首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The objective of this retrospective study is to determine normal reference values for 2-Dimension (2D) and Motion-mode (M-mode) echocardiographic parameters in nonsedated healthy young adult Sphynx cats and to compare them to those of the domestic shorthair (DSH). 131 Sphynx cats underwent cardiac screening prior to breeding. The control group consisted of 30 healthy adult domestic cats. A complete cardiac ultrasound was performed on all cats using right parasternal long and short axis views. There were few echocardiographic parameters in the Sphynx that differed from those of the healthy DSH. Only the left atrial (LA) dimension in 2D and M-mode, the left atrial/aortic (LA/Ao) ratio and the internal dimension of the left ventricle in systole (LVIDs) measured with M-mode were different. In conclusion, although the heart of Sphynx cat can often have a particular 2-D echocardiographic appearance, the M-mode cardiac dimensions are similar to those of the DSH.  相似文献   

2.
ObjectivesTo investigate the dependence of echocardiographic ratio indices (ERIs) on age, body weight (BW) and breed/study group using individually contributed and published summarized data in dogs.BackgroundERIs allow for narrow prediction intervals of M-mode echocardiographic measurements in generic adult dogs. Breed and age-specific differences have not been examined systematically using ERI methods.Animals, materials and methodsIndividual M-mode measurements were contributed by 15 published investigators from 661 dogs, allowing direct calculation of ERIs and summary statistics for each of these breed/study groups. M-mode ERI summary statistics were estimated from published summaries of 22 additional groups that included 527 adult and 36 growing dogs. Individual two-dimensional (2DE) left atrial (LA) and aortic root (Ao) measurements were contributed from 36 dogs. ERIs were analyzed for dependence on BW, breed/study group and age.ResultsThe majority of variation among ERIs was due to differences in the breed or study technique with comparatively little dependence on BW. Age dependence of ERIs was seen in the early growth phases of young dogs, but expected values for each ERI became static long before maturity, roughly at 10–12 weeks of age. ERIs derived from individual 2DE LA and Ao measurements showed no significant dependence on BW.ConclusionsERIs are well normalized for body size and may be useful for clinical evaluation of individuals, prediction of expected M-mode and 2DE cardiac dimensions, and investigation of age or breed-specific cardiac shape changes.  相似文献   

3.
ObjectivesTo compare dimensions and shortening fraction (SF) of the left ventricle (LV) obtained from two-dimensional (2D) and M-mode imaging of short and long-axis views.Animals40 healthy, adult German Shepherd dogs.MethodsLeft ventricular measurements were obtained using 4 echocardiographic methods: M-mode in short and long-axis and 2D imaging in short and long-axis. The methods were compared by studying the effects of imaging mode and axis on LV parameters, taking into account the influence of weight and gender.ResultsMean LV end-diastolic diameter was greater in short-axis views. However, this difference was not considered clinically relevant. Mean SF was higher when derived from 2D measurements with poor agreement among methods. A combined influence of axis, gender, and weight was observed on interventricular septal thickness in end diastole with poor agreement among methods.ConclusionsSome LV parameters were significantly affected by mode and axis, either in isolation or in combination with weight and gender, although the differences observed were not always clinically relevant. These findings show that using the different echocardiographic methods interchangeably to assess LV dimensions should be done with caution.  相似文献   

4.
Anatomic M-mode (AMM) is an echocardiographic technique that is capable of generating M-mode studies from two-dimensional (2D) cine loops. Unlike conventional M-mode (CMM) whose scan line must lie along the axis of the ultrasound signal, AMM produces M-mode studies independent of the orientation of the ultrasound beam. We sought to determine the ability of AMM to measure cardiac dimensions in normal dogs and to assess the accuracy and variability of AMM and CMM vs. 2D measurements. Thirty-eight healthy dogs underwent physical exam and 2D, CMM, and AMM echocardiographic studies. The end-diastolic and end-systolic dimension of the left ventricle and the diameter of the left atrium (LAD) and aortic root were evaluated from the right parasternal short- and long-axis views. Results of the AMM and CMM study were compared with the 2D study via linear regression and calculation of a coefficient of correlation. AMM increased the level of correlation with both the left ventricular dimensions and LAD. Bland-Altman analysis revealed that AMM increased the level of agreement with 2D measurements and CMM greatly underestimated LAD vs. AMM. In healthy dogs, cardiac AMM measurements are associated with greater accuracy and less variability than CMM. AMM has the potential to improve quantification of cardiac dimensions.  相似文献   

5.
The growth of the heart, relative to body weight, was measured by M-mode echocardiography in dogs during the first year of life. Echocardiographic measurements were obtained from 16 English Pointers at 1, 2, 4, and 8 weeks of age and at 3, 6, 9, and 12 months of age. Left atrial (LA), aortic (AO), left and right ventricular internal dimensions, interventricular septal and left ventricular wall thickness measurements increased in curvilinear fashion relative to increasing body weight. Least-squares regression analysis, performed on logarithmically transformed data, was used to develop power-law equations describing the relationship of echocardiographic measurements to body weight. Linear dimensions of the LA, AO, left and right ventricular internal dimensions and interventricular septal and left ventricular wall thickness changed proportionally to slightly differing exponential powers of body weight (BW), varying from 0.31 to 0.45 (BW0.31 to BW0.45). Fractional shortening and the LA to AO ratio decreased slightly, but significantly, as body weight increased. Indexing echocardiographic measurements to BW1/3 was more appropriate than indexing such measures linearly to body weight, offering a practical method for developing accurate normative graphs or tables for M-mode echocardiographic dimensions in growing dogs.  相似文献   

6.
Atrial size determined by echocardiography provides a surrogate measure of the hemodynamic burden of cardiac disease. Linear atrial dimensions often are indexed to aortic diameter. Whereas quantitative variables obtained from healthy cats, using 2-dimensional echocardiography (2DE), have been reported, indices from 2DE, have not. Using 2DE and M-mode echocardiography, we calculated indices of left atrial size and a single index of atrial function, left atrial fractional shortening, in 17 healthy cats. Specifically, left atrial dimensions from short- and long-axis 2DE planes were indexed to aortic diameter and also to end-diastolic left ventricular dimension. Additionally, left atrial circumference and area were indexed to aortic circumference and area, respectively. The same variables were obtained from 20 cats with hypertrophic cardiomyopathy (HCM), so that agreement between 2DE indices and indices from M-mode echocardiography could be evaluated over a clinically relevant range of atrial sizes. Atrial dimensions and indices of atrial size from cats with HCM exceeded those of healthy cats. Left atrial dimension from 2D short-axis images indexed to aortic diameter generally was less than the analogous index obtained from M-mode (mean bias, [95% limits of agreement] -0.13, [-0.42, 0.17]). Left atrial dimension from 2D long-axis images indexed to aortic diameter generally was greater than the index obtained from M-mode (0.15, [-0.28, 0.58]). We conclude that ratios of left atrial size and aortic diameter, from 2DE and M-mode echocardiography, are not interchangeable. Normative data that may serve as reference intervals for 2DE assessment of atrial size are presented.  相似文献   

7.
Background: Real‐time 3‐dimensional echocardiography (RT3D) is a recent technique based on volumetric scanning, eliminating the need for geometric modeling of the cardiac chambers and minimizing the errors caused by foreshortened views. Hypothesis: Estimations of left ventricular (LV) end‐diastolic (EDV) and end‐systolic volume (ESV), and left atrial (LA) size, differ depending on the echocardiographic technique of estimation. Animals: Fifty‐one dogs with acquired heart disease and 34 healthy control dogs. Methods: Prospective observational study by M‐mode (Teichholz method), Simpson's modified 2‐dimensional (2D) method, and RT3D methods for estimation of LV volumes. LA size was evaluated by 2D and RT3D methods. Results: RT3D showed good agreement with 2D for EDV and ESV, whereas Teichholz method overestimated LV volumes in comparison with the other 2 methods by approximately a factor 2. There were no statistically significant differences among the 3 methods in estimating ejection fraction. Comparison between RT3D assessment of LA end‐systolic volume per kilogram (LAs/kg) and LA to aortic ratio (LA/Ao) measured by 2D relative to each other showed that the RT3D method underestimated LAs/kg at lower values, and overestimated it at higher values. The difference between methods increased with increasing LA size. Conclusions and Clinical Importance: There was good agreement between RT3D and 2D methods of estimating EDV and ESV, whereas the Teichholz method overestimated LV volumes by approximately a factor 2. In comparison with RT3D, LA/Ao underestimated LA size, especially when LA was enlarged.  相似文献   

8.
Echocardiography has become a routine non-invasive cardiac diagnostic tool in most species. Accurate measurement of cardiac dimensions requires reference values, which are poorly documented in goats. The aim of the present study was to test the inter-day repeatability and to establish the reference values of two-dimensional (2D-) and time-motion (M-) mode echocardiographic variables in healthy adult Saanen goats. Six goats were investigated three times by the same observer at one-day interval using a standardised 2D- and M-mode echocardiographic protocol. The intra-observer inter-day repeatability was tested using analysis of variance, calculation of the coefficient of variation and confidence intervals. A single echocardiographic examination was performed in six other goats, and values obtained in the 12 goats were used to establish the 2D- and M-mode echocardiographic reference values in healthy adult female Saanen goats. Statistical analysis revealed a good inter-day repeatability of the echocardiographic cardiac measurements. Echocardiographic reference values obtained in healthy adult Saanen goats seemed slightly higher than those reported in healthy Swedish domestic goats and were similar to those reported in healthy adult sheep.  相似文献   

9.
The objective of this study was to compare the repeatability of echocardiographic measurements obtained from different echocardiographic modes and views in healthy adult equids of various sizes, breeds, and thorax shapes. Ten equids (body weight: 120–662 kg; age: 1–26 years) from various breeds, free of cardiac disease, were used in this study. Each animal was submitted to a standardized echocardiographic and Doppler protocol 3 times at 1 day interval. This protocol included the measurements of left and right ventricular, aortic, pulmonary, and left atrial parameters obtained from different views using the bidimensional (2D) or the motion (M) modes, and the measurement of several parameters of blood flow obtained from the pulsed wave Doppler mode. Repeatability of each measurement was estimated on the basis of the residual variance using a linear model and the coefficient of variation of repeated measurements. A two by two comparison of the repeatability of measurements performed in different views was performed using the residual variances in a variance ratio F test. Results showed that repeatability of echocardiographic or Doppler measurements in equids of various sizes, breeds, and thorax shapes are comparable to previously reported results in thoroughbred and standardbred horses. Left ventricular morphologic parameters showed a good repeatability in the classic M-mode right parasternal short axis view at the level of the chordae tendineae, but the 2D-mode right parasternal long axis four-chamber view appeared to offer an interesting alternative measurement. This latter view also allowed obtaining the most repeatable measurement of right ventricular internal diameter. The left atrial diameter was maximal and most repeatable in the 2D-mode left parasternal long axis four-chamber angled view, and the repeatability of the aortic diameter was best in the 2D-mode right parasternal long axis five-chamber view. Finally, aortic systolic time intervals were more repeatable when measured from the Doppler mode as compared with the M-mode. In conclusion, repeatability of echocardiographic measurements in horses could be optimized after the following protocol: (1) M-mode right parasternal short axis view at the level of chordae tendineae to measure left ventricular morphologic parameters, and 2D-mode right parasternal long axis four-chamber as an alternative view; (2) 2D-mode right parasternal long axis five-chambers to measure the aortic diameter; (3) 2D-mode left parasternal long axis four-chambers angled view to measure the left atrial diameter.  相似文献   

10.
This study was initiated to determine the accuracy of M-mode echocardiography in measuring left ventricular dimensions and estimating heart weights in horses. Left ventricular free wall and interventricular septal thickness and left ventricular external and internal diameters were measured and heart weights estimated from the echocardiograms of 47 horses. Autopsy measurements of the same parameters were then recorded. Statistical comparison of the data demonstrated: (1) Systolic measurements of wall thickness more closely resembled the heart in death than the diastolic measurements; (2) good correlations existed between parameters measured echocardiographically and at autopsy, especially wall thicknesses and left ventricular external diameter (maximum r = 0.82); (3) heart weight was readily predicted from echocardiographic wall thickness regressions (maximum R-squared = 68 per cent). M-mode echocardiography demonstrated the potential for direct and accurate measurements of cardiac mass and some ventricular dimensions in the horse. The data suggested that intense rigor and exsanguination may render the autopsied heart unsatisfactory for comparative measurements when assessing techniques such as echocardiography.  相似文献   

11.
Kerstin  Hansson  DVM  Jens  Häggström  DVM  PhD  Clarence  Kvart  DVM  PhD  Peter  Lord  BVSc  FRCVS 《Veterinary radiology & ultrasound》2002,43(6):568-575
Two-dimensional (2-D) echocardiographic measurement of the left atrium (LA) has the potential to be more accurate than the standard M-mode method, because the LA body can be measured. We evaluated a 2-D method for measuring LA and aorta (AO) in a right parasternal short-axis view and compared it to the M-mode method. An index for LA size (LA/AO) was calculated in 166 cavalier King Charles spaniels, 56 normal and 110 dogs with mitral regurgitation (MR) of varying degrees secondary to chronic valvular disease. In normal dogs, the AO-2-D and LA/AO-2-D did not correlate to body weight (BW) or BW2; whereas, all M-mode values and the LA-2-D were significantly (p < .05) related to both BW parameters. In normal dogs, there was no difference between M-mode and 2-D indices. For all dogs (normal and dogs with MR) there was an 11% bias between the M-mode and 2-D index with the LA/AO-2-D being higher than the LA/AO-M. The association between the mean and the difference of the indices demonstrated a quadratic relationship. Dogs with a mean LA/AO of 2.0-2.5 showed the largest difference between the two indices. Small values for the 2-D coefficients of variation for respiration and stage of diastole were found; 3.4 and 3.1%, respectively. The 2-D index is more sensitive to LA enlargement than the M-mode index.  相似文献   

12.
OBJECTIVE: To determine whether logarithmic and polynomial models are superior to simple linear models for predicting reference values for M-mode echocardiographic variables in dogs with a wide range of body weights. ANIMALS: 69 apparently healthy adult male and female dogs of various breeds, ages (range, 1 to 12 years; median, 3.5 years), and body weights (range, 3.9 to 977 kg; median, 25.4 kg). PROCEDURE: Echocardiographic M-mode measurements of the interventricular septum, left ventricular dimension (LVD), left ventricular wall, aorta, and left atrium were obtained. Simple linear, second-order polynomial, third-order polynomial, and logarithmic regression models were determined by use of the least-squares method to describe the relationship between M-mode measurements and body weight. Differences in adjusted R2 values of logarithmic and polynomial models were tested for significance of contribution, compared with the simple linear model. RESULTS: Significant differences in adjusted R2 were found when comparing simple linear with logarithmic or polynomial models for LVD-diastole, LVD-systole, aorta, and left atrium. Differences in adjusted R2 between second-order polynomial, third-order polynomial, and logarithmic models were not significant for any M-mode measurement. CONCLUSIONS AND CLINICAL RELEVANCE: In this study, logarithmic or second-order polynomial models predicted reference values of M-mode measurements for size of the cardiac chambers better than simple linear models for dogs with a wide range of body weights. Logarithmic and polynomial models were not superior to simple linear models for M-mode measurements of cardiac wall thickness.  相似文献   

13.

Objectives

To provide reference intervals for 2-dimensional linear and area-based estimates of left atrial (LA) function in healthy dogs and to evaluate the ability of estimates of LA function to differentiate dogs with subclinical myxomatous mitral valve disease (MMVD) and similarly affected dogs with congestive heart failure (CHF).

Animals

Fifty-two healthy adult dogs, 88 dogs with MMVD of varying severity.

Methods

Linear and area measurements from 2-dimensional echocardiographs in both right parasternal long and short axis views optimized for the left atrium were used to derive estimates of LA active emptying fraction, passive emptying fraction, expansion index, and total fractional emptying. Differences for each estimate were compared between healthy and MMVD dogs (based on ACVIM classification), and between MMVD dogs with subclinical disease and CHF that had similar LA dimensions. Diagnostic utility at identifying CHF was examined for dogs with subclinical MMVD and CHF. Relationships with bodyweight were assessed.

Results

All estimates of LA function decreased with increasing ACVIM stage of mitral valve disease (p<0.05) and showed negative relationships with increasing LA size (all r2 values < 0.2), except for LA passive emptying fraction, which did not differ or correlate with LA size (p=0.4). However, no index of LA function identified CHF better than measurements of LA size. Total LA fractional emptying and expansion index showed modest negative correlations with bodyweight.

Conclusions

Estimates of LA function worsen with worsening MMVD but fail to discriminate dogs with CHF from those with subclinical MMVD any better than simple estimates of LA size.  相似文献   

14.
OBJECTIVE: To evaluate changes over time in echocardiographic measurements in young Standardbred racehorses undergoing training and racing and determine whether there was any relationship between cardiac dimensions and racing performance. DESIGN: Longitudinal observational study. ANIMALS: 103 horses. PROCEDURE: 2-dimensional and M-mode echocardiography was performed 4 times at 6-month intervals. RESULTS: Significant cardiac enlargement took place during the study period as indicated by increases in left ventricular internal diameter in diastole (LVIDd), estimated left ventricular muscle mass (LV mass), and mean wall thickness attributable to eccentric left ventricular hypertrophy. Estimated body weight was positively correlated with left ventricular size, and males had significantly larger LVIDd and LV mass than did females. Horses that were racing regularly had larger LVIDd and LV mass than did unraced horses. A significant relationship between left ventricular size and racing performance was observed. The relationship was strongest at the time of the fourth examination. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that age must be taken into account when interpreting results of echocardiography in young Standardbred racehorses because significant cardiac enlargement takes place with age and training. A larger heart was found in horses that were racing, and size of the heart was correlated with athletic performance of the horse.  相似文献   

15.
OBJECTIVE: To assess the feasibility, describe the techniques, and determine the reliability of transthoracic echocardiography for characterization of left atrial (LA) size and LA mechanical function in horses. ANIMALS: 6 healthy adult horses. PROCEDURES: Repeated echocardiographic examinations were performed independently by 2 observers in standing, unsedated horses by use of 2-dimensional echocardiography, pulsed-wave flow Doppler, and tissue Doppler imaging (TDI) techniques. Test reliability was determined by estimating measurement variability, within-day interobserver variability, and between-day inter- and intraobserver variability of all echocardiographic variables. Variability was expressed as the coefficient of variation (CV) and the absolute value below which the difference between 2 measurements will lie with 95% probability. RESULTS: Most echocardiographic variables of LA size had low overall variability (CV, < 15%). Among the 2-dimensional indices of LA mechanical function, area-based and volume-based ejection phase indices had moderate between-day variability (CV usually < 25%). Transmitral Doppler flow indices were characterized by low to high between-day variability (CV, 6% to 35%). The TDI wall motion velocities had high between-day variability (CV, > 25%), whereas most TDI-derived time intervals had low variability (CV, < 15%). CONCLUSIONS AND CLINICAL RELEVANCE: LA size and mechanical function can be reliably assessed in standing, unsedated horses by use of 2-dimensional echocardiography, transmitral blood flow velocity profiles, and analyses of LA wall motion by use of TDI. These results may provide useful recommendations for echocardiographic assessment of LA size and function in horses.  相似文献   

16.
BACKGROUND: Boxer dogs are routinely screened by echocardiography to exclude congenital and acquired heart disease. Individuals of a given breed may span a large range of body sizes, potentially invalidating linear regression of M-mode measurements against body weight. Echocardiographic ratio indices (ERIs) provide a novel method of characterizing echocardiographic differences between Boxers and other dog breeds. HYPOTHESIS: ERIs obtained from overtly healthy Boxer dogs presented for cardiac screening will be different from ERIs established for normal non-Boxer dogs, and those differences will be unrelated to aortic velocity or systolic blood pressure. ANIMALS: Eighty-one Boxers with no outward clinical signs of heart disease were studied. METHODS: All dogs were examined by 2-dimensional, M-mode, and Doppler echocardiography. M-mode measurements were used to perform ERI calculations, and the indices in Boxers were compared between Boxers with varying severity of arrhythmia and those of normal non-Boxer dogs. RESULTS: Differences in weight-based ERIs, which reflect increased thickness of the left ventricular free wall (LVW) and interventricular septum (IVS) and smaller aortic size, were found in overtly healthy Boxer dogs compared with normal non-Boxer dogs. ERIs of left atrial and LV cavity size in overtly healthy Boxers were not significantly different from those of non-Boxer dogs. CONCLUSIONS AND CLINICAL IMPORTANCE: Boxer dogs may have an increased relative thickness of the LVW and IVS that is independent of aortic size, aortic velocity, or arterial blood pressure, and this morphology should be taken into consideration when screening Boxers by echocardiography.  相似文献   

17.
ObjectivesThe objectives of this study were (1) to assess the potential effect of body weight (BW), age, and gender on the most commonly used echocardiographic and conventional Doppler variables in a large population of healthy Cavalier King Charles Spaniels (CKCS), and (2) to establish the corresponding reference intervals (RI).Animals134 healthy adult CKCS.MethodsUltrasound examinations were performed by trained observers in awake dogs. M-mode variables included left ventricular (LV) end-diastolic and end-systolic diameters, LV free wall and interventricular septal thicknesses at end-diastole and end-systole, and LV fractional shortening (FS%). The left atrium (LA) and aortic (Ao) diameters were measured using a 2D method, and the LA/Ao was calculated. Pulsed-wave Doppler variables included peak systolic aortic and pulmonary flow velocities, mitral E and A waves, and E/A ratio. Effects of BW, age, and gender on these 15 variables were tested using a general linear model, and RIs were determined by applying the statistical procedures recommended by the Clinical and Laboratory Standards Institute.ResultsA significant BW effect was observed for all variables, except LA/Ao, FS%, and mitral E/A ratio. A significant but negligible effect of gender and age was also observed for 5/15 and 4/15 of the tested variables, respectively. Only the BW effect on M-mode variables was considered as clinically relevant and the corresponding regression-based RIs were calculated.ConclusionsBody weight should be taken into account when interpreting echocardiographic values in CKCS, except for LA/Ao, FS%, and mitral E/A ratio.  相似文献   

18.
M-mode and Doppler echocardiographic values were obtained from 30 normal adult ferrets (14 neutered females, 13 neutered males, 3 intact males) sedated with an intramuscular combination of ketamine hydrochloride and midazolam. Routine M-mode measurements of the left and right ventricle, left atrium (LA) and aorta (AO) and Doppler measurements of aortic and pulmonic outflow, and mitral inflow were recorded. The following values were calculated: LA:AO diameter, ratio of peak E: peak A wave velocity (E:A ratio) for mitral inflow, and stroke volume (SV), cardiac output (CO) and cardiac index (CI) for both pulmonary and aortic outflow tracts. Maximal aortic velocities (AOmax) and velocity-time integral values (AO VTI) were significantly less than corresponding pulmonary outflow tract values (PAmax, PA VTI) but there was no difference in calculated values for SV, CO or CI. Calculated CO values were in the range expected based on the size of the species. Difficulties in aligning the aortic outflow tract for Doppler imaging may make pulmonary outflow Doppler values more consistent for use in estimating volume flow in ferrets.  相似文献   

19.
IntroductionThe objective of the study was to evaluate the accuracy of two- and three-dimensional (2D, 3D) transthoracic echocardiography (TTE), 2D transesophageal echocardiography, and computed tomography angiography (CTA) compared with cardiac magnetic resonance imaging (CMR) in normal dogs and to assess repeatability of 2D and 3D TTE for the assessment of left ventricular (LV) and left atrial (LA) dimensions.AnimalsThe study was performed on six healthy dogs.Materials and MethodsTransthoracic echocardiography, transesophageal echocardiography, CTA, and CMR were performed on each dog. Right ventricular (RV) and LV volumes (in systole and diastole), ejection fraction (EF), and LA and right atrial (RA) volumes were assessed. Repeatability and intrarater and interrater measurements of variability were quantified by average coefficient of variation (CV) for 2D and 3D TTE.ResultsNo clinically relevant differences in LV volume were detected between CMR and all modalities. Importantly, 3D TTE had the lowest CV (6.45%), correlated with (rs = 0.62, p = 0.01), and had the highest overlap in distribution with CMR (OVL >80%). Left ventricular EF and LA size via CTA compared best with CMR and RV and RA volumes were best estimated by 3D TTE. Assessment of LV and LA volumes via 3D TTE had moderate repeatability (15–21%) compared with LV M-mode measurements and 2D LA-to-aortic ratio (<10%), respectively. For LV size, interrater CV for 3D TTE (19.4%) was lower than 2D TTE (23.1%).ConclusionsMeasurements of LV, RV, and RA volumes via 3D TTE and LA volume and LV EF assessed by CTA compared best with CMR. Three-dimensional echocardiography had lower interrater and intrarater CV compared with 2D TTE.  相似文献   

20.
Allometric scaling of M-mode cardiac measurements in normal adult dogs   总被引:1,自引:0,他引:1  
Indices for M-mode measurements in dogs usually have been based on the assumption that a linear relationship exists between these measurements and body weight (BW) or body surface area (BSA). The relationships between the geometry of 3-dimensional objects do not support this assumption. The purposes of this study were to retrospectively examine M-mode data from a large number of dogs of varying sizes and breeds that were examined by a large number of ultrasonographers, to use the allometric equation to determine the appropriate BW exponent required to predict these cardiac dimensions, and to determine normal mean values and prediction intervals for common M-mode variables. Linear regression analyses of data from 494 dogs (2.2-95 kg) revealed a good correlation between M-mode measurements and BW after logarithmic transformation of the data (r2 = .55-.88). Most variables were most closely related to an index of body length, BW(1/3), although the exponent that best predicted diastolic and systolic left ventricular wall thicknesses was closer to 0.25. No variable indexed well to BW or BSA. With these data, appropriate mean values and prediction intervals were calculated for normal dogs, allowing veterinarians to correctly and appropriately index M-mode values. The equations developed from this study appear to be applicable to adult dogs of most breeds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号