首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
Objective To determine the practicability and accuracy of central corneal thickness (CCT) measurements in living chicks utilizing a noncontact, high‐speed optical low‐coherence reflectometer (OLCR) mounted on a slit lamp. Animals studied Twelve male chicks (Gallus gallus domesticus). Procedures Measurements of CCT were obtained in triplicate in 24 eyes of twelve 1‐day‐old anaesthetized chicks using OLCR. Every single measurement taken by OLCR consisted of the average result of 20 scans obtained within seconds. Additionally, corneal thickness was determined histologically after immersion fixation in Karnovsky’s solution alone (20 eyes) or with a previous injection of the fixative into the anterior chamber before enucleation (4 eyes). Results Central corneal thickness measurements using OLCR in 1‐day‐old living chicks provide a rapid and feasible examination technique. Mean CCT measured with OLCR (189.7 ± 3.34 μm) was significantly lower than histological measurements (242.1 ± 47.27 μm) in eyes with fixation in Karnovsky’s solution (P = 0.0005). In eyes with additional injection of Karnovsky’s fixative into the anterior chamber, mean histologically determined CCT was 195.2 ± 8.25 μm vs. 191.9 ± 8.90 μm with OLCR. A trend for a lower variance was found compared to the eyes that had only been immersion fixed. Conclusion Optical low‐coherence reflectometry is an accurate examination technique to measure in vivo CCT in the eye of newborn chicks. The knowledge of the thickness of the chick cornea and the ability to obtain noninvasive, noncontact measurements of CCT in the living animal may be of interest for research and development of eye diseases in chick models.  相似文献   

2.
Objective To provide normative data for canine whole retinal thickness (WRT), nerve fiber layer thickness (NFL), photoreceptor layer thickness (PR), and outer nuclear layer thickness (ONL) using spectral domain optical coherence tomography. Animal studied: Twelve healthy adult intact female beagles. Procedure Horizontal volume scans through the area dorso‐temporal from the optic nerve (superior retina), and the area ventro‐temporal from the optic nerve (inferior retina) were used to evaluate the thickness of retinal NFL, PR, ONL, and WRT. Peripapillary circular scans were used to evaluate NFL thickness. Statistical analyses were performed to compare the thickness of the individual layers between the superior and inferior retina (paired t‐test). One‐way analysis of variance (ANOVA) was used to compare the thickness of peripapillary NFL between the superior, inferior, temporal and nasal quadrants of the circle scan. Results The WRT, PR, and NFL thickness were greater in the superior than in the inferior retina (198.7 ± 9.6 μm vs. 164.4 ± 6.4 μm, P < 0.0001; 95.5 ± 6.5 μm vs. 78.8 ± 7.4 μm, P < 0.0001; and 26.4 ± 1.6 μm vs. 25.0 ± 1.9 μm, P = 0.0236, respectively). No statistical difference was found between the ONL thickness of the superior and inferior retina (50.1 ± 6.4 μm vs. 44.3 ± 3.6, P = 0.0578). Peripapillary NFL thickness showed a similar tendency as the linear scans, with the superior quadrant having the greatest thickness (91.26 ± 7.0 μm) and the inferior quadrant being the thinnest (76.42 ± 9.2 μm) (P < 0.001). Conclusions Results of our in vivo studies showed significant differences between thickness values for the superior (tapetal) and inferior (nontapetal) retinal regions.  相似文献   

3.
Corneal esthesiometry in the healthy horse   总被引:1,自引:1,他引:0  
Objective To determine corneal sensitivity in healthy adult horses in order to establish reference values. Animals studied One hundred eyes of 50 healthy adult horses. Procedure Corneal sensitivity was determined by evaluating the corneal touch threshold (CTT) in five different corneal regions using a Cochet‐Bonnet esthesiometer. Results Comparing CTT values (in mm filament length) of the five prescribed corneal regions revealed regional variations in corneal sensitivity, with the central region (21.15 ± 6.23 mm) being the most sensitive, followed by the nasal (20.75 ± 5.14 mm), temporal (20.70 ± 5.37 mm), ventral (20.15 ± 5.88 mm) and dorsal (15.85 ± 3.70 mm) region. However, differences between the central, nasal, temporal and ventral regions were not statistically significant, whereas the dorsal region was significantly (P < 0.0001) less sensitive compared to the other regions. Division of the horses into three age groups revealed an insignificant decrease in corneal sensitivity with age in the nasal, temporal, ventral and central region, and an insignificant increase with age in the dorsal region. Correlation of corneal sensitivity with age was statistically significant in the central, ventral and temporal region. No statistically significant difference in the CTT was found between left and right eyes and between males and females. Conclusions CTT values in 100 eyes of 50 healthy adult horses evaluated with a Cochet‐Bonnet esthesiometer generated reference values. Reference values are necessary to determine alterations of corneal sensation accompanying various eye diseases or systemic diseases.  相似文献   

4.
Objective To determine corneal sensitivity in 20 healthy adult alpacas (40 eyes) in order to establish reference values. Design Prospective study. Animals Twenty healthy, adult alpacas. Procedures Corneal sensitivity was determined by the corneal touch threshold (CTT) using a Cochet‐Bonnet esthesiometer. Five different regions of the cornea were evaluated (nasal, ventral, lateral, dorsal, and central). Results Corneal touch threshold values (in mm filament length) obtained from five corneal regions demonstrated varying corneal sensitivities. The central region (34.5 ± 7.1 mm) was the most sensitive, followed by the ventral (29.5 ± 7.2 mm), medial (29.3 ± 7.3 mm), dorsal (25.6 ± 6.3 mm), and lateral (21.8 ± 5.7 mm) regions. All pairwise comparisons of regional differences were statistically significant (P < 0.05), except for the comparison between the ventral and medial regions (P = 0.88). Evaluation of the CCT while controlling for age (2–5 years vs. 6–10 years) demonstrated an increased CTT with an increasing age for the central, ventral, medial and lateral regions. A decrease in the CTT of the dorsal region was noted with increasing age. Conclusion and Clinical Relevance Corneal touch threshold values in 40 eyes of 20 healthy adult alpacas were determined using a Cochet‐Bonnet esthesiometer. This study demonstrated the central corneal region to be most sensitive. Values obtained may serve as reference values in subsequent studies.  相似文献   

5.
Objective To determine the density of the canine and feline corneal neural network in healthy dogs and cats using in vivo confocal microscopy (IVCM). Animals examined A total of 16 adult dogs (9 Mesocephalic breeds, 7 Brachycephalic breeds) and 15 cats (9 Domestic Short-haired cats (DSH), 6 Persian cats) underwent IVCM. Procedure Animals were examined with a confocal corneal microscope (HRTII/RCM; Heidelberg Retina Tomograph II/Rostock Cornea Module®, Heidelberg Engineering, Dossenheim, Germany). The investigations focused on the distribution of the corneal nerves and quantification of central subepithelial and subbasal nerve plexus. Results The corneal stromal nerve trunks, subepithelial and subbasal nerve plexus were observed. The nerve fiber density (NFD) quantified in nerve fiber length in mesocephalic dogs were 12.39 ± 5.25 mm/mm2 in the subepithelial nerve plexus and 14.87 ± 3.08 mm/mm2 in the subbasal nerve plexus. The NFD of the subepithelial nerve plexus in DSH cats was 15.49 ± 2.7 and 18.4 ± 3.84 mm/mm2 in the subbasal nerve plexus. The subbasal NFD of DSH cats was significantly higher than in mesocephalic dogs (P = 0.037). The subepithelial NFD in brachycephalic dogs, and Persian cats were 10.34 ± 4.71 and 9.50 ± 2.3 mm/mm2, respectively. The subbasal NFD measured 11.80 ± 3.73 mm/mm2 in brachycephalic dogs, and 12.28 ± 4.3 mm/mm2 NFD in Persian cats, respectively. The subepithelial and subbasal NFD in Persian cats were significantly lower than in DSH cats (P = 0.028, respectively, P = 0.031), in contrast to brachycephalic vs. mesocephalic dogs. Conclusion The noninvasive IVCM accurately detects corneal innervation and provides a reliable quantification of central corneal nerves.  相似文献   

6.
Purpose To determine axial lens thickness, anterior chamber depth and axial globe length in canine eyes with normal lenses and in eyes with immature, mature, congenital, posterior polar and diabetic cataract. Methods B‐mode ultrasonography was performed in 50 normal dogs and, as a prephacoemulsification screening procedure, in 100 dogs with cataract. Axial B‐mode ultrasonograms were used to determine lens thickness, anterior chamber depth and globe diameter. Statistical comparisons between groups were made by analysis of variance and multivariate analysis, with a significance level of P < 0.05. Results Axial globe lengths were not statistically significantly different between groups apart from the smaller globes in younger dogs with congenital cataract. Axial lens thickness in diabetics (8.4 ± 0.9 mm) was statistically significantly different from the lens thickness in normal eyes (6.7 ± 1.0 mm), eyes with immature cataract (6.4 ± 0.8 mm) and eyes with mature cataract (7.4 ± 0.9 mm) although these groups, while varying in thickness, were not statistically significantly different from each other. Anterior chamber depth was statistically significantly reduced in eyes with diabetic cataract (2.9 ± 0.1 mm) from that in normal eyes (3.8 ± 0.1 mm), eyes with immature cataract (3.5 ± 0.1 mm) and eyes with mature cataract (3.2 ± 0.6 mm) although these groups, while varying in chamber depth, were not statistically significantly different from each other. Conclusions Lenses with diabetic cataracts were significantly increased in axial thickness compared to lenses in other eyes, although lenses with mature cataracts showed a trend towards increased axial thickness and immature cataracts demonstrated a trend towards reduced thickness. While previous studies on cataract pathobiology have suggested a reduction in lens thickness in immature cataract through lens protein loss and an increase in thickness in mature cataracts through intumescence, this study is the first to document these changes in the canine lens.  相似文献   

7.
Purpose These studies examined corneal healing rates, Type‐IV collagen and zonula occludens membrane‐associated protein (ZO‐1) expression, as well as aqueous PGE2 and IL‐1β concentrations in pigmented rabbits treated with either moxifloxacin 0.5%, gatifloxacin 0.3% or BSS® following anterior keratectomy. Methods Anterior keratectomy surgery was followed by topical administration with commercial ophthalmic formulations of either moxifloxacin or gatifloxacin or BSS® (TID for 96 h). Images of the fluorescein‐stained healing corneas were analyzed for wound area. At 48 or 96 h following surgery, aqueous humor samples were collected and analyzed for the inflammatory mediators PGE2 and IL‐1β using an ELISA. The corneas were subsequently evaluated using both scanning and transmission electron microscopy. In a second parallel study, corneas were evaluated at both 48 and 96 h for Type‐IV collagen and ZO‐1 expression using immunohistochemistry. Results Fluorescein‐stained corneal images at 96 h postsurgery demonstrated that 90% ± 8% re‐epithelialization for moxifloxacin, 81% ± 14% for gatifloxacin, and 88 ± 6% for BSS® (P > 0.05). PGE2 levels in the aqueous humor of fluoroquinolone treated eyes were reduced at 48 h compared to BSS® treated eyes. IL‐1β was undetectable in all samples. No differences in Type‐IV collagen or ZO‐1 expression were observed between any treatment groups. There were no differences between groups in histological appearance or in ultrastructural healing processes. Conclusions These studies demonstrated that the commercial ophthalmic formulations of moxifloxacin and gatifloxacin were similar to each other in their effects on the levels of aqueous humor PGE2 and rates of corneal wound re‐epithelialization.  相似文献   

8.
Objective To measure intraocular structures in New Zealand White breed rabbits (Oryctolagus cuniculus Linnaeus, 1758) using A‐mode and B‐mode ultrasound with a 20 MHz transducer. Procedures In this study, the eyes of 15 rabbits were evaluated for determination of intraocular measurements using an ophthalmic ultrasound unit able to operate in both A and B‐modes. The distances from the cornea to the anterior capsule of the lens (D1), from the anterior capsule of the lens to the posterior capsule of the lens (D2), from the posterior capsule of the lens to the retina (D3) and the complete length of the eye, which corresponds to the distance from the cornea to the retina (D4) were taken. Results The mean values obtained were 2.70 mm (±0.22 mm) for D1, 7.32 mm (±0.40 mm) for D2, 7.10 mm (±0.45 mm) for D3 and 17.12 mm (±0.41 mm) for D4. Statistical analyses using the Student’s t‐test showed that there were no differences between the eyes. Conclusions The study was feasible without the need of pharmacological restraint and yielded normal mean values for ocular sonographic biometry in rabbits.  相似文献   

9.
10.

Objective

To characterize the ocular surface parameters and determine the prevalence of ocular pathology in Shih Tzu dogs.

Animal Studied

Fifty Shih Tzu dogs (28 male, 22 female).

Procedures

Each dog underwent a complete ophthalmic examination (recording any pathology) and a series of diagnostics, allowing for a 10 min-interval between tests: intraocular pressure (IOP), blink rate, palpebral fissure length (PFL), corneal tactile sensation (CTS), Schirmer tear test and nasolacrimal reflex without (STT-1, NL-STT1) and with topical anesthesia (STT-2, NL-STT2), tear ferning, strip meniscometry test (SMT), tear film breakup time (TFBUT), and punctate fluorescein staining (PFS) of the cornea.

Results

Mean ± SD test values were as follows: IOP (17.9 ± 3.7 mmHg), blink rate (2.4 ± 1.4 blinks/min), PFL (23.8 ± 1.8 mm), CTS (1.8 ± 0.7 cm), STT-1 (22.0 ± 5.5 mm/min), NL-STT1 (24.2 ± 4.7 mm/min), STT-2 (16.9 ± 6.5 mm/min), NL-STT2 (18.5 ± 7.5 mm/min), SMT (7.5 ± 3.5 mm/5 s), TFBUT (5.3 ± 2.4 s), tear ferning (1.3 ± 0.7), and PFS (1.6 ± 0.6). PFL was significantly greater in male vs. female Shih Tzus (p< .001). Age was negatively correlated with TFBUT results (r = −0.31, p = .027). Lagophthalmos was observed in 82% eyes. Ocular surface pathology was common, including adnexal abnormalities (100% eyes with caruncular trichiasis and medial lower lid entropion) and corneal opacification (27% pigmentation, 20% fibrosis, 12% neovascularization).

Conclusions

Qualitative tear film deficiency (low TFBUT), along with several anatomical abnormalities that promote ocular irritation and reduce globe protection, together help explain the concerningly high prevalence of ocular surface disease in the Shih Tzu breed. Prophylactic measures (e.g., medial canthoplasty, topical lubrication) could be considered to improve ocular health in Shih Tzus.  相似文献   

11.
Objectives To establish normal reference ranges of ocular parameters including phenol read thread, palpebral fissure length, horizontal and vertical corneal diameter, upright and hanging intraocular pressure (IOP) and to report ophthalmic examination findings of the anterior segment and lens, in a population of captive fruit bats. Animals studied Eyes of 30 bats of three species were included in this study: 10 (5 males, 5 females) Malayan Flying Foxes (Pteropus vampyrus), 10 (5 males, 5 females) Little Golden‐mantled Flying Foxes (Pteropus pumilus), and 10 (4 males, 6 females) Island Flying Foxes (Pteropus hypomelanus). Results The most common ophthalmic examination findings included iris‐iris persistent pupillary membranes (83%), nuclear sclerosis (56.7%), prominent arterial circle (40%), iridal hyperpigmented foci (30%), pupillary margin cysts (27%), and third eyelid defects (20%). The mean, among all species for: phenol red thread was 20.23 ± 1.28 mm/15 s both eyes (OU); palpebral fissure length was 13.34 ± 0.33 mm for OU; for horizontal corneal diameter was 10.72 ± 0.32 mm for OU; for vertical corneal diameter was 9.90 ± 0.30 mm for OU; for the hanging intraocular pressures was 19.38 ± 0.77 mmHg for OU; for upright IOP was 13.95 ± 0.60 mmHg for OU. Measurements for the individual species groups and eyes were also calculated. Conclusions Results revealed the IOP of bats in a hanging position were significantly higher than the IOP of bats in an upright position. The size of the bat, between the species, affected palpebral fissure length, horizontal corneal diameter, and vertical corneal diameter. Information about the ocular structures and normal ophthalmic parameters for the Pteropus species is crucial for species protection because of dependence on vision for survival.  相似文献   

12.
Objective To determine reference values for Schirmer tear tests I and II in clinically normal pigs. Animal studied Twenty clinically normal Landrace pigs (10 males and females) without ocular abnormalities were used in this study. Procedures In all pigs, Schirmer tear tests (STT) I and II were performed by using a sterile Schirmer tear test standardized strip (Schirmer‐Tränentest®, Germany) placed in the lower conjunctival fornix for 1 min. Results For each test (STT I and STT II), no differences were observed between the right and left eyes (P ≥ 0.5). The mean ± SD STT I value was 15.6 ± 3.7 mm/min (range, 10–22 mm/min), while the mean STT II value was 12.4 ± 3.8 mm/minute (range, 5–18 mm/min). The mean STT II value was significantly lower than the STT I level (P < 0.001). Animal gender did not have a significant effect on STT I and II values (P = 0.52). The mean ± SD STT I/II values of 10 juvenile pigs were significantly lower than the mean ± SD STT I/II values of 10 adult pigs (P < 0.001). Conclusions This study of 20 Landrace pigs provided valuable information on normal STT I/II in this species. Knowledge of normal STT reference values in pigs enables the clinician to evaluate corneal pathology and diagnose tear deficiency syndromes with greater accuracy.  相似文献   

13.
14.

Objective

To describe normative ocular surface and aqueous tear testing data for cats of various cephalic conformation.

Animals studied

Fifty-three healthy adult cats (11 British Shorthair, 11 Burmese, 10 Devon Rex, 10 Scottish Fold, and 11 Sphynx).

Procedures

Blink rate, corneal tactile sensation (CTS), and Schirmer tear test with or without topical anesthesia (STT-1, STT-2) and with nasolacrimal stimulation (NL-STT1, NL-STT2) were assessed. Palpebral fissure length (PFL) and skull morphology were measured, and cephalic index (CI) and craniofacial ratio (CFR) calculated.

Results

Mean ± SD test results were as follows: blink rate (5.0 ± 2.3 blinks/min), CTS (3.2 ± 0.7 cm), STT-1 (11.2 ± 4.3 mm/min), STT-2 (6.7 ± 3.6 mm/min), NL-STT1 (13.4 ± 5.7 mm/min), NL-STT2 (13.5 ± 5.2 mm/min), and PFL (2.0 ± 0.2 cm). Corneal sensitivity did not differ significantly among breeds (p = .152) but was negatively correlated with body weight (r = −.32, p = .019). STT-1 significantly differed among breeds (p < .001) and was lowest in Sphynx cats (8.7 ± 4.3 mm/min). A positive correlation was detected between STT-1 values at 30 and 60 s (r = .98; p < .001). The nasolacrimal reflex significantly increased STT in anesthetized and unanesthetized eyes (approximately +100% and +20%, respectively; p ≤ .002). STT-1 tended to be higher in intact versus neutered cats (p = .062). Age did not impact any test result (p ≥ .085).

Conclusions

Normative data described here serve as a baseline for future studies assessing ocular surface disease in multiple feline breeds. Unlike dogs, brachycephalic cats did not have lower CTS or STT-1 than non-brachycephalic cats.  相似文献   

15.
Postnatal development of corneal curvature and thickness in the cat   总被引:1,自引:0,他引:1  
Objective To evaluate the postnatal development of central corneal curvature and thickness in the domestic cat. Animals studied Six Domestic Short‐haired (DSH) kittens starting at 9 weeks of age and 6 adult cats. Procedures Kittens were evaluated biweekly to monthly for a 12‐month period, starting at age 9 weeks. Corneal development was monitored by hand‐held keratometry and ultrasound biomicroscopy. Standard regression analysis using a nonlinear least squares method was used to generate a formula that would predict corneal curvature as a function of age. Results Mean keratometry (K) values for the 9‐week‐old cats were 54.51 (±1.02) diopters (D) and these values steeply declined over the next 3 months to 44.95 (±0.90) D. Thereafter, K‐values gradually decreased to reach a plateau by 12–15 months of age of 39.90 (±0.42) D. Because K‐values still appeared to be slightly diminishing at this point, six other > 2‐year‐old cats were evaluated by keratometry and were found to have K‐values of 38.99 (±0.81). Two to four diopters of astigmatism was common in young kittens whereas adult cats had a low mean degree of astigmatism (< 1 D). A formula that predicted keratometry values in diopters (K) as a function of age in weeks (w) was established as follows: K = 39.83 + 26.87 exp(?0.074 w). The central cornea increased in thickness primarily during the first 4 months of life with 9 week‐old kittens having values of 0.379 (±0.012) mm; 16‐week‐old kittens, 0.548 (±0.021) mm and 67 week‐old cats, 0.567 (±0.012) mm. Conclusions The maturation process of the feline cornea proceeds over the first 1–2 years of life to attain an adult status that is characterized by a roughly spherical state of approximately 39 D corneal curvature, substantially flatter than the human cornea, and a central thickness similar to the human cornea. Research studies of the refractive or optical properties of the cornea in which cats are used as experimental animals should be conducted on animals greater than 18 months of age.  相似文献   

16.
Infrared thermography was used to measure temperature differences of the corneal surface between nasal and temporal limbus regions and central cornea of normal dogs and dogs with keratoconjunctivitis sicca (KCS), in order to establish temperature values in normal canine eyes and in patients with decreased Schirmer tear tests (STT) values. Dogs investigated were all either patients seen at the Veterinary Teaching Hospital of Federal University of Paraná or normal dogs that belonged to the same institution. STT were performed in all eyes. A total of 40 control eyes (STT ≥15 mm/min) and 20 eyes with low STT values (STT ≤14 mm/min) were examined. The mean STT value for eyes with normal STT values was 22.9 ± 3.9 mm/min (mean ± standard deviation), and the mean STT value for eyes with low STT value was 7.2 ± 4.8 mm/min. The mean corneal temperature was significantly lower in eyes with low STT values than in control eyes (< 0.0001). The following significant correlations were found: (i) Schirmer and breakup time (BUT) (= 0.0001, = 0.5); (ii) STT values and corneal surface temperature (= 0.001, = 0.256); (iii) STT values and age (= 0.0001, = ?0.448); (iv) age and corneal surface temperature (= 0.0001, = ?0.281); and (v) BUT and corneal surface temperature (= 0.0001, = 0.36). Thermography is a method that can differentiate between eyes with normal and abnormal STT values. In the future, thermography might be incorporated as part of the ophthalmic examination and perhaps become a popular ancillary test for the diagnoses of ocular surface disorders.  相似文献   

17.
Dexmedetomidine is a highly specific and selective α2‐adrenergic receptor agonist widely used in dogs for sedation or analgesia. We hypothesized that dexmedetomidine may cause significant changes in radiographic and echocardiographic measurements. The objective of this prospective cross‐sectional study was to test this hypothesis in a sample of six healthy dogs. Staff‐owned dogs were recruited and received a single dose of dexmedetomidine 250 μg/m2 intravenously. Thoracic radiography and echocardiography were performed 1 h before treatment, and repeated 10 and 30 min after treatment, respectively. One observer recorded cardiac measurements from radiographs and another observer recorded echocardiographic measurements. Vertebral heart score and cardiac size to thorax ratio on the ventrodorsal projection increased from 9.8 ± 0.6 v to 10.3 ± 0.7 v (P = 0.0007) and 0.61 ± 0.04 to 0.68 ± 0.03 (P = 0.0109), respectively. E point‐to‐septal separation and left ventricle internal diameter in diastole and systole increased from 2.4 ± 1.1 to 6.6 ± 1.9 mm, 32.3 ± 8.1 to 35.5 ± 8.8 mm, and 19.4 ± 6 to 27.0 ± 7.2 mm, respectively (P < 0.05). Fractional shortening and sphericity index decreased from 40.7 ± 5.8 to 24.4 ± 2.9%, and 1.81 ± 0.07 to 1.58 ± 0.04, respectively (P < 0.05). Moderate‐to‐severe mitral regurgitation and mild pulmonic regurgitation occurred in all dogs after dexmedetomidine administration. Findings indicated that dexmedetomidine could cause false‐positive diagnoses of valvular regurgitation and cardiomegaly in dogs undergoing thoracic radiography and echocardiography.  相似文献   

18.
19.
Objective To investigate collagen fibrils of the equatorial sclera in relation to the age‐related changes in eye size in sheep. Animals studied Lambs and outbred ewes. Procedures Sheep eyes (three lamb and three from adult outbred ewes), presumed disease‐free, were processed for transmission electron microscopy (TEM) immediately postmortem. Tissue blocks from the equatorial region were sectioned across fibril bundles orientated along the equator. Micrographs including at least 500 fibrils were projected at 22 000× magnification for measures of fibril diameters (FDs). Results Lamb eyes were smaller than those of adult ewes but equatorial scleral thickness was only marginally less at 0.232 ± 0.013 vs. 0.254 ± 0.012 mm (P value not significant). Scleral tissue was composed of compacted bundles of collagen fibers that tended to be rounder in outer compared to being flatter in inner regions. In typical (normal) appearing regions, FDs were distinctly larger (68–410 nm) in outer sclera compared to inner sclera (63–281 nm). Outer sclera FDs were bimodal averaging 192 ± 58 nm, compared to unimodal distributions at inner locations averaging 156 ± 48 nm (P < 0.001). Some atypical regions, especially at outer‐mid sclera locations, were also noted where the FD distribution was bimodal but also included numerous microfibrils (<50 nm diameter), with similar appearances being found for both lamb and adult ewe eyes. Conclusions The equatorial sclera is a mixture of rounder versus flatter collagen fiber bundles, the former being more likely to be made up of a mixture of both smaller and larger fibrils, as compared to slightly smaller fibrils.  相似文献   

20.
Purpose To determine the normal reference range for Schirmer tear test (STT) values in clinically normal llamas (Lama glama) Animals Nine captive llamas (Lama glama) (seven females and two males) were used in this study. Procedure Complete ophthalmic examinations were performed without chemical restraint. STT I values were evaluated in both eyes of all llamas using a commercial STT strip of a single lot number (Schirmer‐Tränentest®, Germany). STT II value was also measured in both eyes of seven female llamas. Results No statistically significant differences among ages or between right and left eyes were found for any of the results. The mean ± SD STT I of 18 eyes of nine llamas was 17.3 ± 1.1 mm/min (Range 15–19 mm/min). The mean ± SD STT II of 14 eyes of seven llamas was 15.4 ± 1.7 mm/min (Range 12.5–17.5 mm/min). A paired samples t‐test demonstrated that there was a significant difference between the STT I and II values (P = 0.001). Conclusion This study provides novel data for normal reference ranges of STT I and II values in healthy llamas. Results of this study may assist veterinarians in the diagnosis of ocular surface disease and syndromes affecting the tear film in these species.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号