首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Arterial blood pressure measurements were obtained from 158 healthy Irish wolfhounds using the oscillometric technique to establish reference values for the breed. In contrast to other sight hounds, Irish wolfhounds have low arterial blood pressure. Mean systolic pressure for the group was 116.0 mm Hg. Mean diastolic pressure was 69.2 mm Hg, and the mean value for mean arterial pressure was 87.8 mm Hg. Blood pressure measurements were higher in older wolfhounds than in young dogs. There was no difference between systolic and mean arterial blood pressures in lateral recumbency compared to standing position. However, diastolic pressure was slightly lower when standing. Calm dogs had lower pressure than anxious wolfhounds. There was a significant interaction between the effects of age, gender, and mood on systolic, diastolic, and mean arterial blood pressure values.  相似文献   

2.
OBJECTIVE: To determine arterial blood pressure in client-owned dogs, using direct arterial puncture, oscillometry, and Doppler ultrasonography in a clinical setting. DESIGN: Prospective study. ANIMALS: 8 clinically normal client-owned dogs. PROCEDURE: Blood pressures of nonsedated dogs were measured simultaneously, using each of the 3 methods. Mean values obtained were compared with published mean values. Ability of noninvasive methods (Doppler ultrasonography and oscillometry) to accurately predict results of the invasive method, and relationships between blood pressure and age, body weight, and degree of patient anxiety were determined. RESULTS: Calculated ranges of values (mean +/- 2 SD) determined by direct arterial puncture were: systolic pressure, 114 to 194 mm Hg; diastolic pressure, 66 to 102 mm Hg; and mean pressure, 85 to 129 mm Hg. Ranges determined by use of oscillometry were: systolic, 110 to 190 mm Hg; diastolic, 35 to 107 mm Hg; and mean, 78 to 138 mm Hg. Ultrasonographic and oscillometric values did not accurately predict direct values, but mean values of systolic and mean pressures were similar among methods. Relationships were not detected between age or body weight and blood pressure. Significant differences in blood pressure were not detected between anxious and nonanxious dogs. CONCLUSIONS AND CLINICAL RELEVANCE: Mean values of systolic, diastolic, and mean arterial blood pressure measured in nonsedated client-owned dogs, using invasive and noninvasive methods in a clinical setting, are comparable with those determined for acclimatized, trained, or sedated dogs. However, results of noninvasive methods may not accurately reflect direct values.  相似文献   

3.
Adaptation of human oscillometric blood pressure monitors for use in dogs   总被引:2,自引:0,他引:2  
Two digital oscillometric human blood pressure measuring devices were modified and evaluated as blood pressure monitors in 12 healthy anesthetized dogs. Direct arterial pressures were measured via cannulation of the dorsal pedal artery and were correlated with indirect measurements through an inflatable cuff placed over the dorsal pedal artery below the hock joint of the contralateral limb. Direct and indirect measurements were compared for systolic, diastolic, and calculated mean arterial pressures. Blood pressure ranges between 215/145 mm of Hg and 65/30 mm of Hg were obtained, using combinations of halothane, phenylephrine, calcium, and IV administered fluids. Machine A was found to be insufficient for clinical application, on the basis of correlation coefficients between direct and indirect pressures of 0.78, 0.65, and 0.74 for systolic, diastolic, and mean arterial pressures, respectively. Higher correlation coefficients between direct and indirect pressures (0.77, 0.87, and 0.87, respectively) were obtained with machine B. The results of the study reported here suggest machine B may be an effective blood pressure monitoring device in anesthetized dogs.  相似文献   

4.
CASE DESCRIPTION: A 5-year-old male German Shepherd Dog was evaluated because of a 5-month history of progressive lethargy, weight loss, and heart failure. CLINICAL FINDINGS: On physical examination, bounding femoral pulses and systolic and diastolic murmurs were detected. Echocardiography revealed severe aortic valve insufficiency (AVI) and a large vegetative lesion on the aortic valve consistent with aortic valve endocarditis. The AVI velocity profile half-time was 130 milliseconds; the calculated peak systolic pressure gradient across the aortic valve was 64 mm Hg. Left ventricular diameter during diastole was 63.6 mm (predicted range, 40.2 to 42 mm) and during systole was 42.9 mm (predicted range, 25.4 to 27 mm). Systolic, diastolic, and mean arterial blood pressures were 120, 43, and 65 mm Hg, respectively. TREATMENT AND OUTCOME: To palliate severe AVI, the descending aorta was occluded (duration, 16.75 minutes) and heterotopic implantation of a porcine bioprosthetic heart valve in that vessel was performed. After surgery, systolic, diastolic, and mean arterial blood pressures were 115, 30, and 61 mm Hg, respectively, in the forelimb and 110, 62, and 77 mm Hg, respectively, in the hind limb. Within 6 months, the AVI velocity profile half-time had increased to 210 milliseconds, indicating diminished severity of AVI. After 24 months, the dog was able to engage in vigorous exercise; no pulmonary edema had developed since surgery. CLINICAL RELEVANCE: Heterotopic bioprosthetic heart valve implantation into the descending aorta during brief aortic occlusion appears feasible in dogs and may provide substantial palliation for dogs with severe AVI.  相似文献   

5.
Objective – To compare blood pressure measurements obtained via ultrasonic Doppler flow monitor (DOP) and 2 oscillometric noninvasive blood pressure monitors (CAR and PAS) to invasive blood pressure (IBP) in hospitalized, conscious dogs with a range of blood pressures. Design – Prospective clinical study. Setting – University teaching hospital. Animals – Eleven client‐owned dogs aged between 4 months and 11.5 years (median 6 y), and weighing between 5.8 and 37.5 kg (median 30.2 kg). Interventions – Blood pressure measurement. Measurements and Main Results – Three consecutive measurements of systolic, diastolic, and mean arterial pressure (MAP) were recorded for each of the 3 indirect devices (only systolic for DOP), along with concurrent IBP measurements. The data were categorized into 3 groups: hypotensive (direct MAP<80 mm Hg), normotensive (80 mm Hg≤direct MAP≥100 mm Hg), and hypertensive (direct MAP>100 mm Hg). Each indirect method was compared with the corresponding direct arterial pressure using the Bland‐Altman method. Within the hypotensive group, each indirect method overestimated the corresponding IBP. Within the normotensive group all indirect systolic measurements and the PAS diastolic measurements underestimated the corresponding IBP. The remaining indirect measurements overestimated the corresponding IBP. Within the hypertensive group, DOP and CAR systolic measurements underestimated the corresponding IBP, and the remaining indirect measurements overestimated the corresponding IBP. In hypertensive dogs oscillometric systolic measurements were more accurate than MAP. In hypotensive dogs MAP measurements were more accurate than systolic measurements. All indirect measurements were most accurate in hypertensive dogs. Conclusions – The noninvasive blood pressure monitors in our study did not meet the validation standards set in human medicine. However, CAR diastolic and MAP measurements within the normotensive group, CAR MAP measurements within the hypertensive group, and PAS diastolic measurements in all groups were close to these standards. All indirect measurements showed greater bias during hypotension. Precision was poorer for all indirect systolic measurements than for MAP.  相似文献   

6.
Objective This study was conducted to evaluate the performance of a new veterinary oscillometric noninvasive blood pressure (NIBP) monitor in anesthetized dogs. Study design Assessment was made to determine how closely indirect measurements were associated with direct measurements, and if there were statistically significant differences between the measurements by site. Animals Six mongrel dogs weighing 27.8 ± 2.9 kg. Methods Dogs were anesthetized with thiopental and maintained with isoflurane, which was delivered with controlled ventilation. Direct pressure measurements were obtained via a percutaneously placed arterial catheter. A range of systolic arterial pressures (SAP) were achieved by changing the isoflurane concentrations. Sites of cuff placement for indirect measurements were identified as metacarpus, metatarsus, and anterior tibial. Results At pressures below 80 mm Hg, indirect systolic measurements averaged 4 ± 3 mm Hg, higher than the direct values. At normal and high levels, indirect systolic measurements underestimated direct values by 18 ± 6 and 23 ± 6 mm Hg, respectively. Diastolic and mean pressure measurements followed the same trend, with indirect values being lower than the direct arterial pressures. Systolic, diastolic and mean arterial pressure measurements differed by cuff‐placement site. Conclusions When analyzed by site and level, indirect systolic and mean arterial blood pressures during hypotension were essentially the same as direct pressures. However, at pressures within the normal or high range, indirect measurements underestimated the direct pressures. Clinical relevance Noninvasive blood pressure measurements with a new oscillometric monitor provided an excellent means of detecting arterial hypotension in anesthetized dogs. The metatarsal site for cuff placement was slightly better than the metacarpal or anterior tibial site, considering that the regression line was closest to complete equality between the indirect and direct measurements for SAP.  相似文献   

7.
OBJECTIVE: To determine whether there was an association between hypertensive retinopathy and high systolic, diastolic, and mean arterial blood pressures in cats. ANIMALS: 181 cats. PROCEDURE: Systolic, diastolic, and mean arterial blood pressures were measured by use of a noninvasive oscillometric technique. The range of blood pressure measurements in healthy cats from various age groups was determined. Associations among systolic, diastolic, and mean arterial blood pressure; hypertensive retinopathy; hyperthyroidism; left ventricular cardiac hypertrophy; chronic renal failure; and serum biochemical abnormalities were determined. RESULTS: All blood pressure measurements increased with age in healthy cats. The frequency of hypertensive retinopathy also increased with age and with blood pressure, and hypertensive retinopathy was particularly found in cats with systolic blood pressures > 168 mm Hg. There was an increased risk for hypertensive retinopathy in cats that were female, > 10 years old, and neutered. The risk of chronic renal failure also increased as blood pressure, particularly systolic blood pressure, increased. CONCLUSIONS AND CLINICAL RELEVANCE: Hypertensive retinopathy was common in cats > or = 10 years of age and was associated with systolic blood pressures > 168 mm Hg when measured by the noninvasive oscillometric technique.  相似文献   

8.
OBJECTIVES: To determine the effect of the route and rate of protamine administration on the amount of protamine that could be delivered before a hemodynamic reaction occurred in dogs. STUDY DESIGN: Prospective randomized experimental study. ANIMALS: Twenty adult mixed-breed dogs weighing 25.1+/-2.5 kg. METHODS: Before vascular surgery, the dogs were heparinized to reach an activated clotting time (ACT) of 300 seconds. After completion of the vascular surgery, protamine was administered intravenously until a hemodynamic reaction was recorded. The 4 groups of dogs were given protamine at 5 mg/min (slow) or 10 mg/min (fast) via the cephalic or the jugular veins. Systemic and pulmonary arterial pressures, central venous pressure (CVP), and pulmonary arterial occlusion pressure (PAOP) were recorded before and after protamine administration. The dose of protamine was recorded when a reaction occurred, which was defined as mean arterial pressure (MAP) <60 mm Hg or mean pulmonary arterial pressure (MPAP) >20 mm Hg or more than double the baseline value. RESULTS: Significant decreases in systolic arterial pressure (SAP), MAP, and diastolic arterial pressure (DAP) and significant increases in systolic (SPAP), mean (MPAP), and diastolic (DPAP) pulmonary arterial pressures were recorded after protamine administration. The cephalic slow group had significantly fewer protamine reactions than other groups (chi-square = 8.57, P = .03, df = 3). Significantly more protamine could be delivered from the cephalic vein (52.5+/-14.5 mg) compared with the jugular vein (37.6+/-16 mg) before a reaction occurred (P = .048). CONCLUSION: The rate of administration did not have an effect on the amount of protamine delivered. Adverse reactions were minimized when protamine was administered via the cephalic vein at a slow rate. CLINICAL RELEVANCE: We would recommend delivering protamine after cardiopulmonary bypass or vascular surgery through a peripheral venous route.  相似文献   

9.
Proteinuria, and renal tubular casts and epithelial cells in urine sediment, are commonly observed in both complicated and uncomplicated babesiosis, but do not necessarily reflect or predict renal failure. This study investigated the presence and degree of renal damage in canine babesiosis. Renal function and integrity were evaluated using serum urea and creatinine, serum electrolytes (sodium and potassium), fractional clearance of sodium (FcNa) and potassium (FcK), urine enzyme activity of gamma-glutamyl transpeptidase and alkaline phosphatase, urine protein:creatinine ratio, and urinalysis. One control group (n = 10) and 3 groups of babesiosis cases were studied: mild uncomplicated (n = 10), severe uncomplicated (n = 11), and complicated (n = 9). All babesiosis groups showed well-concentrated urine. Mean serum urea was elevated in the severe and complicated groups, and was significantly different from the control group. There was no statistically significant difference between the groups for creatinine, although the complicated group had a mean value above the normal reference range. Hypokalaemia was uncommon in all the groups. Hyperkalaemia was present in only 2 dogs in the complicated group. Marginal hyponatraemia was present in a minority of dogs in all groups. The serum electrolytes were not significantly different between groups. There was no overall elevation, nor any statistically significant difference in both the FcNa and FcK between the groups. Only 1 dog, in the complicated group, showed marked enzymuria. Proteinuria was a common finding and was significantly different between the severe and complicated groups and the control group. Some dogs in all groups had renal tubular epithelial cells in the urinary sediment, which increased in severity from the mild to the complicated groups and was significantly different from the control group. This study demonstrated that minimal renal damage occurs more often in canine babesiosis than significant damage or acute renal failure.  相似文献   

10.
Canine babesiosis is a tick‐borne disease with a worldwide distribution that can involve multiple organs and result in a wide variety of clinical manifestations. Our goal was to describe the sonographic changes occurring in 72 dogs naturally infected with babesiosis. Seven healthy Beagle dogs were used as a control group. The most common finding in all dogs was splenomegaly with a diffuse heterogenic parenchyma and generally reduced echogenicity. Diffuse hypoechoic hepatomegaly and bilaterally increased cortical echogenicity of the renal parenchyma were found more frequently in severe uncomplicated and complicated babesiosis groups. Mean renal resistive index and pulsatility index (PI) values were 0.66/1.35, 0.73/1.91, and 0.71/1.73 for mild uncomplicated, severe uncomplicated, and complicated babesiosis groups, respectively. A markedly increased PI for complicated and severe uncomplicated groups correlated with anemia and severity of renal damage. Ultrasonography can be an adjunct for diagnosis and monitoring canine babesiosis and its systemic complications. The detection of diffuse heterogeneous splenomegaly can support the diagnosis of Babesia infection, because of the high prevalence of this lesion in these patients.  相似文献   

11.
Hypertension in Cats With Chronic Renal Failure or Hyperthyroidism   总被引:6,自引:0,他引:6  
The Doppler ultrasonic recording technique was used to measure systolic and diastolic blood pressures indirectly in 28 cats with naturally occurring renal failure, 39 cats with hyperthyroidism, and 33 clinically normal cats. The mean systolic and diastolic blood pressures in the normal cats were 118.4 +/- 10.6 mm Hg and 83.8 +/- 12.2 mm Hg, respectively. In the cats with chronic renal failure, both the systolic (146.6 +/- 25.4 mm Hg) and diastolic (96.6 +/- 15.2 mm Hg) blood pressures were significantly higher (P less than 0.0001 and P less than 0.01, respectively) than in the normal cats. Elevations in systolic and/or diastolic blood pressure were recorded in 17 (61%) of the 28 cats with chronic renal failure. In the 39 untreated hyperthyroid cats, both the mean systolic (167.9 +/- 28.9 mm Hg) and diastolic (111.6 +/- 21.5 mm Hg) pressures also were significantly higher (P less than 0.0001) than normal. Increased systolic and/or diastolic blood pressure was recorded in 34 (87%) of the 39 hyperthyroid cats. In seven cats with hyperthyroidism that were reevaluated two to four months after successful treatment of the hyperthyroid state, there was a significant fall in mean systolic pressure (P less than 0.05) from a pretreatment value of 159.5 +/- 15.4 mm Hg to a posttreatment value of 132.0 +/- 1.62 mm Hg. Overall, the results of this study indicate that mild to moderate hypertension is common in cats with chronic renal failure and in cats with untreated hyperthyroidism. In addition, the hypertension appears to be reversible following successful treatment of the hyperthyroid state.  相似文献   

12.
Mitral valve regurgitation was created in 2 groups of dogs. Groups were selected on absence (group 1) or presence (group 2) of clinical signs of congestive left ventricular failure. Group-2 dogs, in which mean left atrial pressures were greater than 30 mm of Hg, had increases in heart rate, pulmonary arterial mean pressure, left atrial diameter, and left ventricular diastolic diameter. These changes were associated with decreased arterial O2 tension, decreased static and dynamic compliance, reduced lung volumes, and increased pulmonary resistance. Group-1 dogs, in which mean left atrial pressure was less than 30 mm of Hg, had moderate changes in hemodynamics, but no changes in pulmonary function, except during exercise when arterial O2 tension decreased.  相似文献   

13.
Babesiosis, caused by the virulent haemoprotozoan parasite Babesia canis rossi, is an important disease of dogs in South Africa. The nitric oxide metabolites, nitrate and nitrite (collectively termed reactive nitrogen intermediates or RNIs) were measured in admission sera from dogs in a babesiosis-endemic area. Five groups were prospectively studied: mild uncomplicated (n=9), severe uncomplicated (severe anaemia) (n=10) and complicated babesiosis (n=11); and two groups of healthy aparasitaemic dogs: endemic controls from the study area (n=10) and experimental dogs kept in tick-free conditions (n=10). Four measures of RNI production were studied: (i) serum RNI; (ii) serum RNI/creatinine ratio; (iii) fractional clearance of RNI (FC(RNI)); (iv) fractional excretion of RNI (FE(RNI)). Marked elevations of serum RNI occurred in only two dogs, both in the severe uncomplicated group. The highest concentration (log value 5.29 micromol/l) was in a dog that died, but concentrations in the other four dogs that died were unremarkable (0, 0.34, 1.66 and 2.64 micromol/l). Age, appetite and free serum haemoglobin were significant covariates for measures of RNI production. There were no significant differences among the babesiosis groups for serum RNI. Adjustment for creatinine had minor effects on the results. All babesiosis groups had significantly higher serum RNI and RNI/creatinine than the tick-free control group, but did not differ from the endemic controls except for the severe uncomplicated group, which had higher RNI/creatinine. The complicated group had significantly lower FC(RNI) and FE(RNI) than all other groups, except for the tick-free control group, which had similar FE(RNI). The results indicate that, in an endemic area, measures of RNI production are unlikely to be useful indicators of severity or outcome in canine babesiosis.  相似文献   

14.
The effects of sevoflurane on anesthesia induction, recovery, ventricular pressures, heart rate, ventricular pH, blood gas values, and electrolytes were evaluated in desert tortoises (Gopherus agassizii). Tortoises were orotracheally intubated while awake and ventilated manually with 3-7% sevoflurane in oxygen (1 L/min) to achieve desired expired sevoflurane concentrations. Data, consisting of induction time, recovery time, systolic, diastolic, and mean ventricular pressures, heart rate, ventricular pH, blood gas values, and electrolytes, were collected prior to anesthesia and sequentially at 2.50% and 3.75% expired sevoflurane as measured at the junction of the endotracheal tube and the breathing circuit. Blood pressure was measured and blood samples were collected through a 25-ga needle passed through a cardiac access port that was placed while the tortoises were in dorsal recumbency. Mean (+/-SE) induction time was 2.55+/-0.55 min, recovery time was 27.58+/-7.55 min, and duration of anesthesia was 105+/-12 min. Mean (+/-SD) values for systolic, diastolic, and mean ventricular pressures in awake tortoises were 28+/-3 mm Hg, 22+/-2 mm Hg, and 24+/-2 mm Hg, respectively. Sevoflurane (2.5% expired) significantly decreased systolic (14+/-3 mm Hg), diastolic (12+/-1 mm Hg), and mean (13+/-1 mm Hg) ventricular pressures compared with those of awake tortoises. Ventricular pressures did not decrease further with increasing depth of anesthesia. Heart rate (32+/-4 beats/min) did not change significantly under sevoflurane anesthesia. Sevoflurane administration increased ventricular PO2 but did not change Na+, K+, or iCa++ concentrations. Sevoflurane appears to provide safe and effective anesthesia with rapid induction and recovery.  相似文献   

15.
The cardiopulmonary effects of different levels of carbon dioxide insufflation (3, 5 and 2 mm Hg) under two-lung ventilation were studied in six sevoflurane (1.5 minimum alveolar concentration; MAC) anaesthetized dogs during left-sided thoracoscopy. An arterial catheter, Swan-Ganz catheter and multianaesthetic gas analyser were used to monitor the cardiopulmonary parameters during the experiment. Baseline data were obtained before intrathoracic pressure elevation and the measurements were repeated at intervals after left lung collapse induced by insufflation with carbon dioxide gas. The intrapleural pressure levels used were 3, 5 and 2 mm Hg. Arterial blood pressures, cardiac index, stroke index, left and right ventricular stroke work index, arterial haemoglobin saturation, arterial oxygen tension and systemic vascular resistance decreased significantly during hemithorax insufflation, whereas heart rate, right atrial pressure, mean, systolic and diastolic pulmonary arterial pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance and arterial carbon dioxide tension significantly increased during intrapleural pressure elevation. Although carbon dioxide insufflation into the left hemithorax with an intrapleural pressure of 2-5 mm Hg compromises cardiac functioning in 1.5 MAC sevoflurane anaesthetized dogs, it can be an efficacious adjunct for thoracoscopic procedures. Intrathoracic view was satisfactory with an intrapleural pressure of 2 mm Hg. Therefore, the intrathoracic pressure rise during thoracoscopy with two-lung ventilation should be kept as low as possible. Additional insufflation periods should be avoided, since a more rapid and more severe cardiopulmonary depression can occur.  相似文献   

16.
Intramedullary pressure in canine long bones   总被引:1,自引:0,他引:1  
Intramedullary pressure was measured bilaterally in 36 dogs: in the diaphysis and distal metaphysis of the femur, in the proximal metaphysis of the tibia and humerus, and in the diaphysis of the radius. Pressure measurements were repeated in 5 dogs, 14 days after the initial recordings. Mean (+/- SD) pressures in the femoral diaphysis and distal metaphysis were 27.6 (+/- 15.4) mm of Hg and 17.6 (+/- 10.5) mm of Hg, respectively. Mean (+/- SD) pressures in the tibial diaphysis and proximal metaphysis were 26.4 (+/- 13.0) mm of Hg and 17.9 (+/- 11.8) mm of Hg, respectively. Mean (+/- SD) pressures in the humeral diaphysis and proximal metaphysis were 26.2 (+/- 15.8) mm of Hg and 13.4 (+/- 7.7) mm of Hg, respectively. The mean (+/- SD) pressure in the radial diaphysis was 15.4 (+/- 18.9) mm of Hg. Metaphyseal pressure was significantly (P less than 0.05) lower than diaphyseal pressure. Repeated pressure measurements in 5 dogs did not vary significantly from initial values, suggesting that the wide range of pressure was real not artifactual.  相似文献   

17.
OBJECTIVES: To obtain reference arterial blood pressure values from Kangal dogs, a local giant breed found in Turkey. METHODS: Arterial blood pressure measurements were obtained from 48 healthy Kangal dogs using oscillometric and Doppler techniques. The ages of the dogs ranged from two to 96 months, with a mean (sd) age of 36 (16) months. RESULTS: The effect of age on systolic, diastolic and mean arterial pressures determined by the oscillometric technique and on systolic pressure determined by the Doppler technique was significant (P<0.001). Blood pressure was found to be higher in mature dogs compared with that in immature dogs. The effect of sex and the interaction between age and sex were not significant (P>0.05). There was a direct relationship between age and oscillometric systolic, diastolic and mean arterial pressures and Doppler systolic arterial blood pressure both in the whole group and the immature group (P<0.05). Correlation between age and systolic arterial blood pressure measured either by oscillometric or Doppler techniques was not significant in the mature group. CLINICAL SIGNIFICANCE: The Kangal dog is bred in various countries including Turkey. It is known that giant breed dogs, such as the Kangal dog, are predisposed to cardiovascular disease. Canine arterial blood pressure values are highly breed and age dependent, so a reference value for any other breed is inappropriate for Kangal dogs. Therefore, it is important to measure arterial blood pressure of Kangal dogs.  相似文献   

18.
This study compared the sensitivity of ECG and cardiac troponins to predict cardiac histopathological changes, clinical severity, and survival in canine babesiosis. One control group (n = 9) and 4 groups of dogs with mild uncomplicated babesiosis (n = 8), severe uncomplicated babesiosis (n = 9), complicated babesiosis (n = 8), and babesiosis and concurrent immune-mediated hemolytic anemia (IMHA) (n = 9) were studied. A 1-minute lead II ECG was recorded, and cardiac troponin I (cTnI) and T (cTnT) concentrations in plasma were measured. cTnI concentrations were significantly higher in the complicated (mean, 9.9; SE, +/-5.76) and concurrent IMHA (mean, 6.53; SE, +/-4.32) groups and in the 3 dogs that died of the disease (mean, 22.17; SE, +/-12.85) than in the control dogs (concentration below detection limit of test, -0.3 ng/mL). The 3 nonsurvivors had the most severe cardiac histopathological changes, but no arrhythmia and minimal other ECG changes. Dogs with babesiosis developed a variety of ECG abnormalities, but the abnormalities were not associated with disease severity, outcome, or plasma cardiac troponin concentrations. The exception was the presence of ventricular premature complexes (VPCs), which were associated with high cardiac troponin concentrations. This study showed an association between cTnI concentration and histological changes, clinical severity, and survival and no correlation between ECG abnormalities and histological changes or biochemical evidence of myocardial damage as reflected by cTnI concentrations. From this study, it was concluded that the analysis of plasma cTnI is a feasible and sensitive test and is superior to cTnT in diagnosing cardiac involvement in dogs with babesiosis.  相似文献   

19.
In a series of 3 studies, indirect blood pressure measurements were obtained to define normal variance, identify hypertension, and estimate the prevalence of hypertension in apparently healthy dogs. In part 1, we measured values in 5 clinically normal dogs twice weekly for 5 weeks in a home setting. Mean +/- SD systolic arterial pressure (SAP) and diastolic arterial pressure (DAP) was 150 +/- 16 and 86 +/- 13 mm of Hg, respectively. The DAP significantly (P less than 0.01) decreased with repeated measurements over the 5-week period. In part 2, we assessed the variation between blood pressures measured in a clinic vs those measured in the home. Within a 2-week period, measurements were obtained from 10 clinically normal dogs in a private veterinary clinic and again in their home. Significant differences were not observed between clinic and home measurements of SAP and DAP; however, heart rate was significantly (P less than 0.05) higher in the clinic. In part 3, SD about the SAP and DAP mean values were determined in 102 clinically normal dogs. Canine hypertensive status was determined, using statistical methods and data from 102 clinically normal dogs. Values of SAP greater than 202 mm of Hg and DAP greater than 116 mm of Hg were determined to be 2 SD beyond the mean and, therefore, were interpreted to be hypertensive. Approximately 10% of the 102 apparently healthy dogs measured in this study were considered hypertensive on the basis of these criteria. In addition, a border zone of suspected hypertension was estimated, using the mean + 1.282 SD. The SAP border zone was between 183 and 202 mm of Hg, whereas the DAP border zone was between 102 and 113 mm of Hg. Of the 102 dogs, 12 had values within these zones of suspected hypertension.  相似文献   

20.
Objective – To determine the accuracy and precision of an oscillometric noninvasive blood pressure device as a predictor of invasive direct blood pressure in healthy anesthetized hypotensive and normotensive dogs. Design – Prospective observational study. Setting – University teaching hospital. Animals – Eight crossbred adult dogs. Interventions – Anesthesia was induced with propofol and maintained with isoflurane. A catheter was placed in the dorsal pedal artery to record systolic, mean, and diastolic arterial blood pressures (aSAP, aMAP, and aDAP, respectively). The noninvasive blood pressure device cuff was placed around the contralateral front limb to record noninvasive systolic, mean, and diastolic blood pressure (nSAP, nMAP, and nDAP). Two states of blood pressure (BP) were studied: baseline state was established by keeping end‐tidal isoflurane concentration at 1.2±0.1%. The hypotensive state was achieved by maintaining the same isoflurane concentration while withdrawing approximately 40% of the animal's blood volume until aMAP was stable at approximately 40 mm Hg. At the end of the study, blood was returned to the animal and it was allowed to recover from anesthesia. Measurements and Main Results – Agreement between the direct and indirect BP measurements was determined by the Bland‐Altman method. The SAP and MAP but not DAP bias varied significantly between each BP state. Normotensive absolute biases (mean [SD]) for SAP, MAP, and DAP were ?14.7 mm Hg (15.5 mm Hg), ?16.4 mm Hg (12.1 mm Hg), and ?14.1 mm Hg (15.8 mm Hg), respectively. Absolute biases during the hypotensive state for SAP, MAP, and DAP were ?32 mm Hg (22.6 mm Hg), ?24.2 mm Hg (19.5 mm Hg), and ?16.8 mm Hg (17.2 mm Hg), respectively. Conclusion – The oscillometric device was not reliably predictive of intra‐arterial BP during hypotension associated with acute hemorrhage.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号