首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
Transvenous cardiac pacing in 19 dogs and one cat   总被引:2,自引:0,他引:2  
Eighteen dogs and one cat with symptomatic bradycardias were equipped with cardiac pacemakers. One further dog died during anaesthesia for pacemaker placement. Each animal was sedated, and a ‘tined’ transvenous pacing lead was passed to the apex of the right ventricle from the jugular vein. Following temporary pacing and general anaesthesia, the permanent pacemaker was placed subcutaneously at the neck in the dogs and at the abdominal wall in the cat. In 11 dogs and the cat, the pacemaker was implanted in a dacron pouch. Complications (mainly serous reaction to the pacemaker) developed in four out of seven dogs in which no pouch had been employed. The pacing lead was retained after discharge from hospital in all except one dog. Pacing successfully relieved clinical signs in all cases. Fifteen out of 18 dogs and the cat survived one year after pacing and the mean survival time was greater than 18 months. Transvenous pacing is a simple and reliable technique that avoids transthoracic or transabdominal surgery for pacemaker lead placement.  相似文献   

2.
3.
Transvenous cardiac pacing is a commonly employed treatment for symptomatic bradyarrhythmias in dogs. Medical management of these conditions has not proven to be successful leaving pacing as the only viable alternative. The technique of pacemaker implantation is not difficult, but successful pacemaker therapy requires an understanding of electrophysiology, cardiac fluoroscopic anatomy, pacemaker instrumentation, and programming. Proper patient selection and identification of the underlying rhythm disturbance is essential to a successful clinical outcome. This article discusses the indications, equipment, techniques, complications, and outcome of permanent transvenous cardiac pacing.  相似文献   

4.
Temporary cardiac pacing is used in the emergency treatment of life-threatening bradyarrhythmias and for the support of heart rate and blood pressure of patients with sick sinus syndrome or high-grade atrioventricular (AV) block undergoing general anesthesia, typically for permanent pacemaker implantation. We retrospectively evaluated the safety and efficacy of a noninvasive transthoracic external cardiac pacing system in 42 dogs treated for bradyarrhythmias. Optimal placement of the patch electrodes on the skin of the thorax was initially established on 2 anesthetized normal dogs. The optimal electrode placement was determined to be on the right and left hemithoraces, directly over the heart. Afterward, by means of this electrode placement all 42 dogs treated for bradyarrhythmias in this study were successfully paced with the noninvasive transthoracic system. Dogs ranged in age from 1 to 15 years and weighed between 3.2 and 40 kg. Miniature Schnauzers, German Shepherds, and mixed breeds were most common in the study population. Indications for noninvasive transthoracic pacing included emergency treatment of hemodynamically unstable 3rd-degree AV block (2 dogs): support of heart rate during general anesthesia for permanent pacemaker implantation or lead-wire adjustment (38 dogs): and support of heart rate during general anesthesia for ophthalmologic surgery in dogs with sick sinus syndrome (2 dogs). Complications included pain and skeletal muscle stimulation, which required general anesthesia. We conclude that the noninvasive transthoracic pacing system evaluated is satisfactory for clinical veterinary use.  相似文献   

5.
ObjectiveCompare the efficacy of two cardiac pacing catheters for transesophageal atrial pacing (TAP).AnimalsTen healthy dogs.MethodsTransesophageal atrial pacing was attempted in left lateral recumbency under general anesthesia. In series, a curved electrophysiologic (EP) catheter and a straight transesophageal pacing (TP) catheter were passed transorally into the distal esophagus, caudal to the heart. Each catheter was slowly withdrawn until pacing was initiated. The catheter continued to be withdrawn in 5 mm increments until capture was no longer achieved at maximal pacing setting creating a total zone of capture (tZOC). Minimum pacing threshold (Thmin) and degree of extraneous muscle stimulation (EMS) were determined at each site.ResultsThe EP catheter achieved TAP in 10/10 dogs with a Thmin of 8.8 ± 4.8 mA and tZOC of 4.0 ± 1.7 cm. The TP catheter achieved TAP in 7/10 dogs with a Thmin of 22.5 ± 5.6 mA and tZOC of 1.2 ± 1.6 cm. No EMS was noted during TAP at Thmin using the EP catheter. Of the 7 dogs in which TAP was successful, 3/7 experienced considerable EMS at Thmin. There was no significant relationship between patient body weight and Thmin with either catheter (EP catheter P = 0.09; TP catheter P = 0.81).ConclusionsThe electrophysiology catheter captured the atria of more dogs over a larger area without EMS as compared to the TP catheter. The electrophysiology catheter is recommended for transesophageal atrial pacing in dogs.  相似文献   

6.
Artificial pacing (AP) is a treatment for symptomatic bradyarrhythmias unresponsive to medical therapy. This retrospective study was designed to define the practices and outcome of AP in dogs at 7 referral institutions participating in the Companion Animal Pacemaker Registry and Repository (CANPACERS). The indications, implantation techniques, complications, long-term outcome, and owner satisfaction were examined. One hundred fifty-four dogs were identified as undergoing AP from January 1, 1991, to January 1, 1996. Third-degree atrioventricular (AV) block (n = 91; 59%) and sinus node dysfunction (n = 45; 29%) were the most common indications for AP Transvenous endocardial AP systems were implanted in 136 dogs (88%), and epicardial systems were implanted in 18 (12%). Complications associated with AP were reported in 84 dogs (55%). Major complications occurred in 51 dogs (33%), including dislodgement of the pacing lead (n = 15; 10%), generator failure (n = 10; 6%), cardiac arrest during implantation (n = 9; 6%), and infection (n = 7; 5%). Minor complications occurred in 47 dogs (31%), including seroma formation (n = 18; 12%), muscle twitch (n = 17; 11%), and inconsequential arrhythmias (n = 15; 10%). Fourteen dogs (9%) experienced both major and minor complications. Survival analysis revealed 1-, 2-, and 3-year survival rates of 70, 57, and 45%, respectively. Age and presence of preexisting congestive heart failure (CHF) had a negative effect on survival (P = .001). Sixty percent of dogs with preexisting CHF died within 1 year of implantation, whereas 25% of dogs without heart failure died during the same period. Owners rated their satisfaction with the procedure as high in 80% of the dogs.  相似文献   

7.
Objective: This case report presents the clinical findings of a dog with diltiazem intoxication and the utilization of temporary transvenous pacing for management of high‐grade second‐degree atrioventricular (AV) block with associated bradycardia and hypotension. Case summary: A nine‐year‐old spayed female Basset Hound, who ingested between 95 and 109 mg/kg of sustained‐release diltiazem exhibited clinical signs of cardiac arrhythmias, bradycardia, hypotension, mental depression and gastrointestinal (GI) upset. Bradycardia was present initially, then was followed by high‐grade second‐degree AV block with ventricular escape. Traditional medications to treat calcium channel blocker (CCB) intoxication, including atropine, calcium gluconate, dopamine and glucagon were initially successful in managing the cardiac rhythm disturbances and hypotension. Twenty‐two hours post‐ingestion, however, the dog became refractory to these medications following sedation for GI decontamination and a temporary transvenous pacemaker was placed. The dog was paced for 19 hours. Transvenous pacing effectively increased heart rate, which increased blood pressure into an acceptable range. The dog was successfully discharged from the hospital following treatment. New or unique information provided: The use of a temporary pacemaker should be considered an acceptable treatment for bradycardia, AV block and hypotension associated with CCB intoxication when conventional medical therapy fails.  相似文献   

8.
Permanent Transvenous Pacemaker Implantation in Forty Dogs   总被引:1,自引:0,他引:1  
Permanent transvenous cardiac pacemakers were implanted in 40 dogs. Electrocardiographic diagnoses included persistent atrial standstill (3 dogs), sick sinus syndrome (8 dogs), and high-grade second-degree or third-degree atrioventricular (AV) block (29 dogs). Thirteen dogs were alive and well 4 to 42 months after pacemaker implantation (mean, 16.9 months). The mean and median survival times of the 26 dogs that died or were euthanatized during the study were 17.9 months and 13 months, respectively. Most of these dogs succumbed to problems unrelated to the arrhythmia and pacemaker implant. One dog was lost to follow-up. Complications associated with permanent transvenous pacemaker implantation included lead dislodgement, infection, hematoma formation, skeletal muscle stimulation, ventricular arrhythmia, migration of the pulse generator, and skin erosion. Lead dislodgement was the most common complication, occurring in 7 of 9 dogs paced using untined electrode leads and in 6 of 30 dogs paced using tined leads. Lead dislodgement did not occur in the only dog paced using an actively fixed endocardial lead. It was concluded that permanent transvenous cardiac pacing is a feasible, less traumatic alternative to epimyocardial pacing in dogs, but that successful use of this technique requires careful implantation technique and anticipation of the potential complications.  相似文献   

9.
Atrial fibrillation is characterized by uncoordinated electrical activation of the atria that leads to the loss of atrial mechanical function and atrial fibrosis as a substrate promoting maintenance of rhythm abnormality. Transvenous electrical cardioversion has not been previously reported in the dog. The authors demonstrate the use of this technique for successful cardioversion of atrial fibrillation in two dogs with dilated cardiomyopathy.  相似文献   

10.
Conventional treatment of equine atrial fibrillation (AF) involves administration of quinidine salts. Most uncomplicated cases respond to treatment, but pharmacologic cardioversion involves a range of adverse effects, and some horses are unable to tolerate medication. A study was undertaken to develop transvenous electrical cardioversion (TVEC) as an alternative treatment. Safety issues and catheter placement techniques with catheter-integrated cardioversion electrodes were investigated, and responses to shock application were evaluated. After the premortem catheterization of elective-euthanasia horses, no tissue abnormalities were detected at postmortem examination. To evaluate the response to the application of shocks and appropriate electrode positions, an electrical cardioversion of research horses in chronic AF was then attempted. After catheterization of the right atrium (RA) and pulmonary artery through the right jugular vein, horses were placed under general anesthesia. Biphasic, truncated exponential shock waves were delivered at incremental energies until cardioversion was achieved or until a maximum energy of 300 J was reached. Five treatment events were applied to 3 horses, with cardioversion achieved in one of the treatment events. No adverse effects of cardioversion attempts or general anesthesia were observed. The procedure was then applied to 8 client-owned horses, with cardioversion achieved in 7. No adverse responses to appropriately delivered shocks were observed. No antiarrhythmic medications were administered to any horse at any stage. Catheter design and placement technique evolved throughout the study, with combined ultrasonography and pressure guidance proving most effective in achieving appropriate electrode placement. Results suggest TVEC, as applied in the present study, is a safe, effective, and realistic therapeutic option for equine AF.  相似文献   

11.
Tined transvenous pacing leads were inserted into nine healthy large-breed dogs as part of an experimental study evaluating an implantable defibrillator. The pacing leads were used to induce ventricular fibrillation on the day of insertion, two and four weeks after insertion and then monthly. Despite daily running exercise on and off a leash, the tined leads remained firmly anchored to the right ventricular apex for the full experimental period of up to 12 months. Apart from mechanical endocarditis of the tricuspid valve, and partial penetration of the ventricular wall in one dog, problems associated with the pacing leads were not encountered. The use of tined leads and careful technique may minimise the likelihood of transvenous lead displacement.  相似文献   

12.
ObjectiveTo report on transvenous detachable coiling in small dogs deemed ineligible for traditional transarterial patent ductus arteriosus occlusion and compare transthoracic echocardiographic and angiographic measurements to determine their equivalence.Materials and methodsA retrospective study of 35 dogs that underwent transvenous coiling of a patent ductus arteriosus. Demographic information, echocardiographic and angiographic studies, surgery reports, and follow-up evaluation of residual flow were obtained. A Bland-Altman analysis was used to compare echocardiographic and angiographic measurements of the minimal ductal diameter (Echo-MDD, Ang-MDD) and ampulla diameter (Echo-A, Ang-A).ResultsThirty-four of 35 dogs had successful deployment of a coil, with one dog undergoing occlusion with a different device after the exteriorized coil pulled through the ductus. Complete occlusion was achieved in 18 dogs within 24 h; four dogs were lost to follow-up, and the remaining 12 dogs had no residual flow or a significant reduction in shunting with normalization in cardiac chamber dimensions by a median of 99 days. Thirty percent of dogs (11/35) experienced perioperative complications of which 10 were minor complications. The analysis of 26 dogs with both echocardiographic and angiographic ductal measurements showed a −0.14 mm mean difference (95% limits of agreement −1.08 to 0.8 mm) in minimal ductal diameter and −0.68 mm mean difference (95% limits of agreement −2.73 to 1.37 mm) in ampulla diameter.ConclusionsDogs less than 3 kg deemed too small for transarterial occlusion can successfully undergo transvenous coil embolization of patent ductus arteriosus.  相似文献   

13.
A 6-year-old male castrated labrador retriever presented with endocardial pacemaker infection following migration and subsequent repositioning of the pulse generator. An epicardial lead and pulse generator were surgically implanted and the endocardial lead could not be removed with manual traction. The endocardial lead was severed, anchored, and abandoned at the thoracic inlet. The patient presented 4 months later with endocardial lead migration, bacteremia, and suspected glomerulonephritis. The endocardial pacemaker lead was transvenously extracted using a mechanical dilator sheath and locking stylet. This report of transvenous pacemaker lead extraction in a dog addresses the challenges and describes recent advances in extraction devices.  相似文献   

14.
Transvenous retrograde portography for identification and characterization of portosystemic shunts in dogs A method for transvenous retrograde portography (TRP) in dogs suspected to have a portosystemic shunt (PSS) and results in 20 dogs are described. For TRP, dogs were anesthetized and positioned in left lateral recumbency A dual-lumen balloon-tipped catheter was inserted into the right jugular vein and advanced into the azygos vein. The balloon was inflated to occlude the azygos vein, and contrast material was injected during fluoroscopic evaluation. The catheter was then positioned in the caudal vena cava just cranial to the diaphragm. The balloon was again inflated to occlude the vena cava, and contrast material was again injected. Once a shunt was identified, selective catheterization was attempted with a guide wire and angled catheter. A PSS was identified in 18 of the 20 dogs. In 10 of the 18, the shunt vessel could be selectively catheterized, allowing measurement of portal pressures while the shunt was occluded with the balloon. In 1 dog, results of TRP were normal, but subsequent exploratory celiotomy revealed a single extrahepatic PSS, which was surgically attenuated. The other dog in which results of TRP were normal did not have a macroscopic PSS. In dogs suspected to have a PSS, TRP may be a useful adjunctive diagnostic test that is less invasive than operative mesenteric vein portography and allows measurement of portal pressures before and after temporary shunt occlusion.  相似文献   

15.
The National Board of Veterinary Medical Examiners was interested in the possible effects of word count on the outcomes of the North American Veterinary Licensing Examination. In this study, the authors investigated the effects of increasing word count on the pacing of examinees during each section of the examination and on the performance of examinees on the items. Specifically, the authors analyzed the effect of item word count on the average time spent on each item within a section of the examination, the average number of items omitted at the end of a section, and the average difficulty of items as a function of presentation order. The average word count per item increased from 2001 to 2008. As expected, there was a relationship between word count and time spent on the item. No significant relationship was found between word count and item difficulty, and an analysis of omitted items and pacing patterns showed no indication of overall pacing problems.  相似文献   

16.
Transvenous embolization of small patent ductus arteriosus (PDA; < or = 4 mm) with a single detachable coil was attempted in 24 dogs (median age 5.7 months, range, 2.6-65.5 months; median body weight 5.5 kg, range, 1.5-30.0 kg). Angiographic imaging of the duct and pressure measurements were made before and after embolization. The minimal ductal diameter was 2.7 +/- 0.7 mm. In all dogs, a single coil was employed regardless of residual shunting. Ten dogs (PDA minimal diameter range, 1.5-2.2 mm) received a 5-mm coil, and 14 dogs (PDA minimal diameter range, 2.9-3.6 mm) received a 8-mm coil. After coil embolization the angiographic shunt grade decreased significantly (n = 20, P < .001). Residual shunts were assessed by angiography 15 minutes after and by Doppler echocardiography 1-3 days and 3 months after the intervention. In the dogs treated with the 5-mm coils the residual shunt rate was low (0%, 10%, and 0% for angiography and Doppler echocardiography at 1-3 days and 3 months, respectively), in contrast to the dogs treated with the 8-mm coils (91%, 79%, and 67% for angiography and Doppler echocardiography at 1-3 days and 3 months, respectively). After 3 months, no residual murmur was found in dogs treated with the 5-mm coils (0/7), in contrast to murmurs in 5 of 12 (42%) dogs treated with the 8-mm coils. Despite incomplete closure in these dogs, volume loading of the left heart decreased in all dogs. Pulmonic or aortic coil embolism did not occur. Analysis of initial results shows that single detachable coil embolization is possible in all dogs with a small PDA (< or = 4 mm), but only very small PDA (< or = 2.5) could be treated effectively, and for the moderate PDA (2.6-4.0 mm) longer coils or multiple coils may be necessary to achieve complete occlusion.  相似文献   

17.
18.
Vertebral heart size (VHS) has been proposed as a method for quantifying cardiomegaly in dogs. This study was designed to determine how well echocardiographic and electrocardiographic findings correlated with VHS. Dogs were rapid-paced into varying degrees of cardiomegaly and were monitored by thoracic radiography, echocardiography, and electrocardiography during development of cardiomegaly. Echocardiographic and electrocardiographic parameters were compared with VHS. VHS increased with increased duration or rate of pacing or both, and left atrium-to-aorta ratio, left ventricular end-diastolic diameter, left ventricular end-systolic diameter, P wave duration, and QRS duration correlated significantly with VHS. VHS (a score obtained from routine thoracic radiographs) seems to correlate well with both echocardiographic and electrocardiographic parameters. When 9 veterinarians, experienced in interpretation of cardiac silhouettes on radiographs, measured VHS from 1 normal dog and 1 dog with severe cardiomegaly, coefficients of variation (ratio of standard deviation to the mean) for their measurements were 2.7% and 2.8%, respectively. Thus, VHS could be established with great uniformity by experienced interpreters.  相似文献   

19.
This article describes the treatment of single congenital portosystemic shunts (CPSs) (intrahepatic and extrahepatic) using an interventional radiology technique involving embolisation of anomalous vessels with percutaneous coils. Briefly, a multipurpose catheter was introduced into the caudal vena cava and then into the portosystemic shunt. An autoexpandable stent was placed in the caudal vena cava, next to the shunt, in order to avoid coil migrations, and a cobra-like vascular catheter was used to pass through the stent and to place the coils in the shunt. This technique was used for treatment of CPS in six dogs. The results indicate that percutaneous embolisation of a CPS using coils, a less invasive technique than the traditional surgical technique, may result in complete closure of the anomalous vessel without development of portal hypertension.  相似文献   

20.
Pharmacological conversion of atrial fibrillation (AF) to sinus rhythm in horses can be difficult. The objective of this study was to investigate the feasibility of transvenous electrical cardioversion with custom made catheters in eight horses, of which three had failed cardioversion using quinidine sulfate. Two cardioversion catheters and one pacing/sensing electrode were inserted via the right jugular vein and placed using ultrasound guidance into the left pulmonary artery, the right atrium and the right ventricle, respectively. Because immediate recurrence of AF was encountered in the second horse treated, pre-treatment with amiodarone was given to each of the remaining six horses. Induction of general anaesthesia was associated with dislocation of the cardioversion catheter in three horses, requiring a second catheterisation procedure. During general anaesthesia, biphasic R wave synchronised shocks of up to 360 J were delivered between both cardioversion electrodes. In six horses (75%), including two which had failed quinidine sulfate treatment, sinus rhythm was restored with a mean energy level of 295+/-62 J. No side effects were observed. Blood analysis 3 h after cardioversion revealed normal parameters, including cardiac troponin I values. Transvenous electrical cardioversion of atrial fibrillation with custom made cardioversion catheters can be considered as a treatment option for atrial fibrillation in horses, especially when conventional drugs fail.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号