首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The correlation between end-tidal partial pressure of CO2 (PETCO2) and arterial (PaCO2) was determined for spontaneously breathing ponies under halothane or isoflurane anesthesia. The PETCO2 was useful as a trend indicator of PaCO2 during the first 60 minutes of halothane or isoflurane anesthesia when PaCO2 values were less than 60 to 70 mm of Hg. Halothane anesthesia lasting greater than 90 minutes was associated with PaCO2 values in excess of 60 to 70 mm of Hg, a large arterial- to end-tidal PCO2 difference (PaCO2-PETCO2) and a significant increase in alveolar dead space. These effects were not seen during the same period of isoflurane anesthesia. Arterial blood gas analysis is therefore recommended during halothane anesthesia when the PETCO2 is greater than 60 to 70 mm of Hg. A decrease in alveolar capillary perfusion relative to alveolar ventilation is the most likely cause for the increase in alveolar dead space during halothane anesthesia. Based on these findings, isoflurane may be superior to halothane for prolonged anesthesia of spontaneously breathing horses.  相似文献   

2.
OBJECTIVE: To evaluate the relationship between end-tidal partial pressure of CO(2) (ETCO(2)) and PaCO(2) in isoflurane-anesthetized harp seals. ANIMALS: Three 5-month-old 25- to 47-kg harp seals (Phoca groenlandica). PROCEDURES: PaCO(2) was determined in serial arterial samples from isoflurane-anesthetized seals and compared with concomitant ETCO(2) measured with a side-stream microstream capnograph. Twenty-four paired samples were subjected to linear regression analysis and the Bland-Altman method for assessment of clinical suitability of the 2 methods (ie, PaCO(2) and ETCO(2) determinations). The influence of ventilation rate per minute (VR) on the ETCO(2) to PaCO(2) difference (P[ET-a] CO(2)) was examined graphically. RESULTS: The correlation coefficient between the 2 measurements was 0.94. The level of agreement between ETCO(2) and PaCO(2) varied considerably. Values of ETCO(2) obtained with a VR of < 5 underestimated PaCO(2) to a greater degree (mean bias, -4.01 mm Hg) and had wider limits of agreement of -13.10 to 5.07 mm Hg (-4.01 mm Hg +/- 1.96 SD), compared with a VR of > or = 5 (mean bias, -2.24 mm Hg; limits of agreement, -7.79 to 3.30 mm Hg). CONCLUSIONS AND CLINICAL RELEVANCE: These results indicate that a microstream sidestream capnograph provides a noninvasive, sufficiently accurate estimation of PaCO(2) with intermittent positive ventilation at a VR > or = 5 in anesthetized harp seals.  相似文献   

3.
OBJECTIVE: To evaluate the correlation between the bispectral index (BIS) and end-tidal isoflurane (ET(ISO)) concentration and compare the use of 3 BIS sensor positions in dogs. ANIMALS: 6 adult dogs. PROCEDURES: Mechanically ventilated dogs received pancuronium, and depth of anesthesia was altered by increasing ET(ISO) concentration from 1.5% to 2.3% and 3.0%. The BIS, suppression ratio (relative percentage of isoelectric electroencephalographic waveforms), and signal quality index (SQI) were recorded at each ET(ISO) concentration for each of 3 BIS sensor positions (frontal-occipital, bifrontal, and frontal-temporal positions). RESULTS: The BIS and ET(ISO) concentration were poorly correlated; regardless of sensor positioning, mean BIS values did not change significantly as ET(ISO) was increased. At 3% isoflurane, regardless of sensor positioning, there was an increase in suppression ratio coincident with BIS < 40 in some dogs, whereas paradoxic increases in BIS (> 60) were recorded in others. Furthermore, at 3.0% isoflurane, the SQI was significantly lower for the bifrontal sensor position (compared with values for the other positions), but low SQI values prevented recording of BIS values from the frontal-occipital sensor position in 2 dogs. Overall, BIS values derived from the 3 sensor positions did not differ. CONCLUSIONS AND CLINICAL RELEVANCE: In dogs, BIS values may not reflect changes in depth of isoflurane anesthesia in the absence of noxious stimulation. Of the 3 sensor positions, frontal-temporal positioning provided better correlation with changes in depth of anesthesia induced via changes in isoflurane concentrations. However, the sensor placements yielded similar results at SQI values > 50.  相似文献   

4.
The effects of sevoflurane or isoflurane on arterial blood gas, arterial oxyhaemoglobin saturation and end-tidal CO2 tension were monitored during induction and maintenance of anaesthesia in 10 premedicated New Zealand White (NZW) rabbits.For induction, the anaesthetic agents were delivered via a face-mask. After induction was completed, an endotracheal tube was introduced for maintenance of anaesthesia for a period of 90 minutes. Changes in heart rate, respiratory rate, arterial blood gas, arterial oxyhaemoglobin saturation, blood pH and end-tidal CO2 tension were recorded. Although sevoflurane and isoflurane produce similar cardiopulmonary effects in premedicated rabbits, sevoflurane provides a smoother and faster induction because of its lower blood/gas partition coefficient. Thus sevoflurane is probably a more suitable agent than isoflurane for mask induction and maintenance. Its lower blood solubility also makes sevoflurane more satisfactory than isoflurane for maintenance of anaesthesia because it allows the anaesthetist to change the depth of anaesthesia more rapidly.  相似文献   

5.
The effects of 2 liquid formula diets differing in protein source were evaluated in orphan foals. The response of 7 foals fed a diet containing casein as the protein source, and 6 foals fed a diet containing a combination of whey and casein, was compared with the response in a reference group of 8 mare-raised foals. Orphaned foals were fed 150 kcal/kg of body weight/d, divided into 6 equal feedings of 25 kcal/kg. Formula intake was comparable among the experimental groups, and foals fed the liquid formula diet grew as well as mare-raised foals. There was no difference among groups in mean daily body weight gain, wither height, heart girth, body temperature, pulse, respiration rate, capillary refill time, or skin tenting. Insulin and blood glucose concentrations increased in both groups of foals fed formula diets, returning to prefeeding values within 4 hours. Differences among groups were found for serum alkaline phosphatase, alanine transaminase, cholesterol, creatinine, and glucose values; all other serum chemical values were comparable among groups. Plasma amino acid determinations revealed that arginine and ornithine were significantly lower in foals in both experimental groups than in reference foals, suggesting that arginine may have been the limiting amino acid in these diets. Diarrhea developed in foals in all treatment groups, but in most cases was self-limiting. These results suggest that the protein source of liquid formula diets may be less important in foals than in infants.  相似文献   

6.
7.
One of the main issues in genomic selection was the huge unbalance between number of markers and phenotypes available. In this work, principal component analysis is used to reduce the number of predictors for calculating direct genomic breeding values (DGV) for production and functional traits. 2093 Italian Holstein bulls were genotyped with the 54 K Illumina beadchip, and 39 555 SNP markers were retained after data editing. Principal Components (PC) were extracted from SNP matrix, and 15 207 PC explaining 99% of the original variance were retained and used as predictors. Bulls born before 2001 were included in the reference population, younger animals in the test population. A BLUP model was used to estimate the effect of principal component on deregressed proof (DRPF) for 35 traits and results were compared to those obtained by using SNP genotypes as predictors either with BLUP or with Bayes_A models. Correlations between DGV and DRPF did not substantially differ among the three methods except for milk fat content. The lowest prediction bias was obtained for the method based on the use of principal component. Regression coefficients of DRPF on DGV were lower than one for the approach based on the use of PC and higher than one for the other two methods. The use of PC as predictors resulted in a large reduction of number of predictors (approximately 38%) and of computational time that was approximately 2% of the time needed to estimate SNP effects with the other two methods. Accuracies of genomic predictions were in most of cases only slightly higher than those of the traditional pedigree index, probably due to the limited size of the considered population.  相似文献   

8.
9.
On the basis of plasma concentrations of pantothen[14C]ate, after its intravenous administration, a three compartment open model was proposed to predict the pharmacokinetics of pantothenate in dogs. The model assumed a central compartment comprising the plasma and other extracellular fluids, and distribution into two other peripheral compartments, one of which included the liver. Elimination of unchanged pantothenate was assumed to occur by metabolism from the compartment which included the liver. Distribution of pantothen[14C]ate from the plasma compartment into the liver compartment was shown to be very rapid; during 10 min after intravenous administration about 80 per cent of the dose had been cleared from the plasma compartment. The model successfully predicted the influence (first pass effect) of the liver on the fraction of an oral dose which reached the peripheral plasma unchanged.  相似文献   

10.
Gastric dilatation was experimentally induced in 6 anesthetized dogs maintained with constant-dose isoflurane in oxygen. An intragastric balloon was used to distend the stomach with a constant 30 mm of Hg pressure for 3.5 hours. The PaCO2 was maintained between 35 and 45 mm of Hg, using intermittent positive-pressure ventilation. Cardiopulmonary measurements prior to stomach distension (baseline) were compared with measurements taken during 0.1, 0.5, 1.0, 1.5, 2.5, and 3.5 hours of stomach distension by analyzing the change from baseline in a randomized-block analysis with each dog as a block. After distending the stomach, cardiac index increased (P less than 0.01) from 1.5 to 3.5 hours. Stroke volume did not change, thus the increase in the cardiac index was attributable to an increase in heart rate. During inflation, increases were observed in systemic arterial, pulmonary arterial, and right atrial pressure. Respiratory frequency was unchanged; however, to maintain PaCO2 constant, it was necessary to progressively increase peak airway pressure. Although PaO2 tended to decrease during gastric dilation, the dogs were never hypoxemic. These results indicate that when our methods are used to maintain a constant anesthetic dose of isoflurane in oxygen, an observed increase in cardiovascular performance is expected. This differs from other studies in anesthetized dogs that have shown reduction in cardiovascular performance following gastric dilatation.  相似文献   

11.
The objective of this research was to make available bioelectrical impedance technology for the prediction of kilograms of lean and kilograms of fat-free muscle of Boston butts. Seventy butts were removed from 70 pork carcasses according to standard procedures (NAMP, #406), with the exception that the fat was not removed. After the weight in kilograms (BUTT) and internal temperature in degrees centigrade (TEMP) were recorded, each butt was measured for resistance (Rs, ohms), reactance (Xc, ohms), and distance (L, centimeters) between detector terminals four different ways: parallel or perpendicular to the top of the carcass and on either lean surface or fat surface of the cut. Each cut was physically separated into lean, fat, and bone. Chemical composition (moisture, protein, and fat) was determined on the lean portion. Variable selection analysis was used to develop equations for predicting kilograms of lean and kilograms of fat-free muscle of Boston butts. Results of measurements of the four sites were quite similar; however, measuring perpendicularly on the lean surface is recommended. The prediction equation for kilograms of lean from measurements thus taken is as follows: .461-.0304 x TEMP + .576 x BUTT - .0118 x Rs + .00845 x Xc + .0630 x L. The respective coefficients of these independent variables for predicting kilograms of fat-free muscle are .537, -.0415, .479, -.0139, .00804, and .0764. In an industry application of these coefficients, recording temperature would not be imperative because the temperature range would be sufficiently narrow to render temperature of little practical influence when separating butts according to leanness.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

12.
13.
OBJECTIVE: To evaluate the in vitro effects of adenosine tryphosphate (ATP) on vasomotor tone of equine colonic vasculature. SAMPLE POPULATION: Arteries and veins from the left ventral colon of 14 mixed-breed horses euthanatized for reasons unrelated to cardiovascular or gastrointestinal tract disease. PROCEDURES: Endothelium-intact and -denuded arterial and venous rings were precontracted with 10(-7) and 1.8 x 10(-8) M endothelin-1, respectively. In 1 trial, endothelium-intact rings were also incubated with 10(-4) M N omega-nitro-L-arginine methyl ester (L-NAME) to inhibit nitric oxide (NO) production. Adenosine triphosphate (10(-8) to 10(-3) M) was added in a noncumulative manner, and relaxation percentage versus time curves were generated. Areas under the curves (ie, percentage of relaxation time) were calculated. RESULTS: Relaxation response of arterial and venous rings to ATP was dose-dependent. Percentage of relaxation time in response to 10(-4) and 10(-3) MATP was significantly greater, compared with that for rings not treated with ATP Removal of endothelium attenuated but did not eliminate the relaxation response. Addition of L-NAME did not attenuate the relaxation response in arteries. At higher concentrations, the vascular response to ATP was biphasic. CONCLUSIONS AND CLINICAL RELEVANCE: ATP applied to equine colonic arterial and venous rings with and without intact endothelium induced a biphasic response characterized by transient contraction followed by slow, substantial, and sustained relaxation. This ATP-induced response is possibly mediated by a mechanism other than NO. Adenosine triphosphate may be a useful treatment to modulate colonic vasomotor tone in horses with strangulating volvulus of the ascending colon.  相似文献   

14.
15.
Equine degenerative myeloencephalopathy (EDM) is a common spinal cord disease in the horse. The etiology of EDM currently is unknown. In other species, there are similarities in the clinical signs and neuropathological changes observed in EDM and in copper deficiency. The objective of this study was to determine if horses affected with EDM had low levels of plasma or liver copper. Plasma copper values were determined in 25 EDM affected horses and 35 normal horses. Liver copper levels were determined on 13 EDM affected horses and 22 normal horses. Plasma and liver copper values were not significantly lower in EDM affected horses than in control horses.  相似文献   

16.
The use and aims of various wound dressings are discussed. Application and indications in the horse vary according to the type and location of the wound as well as the nature and availability of the dressing material. Coaptation and immobilization are essential to promote healing in certain locations. Techniques used for bandage application in horses are described, with special emphasis on problem areas.  相似文献   

17.
18.
19.
20.
Four cases of equine lameness were treated with intra-articular polysulphated glycosaminoglycan. Two, two-year-old flat racers were treated conservatively after traumatic injury. They subsequently became lame owing to the formation of new bone and osteophytes. Two older steeplechasers were lame owing to degenerative joint disease. The four horses were treated with intra-articular injections of polysulphated glycosaminoglycans and, after three or four injections, they became clinically sound and were able to continue racing with varying degrees of success.  相似文献   