MATTHIEU GATINEAU DMV LOUIS HUNEAULT DMV MSc Diplomate ACVS BERTRAND LUSSIER DMV MSc Diplomate ACVS JOSIANE LEFEVRE-LAVOIE MSc 《Veterinary surgery : VS》2010,39(1):48-53
Objective— To compare the effects of hydrogen peroxide gas plasma (HPGP) and ethylene oxide (EO) sterilizations on the mechanical properties of nylon lines used for stabilization of the canine stifle. Secondarily, to compare the performance of crimped and knotted lines.
Study Design— In vitro mechanical evaluation.
Sample Population— Nonsterilized, EO- and HPGP-sterilized specimens of 36.3 kg test nylon leader line (NLL) and 57.8 kg test nylon fishing line (NFL).
Methods— Single strands and looped specimens of NLL or NFL were positioned on a material testing machine. To create looped specimens, NLL were crimped using the Securos system, and NFL were knotted, as used clinically. Elongation (%) and ultimate load (N) variables were studied.
Results— Elongation and ultimate load of NLL groups were not significantly different between EO and HPGP. For NFL, HPGP sterilization led to slightly greater elongation than EO in loops only. Ultimate load of NFL single strands was not significantly different between EO and HPGP, but was higher after HPGP compared with EO in NFL loops. All NLL groups had less elongation and ultimate load than NFL.
Conclusion— The effects of HPGP on NLL compared positively to EO, making HPGP an attractive alternative. As HPGP led to a slightly greater elongation of NFL than EO, the latter could be favored to sterilize NFL. Crimped NLL minimized elongation better than knotted NFL.
Clinical Relevance— Sterilization with HPGP seems a good alternative to EO for NLL. EO may be a better choice for NFL; however, it is difficult to judge the clinical relevance of this result. Crimped NLL minimizes elongation and may help reducing the recurrence of stifle instability postoperatively. 相似文献
Study Design— In vitro mechanical evaluation.
Sample Population— Nonsterilized, EO- and HPGP-sterilized specimens of 36.3 kg test nylon leader line (NLL) and 57.8 kg test nylon fishing line (NFL).
Methods— Single strands and looped specimens of NLL or NFL were positioned on a material testing machine. To create looped specimens, NLL were crimped using the Securos system, and NFL were knotted, as used clinically. Elongation (%) and ultimate load (N) variables were studied.
Results— Elongation and ultimate load of NLL groups were not significantly different between EO and HPGP. For NFL, HPGP sterilization led to slightly greater elongation than EO in loops only. Ultimate load of NFL single strands was not significantly different between EO and HPGP, but was higher after HPGP compared with EO in NFL loops. All NLL groups had less elongation and ultimate load than NFL.
Conclusion— The effects of HPGP on NLL compared positively to EO, making HPGP an attractive alternative. As HPGP led to a slightly greater elongation of NFL than EO, the latter could be favored to sterilize NFL. Crimped NLL minimized elongation better than knotted NFL.
Clinical Relevance— Sterilization with HPGP seems a good alternative to EO for NLL. EO may be a better choice for NFL; however, it is difficult to judge the clinical relevance of this result. Crimped NLL minimizes elongation and may help reducing the recurrence of stifle instability postoperatively. 相似文献
2.
C. COLLINS ANDERSON III DVM JAMES L. TOMLINSON DVM MVSC Diplomate ACVS WILLIAM R. DALY DVM Diplomate ACVS WILLIAM L. CARSON PhD JOHN T. PAYNE DVM MS Diplomate ACVS COLETTE C. WAGNER-MANN DVM PhD 《Veterinary surgery : VS》1998,27(6):533-539
Objective —To test a crimp clamp system designed to secure monofilament nylon leader (MNL) material commonly used as lateral fabellotibial sutures (LFS) in extra-articular stabilization of the canine stifle joint.
Study Design — In vitro biomechanical tests of MNL loops secured with either the crimp clamp system or knots were performed. Suture loops (n = 94) were created from 27.3 kg tensile strength MNL and fastened with knots or crimp clamps. Tests were conducted on steam-sterilized, ethylene-oxide-sterilized, and nonsterilized MNL sutures. Loops were evaluated in single load tests and cycled tests. Values for load to failure, initial loop tension, loop elongation, mode of failure, and point of failure were determined.
Results —Crimp-clamped loops were superior to knotted loops in all parameters tested in both cycled and noncycled tests. Loop failure generally occurred by breaking within 3 mm of the fixation in both clamped and knotted tests. Loop elongation after cycling was greater in the knotted loops compared with clamped loops ( P < .001). Load to failure was greater in clamped tests than in knotted tests (P < .001), regardless of sterilization technique used. Significantly higher initial loop tension could be achieved with the clamp system compared with knot fixation ( P < .001).
Conclusions —The crimp clamp system provides superior in vitro loop fixation characteristics compared with knot fixation in 27.3 kg test MNL.
Clinical Relevance —Based on the results of biomechanical testing and the known biocompatibility of the system's implant components, clinical trials using the crimp clamp system are warranted. 相似文献
Study Design — In vitro biomechanical tests of MNL loops secured with either the crimp clamp system or knots were performed. Suture loops (n = 94) were created from 27.3 kg tensile strength MNL and fastened with knots or crimp clamps. Tests were conducted on steam-sterilized, ethylene-oxide-sterilized, and nonsterilized MNL sutures. Loops were evaluated in single load tests and cycled tests. Values for load to failure, initial loop tension, loop elongation, mode of failure, and point of failure were determined.
Results —Crimp-clamped loops were superior to knotted loops in all parameters tested in both cycled and noncycled tests. Loop failure generally occurred by breaking within 3 mm of the fixation in both clamped and knotted tests. Loop elongation after cycling was greater in the knotted loops compared with clamped loops ( P < .001). Load to failure was greater in clamped tests than in knotted tests (P < .001), regardless of sterilization technique used. Significantly higher initial loop tension could be achieved with the clamp system compared with knot fixation ( P < .001).
Conclusions —The crimp clamp system provides superior in vitro loop fixation characteristics compared with knot fixation in 27.3 kg test MNL.
Clinical Relevance —Based on the results of biomechanical testing and the known biocompatibility of the system's implant components, clinical trials using the crimp clamp system are warranted. 相似文献
3.
TOBY J. GEMMILL BVSc MVM DSAS Diplomate ECVS MICHAEL FARRELL BVetMed CertVA CertSAS Diplomate ECVS 《Veterinary surgery : VS》2009,38(5):588-594
Objectives— To assess a novel technique for arthroscopic evaluation of the canine stifle avoiding the need for fat pad debridement.
Study Design— Prospective study.
Sample Population— Cadaveric canine stifles (n=10); Client-owned dogs (15).
Methods— In cadaveric stifles, the femoropatellar space was assessed before placement of a joint distractor and examination of the femorotibial joint. Time to complete evaluation of the femoropatellar space, to observe the cruciate ligaments, and to completion of examination of the femorotibial joint were recorded. Distractor-assisted arthroscopy was then performed in 15 consecutive clinical cases. Clinical information, time to complete joint evaluation, and ability to perform any additional arthroscopic surgery were recorded.
Results— Observation and palpation of intra-articular structures were possible in all cadaveric stifles. Mean time to evaluate the femoropatellar space was 3.2 minutes (range, 2–4 minutes); to observe the cruciate ligaments, 5.8 minutes (range, 3–8 minutes); and to completion of joint inspection, 9.1 minutes (range 6–13 minutes). In the clinical cases, observation of intra-articular structures was also possible in all stifles. Mean time to complete joint inspection was 21 minutes (range, 10–40 minutes). Partial meniscectomy was performed successfully in 5 stifles.
Conclusions— Use of a joint distractor allowed arthroscopic observation of all relevant structures. Partial meniscectomy was readily performed.
Clinical Relevance— Use of a joint distractor may simplify arthroscopic assessment of the canine stifle and avoid potential morbidity associated with fat pad debridement. 相似文献
Study Design— Prospective study.
Sample Population— Cadaveric canine stifles (n=10); Client-owned dogs (15).
Methods— In cadaveric stifles, the femoropatellar space was assessed before placement of a joint distractor and examination of the femorotibial joint. Time to complete evaluation of the femoropatellar space, to observe the cruciate ligaments, and to completion of examination of the femorotibial joint were recorded. Distractor-assisted arthroscopy was then performed in 15 consecutive clinical cases. Clinical information, time to complete joint evaluation, and ability to perform any additional arthroscopic surgery were recorded.
Results— Observation and palpation of intra-articular structures were possible in all cadaveric stifles. Mean time to evaluate the femoropatellar space was 3.2 minutes (range, 2–4 minutes); to observe the cruciate ligaments, 5.8 minutes (range, 3–8 minutes); and to completion of joint inspection, 9.1 minutes (range 6–13 minutes). In the clinical cases, observation of intra-articular structures was also possible in all stifles. Mean time to complete joint inspection was 21 minutes (range, 10–40 minutes). Partial meniscectomy was performed successfully in 5 stifles.
Conclusions— Use of a joint distractor allowed arthroscopic observation of all relevant structures. Partial meniscectomy was readily performed.
Clinical Relevance— Use of a joint distractor may simplify arthroscopic assessment of the canine stifle and avoid potential morbidity associated with fat pad debridement. 相似文献
4.
KEVIN A. R. KUNKEL DVM R. RANDY BASINGER DVM DIPLOMATE ACVS JONATHAN T. SUBER DVM PATRICK D. GERARD PhD 《Veterinary surgery : VS》2009,38(8):975-982
Objective— To evaluate use of a transcondylar toggle system (TCTS) for stabilization of the cranial cruciate ligament (CrCL) deficient stifle in small dogs and cats. Study Design— Prospective clinical study. Animals— Small dogs (<7 kg; n=14) and cats (2) with CrCL‐associated lameness of <3 months duration and a tibial plateau angle <32°. Methods— Affected animals had an extracapsular CrCL repair using the TCTS. Lameness score, muscle atrophy, osteoarthritis (OA) score, and range of motion (ROM) were evaluated preoperatively, and at 6 weeks and 7–10 months postoperatively. Results— Operative time was 75 ± 16 minutes. Fifty‐six percent required >1 bone tunnel attempts. One dog required revision at 2 weeks because of suture loosening. All stifles were stable at 6 weeks postoperatively. Fifteen animals were available for follow‐up (7–10 months). Lameness improved significantly at 6 weeks (P<.0001), whereas muscle atrophy was worse at 6 weeks (P=.008) but improved at 7–10 months (P<.0001). OA scores were unchanged at 6 weeks (P=.08) but were significantly worse at 7–10 months (P<.0001). ROM remained unchanged at 6 weeks (P=1) and 7–10 months (P=.6). Conclusions— The medially placed toggle provides a reliable short‐term proximal anchor for the extracapsular suture with outcomes similar to other extracapsular techniques. The aiming device and drill bit are not recommended in their current form. Clinical Relevance— The TCTS appears to be a well‐tolerated technique for proximal suture anchoring in extracapsular CrCL repair in small dogs and cats where instrumentation and anatomic constraints preclude other techniques. 相似文献
5.
A study of the histologic organization of normal synovial membranes of the stifle joint of the horse is described. Three types of synovial membrane, which appear to be randomly distributed within the stifle joint, are described. 相似文献
6.
D. A. Shigue S. C. Rahal B. C. Schimming R. R. Santos L. C. Vulcano J. L. Linardi C.R. Teixeira 《Anatomia, histologia, embryologia》2015,44(6):468-474
This study aimed to evaluate the stifle joint of marsh deer using imaging studies and in comparison with gross anatomy. Ten hindlimbs from 5 marsh deer (Blastocerus dichotomus) were used. Radiography, computed tomography (CT) and magnetic resonance imaging (MRI) were performed in each stifle joint. Two hindlimbs were dissected to describe stifle gross anatomy. The other limbs were sectioned in sagittal, dorsal or transverse planes. In the craniocaudal radiographic view, the lateral femoral condyle was broader than the medial femoral condyle. The femoral trochlea was asymmetrical. Subsequent multiplanar reconstruction revealed in the cranial view that the external surface of the patella was roughened, the medial trochlea ridge was larger than the lateral one, and the extensor fossa at the lateral condyle was next to the lateral ridge. The popliteal fossa was better visualized via the lateral view. Sagittal MRI images identified lateral and medial menisci, caudolateral and craniomedial bundles of cranial cruciate ligament, caudal cruciate ligament, patellar ligament and common extensor tendon. In conclusion, the marsh deer stifle presents some anatomical characteristics of the ovine stifle joint. 相似文献
7.
8.
PETER BÖTTCHER Dr med vet Diplomate ECVS MARKUS ZEISSLER DVM JOHANN MAIERL PhD Dr med vet VERA GREVEL Prof. Dr med vet Diplomate ECVS GERHARD OECHTERING Prof. Dr med vet Diplomate ECVAA 《Veterinary surgery : VS》2009,38(6):696-704
Objective— To characterize donor and recipient sites for autologous osteochondral transplantation in the canine stifle joint with respect to split-line pattern and cartilage thickness.
Study Design— In vitro study.
Sample Population— Stifle joints (n=30) of dogs >20 kg.
Methods— Collagen network orientation of the hyaline cartilage coverage of the distal femur was assessed using split-line technique (n=10). Cartilage thickness was measured radiographically on osteochondral plugs harvested at the abaxial and axial surfaces of the femoropatellar joint (n=15), the most proximal abaxial aspect of the medial condyle (CO; n=5) and at both femoral condyles (n=15).
Results— Cartilage within the femoropatellar joint and both femoral condyles had mostly transversely orientated pattern of split-lines. Abaxial to the femoropatellar joint split-lines were absent. All donor sites had significantly thinner cartilage than the medial condyle (CM). Only the distal trochlea had cartilage thickness comparable to the lateral condyle (CL). The thinnest cartilage was found abaxial to the femoropatellar joint followed by CO, which was ∼2–3 times thinner than the cartilage at both condyles.
Conclusions— None of the investigated donor sites provided transplants of comparable cartilage thickness to CM. Transplants from within the femoropatellar joint should be harvested in priority as they reach cartilage morphology comparable to CL.
Clinical Relevance— Adjusting for cartilage thickness and split-line pattern may improve long-term outcome after autologous osteochondral transplantation. But surface curvature and donor-site morbidity have to be considered as well when choosing the most suitable donor site. 相似文献
Study Design— In vitro study.
Sample Population— Stifle joints (n=30) of dogs >20 kg.
Methods— Collagen network orientation of the hyaline cartilage coverage of the distal femur was assessed using split-line technique (n=10). Cartilage thickness was measured radiographically on osteochondral plugs harvested at the abaxial and axial surfaces of the femoropatellar joint (n=15), the most proximal abaxial aspect of the medial condyle (CO; n=5) and at both femoral condyles (n=15).
Results— Cartilage within the femoropatellar joint and both femoral condyles had mostly transversely orientated pattern of split-lines. Abaxial to the femoropatellar joint split-lines were absent. All donor sites had significantly thinner cartilage than the medial condyle (CM). Only the distal trochlea had cartilage thickness comparable to the lateral condyle (CL). The thinnest cartilage was found abaxial to the femoropatellar joint followed by CO, which was ∼2–3 times thinner than the cartilage at both condyles.
Conclusions— None of the investigated donor sites provided transplants of comparable cartilage thickness to CM. Transplants from within the femoropatellar joint should be harvested in priority as they reach cartilage morphology comparable to CL.
Clinical Relevance— Adjusting for cartilage thickness and split-line pattern may improve long-term outcome after autologous osteochondral transplantation. But surface curvature and donor-site morbidity have to be considered as well when choosing the most suitable donor site. 相似文献
9.
ERIC MONNET DVM MS Diplomate ACVS PETER D. SCHWARZ DVM MS Diplomate ACVS BARBARA POWERS DVM PhD Diplomate ACVP 《Veterinary surgery : VS》1995,24(6):465-475
Popliteal tendon transposition was performed in five dogs with surgically induced cranial cruciate ligament rupture. After a lateral approach to the stifle joint, the popliteal tendon was severed distal to the sesamoid bone and transposed cranially onto the tibial crest to mimic the sagittal orientation of the cranial cruciate ligament. The origin of the popliteal tendon on the lateral femoral condyle was preserved. Lameness was not clinically detectable 2 months after surgery. At 6 months postoperatively, there was minimal radiographic and histopathologic evidence of degenerative joint disease in the stifle joints that had underwent surgery. There was no gross or microscopic evidence of meniscal damage found at necropsy 6 months after surgery. Biome-chanical studies are warranted before recommending the procedure. 相似文献
10.
11.
Evaluation of Lameness Associated with Arthroscopy and Arthrotomy of the Normal Canine Cubital Joint
Loretta J. Bubenik DVM MS Spencer A. Johnson VMD DACVS Mark M. Smith VMD DACVS DAVDC Rick D. Howard DVM PhD DACVS Richard V. Broadstone DVM PhD DACVA 《Veterinary surgery : VS》2002,31(1):23-31
OBJECTIVE: To evaluate gait, range of motion (ROM), and lameness in normal dogs after arthroscopy or arthrotomy of the cubital joint. STUDY DESIGN: Experimental study. ANIMALS: Fourteen mature, healthy dogs. METHODS: Dogs were randomly assigned to treatment groups. Seven underwent arthrotomy and 7 underwent arthroscopy of the left cubital joint. Dogs were evaluated using kinetic gait assessment, subjective evaluation scores, and cubital joint ROM. Evaluations were performed before and on days 2, 4, 7, 15, 22, and 29 after surgery. Radiographs made before and after the surgical procedures were evaluated. RESULTS: Significant differences in peak vertical force and vertical impulse force were not observed between surgery groups (P =.88 and.49, respectively). Joint ROM was not significantly different between groups (P =.09 for flexion and.91 for extension). For all dogs, joint ROM and radiographic evaluations remained normal throughout the study period. Significant differences in subjective lameness scores, weight bearing, or pain were not observed between groups (P >/ or =.19 for all variables). CONCLUSIONS: In this study population, significant differences between dogs undergoing arthroscopy or arthrotomy of the cubital joint with respect to postoperative pain, weight bearing, joint ROM, or temporal improvement of ground reaction forces were not observed. CLINICAL RELEVANCE: The results of this study suggest that postoperative morbidity should not be a factor when making a decision to perform either arthroscopy or arthrotomy for exploration of the medial compartment of the canine cubital joint. 相似文献
12.
Mechanical Comparison of Loop and Crimp Configurations for Extracapsular Stabilization of the Cranial Cruciate Ligament‐Deficient Stifle 下载免费PDF全文
Josep Aisa DVM Ignacio Calvo DVM Diplomate ECVS Conor T. Buckley BA BAIPhD Barbara M. Kirby DVMMS Diplomate ACVS ECVS 《Veterinary surgery : VS》2015,44(1):50-58
13.
RICHARD BURGESS BVM&S STEVE ELDER BS MS PhD RON McLAUGHLIN DVM DVSc Diplomate ACVS PETER CONSTABLE BVSc MS PhD Diplomate ACVIM 《Veterinary surgery : VS》2010,39(2):208-215
Objective— To compare biomechanical properties of 3 new generation polyethylene sutures (FiberTape [FT], FiberWire [FW], and OrthoFiber [OF]) with nylon leader line (NL) for use during extraarticular fixation of cranial cruciate deficient stifles. Study Design— In vitro biomechanical testing of suture loops under monotonic tensile and cyclical loading until failure. Sample Population— Constructs of FT, FW, OF, and NL. Methods— Twenty loops of each of 12 combinations of fixation and suture had monotonic tensile and cyclical loading. Two knotting techniques (square knot [SQ], slip knot [SL]) and a crimp clamp (CR) system were evaluated. Elongation, stiffness, and strength of constructs was tested. The main effects of group, loop material, and their interaction were evaluated. Results— Knotted FT, FW, and OF had less elongation than knotted NL under monotonic tensile and cyclical loading. Under monotonic tensile loading, knotted FT and OF were stiffer than knotted NL. CR FT, CR FW, and CR OF were stiffer than CR NL and CR FT, CR FW, and CR OF were stiffer than knotted FT, FW, and OF. FW and OF knotted loops were weaker than knotted NL. CR FT was stronger than CR NL. CR FT and CR OF were weaker than knotted FT and OF. Conclusions— Polyethylene sutures are stronger, stiffer and elongate less than nylon leader. Crimping suture alters the biomechanical properties of the loop. Clinical Relevance— FW, FT, and OF may perform better in reconstructive procedures, where increased strength and stiffness are considered to be beneficial. 相似文献
14.
Ogawa Mizuki Ishizaka Mio Akabane Ryota Sakatani Atsushi Nagakawa Masayoshi Miyakawa Hirosumi Miyagawa Yuichi Takemura Naoyuki 《Veterinary research communications》2020,44(2):73-81
Veterinary Research Communications - Sildenafil improves autonomic dysfunction caused by pulmonary hypertension (PH) in humans, but its effect is unknown in dogs with PH. This prospective study... 相似文献
15.
16.
K. Jane Wardrop DVM MS Russell L. Tucker Kristen Mugnai 《Journal of veterinary internal medicine / American College of Veterinary Internal Medicine》1997,11(1):5-8
An additive solution for the storage of red blood cells was evaluated for use in dogs. Blood collected from 6 dogs was processed into packed red blood cells and stored for 35 days in the additive solution Nutricel (Miles, Inc, Pharmaceutical Division, West Haven, CT). Packed red blood cells stored in citrate-phosphate-dextrose-adenine (CPDA-1; Fenwal Laboratories, Baxter Health Care Corp, Deerfield, IL) also were evaluated for comparison. Red blood cell 2,3-diphosphoglycerate (2,3-DPG) concentration, adenosine triphosphate (ATP) concentration, percentage hemolysis, and pH were determined. The red blood cell post-transfusion viability (PTV) after 35 days of storage was assessed with both single-labeled chromium 51 (51Cr) and double-labeled technetium 99m/chromium 51 (99mTc/51Cr) techniques. Mean ATP concentration and percentage hemolysis of the cells stored in Nutricel were 1.1 μmol/g hemoglobin (Hb) and 0.28% respectively and did not differ significantly (P < .05) from the values of 1.0 μmol/g Hb and 0.33% from the CPDA-1-stored red blood cells. The mean pH of red blood cells stored in Nutricel was 6.19, which was significantly lower than the pH of 6.47 for cells stored in CPDA-1. The mean 2,3-DPG concentration of red blood cells stored in Nutricel was significantly higher at 10.1 μmol/g Hb than the 2,3-DPG concentration of 3.4μmol/g Hb for cells stored in CPDA-1. The mean PTV of canine red blood cells stored in Nutricel for 35 days was 85% with 51Cr and 90% with 99mTc/51Cr. This was significantly higher than the mean PTVs of 38% and 36% for the CPDA-1 stored cells as assessed with 51Cr and 99mTc/51Cr techniques, respectively. It was concluded that 35-day-old canine red blood cells stored in Nutricel are of acceptable quality for transfusion purposes. 相似文献
17.
The evaluation of progesterone (P4) concentration is a valuable tool in assessing physiological reproductive events and reproductive disorders in bitches. A reliable and rapid (preferable, point of care) determination of P4 is advisable in most cases. Aims of this study were to evaluate a fluorescence enzyme immunoassay (FEIA) for canine serum P4 concentration by (i) the agreement with liquid chromatography–tandem mass spectrometry (LC/MS/MS), (ii) the association with vaginal cytology and (iii) the accuracy in the prediction of the parturition date calculated from the estimated day of ovulation. Serum samples were collected from client‐owned bitches presented between 2011 and 2014 for the evaluation of their oestrous cycle, pregnancy or reproductive disorders. The agreement between FEIA and LC/MS/MS, evaluated on 19 samples, was statistically significant (R2 = 95.7%, p < 0.001), although FEIA showed significantly higher values than LC/MS/MS (p < 0.05). In the different phases of oestrous cycle, as determined by vaginal cytology, P4 concentrations (by FEIA) were statistically different (p < 0.05): anoestrus (n = 7) 0.38 ± 0.14 ng/ml, proestrus (n = 14) 1.04 ± 0.67 ng/ml and oestrus (n = 72) 6.8 ± 7.26 ng/ml. Mean pregnancy length from the estimated day of ovulation was 62.9 ± 1.8 days. In 13 of 22 (59.1%), 19 of 22 (86.3%) and 21 of 22 (95.5%) bitches pregnancy lasted 63 ± 1, 63 ± 2 and 63 ± 3 days, respectively. Three pregnancies were outside the 61–65 days range (60, 60 and 67 days). In conclusion, the FEIA method employed can be considered reliable and, in association with vaginal cytology, effective in evaluating the canine oestrous cycle. 相似文献
18.
Biomechanical Comparison of Locking Compression Plate versus Positive Profile Pins and Polymethylmethacrylate for Stabilization of the Canine Lumbar Vertebrae 下载免费PDF全文
Beverly K. Sturges Amy S. Kapatkin Tanya C. Garcia Cona Anwer Shimpei Fukuda Peta L. Hitchens Tristan Wisner Kei Hayashi Susan M. Stover 《Veterinary surgery : VS》2016,45(3):309-318
19.
20.
M. Di Tommaso G. Aste F. Rocconi C. Guglielmini A. Boari 《Journal of veterinary internal medicine / American College of Veterinary Internal Medicine》2009,23(3):466-471
Background: The diagnosis of canine diabetic ketoacidosis (DKA) usually is based on measurement of urinary acetoacetate (ketonuria). In humans, this test is less sensitive and specific than blood 3-β-hydroxybutyrate (ketonemia) evaluation.
Hypothesis: Ketonemia measurement using a portable meter is more accurate than ketonuria determination with a dipstick to diagnose canine DKA.
Animals: Seventy-two client-owned diabetic dogs with ketonemia, ketonuria, or both.
Methods: Prospective observational study. Based on blood bicarbonate concentration and anion gap, dogs were divided into 2 groups: patients with DKA ( n = 25); patients with diabetic ketosis ( n = 47). Sensitivity, specificity, and positive and negative likelihood ratio (LR) at different cut-off points were determined for both ketonemia and ketonuria. Receiver operating characteristic (ROC) analysis was used to assess the accuracy of each diagnostic test to diagnose DKA.
Results: With regard to ketonemia, cut-off values of 2.3 and 4.3 mmol/L revealed 100% sensitivity and 100% specificity, respectively, whereas cut-off values of 2.8 and 3.5 mmol/L showed a −LR of 0.05 and a + LR of 13.16, respectively. With regard to ketonuria, a cut-off value of 1+ revealed 92% sensitivity, 40% specificity, and −LR of 0.20, whereas a cut-off value of 3+ revealed 44% sensitivity, 94% specificity, and +LR of 6.89. The areas under the ROC curves for the ketonemia and ketonuria tests were significantly different (0.97 and 0.81, respectively, P = .003).
Conclusions and Clinical Importance: Measurement of ketonemia is accurate and more effective than measurement of ketonuria to diagnose canine DKA. 相似文献
Hypothesis: Ketonemia measurement using a portable meter is more accurate than ketonuria determination with a dipstick to diagnose canine DKA.
Animals: Seventy-two client-owned diabetic dogs with ketonemia, ketonuria, or both.
Methods: Prospective observational study. Based on blood bicarbonate concentration and anion gap, dogs were divided into 2 groups: patients with DKA ( n = 25); patients with diabetic ketosis ( n = 47). Sensitivity, specificity, and positive and negative likelihood ratio (LR) at different cut-off points were determined for both ketonemia and ketonuria. Receiver operating characteristic (ROC) analysis was used to assess the accuracy of each diagnostic test to diagnose DKA.
Results: With regard to ketonemia, cut-off values of 2.3 and 4.3 mmol/L revealed 100% sensitivity and 100% specificity, respectively, whereas cut-off values of 2.8 and 3.5 mmol/L showed a −LR of 0.05 and a + LR of 13.16, respectively. With regard to ketonuria, a cut-off value of 1+ revealed 92% sensitivity, 40% specificity, and −LR of 0.20, whereas a cut-off value of 3+ revealed 44% sensitivity, 94% specificity, and +LR of 6.89. The areas under the ROC curves for the ketonemia and ketonuria tests were significantly different (0.97 and 0.81, respectively, P = .003).
Conclusions and Clinical Importance: Measurement of ketonemia is accurate and more effective than measurement of ketonuria to diagnose canine DKA. 相似文献