首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 12 毫秒
1.
This study was undertaken to evaluate the effect of 3 different doses of epidurally administered morphine sulphate on the minimum alveolar concentration (MAC) of isoflurane in healthy cats. Five 4-year-old, spayed female cats weighing 4.7 ± 0.8 kg were allocated randomly to receive one of 3 doses of morphine on each study day. The 3 doses of morphine were 0.05, 0.1 and 0.2 mg/kg bwt and each cat was studied 3 times so that each cat received all doses. On each study day, cats were anaesthetised with isoflurane and instrumented. The MAC of isoflurane was determined in triplicate and morphine sulphate was administered via an epidural catheter chronically implanted prior to the study. Maximum MAC reduction was determined over the following 2 h. At the end of the study cats were allowed to recover. There was a significant reduction in MAC of isoflurane, with all doses of epidural morphine (P<0.05). The maximum reduction in MAC of isoflurane after 0.05 mg/kg bwt, 0.10 mg/kg bwt and 0.20 mg/kg bwt morphine was 21.4 ± 9.796, 30.8 ± 9.696, and 30.2 ± 6.8%, respectively, with no significant difference between doses. Systolic, mean and diastolic blood pressure, heart rate, respiratory rate and arterial pH decreased significantly whereas arterial carbon dioxide tension increased significantly after morphine administration (P<0.05). The means for all variables returned to pre-morphine values when the end-tidal isoflurane concentration was reduced to the new MAC point. In conclusion, epidural morphine decreased the concentration of isoflurane required to prevent movement in response to noxious mechanical stimulation to the tail base. A similar effect may be seen clinically allowing lower doses of isoflurane to be used to provide surgical anaesthesia for procedures involving the hind limbs, pelvis and tail.  相似文献   

2.
OBJECTIVE: To determine whether opioids with varying interactions at receptors induce a reduction in minimum alveolar concentration (MAC) of isoflurane in cats. ANIMALS: 12 healthy, female, spayed cats. PROCEDURE: Cats were anesthetized with isoflurane and instrumented to allow collection of arterial blood and measurement of arterial blood pressure. Each drug was studied separately, and for each drug cats were randomly allocated to receive 2 doses. The drugs studied were morphine (0.1 or 1.0 mg/kg), butorphanol (0.08 or 0.8 mg/kg), buprenorphine (0.005 and 0.05 mg/kg), and U50488H (0.02 and 0.2 mg/kg). All drugs were diluted in 5 ml of saline (0.9% NaCl) solution and infused IV for 5 minutes. The MAC of isoflurane was determined in triplicate, the drug administered, and the MAC of isoflurane redetermined for a period of 3 hours. RESULTS: All drugs had a significant effect on MAC over time. With morphine only, the effect on MAC over time was different between doses. The greatest mean (+/- SD) reductions in MAC of isoflurane in response to morphine, butorphanol, buprenorphine, and U50488H administration were 28 +/- 9, 19 +/- 3, 14 +/- 7, and 11 +/- 7%, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: Morphine (1.0 mg/kg) and butorphanol (0.08 and 0.8 mg/kg) induced significant reductions in MAC of isoflurane that were considered clinically important. Although significant, reductions in MAC of isoflurane induced by morphine (0.1 mg/kg), buprenorphine (0.005 and 0.05 mg/kg), and U50488H (0.02 and 0.2 mg/kg) were not considered clinically relevant because they fell within the error of the measurement technique. Administration of morphine or butorphanol decreases the need for potent inhalant anesthetics in cats and could potentially be beneficial in combination with inhalants.  相似文献   

3.
Objective-To evaluate the effects of epidural administration of 3 doses of dexmedetomidine on isoflurane minimum alveolar concentration (MAC) and characterize changes in bispectral index (BIS) induced by nociceptive stimulation used for MAC determination in dogs. Animals-6 adult dogs. Procedures-Isoflurane-anesthetized dogs received physiologic saline (0.9% NaCl) solution (control treatment) or dexmedetomidine (1.5 [DEX1.5], 3.0 [DEX3], or 6.0 [DEX6] mug/kg) epidurally in a crossover study. Isoflurane MAC (determined by use of electrical nociceptive stimulation of the hind limb) was targeted to be accomplished at 2 and 4.5 hours. Changes in BIS attributable to nociceptive stimulation and cardiopulmonary data were recorded at each MAC determination. Results-With the control treatment, mean +/- SD MAC values did not change over time (1.57 +/- 0.23% and 1.55 +/- 0.25% at 2 and 4.5 hours, respectively). Compared with the control treatment, MAC was significantly lower at 2 hours (13% reduction) but not at 4.5 hours (7% reduction) in DEX1.5-treated dogs and significantly lower at 2 hours (29% reduction) and 4.5 hours (13% reduction) in DEX3-treated dogs. The DEX6 treatment yielded the greatest MAC reduction (31% and 22% at 2 and 4.5 hours, respectively). During all treatments, noxious stimulation increased BIS; but changes in BIS were correlated with increases in electromyographic activity. Conclusions and Clinical Relevance-In dogs, epidural administration of dexmedetomidine resulted in dose-dependent decreases in isoflurane MAC and that effect decreased over time. Changes in BIS during MAC determinations may not represent increased awareness because of the possible interference of electromyographic activity.  相似文献   

4.
Lidocaine has been reported to decrease the minimum alveolar concentration (MAC) of inhalation anesthetics in several species and has been used clinically to reduce the requirements for other anesthetic drugs. This study examined the effects of intravenous lidocaine on isoflurane MAC in cats. Six cats were studied. In experiment 1, the MAC of isoflurane was determined. An intravenous bolus of lidocaine 2 mg kg–1 was then administrated and venous plasma lidocaine concentrations measured to determine pharmacokinetic values. In experiment 2, lidocaine was administered to achieve target plasma concentrations between 1 and 11 μg mL–1 and the MAC of isoflurane was determined in triplicate at each lidocaine plasma concentration, using the tail‐clamp method. End‐tidal isoflurane concentration was determined using a calibrated infrared analyzer. Systolic blood pressure (Doppler), SpO2 and end‐tidal PCO2 (calibrated Raman spectrometer) were measured prior to each MAC determination. Body temperature was maintained between 38.5 and 39.5 °C by supplying external heat as needed. MAC values at the different lidocaine plasma concentrations were analyzed by a repeated measures ANOVA , using the Huynh–Feldt correction. The MAC of isoflurane in these cats was 2.21 ± 0.17. For the target concentrations of 1, 3, 5, 7, 9, and 11 μg mL–1, the actual lidocaine plasma concentrations was 1.06 ± 0.12, 2.83 ±0.39, 4.93 ± 0.64, 6.86 ± 0.97, 8.86 ± 2.10, and 9.84 ± 1.34 μg mL–1, respectively. At these target concentrations, the MAC of isoflurane was 2.14 ± 0.14, 1.88 ± 0.18, 1.66 ± 0.16, 1.47 ±0.13, 1.33 ± 0.23, and 1.06 ± 0.19%, respectively. Lidocaine, at target plasma concentrations of 1, 3, 5, 7, 9, and 11 μg mL–1, linearly decreased isoflurane MAC by –6 to 6, 7 to 28, 19 to 35, 28 to 45, 29 to 53, and 44 to 59%, respectively. Lidocaine significantly dose‐dependently and linearly decreases the requirements for isoflurane in cats. No ceiling effect was observed within the range of plasma concentrations studied.  相似文献   

5.
ObjectiveTo determine the effect of intravenous (IV) buprenorphine on the isoflurane (ISO) minimum alveolar concentration (ISOMAC) in dogs.Study designRandomized, crossover, design.AnimalsSix healthy, adult (2–3 years old), intact dogs (two males and four females) weighing 7.4–11.0 kg.MethodsEach dog was studied on three occasions, 1 week apart, and baseline ISOMAC (MACB) was determined on each occasion. ISOMAC was defined as the mean of the end-tidal ISO concentrations that prevented and allowed purposeful movement in response to a noxious stimulus. After MACB determination, dogs were randomly given buprenorphine (BUP) at either 0.01, 0.05 or 0.1 mg kg?1 IV, and ISOMAC was determined at two time periods after BUP administration. The first post-treatment determination (MACT1) was initiated 45 minutes after BUP administration and the second determination (MACT2) was initiated 4 hours after BUP administration. MAC values were determined in duplicate and the mean values were used for statistical analysis.ResultsIsoflurane minimum alveolar concentration was decreased at 141 minutes (the time of MACT1 determination) by 25%, 35%, and 27% after administration of BUP at 0.01, 0.05, and 0.1 mg kg?1, respectively (p ≤ 0.05). The MAC reductions were not statistically different among doses. The reductions in ISOMAC at 342 minutes (the time of MACT2 determination) ranged from 13 to 16%, and were not statistically different among doses.Conclusions and clinical significanceBuprenorphine at 0.01, 0.05, and 0.1 mg kg?1 significantly decreased ISOMAC in dogs at 141 minutes but not at 342 minutes. When using BUP for MAC reduction re-dosing may be required for procedures of long duration, and there may be no advantage to using the 0.1 mg kg?1 dose.  相似文献   

6.
Different structurally related phenylpiperidine opioids exhibit different isoflurane-sparing effects in cats. Because minimum alveolar concentration (MAC) in cats is affected only by very high plasma concentrations of some phenylpiperidine opioids, we hypothesized these effects are caused by actions on nonopioid receptors. Using a prospective, randomized, crossover design, six cats were anesthetized with isoflurane, intubated, ventilated, and instrumented. Isoflurane MAC was measured in triplicate using a tail-clamp and bracketing technique. A computer-controlled intravenous infusion using prior pharmacokinetic models targeted plasma concentrations of 60 ng/ml fentanyl, 10 ng/ml sufentanil, or 500 ng/ml alfentanil, and isoflurane MAC was measured in duplicate. Next, naltrexone 0.6 mg/kg was administered to cats hourly during the opioid infusion, and isoflurane MAC was measured in duplicate. Blood was collected during MAC determinations to measure opioid concentrations. Responses were analyzed using repeated measures ANOVA with significance at p < .05. Alfentanil and sufentanil decreased isoflurane MAC by 16.4% and 6.4%, respectively, and these effects were completely reversed by naltrexone. Fentanyl had no significant effect on isoflurane MAC. Alfentanil and sufentanil modestly reduce isoflurane MAC via agonist effects on opioid receptors. However, these effects are too small to justify clinical use of phenylpiperidine opioids as single agents to reduce MAC in cats.  相似文献   

7.
This study reports the effects of dexmedetomidine on the minimum alveolar concentration of isoflurane (MAC(iso) ) in cats. Six healthy adult female cats were used. MAC(iso) and dexmedetomidine pharmacokinetics had previously been determined in each individual. Cats were anesthetized with isoflurane in oxygen. Dexmedetomidine was administered intravenously using target-controlled infusions to maintain plasma concentrations of 0.16, 0.31, 0.63, 1.25, 2.5, 5, 10, and 20 ng/mL. MAC(iso) was determined in triplicate at each target plasma dexmedetomidine concentration. Blood samples were collected and analyzed for dexmedetomidine concentration. The following model was fitted to the concentration-effect data: [Formula in text] where MAC(iso.c) is MAC(iso) at plasma dexmedetomidine concentration C, MAC(iso.0) is MAC(iso) in the absence of dexmedetomidine, I(max) is the maximum possible reduction in MAC(iso), and IC(50) is the plasma dexmedetomidine concentration producing 50% of I(max). Mean ± SE MAC(iso.0), determined in a previous study conducted under conditions identical to those in this study, was 2.07 ± 0.04. Weighted mean ± SE I(max), and IC(50) estimated by the model were 1.76 ± 0.07%, and 1.05 ± 0.08 ng/mL, respectively. Dexmedetomidine decreased MAC(iso) in a concentration-dependent manner. The lowest MAC(iso) predicted by the model was 0.38 ± 0.08%, illustrating that dexmedetomidine alone is not expected to result in immobility in response to noxious stimulation in cats at any plasma concentration.  相似文献   

8.
ObjectiveTo test whether naltrexone, an opioid receptor antagonist, affects the minimum alveolar concentration (MAC) of isoflurane in cats, a species that is relatively resistant to the general anesthetic sparing effects of most opioids.Study designRandomized, crossover, placebo-controlled, blinded experimental design.AnimalsSix healthy adult cats weighing 4.9 ± 0.7 kg.MethodsThe cats were studied twice. In the first study, baseline isoflurane MAC was measured in duplicate. The drug (saline control or 0.6 mg kg?1 naltrexone) was administered IV every 40–60 minutes, and isoflurane MAC was re-measured. In the second study, cats received the second drug treatment using identical methods 2 weeks later.ResultsIsoflurane MAC was 2.03 ± 0.12% and was unchanged from baseline following saline or naltrexone administration.Conclusion and clinical relevanceMinimum alveolar concentration was unaffected by naltrexone. Because MAC in cats is unaffected by at least some mu-opioid agonists and antagonists, spinal neurons that are directly modulated by mu-opioid receptors in this species cannot be the neuroanatomic sites responsible for immobility from inhaled anesthetics.  相似文献   

9.
OBJECTIVES: To determine the minimum alveolar concentration (MAC) of isoflurane during the infusion of ketamine. STUDY DESIGN: Prospective, experimental trial. ANIMALS: Twelve adult spayed female cats weighing 5.1 +/- 0.9 kg. METHODS: Six cats were anesthetized with isoflurane in oxygen, intubated and attached to a circle-breathing system with mechanical ventilation. Catheters were placed in a peripheral vein for the infusion of fluids and ketamine, and the jugular vein for blood sampling for the measurement of ketamine concentrations. An arterial catheter was placed to allow blood pressure measurement and sampling for the measurement of PaCO2, PaO2 and pH. PaCO2 was maintained between 29 and 41 mmHg (3.9-5.5 kPa) and body temperature was kept between 37.8 and 39.3 degrees C. Following instrumentation, the MAC of isoflurane was determined in triplicate using a tail clamp method. A loading dose (2 mg kg(-1) over 5 minutes) and an infusion (23 microg kg(-1) minute(-1)) of ketamine was started and MAC was redetermined starting 30 minutes later. Two further loading doses and infusions were used, 2 mg kg(-1) and 6 mg kg(-1) with 46 and 115 microg kg(-1) minute(-1), respectively and MAC was redetermined. Cardiopulmonary measurements were taken before application of the noxious stimulus. The second group of six cats was used for the measurement of steady state plasma ketamine concentrations at each of the three infusion rates used in the initial study and the appropriate MAC value determined from the first study. RESULTS: The MAC decreased by 45 +/- 17%, 63 +/- 18%, and 75 +/- 17% at the infusion rates of 23, 46, and 115 microg kg(-1) minute(-1). These infusion rates corresponded to ketamine plasma concentrations of 1.75 +/- 0.21, 2.69 +/- 0.40, and 5.36 +/- 1.19 microg mL(-1). Arterial blood pressure and heart rate increased significantly with ketamine. Recovery was protracted. CONCLUSIONS AND CLINICAL RELEVANCE: The MAC of isoflurane was significantly decreased by an infusion of ketamine and this was accompanied by an increase in heart rate and blood pressure. Because of the prolonged recovery in our cats, further work needs to be performed before using this in patients.  相似文献   

10.
OBJECTIVE: To determine the effect of morphine and flunixin meglumine on isoflurane (ISO) minimum alveolar concentration (MAC) in goats. STUDY DESIGN: Prospective, randomized experimental study. ANIMALS: Five adult, wether goats from 1 to 3 years in age, and weighing 24-65 kg. METHODS: Anesthesia was induced using ISO, which was delivered via a mask. Goats were intubated and ventilated to maintain an end-tidal carbon dioxide concentration between 25 and 30 mm Hg (3.3-4 kPa). End-tidal ISO concentration was measured using an infrared analyzer. The baseline ISO MAC that prevented purposeful movement in response to clamping a claw was determined. Following baseline MAC determination, each goat received one of the following four treatments intravenously (IV): morphine (2 mg kg(-1)), flunixin (1.5 mg kg(-1)), flunixin (1.5 mg kg(-1)) plus morphine (2 mg kg(-1)) or saline, and the MAC was re-determined. Goats were studied at weekly intervals, and each goat received each treatment in a randomized fashion. RESULTS: The baseline ISO MAC for the control treatment was 1.43%. Morphine reduced the MAC by 29.7%. Flunixin did not significantly decrease the MAC nor did it potentiate the effect of morphine on MAC. The quality of recovery was good in all cases. CONCLUSIONS: Morphine (2 mg kg(-1), IV) significantly reduced the ISO MAC in goats and did not adversely affect the quality of recovery. CLINICAL RELEVANCE: The use of morphine, at the dose studied, in association with ISO anesthesia, will allow a clinically significant reduction in the concentration of ISO required to maintain general anesthesia in goats.  相似文献   

11.
OBJECTIVE: To determine the effect of two doses of fentanyl, administered transdermally, on the minimum alveolar concentration (MAC) of isoflurane in cats. STUDY DESIGN: Prospective, randomized study. ANIMALS: Five healthy, spayed, female cats. METHODS: Each cat was studied thrice with at least 2 weeks between each study. In study 1, the baseline isoflurane MAC was determined in triplicate for each cat. In studies 2 and 3, isoflurane MAC was determined 24 hours after placement of either a 25 or 50 microg hour(-1) fentanyl patch. In each MAC study, cats were instrumented to allow collection of arterial blood and measurement of arterial blood pressure. Twenty-four hours prior to studies 2 and 3, a catheter was placed and secured in the jugular vein and either a 25 or 50 microg hour(-1) fentanyl patch was placed in random order on the left thorax. Blood samples for plasma fentanyl determination were collected prior to patch placement and at regular intervals up to 144 hours. After determination of MAC in studies 2 and 3, naloxone was administered as a bolus dose (0.1 mg kg(-1)) followed by an infusion (1 mg kg(-1) hour(-1)) and MAC redetermined. RESULTS: The baseline isoflurane MAC was 1.51 +/- 0.21% (mean +/- SD). Fentanyl (25 and 50 micro g hour(-1)) administered transdermally significantly reduced MAC to 1.25 +/- 0.26 and 1.22 +/- 0.16%, respectively. These MAC reductions were not significantly different from each other. Isoflurane MAC determined during administration of fentanyl 25 micro g hour(-1) and naloxone (1.44 +/- 0.16%) and fentanyl 50 micro g hour(-1) and naloxone (1.51 +/- 0.19%) was not significantly different from baseline MAC (1.51 +/- 0.21%). CONCLUSIONS AND CLINICAL RELEVANCE: Fentanyl patches are placed to provide long-lasting analgesia. In order to be effective postoperatively, fentanyl patches must be placed prior to surgery. Plasma fentanyl concentrations achieved intraoperatively decrease the need for potent inhalant anesthetics in cats.  相似文献   

12.
ObjectiveTo determine the effect of butorphanol, administered by intravenous (IV) infusion, on the minimum alveolar concentration of isoflurane (MACISO) in cats and to examine the dosage dependence of this effect.Study designRandomized, placebo-controlled, crossover experimental study.AnimalsA group of six healthy adult male neutered cats.MethodsCats were anesthetized with isoflurane in oxygen. A venous catheter was placed for fluid and drug administration, and an arterial catheter was placed for measurement of arterial pressure and blood sampling. Four treatments were administered at random with at least 2 week interval between treatments: saline (control), butorphanol low dosage (treatment LD; 0.25 mg kg–1 IV bolus followed by 85 μg kg–1 minute–1 for 20 minutes, then 43 μg kg–1 minute–1 for 40 minutes, then 19 μg kg–1 minute–1), medium dosage (treatment MD, double the dosages in LD) and high dosage (treatment HD, quadruple the dosages in LD). MACISO was determined in duplicate using the bracketing technique and tail clamping. Pulse rate, arterial pressure, hemoglobin oxygen saturation, end-tidal partial pressure of carbon dioxide and arterial blood gas and pH were measured.ResultsButorphanol reduced MACISO in a dosage-dependent manner, by 23 ± 8%, 37 ± 12% and 68 ± 10% (mean ± standard deviation) in treatments LD, MD and HD, respectively. The main cardiopulmonary effect observed was a decrease in pulse rate, significant in treatment HD compared with control.Conclusions and clinical relevanceButorphanol caused a dosage-dependent MACISO reduction in cats. IV infusion of butorphanol may be of interest for partial IV anesthesia in cats.  相似文献   

13.
14.
ObjectiveThe purpose of this systematic review is to summarize the results of studies which have determined the minimum alveolar concentration (MAC) of isoflurane and sevoflurane in domestic cats.Study DesignSystematic review.AnimalsCats.Methods usedA comprehensive search of research literature was performed without language restriction. The search utilized the Pubmed, Google Scholar, and CAB Abstracts electronic databases using a combination of free text terms ‘Minimum alveolar concentration’, ‘sevoflurane’, ‘isoflurane’, ‘anesthetic’, ‘cat’, ‘cats’ or ‘feline’. The search was conducted from November 2010 to June 2012.ResultsThe MAC for isoflurane ranged from 1.20 ± 0.13% to 2.22 ± 0.35% and the MAC for sevoflurane ranged from 2.5 ± 0.2% to 3.95 ± 0.33%. The average MAC for isoflurane was 1.71 ± 0.07% and for sevoflurane was 3.08 ± 0.4%.Conclusions &; Clinical RelevanceThe average MAC for isoflurane was 1.71 ± 0.07% and for sevoflurane was 3.08 ± 0.4%. Methodology differed among studies, and particular attention should be paid in the future to appropriate reporting of methods to allow sound conclusions to be made from the results.  相似文献   

15.
ObjectiveTo investigate the effects of methadone on the minimum alveolar concentration of isoflurane (ISOMAC) in dogs.Study designProspective, randomized cross-over experimental study.AnimalsSix adult mongrel dogs, four males and two females, weighing 22.8 ± 6.6 kg.MethodsAnimals were anesthetized with isoflurane and mechanically ventilated on three separate days, at least 1 week apart. Core temperature was maintained between 37.5 and 38.5 °C during ISOMAC determinations. On each study day, ISOMAC was determined using electrical stimulation of the antebrachium (50 V, 50 Hz, 10 mseconds) at 2.5 and 5 hours after intravenous injection of physiological saline (control) or one of two doses of methadone (0.5 or 1.0 mg kg?1).ResultsMean (±SD) ISOMAC in the control treatment was 1.19 ± 0.15% and 1.18 ± 0.15% at 2.5 and 5 hours, respectively. The 1.0 mg kg?1 dose of methadone reduced ISOMAC by 48% (2.5 hours) and by 30% (5 hours), whereas the 0.5 mg kg?1 dose caused smaller reductions in ISOMAC (35% and 15% reductions at 2.5 and 5 hours, respectively). Both doses of methadone decreased heart rate (HR), but the 1.0 mg kg?1 dose was associated with greater negative chronotropic actions (HR 37% lower than control) and mild metabolic acidosis at 2.5 hours. Mean arterial pressure increased in the MET1.0 treatment (13% higher than control) at 2.5 hours.Conclusions and clinical relevanceMethadone reduces ISOMAC in a dose-related fashion and this effect is lessened over time. Although the isoflurane sparing effect of the 0.5 mg kg?1 dose of methadone was smaller in comparison to the 1.0 mg kg?1 dose, the lower dose is recommended for clinical use because it results in less evidence of cardiovascular impairment.  相似文献   

16.
OBJECTIVE: To determine the effect of IV administration of perzinfotel on the minimum alveolar concentration (MAC) of isoflurane in dogs. Animals-6 healthy sexually intact male Beagles. PROCEDURES: Dogs were instrumented with a telemetry device that permitted continuous monitoring of heart rate, arterial blood pressure, and body temperature. Dogs were anesthetized with propofol (4 to 6 mg/kg, IV) and isoflurane for 30 minutes before determination of MAC of isoflurane. Isoflurane MAC values were determined 4 times, separated by a minimum of 7 days, before and after IV administration of perzinfotel (0 [control], 5, 10, and 20 mg/kg). Bispectral index and percentage hemoglobin saturation with oxygen (SpO(2)) were monitored throughout anesthesia. RESULTS: Isoflurane MAC was 1.32 +/- 0.14%. Intravenous administration of perzinfotel at 0, 5, 10, and 20 mg/kg decreased isoflurane MAC by 0%, 24%, 30%, and 47%, respectively. Perzinfotel significantly decreased isoflurane MAC values, compared with baseline and control values. The bispectral index typically increased with higher doses of perzinfotel and lower isoflurane concentrations, but not significantly. Heart rate, body temperature, and SpO(2) did not change, but systolic, mean, and diastolic arterial blood pressures significantly increased with decreases in isoflurane MAC after administration of perzinfotel at 10 and 20 mg/kg, compared with 0 and 5 mg/kg. CONCLUSIONS AND CLINICAL RELEVANCE: IV administration of perzinfotel decreased isoflurane MAC values. Improved hemodynamics were associated with decreases in isoflurane concentration.  相似文献   

17.
18.
OBJECTIVE: To determine the effects of adenosine infusion on the minimum alveolar concentration (MAC) of isoflurane in dogs. STUDY DESIGN: Prospective, randomized crossover study. ANIMALS: Seven adult male and female Beagles weighing 10.9 (7.5, 13.6) kg [median (minimum, maximum)]. METHODS: Each dog was anesthetized with isoflurane in oxygen and randomly assigned to receive either an intravenous (IV) adenosine (0.3 mg kg(-1) minute(-1)) or saline (6 mL kg(-1) hour(-1) IV) infusion. After an interval of 7 days or more, each dog was re-anesthetized and treated with the alternative infusion. Using a tail-clamp technique, MAC was determined before (pre-infusion), during (infusion), and 2 hours after the infusions (post-infusion). RESULTS: The pre-infusion MAC of isoflurane was 1.25 (1.15, 1.35) [median (minimum, maximum)] vol.% for the saline treatment group and 1.25 (1.05, 1.45) vol.% for the adenosine treatment group, and did not differ significantly between the two treatments. The infusion MAC values were not significantly different (p = 0.16) and were 1.25 (0.95, 1.35) vol.% and 1.05 (1.00, 1.25) vol.%, respectively. The post-infusion MAC values differed significantly (p = 0.016); MAC was 1.15 (1.15, 1.35) vol.% and 1.05 (1.05, 1.25) vol.% for the saline and adenosine treatment groups, respectively. During infusion, mean arterial blood pressure decreased significantly (p = 0.008) during adenosine treatment compared with the saline 66 mmHg (52, 72) and 91 mmHg (68, 110), respectively. End-tidal CO2 (Pe'CO2), urine production, hematocrit, and plasma total solids did not differ significantly between the two treatments at any time (all p > 0.05). CONCLUSION: Although the MAC of isoflurane in dogs was not decreased significantly during infusion with adenosine (0.3 mg kg(-1) minute(-1)), it was significantly decreased post-infusion, but only by 0.1 vol.%, an amount not considered clinically important. Adenosine infusion decreased mean arterial pressure by 27% and did not adversely affect renal function.  相似文献   

19.
20.
OBJECTIVE: To evaluate the effects of ketamine, magnesium sulfate, and their combination on the minimum alveolar concentration (MAC) of isoflurane (ISO-MAC) in goats. ANIMALS: 8 adult goats. PROCEDURES: Anesthesia was induced with isoflurane delivered via face mask. Goats were intubated and ventilated to maintain normocapnia. After an appropriate equilibration period, baseline MAC (MAC(B)) was determined and the following 4 treatments were administered IV: saline (0.9% NaCl) solution (loading dose [LD], 30 mL/20 min; constant rate infusion [CRI], 60 mL/h), magnesium sulfate (LD, 50 mg/kg; CRI, 10 mg/kg/h), ketamine (LD, 1 mg/kg; CRI, 25 microg/kg/min), and magnesium sulfate (LD, 50 mg/kg; CRI, 10 mg/kg/h) combined with ketamine (LD, 1 mg/kg; CRI, 25 microg/kg/min); then MAC was redetermined. RESULTS: Ketamine significantly decreased ISOMAC by 28.7 +/- 3.7%, and ketamine combined with magnesium sulfate significantly decreased ISOMAC by 21.1 +/- 4.1%. Saline solution or magnesium sulfate alone did not significantly change ISOMAC. CONCLUSIONS AND CLINICAL RELEVANCE: Ketamine and ketamine combined with magnesium sulfate, at doses used in the study, decreased the end-tidal isoflurane concentration needed to maintain anesthesia, verifying the clinical impression that ketamine decreases the end-tidal isoflurane concentration needed to maintain surgical anesthesia. Magnesium, at doses used in the study, did not decrease ISOMAC or augment ketamine's effects on ISOMAC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号