to analyze time‐intensity curves. Perfusion patterns were compared between healthy and affected dogs. In dogs with acute pancreatitis, mean pixel and peak intensity of the pancreatic parenchyma was significantly higher than that of normal dogs (P = 0.05) in between 6 and 60 s (P = <0.0001–0.046). This corresponds to a 311% increase in mean pixel intensity in dogs with acute pancreatitis compared to healthy dogs. Wash‐in rates were greater and had a consistently steeper slope to peak in dogs with pancreatitis as opposed to healthy dogs. All dogs with pancreatitis showed a decrease in pixel intensity 10–15 days after the initial examination (P = 0.011) and their times to peak values were prolonged compared to the initial exam. Findings from the current study supported the use of CEUS for diagnosing pancreatitis, pancreatic necrosis, and disease monitoring following therapy in dogs.  相似文献   

4.
Canine prostate gland abnormalities affect a large number of adult male dogs. In veterinary medicine, the commonly used methods to diagnose canine prostate gland disease are digital rectal examination and abdominal ultrasound. We evaluated the ability of ultrasound contrast agent to provide additional information about the vascularity of the canine prostate gland; such information could be useful in detecting early prostate gland disease and in staging disease known to be present. We characterized the ultrasonographic appearance of prostate gland vascularity in 10 healthy dogs before and after the injection of an ultrasound contrast agent (Levovist?). Before injecting Levovist?, the prostate gland blood flow was classified as poor in all dogs, whereas after contrast agent injection blood flow was classified as moderate or good, in 3 and 7 dogs respectively. Knowledge of the status of prostate gland vascularity could be useful for the characterization, diagnosis and therapeutic monitoring of canine prostate gland lesions.  相似文献   

5.
Contrast‐enhanced ultrasound of the spleen enables the dynamic assessment of the perfusion of this organ, however, both subjective and quantitative evaluation can be strongly influenced by sedative agent administration. The purpose of this prospective, experimental study was to test effects of two sedative agents on splenic perfusion during contrast‐enhanced ultrasound of the spleen in a sample of healthy dogs. Contrast‐enhanced ultrasound of the spleen was repeated in six healthy Beagles following a cross‐over study design comparing three protocols: awake, butorphanol 0.2 mg/Kg intramuscular (IM), and dexmedetomidine 500 μg/m2 IM. After intravenous injection of a phospholipid stabilized sulfur hexafluoride microbubble solution (SonoVue®, Bracco Imaging, Milano, Italy), the enhancement intensity and perfusion pattern of the splenic parenchyma were assessed and perfusion parameters were calculated. Normal spleen was slightly heterogeneous in the early phase, but the parenchyma was homogeneous at a later phase. Sedation with butorphanol did not modify perfusion of the spleen. Dexmedetomidine significantly reduced splenic enhancement, providing diffuse parenchymal hypoechogenicity during the entire examination. Measured parameters were significantly modified, with increased arrival time (AT; (< 0.0001) and time to peak (TTP; P < 0.0001), and decreased peak intensity (PI; P = 0.0108), wash‐in (P = 0.0014), and area under the curve (AUC; P = 0.0421). Findings supported the use of butorphanol and contraindicated the use of dexmedetomidine as sedatives for splenic contrast ultrasound procedures in dogs. Short‐term and diffuse heterogeneity of the spleen in the early venous phase was determined to be a normal finding.  相似文献   

6.
We characterized the pattern of ultrasonographic contrast enhancement of the small intestinal wall using a commercial contrast medium (Sonovue®) in 10 healthy awake cats. Subjectively, a rapid intense enhancement of the serosal and submucosal layers was followed by gradual enhancement of the entire wall section during the early phase. At peak enhancement, there was a subjective loss of demarcation between intestinal wall layers. In the late phase, there was a gradual wash out of signal from the intestinal wall. Submucosal wash out occurred last. Time‐intensity curves were generated for selected regions in the intestinal wall and multiple perfusion parameters were calculated for each cat. Perfusion parameters included arrival time (7.64 ± 2.23 s), baseline intensity (1.04 ± 0.04 a.u.), time to peak from injection (10.74 ± 2.08 s), time to peak from initial rise (3.1 ± 1.15), peak intensity (8.92 ± 3.72 a.u.), wash‐in rate (2.06 ± 0.70 a.u./s) and wash‐out rate (?1.07 ± 0.91 a.u./s). The perfusion pattern of normal feline small bowel may be useful for characterizing feline gastrointestinal disorders that involve the intestinal wall.  相似文献   

7.
Contrast‐enhanced ultrasonography is useful in differentiating adrenal gland adenomas from nonadenomatous lesions in human patients. The purposes of this study were to evaluate the feasibility and to describe contrast‐enhanced ultrasonography of the normal canine adrenal gland. Six healthy female Beagles were injected with an intravenous bolus of a lipid‐shelled contrast agent (SonoVue®). The aorta enhanced immediately followed by the renal artery and then the adrenal gland. Adrenal gland enhancement was uniform, centrifugal, and rapid from the medulla to the cortex. When maximum enhancement was reached, a gradual homogeneous decrease in echogenicity of the adrenal gland began and simultaneously enhancement of the phrenicoabdominal vessels was observed. While enhancement kept decreasing in the adrenal parenchyma, the renal vein, caudal vena cava, and phrenicoabdominal vein were characterized by persistent enhancement until the end of the study. A second contrast enhancement was observed, corresponding to the refilling time. Objective measurements were performed storing the images for off‐line image analysis using Image J (ImageJ©). The shape of the time–intensity curve reflecting adrenal perfusion was similar in all dogs. Ratios of the values of the cortex and the medulla to the values of the renal artery were characterized by significant differences from initial upslope to the peak allowing differentiation between the cortex and the medulla for both adrenal glands only in this time period. Contrast‐enhanced ultrasonography of the adrenal glands is feasible in dogs and the optimal time for adrenal imaging is between 5 and 90 s after injection.  相似文献   

8.
9.
Abdominal ultrasonography is one of the most common diagnostic imaging modalities used for dogs with suspected insulinoma; however, pancreatic masses are clearly identified in fewer than half of affected dogs and benign pancreatic nodules can be difficult to differentiate from malignant ones. The purpose of this prospective study was to describe contrast‐enhanced ultrasonography (CEUS) characteristics of confirmed pancreatic insulinoma in a group of dogs. Inclusion criteria were as follows: (1) repeated hypoglycemia (blood glucose levels <60 mg/dl, twice or more); (2) elevated blood insulin levels with hypoglycemia; (3) pancreatic nodules detected with conventional ultrasonography; and (4) histological confirmation of pancreatic islet cell carcinoma. Immediately following conventional ultrasonography of the entire abdomen, CEUS of the pancreatic nodule and adjacent parenchyma was performed using contrast‐specific technology pulse inversion imaging and perflubutane microbubble contrast agent. Three dogs met inclusion criteria. Pancreatic nodules in all the three dogs became more clearly demarcated after injection of the contrast agent. Each nodule showed different enhancement patterns: markedly hyperechoic for 5 s, slightly hyperechoic for 1 s, and clearly hypoechoic for over 30 s. These results were not in complete agreement with previously reported CEUS findings in human patients with insulinoma. All nodules were surgically resected and histopathologically confirmed as malignant insulinomas. Findings from the current study indicated that contrast‐enhanced ultrasound may help to increase conspicuity of pancreatic insulinomas in dogs and that enhancement characteristics may be more variable in dogs than in humans.  相似文献   

10.
Desmitis of the collateral ligament of the distal interphalangeal joint is a cause of lameness in performance horses. The objective of this prospective, experimental, ex vivo feasibility study was to evaluate the success of ultrasound‐guided injection of the collateral ligaments of the distal interphalangeal joint in the equine forelimb. Seventy‐six ultrasound‐guided dye injections of the collateral ligament of the distal interphalangeal joint were performed on horses’ cadaver limbs. The hooves were sectioned transversely to verify the location of the dye relative to the collateral ligaments and surrounding structures. Evaluations of transverse sections were performed independently by two experienced observers. A scoring system was used to assess injection of the collateral ligament of the distal interphalangeal joint at the proximal, middle, and distal aspect over the length of the ligament. The collateral ligament was injected at any point in 97.4% of cases. The ligament was injected over the entire scored length in 43.2% of cases (32/74), over two scored length areas in 45.9% of cases (34/74), and in one area in 10.8% of cases (8/74). The distal interphalangeal joint and the common digital extensor tendon were also injected in 81.6% (62/76) and 43.4% (33/76) of the cases, respectively. Use of the ultrasound had a positive and negative predictive value of 98% and 9%, respectively. In this study, ultrasound guidance was useful for confirming injection of the collateral ligament of the distal interphalangeal joint but did not prevent injecting the distal interphalangeal joint and the common digital extensor tendon.  相似文献   

11.
In a two-phase study, ultrasound was used to delineate the normal sonographic anatomy of soft tissues of the equine distal limb. The study was limited to the soft tissues of the palmar surface of the limb just proximal to the fetlock joint. In the first phase, cadavers were evaluated with a B-mode ultrasound machine, † Then the limbs were radiographed and dissected to compare their gross, radiographic, and ultrasonographic appearances. In the second phase, nine normal adult horses were ultrasonographically scanned. The sonographic appearance of the normal animals was compared with that of the cadavers. Front and rear limbs of all horses had similar ultrasonographic appearances. Flexor tendons and the suspensory ligament were easily identified as having linear, uniformly intense ecogenicity. The borders of the digital sheath and of the proximal palmar pouch of the fetlock joint had a less organized and less intense ecogenic appearance than the flexor tendons and suspensory ligament, and they were poorly delineated unless distended with fluid. Ultrasonography was used in three lame horses and aided the diagnoses of synovial proliferation in the fetlock joint, tendosynovitis, and bowed tendon. Diagnostic ultrasonography was effective in identifying and characterizing soft-tissue structures of the distal equine limb. It is a valuable, noninvasive diagnostic aid.  相似文献   

12.
Contrast‐enhanced ultrasound offers a noninvasive means of subjectively and quantitatively evaluating renal perfusion in cats with renal disease, or in renal transplant patients. In this study, we characterized the pattern of ultrasonographic contrast enhancement in 16 normal feline kidneys in eight cats using contrast‐enhanced power Doppler and contrast‐enhanced harmonic ultrasound techniques. Mean time to peak contrast enhancement for the whole kidney was longer using contrast‐enhanced harmonic ultrasound (16.8s, SD 4.7s) than contrast‐enhanced power Doppler ultrasound (12.2s, SD 1.8s). The time to peak enhancement for the cortex alone in contrast‐enhanced harmonic ultrasound was 13s (SD 3.2s), and for the renal medulla was 25.5s (SD 8.7s). The half time for washout of contrast agent was 39s (SD 14.5s) for contrast‐enhanced harmonic ultrasound. The pattern of contrast enhancement in these normal feline kidneys can be used as normal reference values for the evaluation of clinical patients. Contrast‐enhanced harmonic ultrasound may allow the differentiation between cortical and medullary perfusion patterns.  相似文献   

13.
DIAGNOSTIC ULTRASOUND IMAGING OF SOFT TISSUES IN THE BOVINE DISTAL LIMB   总被引:4,自引:0,他引:4  
In this study sonographic images of healthy flexor tendons, digital flexor tendon sheaths, metacarpophalangeal and metatarsophalangeal joints, and proximal and distal interphalangeal joints of the bovine limb were made. Then, synovial cavities in cadavers were filled with the necessary amount of fluid to make the lumina visible sonographically. After injecting 30–40 ml of saline solution into the digital flexor tendon sheath and into the metacarpophalangeal and metatarsophalangeal joints, or 8 ml in the proximal interphalangeal joint and 10 ml in the distal interphalangeal joint, the pouches of these synovial cavities were clearly demarcated. Afterwards, the sonographic image of synovial cavities distended by various inflammatory content were described. When the sonographic findings were compared to the findings in clinical patients, centesis and intraoperative procedures, there appeared to be a relationship as to the extent and location of the disorders as well as to the nature of the synovial effusion. Finally, we identified which planes on diseased bovine distal limbs were appropriate for obtaining optimal sonographic images.  相似文献   

14.
We evaluated dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) in canine brain tumors. Magnetic resonance data sets were collected on seven canine intracranial tumors with a 3 T magnet using a T1‐weighted fast spin echo fluid attenuated inversion recovery sequence after an IV bolus injection (0.2 mmol/kg) of Gd‐DTPA. The tumors were confirmed histopathologically as adenocarcinoma (n=1), ependymoma (n=1), meningioma (n=3), oligodendroglioma (n=1), and pituitary macroadenoma (n=1) The data were analyzed using a two‐compartment pharmacokinetic model for estimation of three enhancement parameters, ER (rate of enhancement), Kel (rate of elimination), and Kep (rate constant), and a model‐free phenomenologic parameter initial area under the Gd concentration curve (IAUGC) defined over the first 90 s postenhancement. Pearson's correlations were calculated between parameters of the two methods. The IAUGC has a relatively strong association with the rate of enhancement ER, with r ranges from 0.4 to 0.9, but it was weakly associated with Kep and Kel. To determine whether any two tumors differed significantly, the Kolmogorov–Smirnov test was used. The results showed that there were statistical differences (P<0.05) between distributions of the enhancement pattern of each tumor. These kinetic parameters may characterize the perfusion and vascular permeability of the tumors and the IAUGC may reflect blood flow, vascular permeability, and the fraction of interstitial space. The kinetic parameters and the IAUGC derived from DCE‐MRI present complementary information and they may be appropriate to noninvasively differentiate canine brain tumors although a larger prospective study is necessary.  相似文献   

15.
Compression elastography is an ultrasonographic technique that estimates tissue strain and may have utility in diagnosing and monitoring soft tissue injuries in the equine athlete. Recently, elastography has been proven to be a feasible and repeatable imaging modality for evaluating normal tendons and ligaments of the equine distal forelimb. The purposes of this prospective study were to investigate the ability of elastography to detect spontaneously occurring lesions of equine tendons and ligaments diagnosed with magnetic resonance imaging (MRI) and gray‐scale ultrasound (US) and to characterize the differences in the elastographic appearance of acute vs. chronic injuries. Fifty seven horses with a total of 65 lesions were evaluated. Images were assessed quantitatively and qualitatively. Acute lesions were found to be significantly softer (P < 0.0001) than chronic lesions (P < 0.0001) and the stiffness of lesions increased with progression of healing (P = 0.0138). A negative correlation between lesion hypoechogenicity and softness was appreciated with more hypoechoic lesions appearing softer (P = 0.0087) and more hyperechoic regions harder (P = 0.0002). A similar finding occurred with increased signal intensity on short tau inversion recovery (STIR) and proton density (PD) MRI sequences correlating with increased softness on elastography (P = 0.0164). Using US and MRI as references, commonly encountered soft tissue injuries of the equine distal limb could be detected with elastography. However, elastography was limited for detecting small, proximal injuries of the hindlimb proximal suspensory ligament. Elastographic evaluation of equine tendons and ligaments may allow better characterization of lesion chronicity and severity, and sequential examinations may optimize lesion management, rehabilitation, and return to training.  相似文献   

16.
Computed tomography angiography, sonography, scintigraphy, and portography can be used to evaluate the portal vasculature to evaluate for a portosystemic shunt (PSS). Time‐of‐flight magnetic resonance angiography (TOF‐MRA) and contrast‐enhanced MRA (CE‐MRA) are other potentially useful techniques. The aim of this study was to evaluate CE‐MRA in 10 dogs suspected of having a PSS. Noncontrast MR images of the abdomen were obtained using a Siemens Symphony MR‐scanner (1.5 T) and a T1‐weighted FLASH‐3D sequence with a very short scan time (about 20 s). After injection of contrast medium, the initial sequence was repeated five times. The sequence with the best contrast medium filling of the portal vasculature was selected subjectively, subtracted from the initial survey image series, and a maximum intensity projection (MIP) of the subtraction data, in multiple views, was created. The cross‐sectional and MIP images were evaluated for abnormal portosystemic vasculature. A single PSS was identified and confirmed at surgery in all dogs. A portocaval shunt was found in five dogs, a portophrenic shunt in three dogs, a portoazygos shunt in one, and a central divisional intrahepatic shunt in one other dog. Based on our results, CE‐MRA is a useful tool for imaging abdominal and portal vasculature and for the diagnosis of a PSS.  相似文献   

17.
Nine normal juvenile dogs were evaluated with direct jejunal contrast‐enhanced ultrasonography via midline celiotomy. Three different doses of ultrasound contrast medium (Definity®) were injected through a peripheral venous catheter. Time‐intensity curves were used to calculate baseline, time to initial rise, inflow slope, time‐to‐peak, peak intensity (PI), and outflow slope for each administered dose. PI was directly proportional to dose. Outflow slope was similar for all patients, independent of dose. The most favorable images were acquired with a dose of 0.030 ml/kg given as a rapid intravenous manual bolus. The technique and normal jejunal perfusion pattern described herein may provide useful data for evaluation of intestinal vascular, inflammatory, and neoplastic disease in the dog.  相似文献   

18.
Ultrasonography of the femoral artery in the horse, including color, power and spectral Doppler, provides morphologic and dynamic information. This paper describes the use of the techniques in six clinically normal horses and three with femoral artery thrombosis. Useful landmarks for orientation are the saphenous artery and the medial saphenous vein. The lateral circumflex femoral artery can not be visualized. Recognition of the genus descendens artery is complicated due to the presence of multiple distal caudal femoral arteries. The femoral artery feeds a high resistance bed. In normal horses the peak systolic velocity varies between 50–90 cm/sec. Echoic tissue in the femoral artery lumen with stenosis, occlusion and collateral blood flow formation are features encountered in the patients.  相似文献   

19.
Contrast‐enhanced ultrasound can be used to quantify tissue perfusion based on region of interest (ROI) analysis. The effect of the location and size of the ROI on the obtained perfusion parameters has been described in phantom, ex vivo and in vivo studies. We assessed the effects of location and size of the ROI on perfusion parameters in the renal cortex of 10 healthy, anesthetized cats using Definity® contrast‐enhanced ultrasound to estimate the importance of the ROI on quantification of tissue perfusion with contrast‐enhanced ultrasound. Three separate sets of ROIs were placed in the renal cortex, varying in location, size or depth. There was a significant inverse association between increased depth or increased size of the ROI and peak intensity (P<0.05). There was no statistically significant difference in the peak intensity between the ROIs placed in a row in the near field cortex. There was no significant difference in the ROIs with regard to arrival time, time to peak intensity and wash‐in rate. When comparing two different ROIs in a patient with focal lesions, such as suspected neoplasia or infarction, the ROIs should always be placed at same depth and be as similar in size as possible.  相似文献   

20.
Distal tarsal pain is a common reason for hind limb lameness, but diagnosis cannot always be made on radiographic examination. Scintigraphy may allow detection of subtle changes undetected by other diagnostic methods. We hypothesized that (1) distal tarsal pain would be associated with a loss of the expected pattern of radiopharmaceutical uptake (RU) detected in normal horses, (2) distal tarsal RU would be greater in limbs with tarsal pain than without pain, (3) RU in painful tarsi with radiographic evidence of osteoarthritis (OA) would be greater than in distal tarsal pain with no radiographic evidence of OA. The study aimed to describe radiopharmaceutical distribution in the distal tarsal region of horses with distal tarsal pain, and to compare this with the contralateral limb and results from horses without tarsal pain. Retrospective evaluation of scintigraphic images of the distal tarsal region was performed for 52 horses with distal tarsal pain: 15 with no radiographic evidence of OA (Group 1) and 37 with radiographic evidence (Group 2). The images were assessed using vertical and horizontal profile analysis across the distal tarsal region and regions of interest comparisons between the distal tarsal region and tibia within each horse (RU ratio). Painful limbs in unilaterally lame horses from Groups 1 and 2 had a significantly greater RU ratio than the respective contralateral limbs, and were significantly greater than the RU ratio in normal horses. On plantar images, mean region of interest counts were greater in the lame than the contralateral limb in Group 2 but not in Group 1. Although there was a positive correlation between lame and contralateral limb RU ratio in group 1, this was lost in group 2 horses. In lame limbs, the normal vertical activity profile was lost in 85% of group 1 and all of group 2, and the normal horizontal activity profile was lost in all of group 1 and 96% of group 2. There was a significant effect of lameness, but not of group on sites of peak activity on all profiles. The results of this study indicate that distal tarsal pain is associated with loss of the expected pattern of RU detected in normal horses. The findings also suggest that distal tarsal RU in lame limbs is greater than in limbs without pain, and that painful limbs with radiographic evidence of OA have a greater RU than painful limbs without radiographic evidence of OA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号