首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The vertebral heart size (VHS) is used to objectively assess cardiac dimensions on thoracic radiographs. A high VHS suggest the presence of cardiac pathology, such as dilated cardiomyopathy, degenerative atrioventricular valvular disease, pericardial effusion, pericardioperitoneal diaphragmatic hernia, tricuspid dysplasia, ventricular septal defect, or patent ductus arteriosus, among others. However, breed or body conformation can influence the VHS. Because Greyhounds have a high prevalence of physiologic systolic murmurs associated with high aortic velocity, and large cardiac dimensions when compared with dogs of similar size, they are frequently suspected of having heart disease. The purpose of this study was to compare the VHS in normal Greyhounds with those in Rottweilers, and a group of dogs from various other breeds using both analog and digital radiology. The VHS was significantly higher in Greyhounds (P< 0.0001), when compared with Rottweilers and to other dog breeds. The mean VHS on lateral radiographs for Greyhounds was 10.5 +/- 0.1, for Rottweilers it was 9.8 +/- 0.1, and for mixed breed dogs it was 10.1 +/- 0.2. This study confirms that the relative cardiomegaly reported in necropsy and echocardiographic studies in Greyhounds is easily detected using plain radiography and the VHS.  相似文献   

2.
Thirty-five young cats were studied by echocardiography from the 2nd to 12th weeks of life to analyze correlation between body weight, body surface area, age and heart rate with fourteen echocardiographic parameters. There was a positive linear correlation (r = 0.49-0.78) between the independent variables (body weight, body surface area, age) and left ventricular wall thickness and diameter, aortic diameter and left atrial diameter, whereas there was a negative correlation (r = -0.39 and r = -0.43) between the heart rate and left ventricular diameter during systole and diastole. No linear dependence of the fractional shortening, ejection fraction, percentage thickening of the interventricular septum and left ventricular posterior wall, LA/AO ratio, and the ratio IVSED/LVWED to the independent variables was observed.  相似文献   

3.
ECHOCARDIOGRAPHIC INDICES IN THE NORMAL DOG   总被引:2,自引:0,他引:2  
Twenty young healthy dogs weighing from 9.8 to 28.6 kg were studied by M-mode echocardiography. Parameters were measured and statistically evaluated to determine whether a correlation to body surface area existed. A statistically significant correlation to body size was found for the aortic, left atrial, left ventricular, septal, and posterior wall dimensions and the mitral valve amplitude of motion. In addition, normal values not correlated to body surface area are presented with their means and standard deviations. These values include velocity of circumferential fiber shortening, ejection time, percent systolic thickening of septum and posterior wall, percent change in minor diameter, selected dimension ratios, and mitral valve velocities  相似文献   

4.
Gated radionuclide ventriculography was evaluated as a noninvasive method of quantifying right ventricular function in dogs with experimentally induced congestive heart failure. Gated radionuclide ventriculography measurements of right ventricular function (right ventricular ejection fraction, right ventricular average emptying rate, and right ventricular average filling rate) were related to standard hemodynamic and echocardiographic measurements. Congestive heart failure was induced by rapid ventricular pacing in eight normal dogs. Hemodynamic, echocardiographic, and gated radionuclide ventriculography measurements were obtained before and after development of biventricular failure. Congestive heart failure resulted in significant changes in all hemodynamic, echocardiographic, and gated radionuclide ventriculography measurements with the exception of systemic arterial pressure. Right ventricular ejection fraction was inversely related to pulmonary artery systolic, diastolic, and mean pressure, and right ventricular average emptying rate was inversely related to the pulmonary artery systolic, diastolic, and mean pressure. Right ventricular ejection fraction was inversely related to left ventricular filling pressure, (pulmonary capillary wedge pressure). Neither the echocardiographic measurements of right ventricular size (right ventricular internal diastolic dimension) nor the right ventricular end-diastolic pressure were related to right ventricular ejection fraction and right ventricular average emptying rate. However, echocardiographic measurements of right ventricular dimension were related to right ventricular filling pressure. The gated radionuclide ventriculography indexes of right ventricular function, right ventricular ejection fraction and right ventricular average emptying rate, are affected by afterload but unaffected by preload, whereas the echocardiographic measurement of right ventricular dimension is related to preload. Gated radionuclide ventriculography provides right ventricular data which is unique from that obtained by standard echocardiographic imaging. Also, gated radionuclide ventriculography has potential value as a noninvasive means of estimating a change in pulmonary artery pressure.  相似文献   

5.
The growth of the heart, relative to body weight, was measured by M-mode echocardiography in dogs during the first year of life. Echocardiographic measurements were obtained from 16 English Pointers at 1, 2, 4, and 8 weeks of age and at 3, 6, 9, and 12 months of age. Left atrial (LA), aortic (AO), left and right ventricular internal dimensions, interventricular septal and left ventricular wall thickness measurements increased in curvilinear fashion relative to increasing body weight. Least-squares regression analysis, performed on logarithmically transformed data, was used to develop power-law equations describing the relationship of echocardiographic measurements to body weight. Linear dimensions of the LA, AO, left and right ventricular internal dimensions and interventricular septal and left ventricular wall thickness changed proportionally to slightly differing exponential powers of body weight (BW), varying from 0.31 to 0.45 (BW0.31 to BW0.45). Fractional shortening and the LA to AO ratio decreased slightly, but significantly, as body weight increased. Indexing echocardiographic measurements to BW1/3 was more appropriate than indexing such measures linearly to body weight, offering a practical method for developing accurate normative graphs or tables for M-mode echocardiographic dimensions in growing dogs.  相似文献   

6.
Objective To study the echocardiographic effects of isoflurane at an end‐tidal concentration approximating 1.0 times the minimum alveolar concentration (MAC) in healthy unpremedicated dogs. Study design Prospective experimental trial. Animals Sixteen mature mongrel dogs of either sex weighing 11.06 ± 2.72 kg. Methods After performing a baseline echocardiogram in the awake animal, anesthesia was induced with increasing inspired concentrations of isoflurane via a face mask until tracheal intubation was possible. Following intubation, the end‐tidal concentration was decreased to 1.4% for the rest of the anesthetic period. Serial echocardiograms were recorded at 25, 40, and 55 minutes after the end‐tidal concentration was reached. Results No changes were observed in heart rate. However, significant decreases were seen in left ventricular end‐diastolic diameter (Mean maximal change: 13.8%), interventricular septal thickness during systole (15.2%), interventricular septal thickening fraction (72.2%), left ventricular free wall thickening fraction (63.5%), ejection fraction (39.9%), and fractional shortening (46.7%). In addition, peak flow velocities across mitral, pulmonic, and aortic valves were significantly lower than baseline values. Decreases were also observed in end‐diastolic left ventricular volume index (approximately 32.1% from the awake value), stroke index (58.2%), and cardiac index (55.3%) when compared with awake measurements. Conclusions and clinical relevance Our results indicate that 1 × MAC isoflurane caused significant myocardial depression in healthy dogs. These changes in myocardial function need to be considered carefully when isoflurane is to be used in dogs with poor cardiovascular reserve.  相似文献   

7.
An M-mode echocardiographic examination was performed in a consistent manner in 30 clinically healthy cats under light ketamine hydrochloride sedation. There was a significant linear relationship between increasing body size and increasing cardiac dimensions for several echocardiographic values. Positive correlation existed between body weight and body surface area with aortic root, left ventricular caudal wall thickness (LVCW), interventricular septal thickness (IVS), IVS/LVCW, and mean velocity of circumferential fiber shortening (Vcf); there was a negative correlation between body weight and body surface area with left ventricular ejection time (LVET). Body surface area also correlated positively with percentage of ventricular minor axis dimensional change (% delta D). Positive correlations were recorded between left ventricular end-diastolic dimension (LVEDD) and left ventricular endsystolic dimension (LVESD), LVESD and LVET, LVCW and IVS, LVET (calculated by LVCW motion) and LVET (calculated by aortic valve motion), % delta D and Vcf, heart rate and Vcf, and Vcf (calculated using aortic valve motion to compute LVET) and Vcf (using LVCW motion to compute LVET). There were negative correlations between LVEDD and % delta D, LVEDD and Vcf, LVESD and Vcf, LVET and Vcf, LVET and heart rate, LVET and % delta D. Significant differences were recorded between means of echocardiographic reference values generated in this and other studies, except for LVESD.  相似文献   

8.
Echocardiographic parameters were compared between training and non-training greyhound dogs. When indexed to body weight there was a statistically significant increase (p<0.05) in the interventricular septal thickness (systole) and when indexed to body surface area there were increased interventricular septal (systole) and left ventricular free wall measurements (systole) in training compared with non-training greyhounds. When each gender was analyzed separately and echocardiographic parameters were indexed to body size, both genders had an increase in the interventricular septal thickness (diastolic in the female, systolic in the male) in the training compared with non-training greyhounds. In male training greyhounds there was additionally an increase in the left ventricular internal dimension (systole) and free wall thickness (systole) when echocardiographic parameters were indexed to body surface area compared with non-training greyhounds (p<0.05). The results indicate that certain training greyhound echocardiographic parameters are larger than non-training greyhound echocardiographic parameters. The potential effects of training, body size and gender should be considered when interpreting echocardiographic parameters in populations of greyhounds.  相似文献   

9.
OBJECTIVE: To evaluate the effects of positioning and number of repeated measurements on intra- and interobserver variability of echocardiographic measurements in dogs. DESIGN: Prospective study. ANIMALS: 4 healthy dogs. PROCEDURE: Each observer performed 24 examinations, separately assessing each dog 6 nonconsecutive times (3 times with the dog in lateral recumbency and 3 with the dog in a standing position). Variables evaluated included M-mode measurements of left ventricular end-diastolic and left ventricular end-systolic diameters, left ventricular free-wall thickness in diastole and systole, interventricular septal thickness in diastole and systole, left ventricular shortening fraction, and 2-dimensional measurements of the left atrial diameter-to-aortic diameter ratio. RESULTS: All coefficients of variation (range, 3.4% to 26.6%) were similar between operators and positions and were < 15% for 27 of 32 values. For both operators, repeatability of the measurements was better for left ventricular end-systolic diameter, left ventricular free-wall thickness in diastole, left ventricular free-wall thickness in systole, and the left atrial diameter-to-aortic diameter in the standing position, and similar for both positions for shortening fraction and left ventricular end-diastolic diameter. No effect of cardiac cycle was observed. CONCLUSIONS AND CLINICAL RELEVANCE: Within-day variability of conventional echocardiography performed with the dog in the standing position was at least as good as that obtained with the dog in lateral recumbency for most measured variables. Single measurements of each variable may be sufficient for trained observers examining dogs that do not have an arrhythmia. The standing position should be used, particularly for stressed or dyspneic dogs.  相似文献   

10.
Objectives : To assess the influence of body surface area, age and gender on echocardiographic parameters and to establish echocardiographic reference values for dogue de Bordeaux dogs. Methods : Thirty‐nine healthy dogue de Bordeaux dogs of both sexes, older than one year, were recruited and 31 of these were included in the study. The classic linear regression model proved to be the best way to analyse the data. The reference limits of the echocardiographic measurements were calculated using the regression equations. The difference between the mean values of body surface area in both gender groups was evaluated by using one‐way ANOVA. Results : A significant correlation was seen between several echocardiographic parameters and body surface area or body surface area and age, and high coefficients of determination (R2) were found. No effect of gender was detected on echocardiographic variables, except for the thickness of the left ventricular posterior wall at end diastole. Clinical Significance : The echocardiographic parameters related to body surface area, in the absence of correlation with other independent variables (gender and age) should be interpreted with caution because their variation could be significant for the presence of heart disease. The proposed statistical model allows estimation of echocardiographic parameters in dogue de Bordeaux dogs with different body surface areas and ages.  相似文献   

11.
BackgroundEchocardiography is a primary tool used by veterinarians to evaluate heart diseases. In recent years, various studies have targeted standard echocardiographic values for different breeds. Reference data are currently lacking in Maltese dogs and it is important to fill this gap as this breed is predisposed to myxomatous mitral valve disease, which is a volume overload disease.ObjectivesTo establish the normal echocardiographic parameters for Maltese dogs.MethodsIn total, 23 healthy Maltese dogs were involved in this study. Blood pressure measurements, thoracic radiography, and complete transthoracic echocardiography were performed. The effects of body weight, age and sex were evaluated, and the correlations between weight and linear and volumetric dimensions were calculated by regression analysis.ResultsThe mean vertebral heart size was 9.1 ± 0.4. Aside from the ejection fraction, fractional shortening, and the left atrial to aorta root ratio, all the other echocardiographic parameters were significantly correlated with weight.ConclusionThis study describes normal echocardiographic parameters that may be useful in the echocardiographic evaluation of Maltese dogs.  相似文献   

12.
Echocardiographic evaluation of healthy, nonexercising, awake greyhounds revealed substantial differences in left ventricular cavity dimensions, wall thickness, systolic time intervals and fractional shortening as compared to previously reported normal echocardiographic values obtained from mongrels and various other dog breeds. Despite corrections for body surface area and body weight, these differences remained, suggesting that breed and body conformation should be considered when interpreting echocardiographic studies in the dog.  相似文献   

13.
Body weight, heart rate, and 19 M-mode echocardiographic variables were measured in 41 nonanesthetized healthy cats. Estimated limits were determined for the echocardiographic variables, and each variable was then correlated to body weight, heart rate, and the 18 other variables. A significant (P less than 0.05) positive correlation to body weight was found with aortic diameter, left atrial dimension, septal and left ventricular systolic and left ventricular diastolic wall thicknesses, and left and right ventricular diastolic and right ventricular systolic internal dimensions. Significant inverse correlation (P less than 0.05) to heart rate was found with body weight, left ventricular systolic and diastolic and right ventricular systolic internal dimensions, left atrial dimension, left atrial dimension to aortic ratio, mitral valve E point to ventricular septal separation, and left ventricular ejection time. Left ventricular shortening fraction in the short axis and velocity of circumferential fiber shortening were significantly correlated (P less than 0.05) to heart rate. Significant correlation (P less than 0.05) was also found between many echocardiographic variables.  相似文献   

14.
Seventeen clinically normal adult English Cocker Spaniels from a kennel population with a history of cardiomyopathy were assessed, using M-mode echocardiography, to establish reference values for left ventricular (LV) dimensions for this breed of dog. Echocardiographic measurements were compared with postmortem measurements in 10 of 17 dogs. The LV weight calculated from the echocardiographic measurements correlated significantly with LV weight at postmortem (P less than 0.05). Echocardiographic measurements of end diastolic and end systolic diameters for the 17 dogs correlated significantly with body surface area (P less than 0.01). Measurements of the interventricular septum were in close agreement with values in clinically normal dogs and were significantly correlated with postmortem measurements (r = 0.94, P less than 0.01). However, 76% of the measurements for LV caudal wall thickness in this group of dogs were above the normal range. Calculation of fractional shortening values identified a group of 5 dogs with reduced fractional shortening (mean +/- SD, 20.97 +/- 3.66%), which indicates that a depression in contractility may be present in some apparently healthy dogs of this kennel population. The remaining 12 dogs had fractional shortening values of mean +/- SD, 34.26 +/- 4.54%.  相似文献   

15.
OBJECTIVE: To determine the within-day and between-day variability of regurgitant fraction (RF) assessed by use of the proximal isovelocity surface area (PISA) method in awake dogs with degenerative mitral valve disease (MVD), measure RF in dogs with MVD, and assess the correlation between RF and several clinical and Doppler echocardiographic variables. DESIGN: Prospective study. ANIMALS: 6 MVD-affected dogs with no clinical signs and 67 dogs with MVD of differing severity (International Small Animal Cardiac Health Council [ISACHC] classification). PROCEDURES: The 6 dogs were used to determine the repeatability and reproducibility of the PISA method, and RF was then assessed in 67 dogs of various ISACHC classes. Mitral valve regurgitation was also assessed from the maximum area of regurgitant jet signal-to-left atrium area (ARJ/LAA) ratio determined via color Doppler echocardiographic mapping. RESULTS: Within- and between-day coefficients of variation of RF were 8% and 11%, respectively. Regurgitation fraction was significantly correlated with ISACHC classification and heart murmur grade and was higher in ISACHC class III dogs (mean +/- SD, 72.8 +/- 9.5%) than class II (57.9 +/- 20.1%) or I (40.7 +/- 19.2%) dogs. Regurgitation fraction and left atriumto-aorta ratio, fractional shortening, systolic pulmonary arterial pressure, and ARJ/LAA ratio were significantly correlated. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that RF is a repeatable and reproducible variable for noninvasive quantitative evaluation of mitral valve regurgitation in awake dogs. Regurgitation fraction also correlated well with disease severity. It appears that this Doppler echocardiographic index may be useful in longitudinal studies of MVD in dogs.  相似文献   

16.
In dogs with experimentally induced heartworm infection, the onset of caval syndrome (CS) was characterized by a murmur, loudest over the tricuspid valve, and a large worm mass in the right ventricular lumen detectable during diastole by use of M-mode echocardiography. Two-dimensional echocardiography indicated that the worm mass was located in the right atrium and venae cavae and was "flowing" into the right ventricle during rapid diastolic filling. Paradoxical septal motion and vigorous right ventricular cranial wall motion also were observed. Other echocardiographic changes included decreased size of the left atrium and ventricle, aortic root, and ratio of left-to-right ventricular diastolic luminal diameter, compared with values obtained 6 months after experimentally induced heartworm infection. Right ventricular end diastolic diameter increased considerably. Most echocardiographic indices of left ventricular function (fractional shortening, velocity of circumferential fiber shortening, ejection fraction, and preejection period) were not altered appreciably, but estimates of cardiac index and stroke volume were markedly decreased. Electrocardiography revealed ventricular and supraventricular premature complexes in 7 of the 8 dogs studied, evidence of right ventricular enlargement in 6 of the 8 dogs studied, and increased mean heart rate, compared with that measured 6 months after inoculation of infective larvae, before the onset of CS. Cardiac catheterization was performed in 3 days at the onset of CS. Severe pulmonary arterial and right ventricular hypertension and decreased cardiac index (compared with values obtained before inoculation) were observed. Evidence of right ventricular inflow obstruction was not detected. Mean aortic blood pressure decreased with the onset of CS, but right ventricular end diastolic pressure increased.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

17.
Owing to the development of Greyhounds as racing sighthounds, these dogs have acquired unique physiologic adaptations that distinguish them from other breeds. Reference intervals for many analytes in retired racing Greyhounds (RRGs) differ from those of other breeds; most of the hematologic differences have also been described in other sighthounds. In this review, we provide a survey of the literature on clinical pathology of Greyhounds and other sighthounds and results of laboratory testing, including analysis of CBCs, biochemical profiles, coagulation tests, and blood gases, in RRGs at The Ohio State University. Major clinicopathologic differences in this breed include higher RBC mass, creatinine concentration, glomerular filtration rate, activities of hepatic enzymes, and concentration of cardiac troponin, as well as lower WBC, neutrophil, and platelet counts, thromboelastographic values, and concentrations of serum haptoglobin, total globulins, and T4.  相似文献   

18.
M-mode echocardiograms were recorded from 40 healthy dogs, awake and unsedated, in left lateral recumbent position. Fifteen echocardiographic measurements were taken and correlated with body weights using linear regression equations. The left ventricular internal dimension in systole and diastole, the left ventricular wall thickness, the aortic root dimension, and the left atrial dimension had high correlation coefficients (r2), ranging from 0.756 to 0.619. The fractional shortening of the left ventricle in systole (39% +/- 6%) and the left atrial to aortic root ratio (0.99 +/- 0.10) were not linearly related to body weights and had constant values.  相似文献   

19.
OBJECTIVE: To determine M-mode and Doppler echocardiographic reference values in healthy New Zealand white rabbits. ANIMALS: 52 healthy male rabbits. PROCEDURES: The rabbits were anesthetized and M-mode measurements of the left ventricle, left atrium, and aorta and Doppler measurements of pulmonary and aortic outflow and mitral inflow were recorded. RESULTS: Mean +/- SD heart rate during echocardiographic examination was 155 +/- 29 beats/min. Mean +/- SD measurements in diastole and systole for the interventricular septum thickness, left ventricular internal diameter, and left ventricular free wall thickness were 2.03 +/- 0.37 mm and 3.05 +/- 0.45 mm; 14.37 +/- 1.49 mm and 10.25 +/- 1.22 mm; and 2.16 +/- 0.25 and 3.48 +/- 0.55 mm, respectively. Mean +/- SD left atrial-to-aortic diameter ratio was 1.17 +/- 0.14, and mean +/- SD mitral valve E-point-to-septal separation interval was 1.71 +/- 0.29 mm. Mean +/- SD for fractional shortening and ejection fraction were 30.13 +/- 2.98% and 61.29 +/- 4.66%, respectively. Mean +/- SD maximal aortic and pulmonary artery outflow velocities were 0.85 +/- 0.11 m/s and 0.59 +/- 0.10 m/s, respectively, and the peak E-to-peak A wave velocity ratio of the mitral valve was 2.19 +/- 0.46. CONCLUSIONS AND CLINICAL RELEVANCE: Results provide echocardiographic reference values for young adult male New Zealand white rabbits anesthetized with ketamine and medetomidine. Values obtained from unanesthetized rabbits, rabbits sedated with other agents, or rabbits of different size may differ from those reported here.  相似文献   

20.
M-mode echocardiography was used to assess apical mitral annulus motion (MAM) in 103 normal dogs and 101 dogs with cardiac disease, to obtain information on systolic left ventricular long axis function. In normal dogs, a close relationship was found between MAM and body weight (r = 0.80, P < 0.001). There was a weak correlation between MAM and heart rate (r = -0.25, P < 0.05), but no correlation between MAM and age or left ventricular shortening fraction (P > 0.05). Mean MAM (95% confidence intervals) were established for normal dogs of differing body weight, and were 0.70 cm (0.65 to 0.75) in dogs < 15 kg, 1.08 cm (1.03 to 1.13) in dogs weighing 15 to 40 kg, and 1.51 cm (1.21 to 1.81) in dogs > 40 kg. "Cut-off" values to define decreased MAM for normal dogs of differing body weight were 0.45 cm (dogs < 15 kg), 0.80 cm (dogs 15-40 kg), and 1.20 cm (dogs > 40 kg). In dogs with cardiac disease, median MAM was normal in mitral valve endocardiosis or aortic stenosis, but significantly decreased (P < 0.05) in dilated cardiomyopathy. All dogs with mitral valve endocardiosis (n = 54) or aortic stenosis (n = 26) had MAM above the above-mentioned "cut-off" values, suggesting normal or increased left ventricular longitudinal systolic shortening, whereas 81% (17/21) of dogs with dilated cardiomyopathy had MAM below the "cut-off" value, indicating decreased long axis systolic function. It is concluded that MAM may be used to evaluate systolic left ventricular long axis performance in dogs and may add useful information on global left ventricular contraction dynamics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号