首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An increase in the availability of advanced imaging modalities has led to improved recognition of cardiovascular anomalies. Computed tomography angiography (CTA) provides a non-invasive means of acquiring 3D images with a relatively short acquisition time thereby providing essential information in regards to patient anatomy and procedure planning. The dog in this report had a right aortic arch and abnormal branching with an aberrant left subclavian artery originating from the ampulla of a left patent ductus arteriosus (PDA) that was detected with CTA. The PDA was creating a volume overload to the left side of the heart as well as contributing to the vascular ring and compression of the esophagus. Therefore, ligation and transection instead of a minimally invasive catheter-based procedure was required. This aortic arch anomaly and surgical management have not been previously reported in dogs.  相似文献   

2.
A 12-week-old, clinically normal Chihuahua was referred for investigation for a continuous heart murmur. Cardiac evaluation revealed an anatomically and haemodynamically typical left-to-right shunting patent ductus arteriosus. The continuous wave Doppler measurement of peak ductal jet velocity of 5.6 m/s was suggestive of a normal pulmonary to systemic arterial pressure ratio. The dog returned 16 days later with right heart failure and severe pulmonary hypertension. Marked reduction in left-to-right shunting was demonstrated and the ductal jet velocity had decreased to 2.5 m/s. Immediate ductus ligation, oxygen therapy before and after the operation, and administration of hydralazine failed to reduce pulmonary hypertension, and the dog was euthanased. Histopathological examination of the lung showed pulmonary necrotising arteritis with acute and chronic arterial lesions. Chronic pulmonary vascular changes related to high flow have been associated with altered nitric oxide and endothelin responses. These changes may be responsible for the acute onset of pulmonary hypertension due to relatively minor vascular insults in some human and veterinary patients with left-to-right shunts. The potential for acute progression supports the recommendations for early ductus ligation and the prognostic importance of detecting pulmonary hypertension presurgically in patent ductus arteriosus patients.  相似文献   

3.
A patent ductus arteriosus (PDA) was detected in a 10-month-old Pyrenean Shepherd. The PDA was occluded with hemostatic clips. One month after surgery, an aneurysmal dilatation of the ductus was diagnosed using Doppler echocardiography. The authors present the echo-Doppler findings and the follow-up of the ductus aneurysm. The pathogenesis and significance of such an aneurysm are discussed.  相似文献   

4.
Surgical ligation of a left-to-right shunting patent ductus arteriosus was attempted in two animals. In both cases, a young cat and dog, ligation was complicated by poor visualization of the ductus resulting in unsuccessful ligation. Post-operatively, both the cat and dog underwent computed tomography angiography to characterize the location and morphology of the patent ductus arteriosus. In both cases, computed tomography angiography revealed a left-to-right shunting patent ductus arteriosus with an insertion location medial to the left pulmonary artery branch compared to the typical location. We hypothesize that this atypical location resulted in a difficult surgical visualization from the left thoracotomy approach. Transvenous coil embolization of the duct from the external jugular vein was performed in both cases and resulted in successful occlusion. Variations in the medial-lateral insertion of the ductus arteriosus may have consequences for surgical intervention. If an atypical location of a patent ductus arteriosus is suspected on transthoracic echocardiography, computed tomography angiography prior to ligation may be useful to further define ductal location and help guide the surgical approach.  相似文献   

5.
Patent ductus arteriosus with pulmonary hypertension and right to left shunting of blood flow was diagnosed in a 9-month-old female cat. Because of the pulmonary hypertension, the cat did not have typical signs of patent ductus arteriosus; thus, cardiac angiography and catheterization were utilized to confirm the diagnosis. The patent duct was successfully occluded with a vascular clip.  相似文献   

6.
OBJECTIVES: The objective of this study was to assess the feasibility of transcatheter embolisation of a patent ductus arteriosus using an Amplatzer vascular plug (Amplatzer Medical UK) in six dogs. METHODS: The Amplatzer vascular plug is a self-expandable, cylindrical device attached to a delivery cable. In all the dogs, the device was delivered transvenously. Successful device implantation was defined as firm anchorage of the device squarely within the distal part of the ductus arteriosus with no intra- or postoperative dislodgement. Successful occlusion of the ductus arteriosus occurred if a disappearance of the continuous murmur was achieved 24 hours after placement of the Amplatzer vascular plug. RESULTS: The age of the dogs ranged from 16 weeks to 7.5 years. Their weights ranged from 2.9 to 27.6 kg (median 6 kg). Two dogs had congestive heart failure before embolisation. Successful device implantation was achieved in all dogs. Successful occlusion of the ductus arteriosus was achieved in four of the six dogs. Complications included mild lameness, residual shunting, and bruising and pruritus around the surgical wound site. At follow-up, two dogs had a continuous murmur and one required treatment for congestive heart failure. CLINICAL SIGNIFICANCE: This technique may represent a clinically effective and less expensive alternative to the use of an Amplatzer duct occluder (Amplatzer Medical UK) in dogs with medium-sized patent ductus arteriosus. Further investigations are required to fully evaluate its efficacy and safety in various sizes and types of patent ductus arteriosus, and to determine the optimal device size in relation to the size of the ductus.  相似文献   

7.
Two cases of patent ductus arteriosus are described in 2 Murrah buffalos, a 7.5-month-old heifer calf and a 5-month-old bull calf. The main clinical signs consisted of exercise intolerance, dyspnea, and tachycardia. At necropsy, lesions were consistent with congestive heart failure as indicated by dependent subcutaneous edema, body cavity effusions, and nutmeg liver. The lungs were extensively atelectatic. The heart was enlarged and had a globous shape. The ductus arteriosus, measuring 0.8 cm in length and 0.4 cm in caliber, was patent. The proximal pulmonary artery had an approximately 50-mm-long aneurysm. Eccentric cardiac hypertrophy was evident primarily in the right but to a lesser degree also in the left ventricle. Additionally, there was diffuse subendocardial fibrosis in the left and right ventricle. To the best of the authors' knowledge, patent ductus arteriosus was not previously described in buffalos. Since both calves were sired by the same bull, it is possible that this cardiac anomaly has a hereditary basis.  相似文献   

8.
This study was designed to evaluate the feasibility and limitations of transcatheter embolization coil occlusion of patent ductus arteriosus in dogs using a carotid artery approach. Seven dogs examined at the University of California, Davis Veterinary Medical Teaching Hospital in 2002-2003 for evaluation of heart disease had congenital patent ductus arteriosus diagnosed by characteristic physical, electrocardiographic, radiographic, and anatomic and Doppler echocardiographic findings. Dogs were anesthetized for transesophageal echocardiography and transcatheter coil embolization of the ductus via the right external carotid artery. Coil embolization was achieved in all seven cases, using one to four detachable embolization coils. There were no major complications. Minor complications occurred in two dogs (additional coils placed using a femoral arterial approach and coil embolization of a left femoral artery branch). One dog was examined only 24 h post-operatively and had no murmur and trivial residual ductal flow by Doppler echocardiography. The other 6 dogs were clinically healthy when examined up to three years post-intervention. One dog had a very soft continuous murmur and mild residual ductal flow; the other five had no audible continuous murmur, with only one dog having trivial residual ductal flow identified by Doppler echocardiography. Although technically challenging, coil embolization via the carotid artery is a viable alternative approach for transcatheter closure of patent ductus arteriosus in some dogs.  相似文献   

9.
In this study the pedigrees of 42 German Shepherd dogs with German Shepherd dog Pyoderma (GSP) were analysed. Parents, littermates and offspring of the affected dogs were traced and their owners were questioned on characteristic skin lesions. Evidence suggesting an autosomal recessive trait was found. Breeders are advised to exclude affected animals and their relatives from further breeding.  相似文献   

10.
An 8-month-old spayed female Labrador retriever dog was evaluated for regurgitation 6 months after surgery for a suspected vascular ring anomaly. The dog had a history of regurgitation and slow development as a puppy. An initial left-sided exploratory thoracotomy was unsuccessful in identifying and treating a vascular ring anomaly. The dog was subsequently presented to the PennVet Emergency Service for regurgitation. Thoracic radiography showed cranial thoracic esophageal dilation and an esophageal foreign body that was then removed endoscopically. Subsequent computed tomographic (CT) angiography revealed a double aortic arch. A left 4th intercostal space thoracotomy was performed. The smaller left aortic arch and a left ligamentum arteriosum were ligated and transected. The dog recovered uneventfully and was healthy at the 1-month follow-up visit. This is the 5th reported successful surgical correction of a double aortic arch in a dog. Computed tomographic angiography was essential in diagnosis and surgical planning.Key clinical message:Although uncommon, double aortic arches can occur and present a diagnostic and surgical challenge when a persistent right aortic arch is suspected. Computed tomographic angiography provides an accurate preoperative diagnosis and allows for surgical planning.  相似文献   

11.
ObjectivesTo describe the use of the Amplatzer vascular plug II (AVPII) for transvenous occlusion of patent ductus arteriosus in a non-selective population of dogs, with a focus on the surgical technique, short term outcome and associated complications.Animals, materials and methodsRetrospective study. Records of thirty-two consecutive dogs treated for a left-to-right shunting patent ductus arteriosus with the AVPII were reviewed.ResultsDuctal occlusion with an AVPII occlusion device was attempted in 32 dogs weighing 1.1–53.8 kg. Transvenous occlusion was successful in 30 dogs. One dog required a transarterial approach for occlusion. One dog died during catheterisation of the right heart but prior to transductal catheterisation. Mean ductal ampulla diameter was 7.9 mm (range, 4.1–15.4 mm) and median size of deployed devices was 10 mm (range 4–20 mm). Mean device to ampulla ratio was 1.34 ± 0.15. Device was positioned in situ with no residual flow on follow-up echocardiographic assessment (> one month) in all dogs where deployment was attempted. Occlusion success rate was 96.9% and mortality rate was 3.1%. Four dogs (13.3%) demonstrated minor complications, with none having long-term significance.ConclusionsThe use of AVPII device via a transvenous approach is a feasible and effective method for occlusion of a left-to-right shunting patent ductus arteriosus in dogs of a wide range of weight. The method described may complement existing catheter-based occlusion methods.  相似文献   

12.
Summary

In this study the pedigrees of 42 German Shepherd dogs with German Shepherd dog Pyoderma (GSP) were analysed Parents, littermates and offspring of the affected dogs were traced and their owners were questioned on characteristic skin lesions. Evidence suggesting an autosomal recessive trait was found Breeders are advised to exclude affected animals and their relatives from further breeding.  相似文献   

13.
Transcatheter occlusion of patent ductus arteriosus (PDA) using an Amplatz® Canine Duct Occluder (ACDO) is routinely performed in dogs. Pulmonary embolization of the device is a rarely reported complication of this procedure. We report here the first two cases of successful transcatheter retrieval of an embolized ACDO. An 8-month-old, 21-kg, German shepherd (case 1) was referred for pulmonary edema secondary to a large PDA with left-to-right shunting. After medical stabilization, an emergency procedure for PDA closure was recommended. An 8-mm ACDO was deployed under general anesthesia. The device was released after confirming its stability with a gentle tug test but migrated into the pulmonary trunk. A 10-mm ACDO was subsequently successfully deployed and released. Vascular access was then obtained from the right jugular vein so that a vascular snare could be used to capture the ACDO waist and pull it back toward the right ventricle and then the right atrium. It was then removed through the jugular vein. The dog recovered uneventfully and was discharged after confirmation of complete ductal occlusion. The same complication occurred in a second case (case 2, asymptomatic 6-month-old, 7.9-kg, cocker spaniel), and a similar procedure was used to successfully retrieve the embolized device. Both dogs are still doing well 9 and 21 months, respectively, after the procedure. These cases illustrate that transcatheter retrieval of ACDO devices embolized in the pulmonary artery using vascular snares is technically feasible in the dog.  相似文献   

14.
A 6-months old female German shepherd dog was referred for management of congenital heart disease. A diagnosis of pulmonic stenosis (PS) and patent ductus arteriosus (PDA) was confirmed by Doppler echocardiography and cardiac catheterisation. The conditions were treated during a single cardiac catheterisation procedure using percutaneous techniques. Gianturco coil embolisation was used to close the PDA, and the PS was relieved using a balloon valvuloplasty technique.  相似文献   

15.
A 3-month-old female German Shepherd puppy was presented for routine vaccination. Clinical evaluation revealed a grade 5/6 continuous murmur with the point of maximal intensity over the left 4th intercostal space. Echocardiography revealed a patent ductus arteriosus (PDA). The PDA was closed by a team of general practitioners using the Jackson-Henderson technique, via a standard 4th intercostal thoracotomy. A multi-modal approach to analgesia and premedication was employed. A successful outcome was achieved with no murmur or evidence of cardiac disease present 6 months after surgical occlusion. The literature is reviewed with an emphasis placed on choosing techniques that are appropriate to the level of expertise of the surgical and anaesthetic teams, as well as the surgical facilities available.  相似文献   

16.
During early fetal life six pair of aortic arches surround the esophagus and trachea. Normal maturation and selective regression of these structures form the adult vasculature. Abnormal location or development of the aortic arches may result in pressure on adjacent organs.Vascular ring anomalies must be considered with any patient with a history of regurgitating food shortly after eating. Physical examination, test feedings, survey and contrast radiographs may give an accurate impression of the problem but a final diagnosis can only be made following surgical exploration. In the case presented, the dog had all the clinical and diagnostic signs suggestive of a vascular ring anomaly. Thoracotomy and elimination of the vascular constriction around the esophagus was both diagnostic and therapeutic for the condition. It is important that owners be made aware that surgical correction of the stenosis does not guarantee a successful conclusion to the case. If the dilation of the esophagus cranial to the stenosis is severe, accumulation of food with subsequent regurgitation may persist. A dilation of the esophagus caudal to the stenosis is present in a large percentage of cases and this also may result in an unrelenting problem. Unfortunately, the probability of these complications cannot be accurately evaluated prior to treatment.The hereditary potential for this defect must also be considered. Congenital vascular anomalies such as patent ductus arteriosus would seem to have a hereditary basis. Therefore, it is probably correct to advise against breeding affected animals. Further, the inbreeding of nonaffected animals which come from litters containing affected animals should be avoided.  相似文献   

17.
A 10 week old female intact Staffordshire terrier was presented with a total of five congenital cardio-thoracic vascular anomalies consisting of a patent ductus arteriosus (PDA) with an aneurysmic dilation, pulmonic stenosis, persistent right aortic arch, aberrant left subclavian artery and persistent left cranial vena cava. These abnormalities were identified with a combination of echocardiogram and computed tomography angiography (CTA). The abnormalities were associated with esophageal entrapment, regurgitation, and volume overload of the left heart with left atrial and ventricular enlargement. A 2 cm diameter aneurysmic dilation at the junction of the PDA, right aortic arch and aberrant left subclavian artery presented an unusual surgical challenge and precluded simple circumferential ligation and transection of the structure. A full scale three dimensional model of the heart and vasculature was constructed from the CTA and plasma sterilized. The model was used preoperatively to facilitate surgical planning and enhance intraoperative communication and coordination between the surgical and anesthesia teams. Intraoperatively the model facilitated spatial orientation, atraumatic vascular dissection, instrument sizing and positioning. A thoracoabdominal stapler was used to close the PDA aneurysm prior to transection. At the four-month postoperative follow-up the patient was doing well. This is the first reported application of new imaging and modeling technology to enhance surgical planning when approaching correction of complex cardiovascular anomalies in a dog.  相似文献   

18.
Twenty-nine dogs, including 13 Great Danes and 5 German Shepherd Dogs and averaging 7.3 months age, were diagnosed clinically and radiographically as having mitral regurgitation. Alterations of the mitral valve complex included enlarged anulus; short thick leaflets, with an occasional cleft; short and stout or long and thin chordae tendineae; upward malposition of atrophic or hypertrophic papillary muscles; insertion of one papillary muscle directly into one or both leaflets; and diffuse endocardial fibrosis, occasionally with jet lesions in te left atrium. Other cardiac anomalies included dysplasia of the tricuspid valve (5 dogs), patent ductus afteriosus (2 dogs), aortic stenosis (2 dogs), and ventricular septal defect (1 dog).  相似文献   

19.
A 5-year-old cocker spaniel with tachycardia, > 2 s capillary refill time, arrhythmia, split S2 heart sound, right ventricular enlargement, flattened interventricular septum, dilated pulmonary artery, and slight tricuspid valve insufficiency was diagnosed with reversed patent ductus arteriosus (right-to-left vs the more common left-to-right shunt). Two years later, the dog was still stable.  相似文献   

20.
A 6‐month old female alpaca cria presented to The Ohio State University for evaluation of a cardiac murmur. Echocardiography revealed a left‐to‐right shunting patent ductus arteriosus, a restrictive left‐to‐right shunting perimembranous ventricular septal defect, and secondary moderate left atrial and ventricular dilation. Aortic root angiography demonstrated a type IIA patent ductus arteriosus (PDA). Interventional closure of the PDA was successfully performed, without complication, using an Amplatz canine duct occluder. This case report describes the materials and methods used for interventional closure of a PDA in an alpaca cria.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号