首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The in vitro biomechanical properties of three methods for internal fixation of femoral neck fractures were evaluated. Fifty cadaveric femura from Beagle dogs were used. Ten intact femora served as controls. In 40 femura, an osteotomy of the femoral neck was performed to simulate a transverse fracture. With the remaining 30 femura, three repair methods (two medium Orthofix pins, a 2.7 mm cortical bone screw placed in lag fashion and an anti- rotational Kirschner wire, or three divergent 1.1 mm Kirschner wires) were used to stabilize the osteotomies, and 10 osteotomies were stabilised per repair method. These 30 femura where then subject to monotonic loading to failure. Construct stiffness and load to failure were measured. In the remaining 10 femura, pressure sensitive film was placed at the osteotomy site prior to stabilization with either two Orthofix pins (n = 5) or a screw placed in lag fashion (n = 5) to determine the compressive pressure (MPa), compressive force (KN) and area of compression (cm2). There was no significant difference in the stiffness or load to failure for the three repair methods evaluated. There was no significant difference in the compressive pressure, compressive force or area of compression in osteotomies stabilized with Orthofix pins and 2.7 mm bone screws.  相似文献   

2.
OBJECTIVE: To evaluate 2 methods of midbody proximal sesamoid bone repair--fixation by a screw placed in lag fashion and circumferential wire fixation--by comparing yield load and the adjacent soft-tissue strain during monotonic loading. STUDY DESIGN: Experimental study. SAMPLE POPULATION: 10 paired equine cadaver forelimbs from race-trained horses. METHODS: A transverse midbody osteotomy of the medial proximal sesamoid bone (PSB) was created. The osteotomy was repaired with a 4.5-mm cortex bone screw placed in lag fashion or a 1.25-mm circumferential wire. The limbs were instrumented with differential variable reluctance transducers placed in the suspensory apparatus and distal sesamoidean ligaments. The limbs were tested in axial compression in a single cycle until failure. RESULTS: The cortex bone screw repairs had a mean yield load of 2,908.2 N; 1 limb did not fail when tested to 5,000 N. All circumferential wire repairs failed with a mean yield load of 3,406.3 N. There was no statistical difference in mean yield load between the 2 repair methods. The maximum strain generated in the soft tissues attached to the proximal sesamoid bones was not significantly different between repair groups. CONCLUSIONS: All repaired limbs were able to withstand loads equal to those reportedly applied to the suspensory apparatus in vivo during walking. CLINICAL RELEVANCE: Each repair technique should have adequate yield strength for repair of midbody fractures of the PSB immediately after surgery.  相似文献   

3.
4.
5.
6.
The case histories of three young thoroughbred racehorses with displaced lateral condylar fractures combined with an axial fracture of the lateral sesamoid bone are described. In two cases the condylar fracture was repaired surgically but both horses developed severe degenerative joint disease and remained lame. The third horse was destroyed humanely. It is important that axial fractures of the sesamoid bone are recognised so that a poorer prognosis can be given for treatment of condylar fractures in racing thoroughbreds.  相似文献   

7.
An 11-month-old cat was referred following a road traffic accident with non-weightbearing forelimb lameness and tachypnoea. A diaphragmatic rupture was repaired two days after trauma. Six days post trauma, a further operation was performed to repair the fractured humerus. As an intramedullary pin was advanced into the bone to achieve stabilisation, acute respiratory arrest occurred. Manual extrathoracic cardiopulmonary resuscitation was immediately instigated, but the cat did not recover. Postmortem examination identified a high degree of embolic fat occluding pulmonary capillaries. A massive embolic shower was established as the cause of death.  相似文献   

8.
9.
Three horses and three ponies were treated for traumatic luxation of the proximal intertarsal or tarsometatarsal joint. In each case, there were fractures of one or more tarsal bones. Three of the animals had disruption of one of the collateral ligaments. Five animals were treated by closed reduction and external coaptation. One pony was treated by open curettage, a cancellous bone graft, and cast immobilization. No internal fixation was used in any of these animals. From this series of cases, it would appear that closed reduction and external coaption alone is adequate treatment for most cases of tarsal luxation.  相似文献   

10.
11.
OBJECTIVE: To quantitatively compare 3 commonly used treatments for navicular syndrome (NS) in horses: heel-elevation shoeing alone, heel-elevation shoeing and phenylbutazone administration, heel-elevation shoeing and injection of the distal interphalangeal joint (DIPJ) with triamcinolone acetonide (TA), and all 3 treatments in combination. ANIMALS: 12 horses with NS. PROCEDURE: A force plate was used to measure baseline peak vertical ground reaction force (PVGRF) of the forelimbs. Each horse's forelimbs were shod with 3 degrees heel-elevation horseshoes; PVGRF was measured 24 hours and 14 days after shoeing. Fourteen days after shoeing (following data collection), phenylbutazone (4.4 mg/kg, i.v., q 12 h) was administered (5 treatments). Two hours after the fifth treatment, PVGRF was measured; TA (6 mg) was injected into the DIPJ of the forelimb that generated the lower baseline PVGRF Fourteen days later, PVGRF was measured. Phenylbutazone was administered as before, and PVGRF was measured. Percentage body weight of force (%BWF) was calculated from PVGRF measurements and used for comparisons. RESULTS: 14 days after shoeing, mean %BWF in both forelimbs significantly increased from baseline; additional administration of phenylbutazone significantly increased %BWF applied from the more lame forelimb. Compared with shoeing alone, there was no significant change in %BWF after injection of the DIPJ with TA in shod horses. CONCLUSIONS AND CLINICAL RELEVANCE: Heel-elevation shoeing alone and in combination with phenylbutazone administration quantitatively decreased lameness in horses with NS. Although not significant, additional DIPJ injection with TA resulted in further quantitative decrease in lameness, compared with that achieved via shoeing alone.  相似文献   

12.
OBJECTIVE: To compare the biomechanical properties of intact immature horse femurs and 3 stabilization methods in ostectomized femurs. Animal or SAMPLE POPULATION: Eighteen pairs of femurs from immature horses aged 1 to 15 months, and weighing 68 to 236 kg. METHODS: Thirty-four immature horse femurs were randomly assigned to 1 of 5 test groups: 1) interlocking intramedullary nail (IIN) (n = 6); 2) IIN with a cranial dynamic compression plate (I/DCP) (n = 6); 3) 2 dynamic compression plates (2DCP) (n = 8); 4) intact femurs tested to failure in lateromedial (LM) bending (n = 6); and 5) intact femurs tested to failure in caudocranial (CaCr) bending (n = 8). Mid-diaphyseal ostectomies (1 cm) were performed in all fixation constructs. Biomechanical testing consisted of 4 nondestructive tests: CaCr bending, LM bending, compression, and torsion, followed by bending to failure. All groups were tested to failure in LM bending with the exception of 1 group of intact femurs tested to failure in CaCr bending. Stiffness and failure properties were compared among groups. RESULTS: The 2DCP-femur construct had greater structural stiffness in nondestructive bending than the IIN-femur construct in either LM or CaCr bending, and the I/DCP-femur construct in LM bending. Only the I/DCP and 2DCP fixations were similar to intact bone in nondestructive-bending tests. In addition, the 2DCP-femur construct had greater structural and gap torsional stiffness than the I/DCP-femur construct, and greater gap torsional stiffness than the IIN-femur construct. However, all of the fixation methods tested, including the 2DCP-femur construct, had lower structural stiffness in torsional loading compared with intact bone. No significant differences in structural stiffness were found between intact bones and femur constructs tested nondestructively in compression. In resistance to LM bending to failure, the 2DCP-femur construct was superior to the IIN-femur construct, yet similar to the I/DCP-femur construct. Also, evaluation of yield and failure loads revealed no significant differences between intact bone and any of the femur constructs tested to failure in LM bending. CONCLUSIONS: In general, the 2DCP-femur construct provided superior strength and stiffness compared with the IIN and I/DCP-femur constructs under bending and torsion. CLINICAL RELEVANCE: Double plating of diaphyseal comminuted femoral fractures in immature horses may be the best method of repair, because in general, it provides the greatest strength and stiffness in bending and torsion.  相似文献   

13.
14.
OBJECTIVE: To compare monotonic mechanical properties of gap-ostectomized third metacarpal bones (MC3) stabilized with an MP35N interlocking nail system with contralateral intact bones. ANIMALS OR SAMPLE POPULATION: Twenty-four pairs of cadaveric equine MC3s. METHODS: Third metacarpal bones were divided into 4 mechanical testing groups (6 pairs per group): compression, palmarodorsal (PD) and mediolateral (ML) 4-point bending, and torsion. One MC3 from each pair was randomly selected as an intact specimen, and the contralateral gap ostectomized bone was stabilized with a 4-hole, 14-mm-diameter, 250-mm-long, MP35N intramedullary nail, and four, 7-mm-diameter, 60-mm-long MP35N interlocking screws (constructs). Mechanical testing properties were compared between intact specimens and constructs with a paired t test (significance set at P <.05). RESULTS: Intact specimens were significantly stronger and stiffer than constructs in all testing modes except PD bending. Constructs achieved mean yield strengths that were 57% (compression), 81% (PD bending), 68% (ML bending), and 78% (torque) of intact specimens. Constructs achieved mean stiffnesses that were 53% (compression), 58% (PD bending), 41% (ML bending), and 47% (torque) of intact specimens. CONCLUSION: Monotonic yield mechanical properties of MP35N intramedullary interlocking nail-stabilized, gap-ostectomized MC3 were lower than those of paired intact bones but exceeded reported in vivo loads for dorsopalmar bending and compression and estimated in vivo torsional loads. CLINICAL RELEVANCE: Considering the benefits associated with intramedullary interlocking nail fixation of fractures, this system should be considered for use for repair of MC3 fractures with applicable fracture configurations.  相似文献   

15.
OBJECTIVE: To quantify total fluid loss in sweat of Thoroughbreds during >3 hours of low-intensity exercise in controlled conditions and to calculate and compare estimated ion losses in sweat, according to 3 methods. ANIMALS: 6 exercise-trained Thoroughbreds. PROCEDURE: Fluid and ion losses in sweat were measured in 6 horses exercising at 40% of the speed that elicited maximum oxygen consumption for 45 km. Horses were given a 15-minute rest period at the end of three 15-km exercise phases. Horses completed 2 exercise trials. Ion losses in sweat were calculated, using measurements of local sweating rate and sweat ion composition (SWT), change in net exchangeable cation content (CAT), and change in extracellular ion content (PLAS) derived from plasma total solids and ion concentrations. RESULTS: Measurement of SWT revealed a mean (+/- SEM) fluid loss in sweat during 45 km of exercise of 27.5 +/- 1.6 L. Total ion loss in sweat was approximately 241 g or 7.8 mol with higher sodium losses in the second and third phases of exercise compared with the first phase. Losses of sodium and potassium calculated by SWT or CAT were not significantly different from each other, whereas losses of these ions as determined by PLAS were significantly lower. CONCLUSIONS AND CLINICAL RELEVANCE: Calculation of ion losses from a mean whole body sweating rate extrapolated from either local sweating rate and sweat ion composition or from change in net exchangeable cation content provide similar results, whereas ion losses determined by changes in extracellular ion content derived from plasma total solids and ion concentration results in underestimation of actual losses.  相似文献   

16.
Repair of a Salter-Harris type IV dicondylar humeral fracture was performed on a 15-week-old pitbull terrier. Interfragmentary compression of the intracondylar component of the fracture was achieved with a transilial rod and locking nuts (Trans-ilial Rod; IMEX Veterinary, Inc.). The transilial rod was articulated with a modified type I external fixator which functioned as adjunctive stabilisation for the supracondylar component of the fracture. Fracture healing was confirmed radiographically five weeks following surgery. The dog had no appreciable lameness when examined 12 months after fracture repair.  相似文献   

17.
18.
19.
Three feeding methods were compared in 36 4- to 6-year-old Franche-Montagne horses during the military school of St-Luzisteig (GR) of Spring 1992. The horses were separated into 3 groups: a group with the traditional oats-hay ration (OH), a group with a pelleted feed and hay ration (PFH), and a group with the complete diet (CD). Feed analyses were performed and food consumption, eating behavior and digestibility were studied. The horses received their daily amount of feed in 3 portions covering the requirements for a medium work: OH = 8 kg hay and 3 kg oats, PFH = 8 kg hay and 3 kg pelleted feed and CD = 10 kg of the complete diet. For the 3 rations, the amount of digestible crude protein for horses was higher than the reference value for the requirement of a 600 kg horse with a medium work. In the 3 diets, the calcium content was higher than the required 32 g per day (g/d). Not enough sodium (OH: 1.2 g/d; PFH: 7.3 g/d; CD: 9.6 g/d) and too much potassium (OH: 140.3 g/d; PFH 153.0 g/d; CD: 167.5 g/d) were present in the diets, both without consequences for the blood parameters. In 3 meals of 60 minutes, the horses of the group OH, PFH and CD ingested 82%, 89% and 92%, respectively, of the daily ration. The complete diet was ingested more quickly than the hay. The number of mastications per minute was smaller for the complete diet than for the hay. Ingestion times were similar for oats and pelleted feed. However, the number of mastications per minute was smaller for the pelleted feed. The digestibility of nutrients was not influenced by the method of feeding. In conclusion, these results demonstrate that the 3 types of ration studied here are adequate for the swiss army horses if sodium is added to the diet. However, despite the fact that both PFH and CD correct excessive supply or deficiencies of nutrients and despite the fact that these two feeding methods offer nutrients in amounts that are closer to the requirements of the horse, the method PFH was introduced in 1994.  相似文献   

20.
Surgical repair of a fractured tibiotarsus in a scarlet macaw (Ara macao) is described. The forces imposed on the fracture site are discussed and the unique features of avian bone emphasised. Advantages of external skeletal fixation and specific details of the frame construction are highlighted.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号