首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
BACKGROUND: Transvenous electrical cardioversion (TVEC) has been developed for treatment of atrial fibrillation (AF) in horses. The relationship among patient variables, treatment response, and outcome in a typical referral population has not been evaluated. HYPOTHESIS: Patient variables such as age, sex, weight, and duration of arrhythmia affect prognosis for response to treatment and the energy level at which cardioversion occurs. ANIMALS: TVEC was applied to 72 episodes of lone AF in 63 client-owned performance horses, with the majority (54) being Standardbred racehorses. METHODS: Catheterization of the right atrium (RA) and pulmonary artery (PA) through the jugular vein was used for electrode placement before horses were placed under general anesthesia. Biphasic, truncated exponential shock waves were delivered at incremental energy levels until cardioversion was achieved or a maximum single-energy level of 300 J was reached (cumulative energy 50-1,960 J). A multivariate model was constructed to evaluate influence of patient factors on cardioversion energy. RESULTS: Cardioversion was achieved in 71 of 72 episodes (62 of 63 horses) at a mean energy of 165.43 +/- 8.75 J. Cardioversion energy was higher for females than for males, and for interaction terms, weight was negatively related to energy in females and positively related in males. Age was positively related to cardioversion energy in females. No relationship was identified between duration of arrhythmia before treatment and prognosis for response or cardioversion energy. CONCLUSIONS AND CLINICAL IMPORTANCE: TVEC is highly effective in the treatment of lone AF in horses. Although age and sex influence cardioversion energy level, duration of arrhythmia does not.  相似文献   

2.
Five horses were presented for treatment of atrial fibrillation by transvenous electrical cardioversion (TVEC). A dexmedetomidine infusion was administered for sedation during positioning of the cardioversion catheters, and continued during general anesthesia. Shocks were applied until return to sinus rhythm. Dexmedetomidine infusion provided excellent conditions for TVEC catheter placement and procedure.  相似文献   

3.
Background: Whether electrical cardioversion of cardiac arrhythmias results in cardiomyocyte damage is unknown.
Objective: To describe effect of transvenous electrical cardioversion (TVEC) on plasma cardiac troponin I (cTnI) concentration in horses.
Animals: All horses presented to the Cornell University Hospital for Animals for cardioversion of atrial fibrillation between May 2006 and October 2008 were eligible for inclusion in the study. Owners of 14 horses elected for TVEC and each horse was then enrolled (16 procedures).
Methods: Prospective observational study measuring concentrations of plasma cTnI before and after TVEC.
Results: Median cTnI concentration increased from 0.045 ng/mL at baseline (range 0.0–0.20 ng/mL) to 0.11 ng/mL after TVEC (range 0.0–3.73 ng/mL) ( P = .036). This increase was not associated with the number of shocks delivered, maximal energy delivered, cumulative energy delivered, chronicity of atrial fibrillation before cardioversion, or positioning of the pulmonary artery catheter.
Conclusions: The increase in cTnI is unlikely to be clinically important. The increase might be correlated with persistent atrial dysfunction after TVEC, suggesting that a longer convalescent period after the procedure could be warranted.  相似文献   

4.
Pharmacological conversion of atrial fibrillation (AF) to sinus rhythm in horses can be difficult. The objective of this study was to investigate the feasibility of transvenous electrical cardioversion with custom made catheters in eight horses, of which three had failed cardioversion using quinidine sulfate. Two cardioversion catheters and one pacing/sensing electrode were inserted via the right jugular vein and placed using ultrasound guidance into the left pulmonary artery, the right atrium and the right ventricle, respectively. Because immediate recurrence of AF was encountered in the second horse treated, pre-treatment with amiodarone was given to each of the remaining six horses. Induction of general anaesthesia was associated with dislocation of the cardioversion catheter in three horses, requiring a second catheterisation procedure. During general anaesthesia, biphasic R wave synchronised shocks of up to 360 J were delivered between both cardioversion electrodes. In six horses (75%), including two which had failed quinidine sulfate treatment, sinus rhythm was restored with a mean energy level of 295+/-62 J. No side effects were observed. Blood analysis 3 h after cardioversion revealed normal parameters, including cardiac troponin I values. Transvenous electrical cardioversion of atrial fibrillation with custom made cardioversion catheters can be considered as a treatment option for atrial fibrillation in horses, especially when conventional drugs fail.  相似文献   

5.
OBJECTIVE: To describe management of anesthesia for transvenous electrical cardioversion (TVEC) in horses and report perianesthetic complications. DESIGN: Retrospective case series. ANIMALS: 62 horses with atrial fibrillation and without underlying cardiac disease and 60 horses without atrial fibrillation. PROCEDURES: Medical records of horses with atrial fibrillation anesthetized for TVEC were reviewed, as were records of horses without atrial fibrillation anesthetized for magnetic resonance imaging (MRI). The TVEC group horses were compared with MRI group horses for incidence of intraoperative bradycardia and use of inotropic drugs. Data obtained included patient signalment, weight, duration of anesthesia, heart rate and arterial blood pressure during anesthesia, anesthetic drugs administered, mode of ventilation, perioperative complications, and quality of recovery. RESULTS: The TVEC group horses were > 1 year of age and were predominantly Standardbreds. The TVEC group horses underwent a total of 76 anesthetic episodes. For 40 (52.6%) anesthetic episodes, horses received xylazine only for premedication, and for 26 (34.2%) anesthetic episodes, horses received xylazine and butorphanol. Induction of anesthesia consisted of ketamine administration in various combinations with diazepam and guaifenesin for 74 (97.4%) anesthetic episodes and ketamine alone for 2 (2.6%). Bradycardia in horses was encountered during 15 of 76 (19.7%) anesthetic episodes. Minor signs of possible postanesthetic myopathy occurred following 6 (7.9%) anesthetic episodes. No significant difference was found between TVEC and MRI group horses regarding incidence of bradycardia and inotropic drug administration. CONCLUSIONS AND CLINICAL RELEVANCE: Short-duration anesthesia for TVEC of atrial fibrillation in horses without underlying cardiac disease was a safe procedure.  相似文献   

6.
Electrical cardioversion of atrial fibrillation is a well-established technique for restoration of sinus rhythm in humans. While transthoracic cardioversion is more commonly used, transvenous electrical cardioversion (TVEC) has been reported as having higher efficacy at substantially lower energy levels. In horses, treatment of atrial fibrillation has essentially been limited to the administration of quinidine salts either orally or intravenously. TVEC provides an alternative to quinidine salts, especially for those animals in which quinidine is neither effective nor tolerated. The present report details this technique in horses, discusses possible complications of the procedure, and provides guidance for successful outcome. Still and video images are used to illustrate details with regard to TVEC techniques in horses. Please view supplemental material for the videos.  相似文献   

7.
BackgroundTransvenous electrical cardioversion (TVEC) is 1 of the main treatment options for atrial fibrillation (AF) in horses. Large‐scale studies on factors affecting success and prognosis have primarily been performed in Standardbred populations.Hypothesis/ObjectivesTo determine factors affecting cardioversion success, cardioversion difficulty and recurrence in a predominant Warmblood study sample.AnimalsTVEC records of 199 horses.MethodsRetrospective study of TVEC procedures of horses admitted for AF without severe echocardiographic abnormalities. Horse and procedural factors for success and cumulative amount of energy (≤ 600 J vs > 600 J) were determined using multivariable logistic regression. A survival analysis was performed to determine risk factors for recurrence.ResultsTwo hundred and thirty‐one TVEC procedures were included, with a 94.4% success rate and 31.9% recurrence rate (51/160). Mitral regurgitation (OR 0.151, 95% CI 0.032‐0.715, P = .02) and AF cycle length (OR 1.05, 95% CI 1.01‐1.09, P = .02) were independent determinants for success. Catheter type (OR 0.154, 95% CI 0.074‐0.322, P < .001), previous AF episode (OR 3.10, 95% CI 1.20‐8.01, P = .02), tricuspid regurgitation (OR 2.54, 95% CI 1.25‐5.13, P = .01), and body weight (OR 1.009, 95% CI 1.003‐1.015, P = .004) were significantly correlated with cumulative amount of energy delivered. Significant risk factors for recurrence after a first AF episode were sex (stallion; HR 3.05, 95% CI 1.34‐6.95, P = .008), mitral regurgitation (HR 1.91, 95% CI 1.08‐3.38, P = .03), and AF duration (HR 1.001, 95% CI 1.0001‐1.0026, P = .04).Conclusions and Clinical ImportanceBoth horse and procedural factors should be considered when assessing treatment options and prognosis in horses with AF.  相似文献   

8.
Rectilinear biphasic cardioversion was used in 2 horses with idiopathic sustained atrial fibrillation; 1 horse converted to sustained sinus rhythm. Variables that potentially affected outcome of the electrical cardioversion procedures in these horses included duration of arrhythmia, placement of cardioverter pads and paddles, serum electrolyte concentrations, and treatment with quinidine. Serum cardiac troponin I concentration, measured to determine whether the myocardium was damaged from the electrical shocks, was within the reference range in both horses after the procedure. Biphasic electrical cardioversion may provide an alternative to pharmacologic cardioversion with quinidine in horses. The rectilinear biphasic defibrillator-cardioverter uses a unique biphasic waveform to deliver constant current to the myocardium during cardioversion, regardless of transthoracic impedance. Biphasic cardioversion is safer and more effective than traditional monophasic cardioversion in humans and animals.  相似文献   

9.
A 20-year-old warmblood breeding stallion presented to a University practice for semen collection and evaluation was incidentally diagnosed with atrial fibrillation (AF). Electrocardiogram recordings during breeding revealed inappropriately rapid tachycardia and occasional ventricular premature depolarizations/aberrant ventricular conduction. Transvenous electrical cardioversion was performed. After successful cardioversion the horse displayed supraventricular ectopy and atrial contractile dysfunction and was administered sotalol hydrochloride in an attempt to decrease the risk of AF recurrence. Supraventricular ectopy and echocardiographic evidence of atrial dysfunction gradually improved and normalized over 6 months. No direct adverse effects of the chronic anti-arrhythmic treatment were observed and libido and semen quality were unaffected. AF recurred 6 months after cardioversion and sotalol therapy was continued to control the ventricular ectopy/aberrant ventricular conduction during semen collection. Considerations regarding pathologic arrhythmias and inappropriately high heart rates in breeding stallions with AF may be similar to those in riding horses. Sotalol hydrochloride was a safe anti-arrhythmic drug in the management of this case.  相似文献   

10.
OBJECTIVE: To describe a sling recovery system (Anderson Sling) for horses and to evaluate outcome of high-risk horses recovered from general anesthesia by a sling. STUDY DESIGN: Retrospective study. SAMPLE POPULATION: Horses (n=24) recovered from general anesthesia. METHODS: Complete medical and anesthetic records (1996-2003) for horses recovered from general anesthesia using the Anderson Sling system were evaluated retrospectively. Information retrieved included anesthetic protocol, surgical procedure, recovery protocol, recovery time, and quality of the recovery. Horses were recovered from anesthesia supported by the Anderson Sling in a standing position within a traditional padded equine recovery stall. RESULTS: Twenty-four horses had 32 assisted recoveries; 31 events were successful. No complications associated with the sling or recovery system protocol occurred. One horse was intolerant of the sling's support and was reanesthetized and recovered successfully using head and tail ropes. CONCLUSION: The Anderson Sling recovery system is an effective and safe way to recover horses that are at increased risk for injury associated with adverse events during recovery from general anesthesia. CLINICAL RELEVANCE: The Anderson Sling system should be considered for assisted recovery of equine patients from general anesthesia.  相似文献   

11.
BACKGROUND: Atrial contractile dysfunction occurs in some species after conversion of atrial fibrillation (AF) to normal sinus rhythm (NSR) but has not been reported in horses with naturally occurring AF. HYPOTHESIS: Transthoracic echocardiography allows detection of left atrial (LA) mechanical dysfunction in horses after conversion of AF to NSR. ANIMALS: Five Standardbreds with AF and 6 healthy Standardbreds of similar age, weight, and athletic condition were included in this study. METHODS: Four horses were treated pharmacologically (quinidine), and 1 horse was treated by means of transvenous electrical cardioversion. Echocardiographic examinations were performed in normal horses (once) and in AF horses (24 hours and 72 hours after conversion to NSR) by means of 2-dimensional echocardiography (2DE), transmitral flow Doppler, and tissue Doppler imaging (TDI) techniques. Echocardiographic indices of LA mechanical function were compared between normal horses and AF horses. RESULTS: Two-dimensional echocardiography and TDI indices of LA mechanical function revealed significant decreases in LA contractile function and LA reservoir function 24 hours after cardioversion. This decrease was no longer statistically significant 72 hours after cardioversion, but changes in echocardiographic variables between 24 and 72 hours varied among horses. CONCLUSIONS AND CLINICAL IMPORTANCE: LA contractile dysfunction can be evaluated in horses by use of 2DE, transmitral Doppler flow velocity profiles, and analyses of LA wall motion by TDI. The results of this study are consistent with AF-induced atrial remodeling, although residual treatment effects or influence of underlying primary myopathy cannot be excluded.  相似文献   

12.
OBJECTIVE: To describe focal destructive lesions of the proximal sesamoid bones (PSBs) as a complication of dorsal metatarsal artery catheterization performed for direct blood pressure monitoring during equine general anesthesia. STUDY DESIGN: Retrospective study. ANIMALS: Three client-owned horses. METHODS: A dorsal metatarsal artery was catheterized in each of 3 horses for direct blood pressure monitoring during anesthesia. Radiography, ultrasonography, synoviocentesis, and arthroscopy were used to diagnose postoperative lameness that occurred in the limb used for blood pressure monitoring. RESULTS: Horses developed severe lameness, localized to the fetlock region of the catheterized limb within 21 days of surgery. Antibiotic therapy was administered. Surgical debridement was possible in 1 horse. Two horses that had lesions that were inaccessible, failed to respond to medical management and were euthanatized. The 3rd horse that had surgical debridement of affected bone, survived. Changes in hospital protocol, by improving aseptic technique during catheter insertion and use of new manometer tubing and heparinized saline for each arterial catheter inserted in the dorsal metatarsal artery, have eliminated this complication. CONCLUSIONS: Diagnosis and treatment of destructive lesions of the PSB were difficult. Strict aseptic technique should be followed during insertion of arterial catheters. CLINICAL RELEVANCE: Focal destructive lesions of the PSB subsequent to dorsal metatarsal arterial catheterization is a rare but serious complication of equine anesthesia.  相似文献   

13.
The aim of this study was to investigate the potential haemodynamic effects of valvular insufficiency and recurrent airway obstruction (RAO) in horses with atrial fibrillation (AF). Therefore in ten healthy horses (group 1) and 40 horses with AF a clinical examination, a lung examination, echocardiography and right heart catheterization for measurement of intracardic and pulmonary pressures were performed. According to the clinical findings the horses with AF were subdivided into 4 groups (group 2: AF; group 3: AF/valvular insufficiency; group 4: AF/RAO; group 5: AF/valvular insufficiency/RAO). Most of the horses of group 3 and 5 suffered from two valvular insufficiencies (mitral and tricuspid valve insufficiency: n=11, mitral and aortic valve insufficiency: n=2). The remaining horses showed a single mitral (n=6), tricuspid (n=2) or aortic valve insufficiency (n=1) or more than two valvular insufficiencies (n=4). In group 2 right ventricular mean pressure (RVPm) was higher than in group 1 and 4 (P<0.025); diastolic right ventricular pressure was higher than in group 1; PWP was higher than in group 1 and group 4; PDP was lower compared to group1. Compared to group1 in group 3 left atrial diameter (LA) was greater; the PAPs was higher and the PDP lower (P<0.05). In group 4 RVPm and PWP was lower compared to group 2. In group 5 LA, fractional shortening and diastolic left ventricular diameter were greater, PWP and PAPs were higher and PDP lower compared to group1. Twenty six of the 40 horses with AF (65%) were treated. Successful cardioversion to sinus rhythm occurred in 15 horses (58%). Therapy was successful in 50% of the treated horses of group 2 and 3, in 67% of the treated horses of group 4 and in 63% of the treated horses in group 5. In conclusion the presence of valvular insufficiency or RAO influences the haemodynamics of horses with AF.  相似文献   

14.
REASON FOR PERFORMING STUDY: Good results have been obtained with a human amiodarone (AD) i.v. protocol in horses with chronic atrial fibrillation (AF) and a pharmacokinetic study is required for a specific i.v. amiodarone treatment protocol for horses. OBJECTIVES: To study the efficacy of this pharmacokinetic based i.v. AD protocol in horses with chronic AF. METHODS: Six horses with chronic AF were treated with an adapted AD infusion protocol. The protocol consisted of 2 phases with a loading dose followed by a maintenance infusion. In the first phase, horses received an infusion of 6.52 mg AD/kg bwt/h for 1 h followed by 1.1 mg/kg bwt/h for 47 h. In the second phase, horses received a second loading dose of 3.74 mg AD/kg bwt/h for 1 h followed by 1.31 mg/kg bwt/h for 47 h. Clinical signs were monitored, a surface ECG and an intra-atrial electrogram were recorded. AD treatment was discontinued when conversion or any side effects were observed. RESULTS: Three of the 6 horses cardioverted successfully without side effects. The other 3 horses did not convert and showed adverse effects, including diarrhoea. In the latter, there were no important circulatory problems, but the diarrhoea continued for 10-14 days. The third horse had to be subjected to euthanasia because a concomitant Salmonella infection worsened the clinical signs. CONCLUSION: The applied treatment protocol based upon pharmacokinetic data achieved clinically relevant concentrations of AD and desethylamiodarone. POTENTIAL RELEVANCE: Intravenous AD has the potential to be an alternative pharmacological treatment for AF in horses, although AD may lead to adverse drug effects, particularly with cumulative dosing.  相似文献   

15.
In this study ultrasonography, local anesthesia, and endoscopy were performed in both ears of 23 horses. The aim was to find a reliable technique for examination of the external ear canal in standing sedated horses and to create a grading of debris and the occurrence of abnormalities in clinically healthy horses. Local blockage of the great and internal auricular nerves was performed after caudal palpation at the base of the ear and ultrasonographic assessment of the styloid process of the auricle as a reference point for the needle placement. The otoscopic examination was accomplished with two flexible video endoscopes with 2- and 7-mm tip diameters. The depth of the styloid process varied ultrasonographically from 2.08 to 2.73 cm on the left side and from 2.04 to 2.76 cm on the right side. Local anesthesia was successful in all sedated horses, without any long-term complications. The grading of endoscopic appearance of the skin, epithelium, and ceruminous and cell debris in the cartilaginous and osseous part including tympanic membrane of the equine external ear canal ranged from I to III. Abnormalities like osteoma, granuloma, hemorrhagic or erythematous areas, and narrowing of the osseous part of the external ear canal due to stenosis (exostosis) were seen in 10 of 23 horses. The tympanic membrane was visualized in 20 of 23 horses. Local blockage of the great and internal auricular nerves was found to be a reliable method for equine ear anesthesia.  相似文献   

16.
The objective of this study was to describe method of placement, and frequency and severity of complications associated with a subpalpebral lavage system placed in the medial aspect of the equine inferior eyelid. The inferomedial subpalpebral lavage (ISPL) tube is positioned deep in the medial aspect of the inferior conjunctival fornix so that the footplate lies flat between the lower eyelid and the anterior surface of the nictitans. Retrospective data from the placement of 92 ISPL systems placed in 86 horses during a 31-month period were examined. Tube placement was performed using sedation and regional anesthesia only in 59% of horses. The median duration of tube placement was 19 days (range: 1-61 days). Seventy-one horses were treated for up to 55 days following discharge from hospital with an ISPL tube in place. No complications were reported with 59% of ISPL systems. Non-ocular complications were found in 38% of ISPL systems and included tube displacement from the conjunctival fornix (18%), suture loss requiring resuturing of the system to the horse's head (14%), and damage necessitating replacement of the injection port (6%). Ocular complications were recorded in 3% of horses and were limited to inferior eyelid swelling. Vision was retained in 88% of horses. The ISPL system is easily and safely placed, and well tolerated for extended periods. It appears to be associated with infrequent and minor complications when compared with placement of subpalpebral lavage tubes in the superior eyelid.  相似文献   

17.
Transvenous electrical cardioversion was attempted in a horse with drug refractory atrial fibrillation. A temporary pacing catheter and two defibrillation catheters were inserted transvenously into the right ventricular apex, the right atrium and the pulmonary artery, respectively. Under general anaesthesia 100, 200, 300 and 360 J monophasic shocks were delivered between both defibrillation catheters but sinus rhythm could not be restored. Immediately after the 200, 300 and 360 J shock, transient third-degree atrioventricular block occurred for a period of, respectively, 15, 40 and 55 s. These periods of profound bradycardia were corrected by temporary right ventricular pacing until spontaneous conduction resumed. It is concluded that temporary right ventricular pacing should be available during electrical cardioversion of atrial fibrillation in horses.  相似文献   

18.
Monopolar electrosurgical cutting was used to correct epiglottal entrapment in 5 horses. The operations were carried out in the conscious animal, using topical anesthesia. The procedure required the use of a coagulation electrode designed specifically for electrosurgery, introduced through the instrument channel of a fiberoptic endoscope. The results were satisfactory and serious complications were not encountered. In 2 horses, excessive submucosal swelling developed at the site of the surgical wound, and the tumefaction took several weeks to subside in one of these horses. In both horses, the long-term outcome was a minor degree of reentrapment. The main advantages of this technique, compared with other corrective procedures, related to the avoidance of the need for general anesthesia and laryngotomy, allowing racehorses to be treated without any major interruption in their training schedules. The surgery was simple, rapid, and bloodless, and was not followed by any dorsal displacement of the soft palate. It was suggested that transendoscopic electrosurgery has potential for use in the treatment of a number of other diseases of the respiratory tract and other systems, both in the horse and in other species. In the equine respiratory tract, the technique might usefully be applied to the treatment of guttural pouch tympany, soft palate cysts, nasopharyngeal polyps, choanal atresia, subepiglottic cysts, and tracheal granulomata. A review of 21 cases of epiglottal entrapment in horses revealed no evidence to support the suggestion that dorsal displacement of the soft palate is a cause of epiglottal entrapment or vice-versa.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

19.
OBJECTIVE: To assess gait abnormalities associated with selective anesthesia of the suprascapular nerve (SSN) achieved by use of perineural catheterization and thereby determine the function of that nerve as it relates to gait in horses. ANIMALS: 3 adult horses with no preexisting clinically apparent lameness at a walk. PROCEDURE: Each horse was anesthetized; the right SSN was exposed surgically for placement of a perineural catheter to permit delivery of 1 mL of 2% mepivacaine hydrochloride. Six hours after recovery from anesthesia, each horse was videotaped while walking (50-step data acquisition period) before and after administration of mepivacaine. Videotapes were reviewed and the proportion of abnormal steps before and after selective SSN anesthesia was assessed. A step was considered abnormal if a marked amount of scapulohumeral joint instability (ie, lateral luxation of the proximal portion of the humerus) was observed during the weight-bearing phase of the stride. RESULTS: Clinically apparent gait dysfunction was detected in all 3 horses following perineural administration of the local anesthetic agent. Anesthesia of the SSN resulted in scapulohumeral joint instability as evidenced by consistent lateral excursion of the shoulder region during the weight-bearing phase of gait at a walk. The proportion of abnormal steps before and after SSN anesthesia was significantly different in all 3 horses. CONCLUSIONS AND CLINICAL RELEVANCE: These data support the role of the SSN in shoulder joint stability in horses and define SSN dysfunction as 1 mechanism by which the syndrome and gait dysfunction clinically referred to as sweeny may develop.  相似文献   

20.
Intercoccygeal, or caudal, epidural injection of local anesthetics is a convenient method of producing analgesia and local anesthesia of the tail and perineal structures in conscious standing horses. This technique has been further developed to provide long duration analgesia and anesthesia by placement of catheters into the epidural space of horses. More recently, opioid, alpha-2 adrenergic agonists, ketamine and other analgesic agents have been administered by caudal epidural injection, providing pain relief in both conscious, standing and anesthetized, recumbent horses. This chapter describes the development of different anesthetic and analgesic epidural techniques in horses, methods for epidural injection and catheterization, and reviews the current literature related to epidural analgesia and pain control in horses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号