首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The objective of the study was to determine the diagnostic performance of the Pourquier ELISA for detection of antibodies against Mycobacterium avium subsp. paratuberculosis (Map) in individual milk samples and in bulk milk samples. For individual milk samples the specificity of the Pourquier ELISA was estimated by testing a panel of individual milk samples from certified Map-free herds. The relative sensitivity of the assay in individual milk samples and agreement of the results with those of serum samples was estimated by testing panels of paired serum-milk samples from seropositive cattle, whole-herd investigations, and moderate or heavy shedders. The specificity of the ELISA for individual milk samples was still 99.8% at a cut-off of 20% sample to positive (S/P) value, clearly lower than the cut-off defined by the manufacturer (30% S/P). The relative sensitivity for individual milk samples as compared with positive serum samples was 87% for a cut-off of 20% S/P, and 80% for a cut-off of 30% S/P. The sensitivity of this ELISA for detection of high shedders was >90% both for individual milk and serum samples, also agreement was very good (kappa=0.91 for all paired samples). The specificity of the Pourquier ELISA in bulk milk samples was investigated by testing bulk milk samples from certified Map-free herds. Feasibility of bulk milk testing was investigated by titrating ELISA positive individual milk samples in negative milk. In addition, 383 bulk milk samples from herds with a known within-herd seroprevalence were tested. The specificity of the ELISA for bulk milk samples was 100% at a cut-off of 12.5% S/P. At the cut-off recommended by the manufacturer (30% S/P) performance of the bulk milk ELISA related to herd status (> or =2 seropositive cows) was rather poor, corresponding with a sensitivity of 24% and a specificity of 99% relative to serology. However, at the revised cut-off for bulk milk of 12.5% S/P and a within-herd seroprevalence of > or =3%, sensitivity and specificity relative to serology were 85% and 96%, respectively. Given the current herd-level seroprevalence in The Netherlands, these test characteristics corresponded with positive and negative predictive values for bulk milk of 67% and 94%, respectively. In conclusion, the diagnostic performance of the Pourquier ELISA for individual milk samples creates opportunities for a cheaper and more feasible testing scheme, while the diagnostic performance for bulk milk samples warrants further consideration.  相似文献   

2.
Surveillance of porcine reproductive and respiratory syndrome (PRRS) in negative sow farms is usually performed by testing for the presence of antibodies against PRRS virus in serum with a commercial ELISA test. The objective of this study was to evaluate the feasibility of pooling serum samples for detection of PRRS virus antibodies by ELISA. The effect of pool size on the sensitivity and specificity of the ELISA test was evaluated by testing true positive samples and false positive samples, respectively, diluted in negative sera. The effect of three different cut-off values for the interpretation of the diagnostic test (0.4, 0.3 and 0.2) was evaluated as well. Furthermore, the obtained sensitivity and specificity estimates were used to calculate the herd sensitivity and herd specificity of surveillance protocols in different scenarios. The results showed that pooling serum samples to detect PRRSV antibodies resulted in a decrease in sensitivity and an increase in specificity, compared to testing individual samples, while the reduction of the s/p cut-off value recommended by the manufacturer (0.4) had the opposite effect. We describe an approach that can increase the herd sensitivity of a surveillance protocol for breeding herds, while maintaining high herd specificity and low testing costs. This can be achieved by sampling a larger number of animals and running the samples in pools. Therefore, the conventional monitoring protocols based on ELISA on individual samples can be improved by using pooled-sample testing.  相似文献   

3.
The objective of this study was to develop an indirect enzyme-linked immunosorbent assay (ELISA) using a sonicated pure culture of Lawsonia intracellularis as the antigen (So-ELISA). A total of 332 serum samples, consisting of 232 experimentally infected animals and 100 animals naturally infected with L. intracellularis, were used to assess the diagnostic sensitivity. Three hundred and fifty-five sera from uninfected animals were used to determine the diagnostic specificity. The receiver operating characteristic and mean +3 standard deviation of optical density (OD) values from uninfected animals were used for selecting cut-off points. The diagnostic accuracy of So-ELISA was considered to be high as the area under the curve index was 0.991 with 0.0029 standard error. The optimal cut-off for So-ELISA was set at 0.45 OD with 89.8% sensitivity and 99.4% specificity based on a combination of good sensitivity and high specificity. No cross-reactivity was found in sera from pigs exposed to Brachyspira pilosicoli, B. hyodysenteriae, Campylobacter mucosalis, C. jejuni, or C. coli. Inter- and intracoefficient of variation of all control sera tested with So-ELISA was less than 10%. The observed agreements between So-ELISA and the immunoperoxidase monolayer assay tested with experimental challenge animals and field samples were 95.08% with 0.88 kappa and 90.65% with 0.74 kappa value, respectively. So-ELISA was able to detect the seroconversion of infected animals at 2 to 4 weeks after exposure to L. intracellularis. Based on the validation results, So-ELISA could be used as an alternative serology for proliferative enteropathy diagnosis.  相似文献   

4.
BACKGROUND: Confirmatory tests for failure of transfer of passive immunity (FTPI) in dairy calves require direct measurements of the serum immunoglobulin G concentration. Enzyme-linked immunosorbent assay (ELISA) has advantages over single radial immunodiffusion (SRID) in terms of cost and time. OBJECTIVES: To evaluate the agreement between ELISA and SRID, and to compare the diagnostic performance of ELISA with indirect methods, in the detection of FTPI in calves. ANIMALS: One hundred and fifteen dairy calves (aged 0-10 days) from 23 calf-rearing facilities. METHODS: Prospective, observational study. The agreement between SRID and ELISA was determined by the Bland-Altman method. Fixed bias (SRID - ELISA) was calculated. For comparison of the diagnostic performance of ELISA with indirect methods, sensitivity, specificity, and area under the curve (AUC) of receiver operating characteristic (ROC) curves were calculated at cut-off values of 500 and 1,000 mg/dL. RESULTS: The agreement between SRID and ELISA was 94%. Fixed bias (SRID - ELISA) was 140 +/- 364 mg/dL. The AUC and sensitivity of ELISA at the cut-off value of 1,000 mg/dL were higher than those of indirect methods (P<.004). The specificity of ELISA at the cut-off value of 1,000 mg/dL was not higher than that of indirect methods, except for serum total protein concentration assay. CONCLUSION AND CLINICAL IMPORTANCE: ELISA exhibited good diagnostic performance and good agreement with SRID. ELISA is an adequate method for both screening and confirmatory tests for FTPI in dairy calves at the cut-off value of 500 mg/dL.  相似文献   

5.
In this study, packed cell volume-values (PCV) are evaluated as indicator of trypanosomiasis infections in cattle. A total of 734 blood samples were collected in 11 different sampling sites in eastern Zambia: 84 calves (<1 year), 52 young females and 40 young males (between 1 and 3 years), 228 cows, 317 oxen and 13 bulls (>3 years). All samples were subjected to three diagnostic tests: parasitological examination using the buffy coat method, PCR/RFLP and PCV determination. The results were compared and analysed in a Bayesian model, which allowed the estimation of the infection prevalence and the respective test sensitivities and specificities. The presence of a trypanosomal infection significantly reduced the PCV, independently of the age and sex of the infected animal. The estimated prevalence of trypanosomal infections in the study area was 34% (95% credibility interval: 30–38%). While the specificity of both the parasitological and the PCR/RFLP tests were set to 1, the parasitological diagnosis had a low sensitivity (37%) compared to the PCR/RFLP (96%). When using a cut-off value of 24, the PCV had a high specificity (98%) but a rather low sensitivity (53%) for identifying trypanosomiasis infections. Using 26% as a cut-off increased the sensitivity to 76% without much affecting the specificity (94%). A parallel combination of the parasitological diagnosis and the PCV improved the diagnostic sensitivity (74% and 89% for PCV cut-off values of 24% or 26%, respectively) while specificity remained high (98% and 94% for PCV cut-off values of 24% or 26%, respectively). These results suggest that such a combination could advantageously be used for the diagnosis of cattle trypanosomiasis in the field: it is much more sensitive than parasitological examination alone and it is much cheaper than molecular tests. However, the value of this approach depends largely on the determination of an appropriate cut-off value to consider a sample positive, depending on the required test sensitivities and specificities.  相似文献   

6.
The study reports the performance of four indirect enzyme-linked immunosorbent assays (ELISAs) for antibody (AB) detection using microtitre plates which were precoated with native or heat/detergent denatured antigens (AGs) from Trypanosoma congolense (T.c.) and T. vivax (T.v.), and stored for between 1 to 206 days at +37 degrees C. Bovine serum samples were obtained by sequential bleeding of 3-months old T.c.-infected bulls and their uninfected cohorts, as well as by a single bleeding of uninfected adult cattle. The first day of AB detection, and observations on samples after this (defined as estimated ELISA sensitivity), depended on the cut-off value in the specific ELISAs. Cut-off values from pre- and early post-infection samples of individual animals demonstrated a seroconversion in all ELISAs on average after 10-15 days post-infection (dpi). The AB detection was delayed in the T.c. native and denatured AG-based ELISAs using cut-off points from uninfected cohort cattle (16.5 dpi, 19.3 dpi) and the adult cattle population (22.1 dpi, 25.0 dpi). The T.v. AG-based ELISAs however lacked crossreactiviy to T.c. ABs. The estimated sensitivity of each T.c. AG-based ELISA was above 96% throughout, but significantly lower for the T.c. native AG-based ELISA (91.1%) when the adult cattle derived cut-off point was used (p<0.01). The sensitivity of the phase contrast buffy coat technique was similar to the T.c. AG-based ELISAs, but significantly lower when the T.c. denatured AG-based ELISA was used at the adult cattle derived cut-off point (p<0.05). The implications of the results and future research aspects on ELISAs to detect trypanosomal ABs and AGs are discussed.  相似文献   

7.
The performance characteristics of a blocking ELISA test applied to serum and individual milk for the detection of antibodies to bovine viral diarrhoea virus (BVDV) were assessed using 1189 matched milk/serum samples collected from cows of 42 dairy herds located in Brittany (west of France). This test was based on a monoclonal antibody directed against non-structural protein NS2-3 of pestiviruses. All tests were performed blind. For each type of sample, negative/positive cut-off values were determined using receiver operating characteristic (ROC) analysis. Sensitivity and specificity were estimated using the virus neutralisation test as a reference. For sera, the ROC analysis provided a negative/positive inhibition percentage cut-off value of 50% giving a sensitivity and a specificity of 96.9 and 97.8%. For individual milk samples, the cut-off was fixed at 30%, leading to a sensitivity and a specificity of 96.9 and 97.3%. Using this test, a good overall agreement was found between results obtained on matched milk/serum samples (Kappavalue=0.95). The present results indicate that this blocking ELISA test is reliable enough for use in a mass screening and control scheme on BVDV.  相似文献   

8.

Background

Failure of passive transfer of maternal immunity via colostrum can occur in the bovine, and a number of blood tests have been developed to test calves for this failure. It is not clear which test is most suitable for this purpose. The objective was to examine the most commonly used tests for failure of passive transfer and to decide which is most suitable for routine laboratory use. 126 serum samples were taken from calves of dairy cows after birth but prior to colostrum feeding, and at 48 h of age. Five different tests were compared against radial immunodiffusion which is considered the appropriate reference method. These tests were serum gamma-glutamyltransferase levels, serum protein levels, serum globulin levels, an enzyme linked immunosorbent assay and the zinc sulphate turbidity test.

Results

The tests examined displayed high sensitivity but widely varying specificity. Examination of the use of different cut-off points allowed some improvement in specificity at the expense of sensitivity, but the tests which had performed best at the original cut-off points still displayed the best performance. Gamma-glutamyltransferase levels as a measure of colostrum absorption returned, in this study, the best balance between sensitivity and specificity. The ELISA used in this study and serum globulin levels displayed performance similar to the gamma-glutamyltransferase levels. Serum total protein was less successful than others examined at providing both sensitivity and specificity but may, when performed via refractometer, be useful for on-farm testing. As currently performed the poor sensitivity for which the zinc sulphate turbidity test is most often criticized is evident. Modification of the cut-off point to increase specificity is less successful at balancing these parameters than the ELISA, gamma-glutamyltransferase levels, and globulin levels.

Conclusions

Gamma-glutamyltransferase levels, ELISA testing and circulating globulin levels performed best in detecting failure of passive transfer in serum samples, although all three had some practical considerations.  相似文献   

9.
A recently developed indirect ELISA for the detection of bluetongue virus (BTV)-specific antibodies in bovine milk samples was compared to that of the routinely used competitive ELISA on serum samples. During the bluetongue outbreak in the Netherlands in 2006, caused by BTV serotype 8, coupled serum and milk samples were obtained from 470 individual cows from 10 BTV-infected farms with an average seroprevalence of 57%. In addition, bulk milk samples of the same farms, and historically BT-negative samples were tested. Compared to the ELISA for sera, the relative specificity and sensitivity of the ELISA for milk samples is 96.5% and 98.9%, respectively when using a S/P% cut-off value of 50% as advised by the manufacturer. The optimal cut-off value was found at S/P% of 90% revealing an optimal specificity (99.0%) combined with an optimal sensitivity (98.1%). Titres in positive individual milk samples ranged from 1 to 2048 with a peak titre of 128. Bulk milk samples contained antibodies with titres ranging from 64 to 512. The ELISA for milk samples was found to be a reliable and robust test. This diagnostic tool is very useful, and may replace the ELISA for serum samples as first choice in order to get insight into the status of lactating individual animals and therewith of the entire herd with respect to BTV infection.  相似文献   

10.
An ELISA was developed for the detection of Fasciola hepatica antibody in serum of cattle. The assay was applied to sera from 258 naturally infected cattle, 256 non-infected cattle and six calves experimentally infected with F. hepatica. The diagnostic sensitivity and specificity of the ELISA test was 98% (95% confidence intervals, 96-100%) and 96% (95% confidence intervals, 93-98%) respectively at a cut-off value of 15% positivity. The results using sera from the experimentally infected calves showed that antibodies were first detected 2-4 weeks after infection. The ELISA test was also compared to the commercially available Bio-X bovine F. hepatica ELISA kit. A subset of 39 positive sera and 47 negative sera were selected from the samples used to evaluate the in-house test. The results indicated that the agreement between the two tests was almost perfect (k statistic=0.82).  相似文献   

11.
Peste des petits ruminants (PPR) is an acute, febrile, highly contagious and economically important viral disease of small ruminants. A polyclonal antibody based indirect ELISA was developed for detection of antibodies to PPR virus in the serum samples of goats and sheep using purified PPR viral antigen propogated in Vero cell culture. A threshold (cut-off) value was set as twice the mean of the negative population based on the distribution of known negative serum samples in respect of PPR virus antibodies in the test. A total of 1544 serum samples from goats and sheep were screened by indirect ELISA and competitive ELISA. The indirect ELISA compared very well with competitive ELISA, with a high degree of specificity (95.09%) and sensitivity (90.81%). When compared with virus neutralization test, the present assay had 100% specificity and 80% sensitivity. With serum samples, the assay could clearly differentiate animals from the infected population from uninfected ones. These results suggest that the indirect ELISA may be a good alternative tool to competitive ELISA for seroepidemiological surveys.  相似文献   

12.
In the Danish pig production system, an indirect enzyme-linked immunosorbent assay (ELISA) for detection of antibodies in meat juice is used for Salmonella surveillance. Quality control (QC) of this ELISA was previously based on repeated testing of control serum samples. The purpose of the study reported here was to collect, characterize, and implement a panel of meat juice pools for supplemental internal QC. Muscle samples for extraction of meat juice were collected from slaughter pigs of 5 herds infected with Salmonella spp. and from 4 herds without Salmonella infection. A QC panel with 39 pools of meat juice, yielding ELISA optical density (OD) values covering the full range of expected OD values, was prepared and tested repeatedly to determine mean and SD OD values. Each pool was tested twice on each microtitration plate, and the results were used to determine limits for validity of future tests. This QC panel was included as an internal QC to be tested every month. Besides the QC panel, 2 panels containing 100 samples of meat juice with OD above the positive cut-off value and 100 samples with OD below that value were prepared for quarterly control of the diagnostic sensitivity (DSe) and the diagnostic specificity (DSp) of the ELISA. The inclusion of these panels in the QC system will provide information about drifts in DSe and DSp of the test. The procedures described here can be applied to other tests where meat juice samples are used for testing.  相似文献   

13.
Over a period of seven years, 262 recumbent dairy cows were investigated, and serum samples were analysed for creatine phosphokinase (CPK), lactate dehydrogenase (LDH) and aspartate aminotransferase (AST) activities. The results from cows for which all three measurements were available, were analysed statistically by the non-parametric receiver operating characteristic (ROC) method, to evaluate the value of the serum enzyme activities for predicting a failure to recover. The sensitivity and specificity of the activity levels were calculated over all cut-off points, and ROC curves were created by plotting sensitivity as a function of 1--specificity at each cut-off point for samples grouped by the interval after the cows became recumbent. The predictive values of the tests were compared by calculating the areas under the curves, and the positive and negative predictive values of the tests were calculated and plotted against the prevalence of a failure to recover. The results from each of the enzymes were significantly better than from a random test with no discriminatory ability. The optimal cut-off points maximising the sensitivity and specificity of the tests were 2330, 2225 and 171 U/litre for CPK, LDH and AST, respectively. The predictive value of AST was significantly better than that of CPK or LDH, and measures made on the second and third day of recumbency were significantly better with optimal cut-off points of 128 and 189 U/litre, respectively.  相似文献   

14.
The aim of this study was to investigate the need for different cut-off points, according to animal age and the purpose of testing, for two of the most widely used serological techniques in bovine neosporosis, IFAT and a crude antigen ELISA (Civtest, HIPRA). Therefore, the population reference sera used were defined using a combination of multiple criteria such as epidemiological/clinical and histopathological parameters and an immunoblot test. Firstly, foetuses and breeding cattle (heifers and cows) were considered as separate subpopulations for serological evaluation. Secondly, cut-off points for each serological technique (IFAT and ELISA) according to age group (foetuses and breeding cattle) and the different practical applications (detection of infection and abortion) were calculated following the receiver operating characteristics (ROC) analysis. Cut-off points were defined, for IFAT and ELISA for aborted breeding cattle and for IFAT alone in the case of the foetuses, assuming an equivalent cost of false positive and negative results. In infected breeding cattle, for IFAT and ELISA and in foetuses for ELISA, two possible cut-off values were obtained, one for a maximum sensitivity and one for a maximum specificity and the intervals of unclear results were defined. In this case, a cut-off value for equal sensitivity and specificity was also estimated. When cut-off points for infected breeding cattle, 1:100-1:250 for IFAT and 0.306-0.451 for ELISA were applied to a target population, optimal and similar negative and positive predictive values together with similar apparent and true prevalence results were observed suggesting the possibility of using both tests interchangeably.  相似文献   

15.
旨在建立检测非洲猪瘟病毒(ASFV)血清抗体的阻断ELISA方法.采用原核表达的ASFVp54蛋白作为包被抗原,并制备了针对p54蛋白的单克隆抗体,采用方阵滴定法确定了阻断ELISA方法的最佳反应条件,并对建立的方法进行了敏感性、特异性、重复性和符合性评价.结果显示,抗原最佳包被浓度为2.0 μg·mL-1,抗原包被温...  相似文献   

16.
AIM: To determine the performance characteristics of an Institut Pourquier (IP) enzyme-linked immunosorbent assay (ELISA) for the detection of antibodies against Neospora caninum in bovine milk and subsequent determination of the prevalence of N. caninum infection in New South Wales (NSW) dairy cattle. METHODS: Matching serum and milk samples from 93 cattle were assayed in two commercially available ELISAs for the detection of anti-N. caninum antibodies. Serum test results of one ELISA (IDEXX) were used to determine the N. caninum infection status of the cattle. Optimised cut-off values for the IP ELISA using milk samples were determined by two-graph receiver operating characteristic (TG-ROC) analysis and then applied to a representative sample of 398 milk samples from dairy herds around NSW. RESULTS: When this ELISA was applied to a representative collection of 398 milk samples from dairy cattle across NSW it demonstrated a 21.1% prevalence of N. caninum infection in those cattle. From the TG-ROC analysis an IP ELISA protocol was derived which suggested a cut-off threshold that would allow milk testing with 97% sensitivity and specificity, respectively, relative to serum testing. CONCLUSIONS: The prevalence of N. caninum in NSW dairy cattle was higher than previously believed. When used on individual milk samples this ELISA demonstrated high sensitivity and specificity and so could be used to accurately identify N. caninum infection. TG-ROC analysis of the IP ELISA optimised the protocol and prescribed cut-off values enabling the ELISA to be used for the screening of N. caninum antibodies in the milk of dairy cattle.  相似文献   

17.
为建立更敏感、特异的牛片形吸虫病早期诊断方法,本试验将收集的大片吸虫分泌排泄产物(Fasciola gigantica excretory-secretory products,FgESP)进行凝胶过滤层析并从中筛选出检测效果最优的UV280吸收峰,从此峰对应的组分中筛选出诊断效果最优的层析组分后将其作为抗原,通过棋盘滴定试验优化抗原包被浓度、血清稀释度、酶标二抗稀释度、显色时间等,确定临界值,建立牛片形吸虫病间接ELISA诊断方法。对建立的方法进行敏感性和特异性试验,检测试验感染0~14周的水牛血清和临床160份水牛血清样本,并与已有的诊断抗原FgESP(阴阳临界值为0.320)进行诊断效果比较。结果显示,层析组分F22具有较优的检测效果。间接ELISA的最佳反应条件为:F22抗原包被浓度0.157 μg/mL,待测血清与酶标二抗的稀释度分别为1:400和1:40 000,显色时间为25 min。应用建立的方法检测15份水牛阴性血清,确定D450 nm阴阳性临界值为0.408。比较F22与FgESP发现,二者特异性相似,但F22作为抗原的敏感性高于FgESP。检测试验感染大片吸虫的水牛0~14周血清,结果表明,从感染第2周开始F22-IgG水平极显著高于FgESP-IgG水平(P<0.01),因此,F22比FgESP诊断效果更优。对160份水牛血清检测发现,F22阳性检出率为71.25%,FgESP阳性检出率为63.75%。上述结果表明,相比于FgESP,以F22作为诊断抗原建立的大片吸虫病间接ELISA诊断方法敏感性更高,可更有效地进行牛大片吸虫病的早期诊断。  相似文献   

18.
A reliable method was developed to produce a viral antigen preparation from porcine reproductive and respiratory syndrome virus (PRRSV) infected MARC-145 cells by solubilizing the virus with Triton X-100. This method eliminated problems previously encountered with high background reactions associated with PRRSV antigen or cell control antigen. With this new antigen, an indirect enzyme-linked immunosorbent assay (ELISA) was adapted to detect swine serum anti-body against PRRSV. In the ELISA, non-specific reactions associated with test serum samples have been eliminated by utilizing an effective blocking serum diluent. The ELISA is more sensitive than an indirect immunofluorescent assay (IFA), particularly with late-infection sera, while maintaining a high diagnostic specificity. In a comparison of IFA and ELISA using sera collected from 250 pigs of various ages from 5 herds that had PRRS histories, IFA revealed 178 positive samples and 72 negative samples. All of the IFA-positive sera were proven to be ELISA reactors. However, nearly one-half (34/72) of the IFA-negative samples were also ELISA reactors. The diagnostic specificity and sensitivity of the ELISA were 100% and 96.6% with 257 serum samples collected from known healthy PRRS-negative swine herds and 57 sera collected from infected swine at 6 to 56 days after infection, respectively. The ELISA is technically superior to IFA, time-efficient and cost-effective, and suitable for testing of a large number of samples over a short period of time.  相似文献   

19.
A fluorescence polarization assay (FPA) was used to test whole blood samples prepared by mixing blood cells from cattle without exposure to Brucella abortus (B. abortus) with sera from animals with confirmed (bacteriologically) infection. A cut-off value between negative and positive values was initially established to be 87.2mP. This value was changed to 95mP to increase assay specificity without loss of sensitivity when testing blood samples from negative animals. The FPA technology was applied to whole blood samples in the field and to stored whole blood samples using two diluent buffers. Relative sensitivity and specificity values for the FPA performed in the field, based on buffered antigen plate agglutination test and competitive enzyme immunoassay results were 95.3 and 97.3%, respectively. However, to obtain maximum sensitivity and specificity, a cut-off value of 105mP was determined for fresh whole blood samples. The relative sensitivity and specificity values of the FPA when testing stored whole blood samples were 100% each using a 95mP cut-off.The usefulness of the FPA for testing whole blood samples in the field was demonstrated.  相似文献   

20.
AIM: To describe the performance characteristics (sensitivity and specificity) of an enzyme-linked immunosorbent assay (ELISA) for the diagnosis of Brucella ovis infection in rams. METHODS: Sera from a negative (n = 2535) and a positive (n = 589) reference population were tested in an ELISA for anti-B. ovis antibodies and cut-off values calculated from the raw, log10-transformed and fitted data. Statistical methods were used to fit curves to the frequency distribution of the data and receiver-operated characteristics analysis used to optimise the cut-off values. RESULTS: Analysis of the frequency distribution of the positive ELISA values suggested a normal distribution of the data, whereas, in the case of the negative population, a Pearson type IV curve appeared to best fit the data. The cut-off values calculated as the mean plus 1.96 standard deviations (s.d.) from the raw, log-transformed and fitted ELISA data did not differ markedly. The differences were much greater at the mean plus 3.09 s.d. cut-off, with the cut-off value calculated from the log-transformed data giving a much better estimate of specificity. Optimisation (minimisation of classification error) of the cut-off calculated from the fitted curves suggested varying cut-off values, depending on the prevalence of B. ovis infection. Discussion: Calculation of cut-off values from curves that were fitted from the observed data give more accurate estimations of the performance characteristics of an assay than traditional calculations from observed values. They also allow the calculation of optimal cut-off values taking into account the prevalence of B. ovis infection and give additional information about the performance of the assay at cut-off values varied according to the epidemiological situation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号