首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 15 毫秒
1.
2.
Objective – To determine if metatarsal artery pressure (COmet) is comparable to femoral artery pressure (COfem) as the input for transpulmonary pulse contour analysis (PiCCO) in anesthetized dogs, using the lithium dilution method (LiDCO) as a standard for cardiac output (CO) measurement. Design – Prospective randomized study. Setting – University research laboratory. Animals – Ten healthy purpose‐bred mixed breed dogs were anesthetized and instrumented to measure direct blood pressure, heart rate, arterial blood gases, and CO. Interventions – The CO was measured using LiDCO and PiCCO techniques. Animals had their right femoral and left distal metatarsal artery catheterized for proximal (COfem) and distal (COmet) PiCCO analysis, respectively. Measurements were obtained from each animal during low, normal, and high CO states by changing amount of inhalant anesthetics and heart rate. Measurements were converted to CO indexed to body weigh (CIBW=CO/kg) for statistical analysis. Agreement was determined using Bland and Altman analysis and concordance correlation coefficients. Measurements and Main Results – Thirty paired measurements were taken. The LiDCO CIBW (± SD) was 68.7 ± 30.3, 176.0 ± 53.0, and 211.1 ± 76.5 mL/kg/min during low, normal, and high CO states, respectively. There was a significant effect of CIBW state on bias and relative bias with COmet (P<0.001 and P=0.003, respectively). Bias of the COmet method (± SD) was ?116.6 (70.5), 20.1(76.4), and 91.3 (92.0) mL/kg/min at low, normal, and high CIBW, respectively. Bias of the COfem (± SD) was ?20.3 (19.0), 8.6 (70.9), and ?2.9 (83.0) mL/kg/min at low, normal, and high CIBW, respectively. The mean relative bias for COfem was ?6.7 ± 44% (limits of agreements: ?81.2 to 67.9%). Conclusion – Compared with lithium dilution, the pulse contour analysis provides a good estimation of CO, but requires femoral artery catheterization in anesthetized dogs.  相似文献   

3.
4.
5.
Objective and hypothesis: To determine whether or not there is agreement between the thermodilution and echocardiographic measurement of cardiac output (CO) during normovolemia and acute hemorrhage. The hypothesis was that there will be agreement between echocardiographic measurement of CO (ECO) and thermodilution measurement of CO (TDCO) during normovolemia and acute hemorrhage. Design: CO was measured by both thermodilution and echocardiography during α‐chloralose anesthesia in dogs before and 15 and 30 minutes following acute arterial hemorrhage. Setting: Laboratory investigation. Animals: Eighteen clinically healthy dogs, weighing 20–25 kg, anesthetized with α‐chloralose. Interventions: Acute arterial hemorrhage of approximately 50% of the total blood volume. CO was measured by thermodilution and echocardiography before and 15 and 30 minutes following hemorrhage. Measurements and main results: Acute hemorrhage resulted in a significant decrease in CO. There was a lack of agreement between the 2 methods to measure CO at each time and at all anatomic points of measurement in the aorta and pulmonary artery. Conclusion: There is a lack of agreement between the 2 methods; thus, determination of CO by echocardiography may not be a clinically useful tool following hemorrhage in dogs.  相似文献   

6.
ObjectiveTo evaluate the accuracy of a new cardiac output monitor (FloTrac/Vigileo), originally designed for humans, in dogs. This pulse contour cardiac output monitoring system cannot be calibrated and measures cardiac output (
t) from a standard arterial catheter.Study designProspective experimental trial.AnimalsEight adult Beagle dogs weighing 13.1 (9.8–17.1) kg [median (range)].MethodsAnaesthesia in the dogs was maintained using isoflurane. A pulmonary artery catheter and a metatarsal arterial catheter (22 gauge) were placed. Cardiac output was measured simultaneously 331 times by thermodilution and FloTrac technique. A broad spectrum of
t measurements was achieved through alterations of isoflurane concentration, administration of propofol boluses and dobutamine infusions. Agreement between the methods was quantified with Bland Altman analysis and disagreement was assessed with linear mixed models.ResultsMedian (10th and 90th percentile) cardiac output as measured with thermodilution was 2.54 (1.47 and 5.15) L minute?1 and as measured with FloTrac 8.6 (3.9 and 17.3) L minute?1. FloTrac measurements were consistently higher with a mean bias of 7 L minute?1 and limits of agreement of ?3.15 to 17.17 L minute?1. Difference between the methods was most pronounced in high
t measurements. Linear mixed models showed an estimated difference between the two methods of 8.05 (standard error 1.18) L minute?1 and a significant interaction between mean arterial pressure and method. Standard deviation (4.45 higher) with the FloTrac method compared to thermodilution was increased.ConclusionCompared to thermodilution measurements, the FloTrac system was influenced to a higher degree by arterial blood pressure, resulting in consistent overestimation of cardiac output.Clinical RelevanceThe FloTrac monitor, whose algorithms were developed based on human data, cannot be used as an alternative for thermodilution in dogs.  相似文献   

7.
ObjectiveTo compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (COTD) and Doppler evaluation of pulmonary flow (CODP) and aortic flow (CODA).Study designProspective cohort study.AnimalsEight adult dogs weighing 8.3 ± 2.0 kg.MethodsPropofol was used for induction (7.5 ± 1.9 mg kg?1 IV) followed by a continuous rate infusion at 0.7 mg kg?1 minute?1. The animals were positioned in left lateral recumbency on an echocardiography table that allowed for positioning of the transducer at the 3rd and 5th intercostal spaces of the left hemithorax for Doppler evaluation of pulmonary and aortic valves, respectively. CODP and CODA were calculated from pulmonary and aortic velocity spectra, respectively. A pulmonary artery catheter was inserted via the jugular vein and positioned inside the lumen of the pulmonary artery in order to evaluate COTD. The first measurement of COTD, CODP and CODA was performed 30 minutes after beginning continuous infusion (T0) and then at 15‐minute intervals (T15, T30, T45 and T60). Numeric data were submitted to two‐way anova for repeated measurements, Pearson’s correlation coefficient and Bland &; Altman analysis. Data are presented as mean ± SD.ResultsAt T0, COTD was lower than CODA. CODA was higher than COTD and CODP at T30, T45 and T60. The difference between the COTD and CODP, when all data were included, was ?0.04 ± 0.22 L minute?1 and Pearson’s correlation coefficient (r) was 0.86. The difference between the COTD and CODA was ?0.87 ± 0.54 L minute?1 and r = 0.69. For COTD and CODP, the difference was ?0.82 ± 0.59 L minute?1 and r = 0.61.ConclusionDoppler evaluation of pulmonary flow was a clinically acceptable method for assessing the CO in propofol‐anesthetized dogs.  相似文献   

8.
9.
ObjectiveTranspulmonary ultrasound dilution (TPUD) is a minimally invasive technique to measure cardiac output (CO) using a 1 mL kg–1 isotonic 37 °C saline injectate indicator. The objective was to evaluate the performance of TPUD using a room temperature saline injectate.Study designProspective experimental trial.AnimalsA total of seven anesthetized male Yorkshire piglets.MethodsPiglets aged 1 month and weighing 7.7–9.0 kg were anesthetized with detomidine–ketamine–hydromorphone–isoflurane and a pulmonary artery flow probe (PAFP) placed via a median sternotomy. The thoracic cavity remained open during measurement of CO by PAFP and TPUD. The TPUD indicators of 1 mL kg–1 0.9% saline at 37 °C and 20 °C were compared during infusions of phenylephrine and dobutamine, blood withdrawal and replacement. Bias, limits of agreement (LoAs) and percentage error (PE) between each iteration of PAFP and TPUD were measured with Bland–Altman plots. Trending ability via concordance, angular bias and radial LoA were compared.ResultsBland–Altman plots showed negligible bias with varying LoAs. PEs of 22% and 38% were found for 37 °C and 20 °C saline injectates, respectively. In the four-quadrant plots, the concordance rate was 94% and 100% for measurements obtained with 37 °C and 20 °C saline injectates, respectively. Angular bias for both were < ±5 °, with radial LoA < ±7 °.ConclusionsTPUD was accurate when using 1 mL kg–1 of isotonic saline at 37 °C in a range of CO within 0.2–0.8 L minute–1, and it reliably tracked positive and negative changes in CO. Room temperature (20 °C) indicator was less accurate but equally able to track direction of changes in CO.Clinical relevanceThe use of room temperature injectates allows an easy, readily available clinical application of TPUD CO monitoring while preserving the trending ability of the monitor.  相似文献   

10.

Objective

To evaluate the ability of pulse wave transit time (PWTT) to detect changes in stroke volume (SV) and to estimate cardiac output (CO) compared with the thermodilution technique in isoflurane-anaesthetized dogs.

Study design

Prospective, experimental study.

Animals

Eight adult laboratory dogs.

Methods

The dogs were anaesthetized with isoflurane and mechanically ventilated. Reference CO (TDCO) was measured via a pulmonary artery catheter using the thermodilution technique and reference SV (TDSV) was calculated. PWTT was calculated as the time from the electrocardiogram R-wave peak to the rise point of the pulse oximeter wave. Estimated CO (esCO) was derived from PWTT after calibration with arterial pulse pressure (both non-invasive and invasive methods) and TDCO. Haemodynamic changes were induced by administration of phenylephrine (vasoconstriction), high isoflurane (vasodilatation and negative inotropy) and dobutamine (vasodilatation and positive inotropy). Trending between percentage change in PWTT and TDSV was assessed using concordance analysis and receiver operator characteristic (ROC) curve. The agreement between esCO and TDCO was evaluated using the Bland–Altman method.

Results

The direction of percentage change between consecutive PWTT and the corresponding TDSV showed a concordance rate of 95%, with correlation coefficients of ?0.86 (p < 0.001). Area under the ROC curve for the change in PWTT to detect 15% change in TDSV was 0.91 (p < 0.001). TDCO compared with esCO calibrated with invasive and non-invasive blood pressure showed a bias (precision of agreement) of 0.58 (1.54) and 0.57 (1.59) L minute?1 with a percentage error of ±61% and ±63%, respectively.

Conclusions and clinical relevance

In isoflurane-anaesthetized dogs, PWTT showed a good trending ability to detect 15% changes in SV. This technique is easy to use, inexpensive, non-invasive and could become routine anaesthetic monitoring. However, the agreement between absolute esCO and TDCO was unacceptable.  相似文献   

11.
12.
13.
Objective – To compare the determination of cardiac output (CO) via arterial pulse pressure waveform analysis (FloTrac/Vigileo) versus lithium dilution method. Design – Prospective study. Setting – University teaching hospital. Animals – Six adult dogs. Interventions – Dogs were instrumented for CO determinations using lithium dilution (LiDCO) and FloTrac/Vigileo methods. Direct blood pressure, heart rate, arterial blood gases, and end‐tidal isoflurane (ETIso) and CO2 concentrations were measured throughout the study while CO was manipulated with different depth of anesthesia and rapid administration of isotonic crystalloids at 60 mL/kg/h. Measurements and Main Results – Baseline CO measurements were obtained at 1.3% ETIso and were lowered by 3% ETIso. Measurements were obtained in duplicate or triplicate with LiDCO and averaged for comparison with corresponding values measured continuously with the FloTrac/Vigileo method. For 30 comparisons between methods, a mean bias of ?100 mL/kg/min and 95% limits of agreement between ?311 and +112 mL/kg/min (212 mL/kg/min) was determined. The mean (mL/kg/min) of the differences of LiDCO?Vigileo=62.0402+?0.8383 × Vigileo, and the correlation coefficient (r) between the 2 methods 0.70 for all CO determinations. The repeatability coefficients for the individual LiDCO and FloTrac/Vigileo methods were 187 and 400 mL/kg/min, respectively. Mean LiDCO and FloTrac/Vigileo values from all measurements were 145 ± 68 mL/kg/min (range, 64–354) and 244 ± 144 mL/kg/min (range, 89–624), respectively. The overall mean relative error was 48 ± 14%. Conclusion – The FloTrac/Vigileo overestimated CO values compared with LiDCO and the relative error was high, which makes this method unreliable for use in dogs.  相似文献   

14.
OBJECTIVE: To assess the suitability of a human algorithm for calculation of continuous cardiac output from the arterial pulse waveform, in anaesthetized horses. STUDY DESIGN: Prospective clinical study. ANIMALS: Twenty-four clinical cases undergoing anaesthesia for various conditions. MATERIALS AND METHODS: Cardiac output (Qt), measured by lithium dilution (QtLiDCO), was compared with a preceding, calibrated Qt measured from the pulse waveform (QtPulse). These comparisons were repeated every 20-30 minutes. Positive inotropes or vasopressors were administered when clinically indicated. Cardiac indices from 30.7 to 114.9 mL kg(-1) minute(-1) were recorded. Unusually shaped QtLiDCO curves were rejected and the measurement was repeated immediately. RESULTS: Eighty-nine comparisons were made between QtLiDCO and QtPulse. The bias between the mean (+/-SD) of the two methods (QtLiDCO - QtPulse) was -0.07 L minute(-1)(+/-3.08) (0.24 +/- 6.48 mL kg(-1) minute(-1)). The limits of agreement were -12.72 and 13.2 mL kg(-1) minute(-1) (Bland & Altman 1986; Mantha et al. 2000). Linear regression analysis demonstrated a correlation coefficient (r2) of 0.89. Cardiac output in individual patients varied from 49.1 to 183% of the initial measurement at the time of calibration. Linear regression of log-transformed Qt variation for each method found a mean difference of 9% with limits of agreement of -4.1 to 22.1%. CONCLUSIONS AND CLINICAL RELEVANCE: This method of pulse contour analysis is a relatively noninvasive and reliable way of monitoring continuous Qt in the horse under anaesthesia. The ability to easily monitor Qt might decrease morbidity and mortality in the anaesthetized horse.  相似文献   

15.

Objective

To compare electrical velocimetry (EV) noninvasive measures of cardiac output (CO) and stroke volume variation (SVV) in dogs undergoing cardiovascular surgery with those obtained with the conventional thermodilution technique using a pulmonary artery catheter.

Study design

Prospective experimental trial.

Animals

Seven adult Beagle dogs with a median weight of 13.6 kg.

Methods

Simultaneous, coupled cardiac index (CI; CO indexed to body surface area) measurements by EV (CIEV) and the reference pulmonary artery catheter thermodilution method (CIPAC) were obtained in seven sevoflurane-anaesthetized, mechanically ventilated dogs undergoing experimental open-chest cardiovascular surgery for isolated right ventricular failure. Relationships between SVV or central venous pressure (CVP) and stroke volume (SV) were analysed to estimate fluid responsiveness. Haemodynamic data were recorded intraoperatively and before and after fluid challenge.

Results

Bland–Altman analysis of 332 matched sets of CI data revealed an overall bias and precision of – 0.22 ± 0.52 L minute?1 m?2 for CIEV and CIPAC (percentage error: 30.4%). Trend analysis showed a concordance of 88% for CIEV. SVV showed a significant positive correlation (r2 = 0.442, p < 0.0001) with SV changes to a volume loading of 200 mL, but CVP did not (r2 = 0.0002, p = 0.94). Better prediction of SV responsiveness (rise of SV index of ≥ 10%) was observed for SVV (0.74 ± 0.09; p = 0.014) with a significant area under the receiver operating characteristic curve in comparison with CVP (0.53 ± 0.98; p = 0.78), with a cut-off value of 14.5% (60% specificity and 83% sensitivity).

Conclusions and clinical relevance

In dogs undergoing cardiovascular surgery, EV provided accurate CO measurements compared with CIPAC, although its trending ability was poor. Further, SVV by EV, but not CVP, reliably predicted fluid responsiveness during mechanical ventilation in dogs.  相似文献   

16.
17.
ObjectiveTo demonstrate if modified passive leg raise (PLRM) maneuver can be used for volumetric evaluation of fluid responsiveness (FR) by inducing cardiac output (CO) changes during experimental induction and correction of hypovolemia in healthy anesthetized dogs. The effects of PLRM on plethysmographic variability index (PVI) and pulse pressure variation (PPV) were also investigated.Study designProspective, crossover study.AnimalsA total of six healthy anesthetized Beagle dogs.MethodsDogs were anesthetized with propofol and isoflurane. They were mechanically ventilated under neuromuscular blockade, and normothermia was maintained. After instrumentation, all dogs were subjected to four stages: 1, baseline; 2, removal of 27 mL kg–1 circulating blood volume; 3, after blood re-transfusion; and 4, after 20 mL kg–1 hetastarch infusion over 20 minutes. A 10 minute stabilization period was allowed after induction of each stage and before data collection. At each stage, CO via pulmonary artery thermodilution, PVI, PPV and cardiopulmonary variables were measured before, during and after the PLRM maneuver. Stages were sequential, not randomized. Statistical analysis included repeated measures anova and Tukey’s post hoc test, considering p < 0.05 as significant.ResultsDuring stage 2, PLRM at a 30° angle significantly increased CO (mean ± standard deviation, 1.0 ± 0.1 to 1.3 ± 0.1 L minute–1; p < 0.001), with a simultaneous significant reduction in PVI (38 ± 4% to 21 ± 4%; p < 0.001) and PPV (27 ± 2% to 18 ± 2%; p < 0.001). The PLRM did not affect CO, PPV and PVI during stages 1, 3 and 4.Conclusions and clinical relevanceIn anesthetized dogs, PLRM at a 30° angle successfully detected FR during hypovolemia, and identified fluid nonresponsiveness during normovolemia and hypervolemia. Also, in hypovolemic dogs, significant decreases in PVI and PPV occurred in response to PLRM maneuver.  相似文献   

18.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号