首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到5条相似文献,搜索用时 0 毫秒
1.
Based on the damage assessment and strengthening scheme of the full-scale model which is the three-floor frame-supported reinforced concrete masonry short-leg shear wall structure, the strengthened model is tested using the substructure pseudo-dynamic testing method. The applicability of the proposed strengthening technique for the building damaged by earthquake is discussed. Thus, the seismic performance of the strengthened model is proposed to seek the strengthening technique for the structure damaged by earthquake, and it provides important reference for the post-disaster reconstruction after Wenchuan earthquake.  相似文献   

2.
To investigate mechanical behavior and seismic behavior of concrete filled steel tubular column node (CFSTCN) in space truss structure, both full-scale test and Finite Element Method (FEM) were employed. The test load was 1.6 times of design load and by incremental step loading. Meanwhile, stress and deformation in CFSTCN were observed to monitor bearing capacity of the node. The results show that steel tubular works in elastic state and a small part of concrete beyond of compressive stress limits; steel tube and concrete adhesive well. The hysteretic energy dissipation capacity and failure mode under cyclic loading were revealed by nonlinear FEM. weakest position and ultimate bearing capacity of the node were obtained from FEM results. The method of combining full-scale test and FEM can well reveal the mechanical behavior and the seismic behavior of the node.  相似文献   

3.
Based on the characteristics of spatial structure of residential units, the effect of building space construction on temperature raise and hot smoke flow in residential fire was analyzed on building model with simulating multiple floors and rooms. The raise and distribution of temperature indoors were mainly tested under varied location of fire sources. And, the rule of smoke flow was discussed by using the law of temperature raise, indirectly. The results indicate that the mode of smoke flows is influenced by three spatial factors which include the form of junction terminal room construction; the height of down stand above the door and the relative locations of each room. The diffusion of hot smoke is prevented effectively by the down stand of the room; the temperature difference between indoor and outdoor should be higher than that of the room without down stand. When the open direction of door in non fire room is opposite to that of the door in fire room, there is much more hot smoke.  相似文献   

4.
5.
A new good idea named Electro-hydraulic Impulse is described in the paper. Electro-hydraulic impulse is a process which integrates strong electrical field, strong magnetic field, ultrasonic wave, radiation of light and cavitation. With it, a kind of water named strongly polar activated water is generated. Using strongly polar activated water to make concrete blocks, the mechanical performance of concrete can be improved greatly. With the proper parameters, the compression strength of concrete can be increased by 48% percent. This has been proved by some experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号