首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ten experimental dogs were tested in twelve experimental arrangements, with a view to finding out the extent to which results of acid-base determination or blood gas analysis could be significantly affected by induced hyperaemia of the ear or by the choice of a site for blood collection, including puncture of an ear vein. No difference was secured. Hence, ear vein puncture may be used to collect so-called capillary blood. Reference is made to the author's own values for use as criteria.  相似文献   

2.
OBJECTIVE: To evaluate the analytical agreement between blood lactate concentrations determined by use of an enzymatic-amperometric bedside system in capillary blood samples from the pinna and in jugular venous blood samples from dogs. ANIMALS: 53 dogs. PROCEDURES: For each dog, venous and capillary blood samples were obtained from a jugular vein and from the ear pinna (by use of a lancing device), respectively, following a randomized sequence of collection. Lactate concentrations in both types of samples were analyzed by use of an enzymatic-amperometric bedside system intended for lactate detection in capillary blood samples from humans that was previously validated in dogs. The Passing-Bablock regression analysis was used to compare venous and capillary blood lactate concentrations; the level of agreement was calculated by use of the Bland-Altman method. RESULTS: Jugular venous blood samples were collected without difficulty from all 53 dogs. A capillary blood sample was obtained from only 47 dogs. The correlation coefficient between lactate concentrations measured in venous and capillary blood samples was 0.58 (slope, 2.0 [95% confidence interval, 1.5 to 3.0]; intercept, -1.2 [95% confidence interval, -3.1 to 0.4]). The mean difference between methods was 0.72 mmol/L (95% confidence interval, 0.38 to 1.06) with limits of agreement of -1.55 to 2.99 mmol/L. CONCLUSIONS AND CLINICAL RELEVANCE: Because of the lack of agreement between lactate concentrations determined in capillary and jugular venous blood samples, measurement of capillary blood lactate concentration in dogs performed with the technique used in the study does not appear to be a reliable alternative to jugular venous blood measurements.  相似文献   

3.
A method of arterial blood sampling acceptable for clinical purposes for acid-base estimations in dogs is described. A comparison of acid-base variables from fourteen canine arterial, venous and capillary blood samples revealed in most cases that venous and capillary blood samples showed unsatisfactory agreement with corresponding arterial blood samples. Two commercial automatic pH and blood-gas analysing systems are compared.  相似文献   

4.
OBJECTIVE: To compare direct measurements of canine oxyhemoglobin (HbO2) saturation and blood oxygen content (ContO2) in healthy dogs with analyzer-calculated values derived by use of a human HbO2 relationship and with hand-calculated values derived by use of a canine HbO2 relationship. ANIMALS: 17 healthy dogs. PROCEDURE: 3-mL samples of heparinized arterial and jugular venous blood were collected from each dog. The pH, Pco2, Po2, hemoglobin, HbO2, carboxyhemoglobin, methemoglobin, and ContO2 were measured; HbO2 and ContO2 were calculated automatically by analyzers and also hand-calculated. Blood gas analyzer-calculated and hand-calculated HbO2 values were compared with co-oximeter-measured HbO2 values. Analyzer-calculated and hand-calculated ContO2 values were compared with oxygen content analyzer-measured values. RESULTS: Hand-calculated HbO2 values for arterial and jugular venous samples were slightly but significantly lower than those calculated by a blood gas analyzer or obtained from a co-oximeter. Hand-calculated and analyzer-calculated arterial and venous ContO2 were similar to measured values. CONCLUSIONS AND CLINICAL RELEVANCE: Although certain HbO2 and ContO2 values generated by use of the different methods were significantly different, these differences are unlikely to be clinically important in healthy dogs.  相似文献   

5.
A technique for collection of blood samples from the cut claw of the cat was developed. Forty-six blood samples were collected simultaneously from the cut claw and the femoral artery of 7 healthy cats. Blood gas and pH values were measured and compared. There was no difference between sample pairs for blood PO2 and PCO2, but the pH values were significantly (P less than 0.001) higher in the capillary samples (7.432 +/- 0.033) than in the samples from the femoral artery (7.419 +/- 0.031).  相似文献   

6.
The objective of this study was to investigate whether home monitoring of blood glucose of diabetic dogs by owners would be possible on a long-term basis. The owners of 12 diabetic dogs were each asked to generate four glucose curves by taking capillary blood samples from their dog's ear, at three- to four-week intervals. Within one week of each curve being produced by the owner, an additional curve was produced by a veterinarian in the hospital. Ten owners were able to generate blood glucose curves; three of them needed a second demonstration, and two telephoned for further guidance. The blood glucose concentrations obtained from the first two 'hospital' curves were significantly lower than those measured at home. Overall, in 42 per cent of cases, the treatment based on the hospital curves would have been different from that based on 'home' curves. The results of this study indicate that the majority of owners were able and willing to perform long-term monitoring of the blood glucose concentrations of their dogs.  相似文献   

7.
The accuracy of a portable blood gas analyzer (OPTI 1) was evaluated using canine blood and aqueous control solutions. Sixty-four arterial blood samples were collected from 11 anesthetized dogs and were analyzed for pH, partial pressure of carbon dioxide (PCO2) partial pressure of oxygen (PO2), and bicarbonate concentration ([HCO3-]) values by the OPTI 1 and a conventional blood gas analyzer (GASTAT 3). The conventional analyzer was considered as a standard against which the OPTI 1 was evaluated. Comparison of OPTI 1 results with those of GASTAT 3 by linear regression analysis revealed a high degree of correlation with the GASTAT 3 (r = .90-.91). The mean +/- SD of the differences between OPTI 1 and GASTAT 3 values was -0.008 +/- 0.017 for pH, -0.88 +/- 3.33 mm Hg for PCO2, 3.71 +/- 6.98 mm Hg for PO2, and -0.34 +/- 1.45 mEq/L for [HCO3-]. No statistically significant difference was found between the OPTI 1 and the GASTAT 3. Agreement between these 2 methods is within clinically acceptable ranges for pH, PCO2, PO2, and [HCO3-]. The coefficients of variation for measured pH, PCO2, and PO2 values of 3 aqueous control solutions (acidic, normal, and alkalotic) analyzed by the OPTI 1 ranged from 0.047 to 0.072% for pH, 0.78 to 1.81% for PCO2, and 0.73 to 2.77% for PO2. The OPTI 1 is concluded to provide canine blood gas analysis with an accuracy that is comparable with that of conventional benchtop blood gas analyzers.  相似文献   

8.
A multichannel, semiautomated, blood cell counting system (Coulter Counter Model S550) was modified for use in veterinary hematology by increasing both the erythrocyte and leukocyte aperture currents to 225 V and 195 V, respectively, followed by calibration with human blood. It was evaluated by use of 350 samples from dogs, cats, horses, and cows. Values for leukocyte count, erythrocyte count, mean corpuscular volume, and hematocrit generated by the S550 were compared with values generated by an automated multichannel counter with histogram capability and other reference procedures when appropriate. Mean differences for values between S550 and reference values were less than calibration tolerance limits for the instrument. Correlation coefficients were excellent for all values of each species. To assess behavior of leukocytes of the different species with respect to the counting threshold, leukocyte size distribution histograms were generated for all samples analyzed on the S550. Means for mean leukocyte volumes in diluent and lysing reagents were 55.5, 56.6, 67.4, and 72.8 fl for dogs, cats, horses, and cows, respectively. Canine leukocyte counts, because of small leukocyte size, were an average of 14% less for 5 samples analyzed on the unmodified instrument, compared with analysis after increasing the leukocyte aperture current. Leukocyte threshold failures attributable to interfering particles, resulting in falsely high counts, were recognized in 14%, 10%, 8% and 0% of feline, bovine, canine, and equine samples, respectively. The magnitude of error in these samples averaged 5% for cows and dogs, but was considered not important. However, leukocyte counts of feline samples in this group averaged 44% falsely high.  相似文献   

9.
The objectives of this study were to determine whether a 13C-aminopyrine demethylation blood test is technically feasible in clinically healthy dogs, whether oral administration of 13C-aminopyrine causes a detectable increase in percent dose/min (PCD) of 13C administered as 13C-aminopyrine and recovered in gas extracted from blood, and whether gas extraction efficiency has an impact on PCD. A dose of 2 mg/kg body weight of 13C-aminopyrine dissolved in deionized water was administered orally to 6 clinically healthy dogs. Blood samples were taken from each dog 0, 30, 60, and 120 min after administration of the 13C-aminopyrine. Carbon dioxide was extracted from blood samples by addition of acid and analyzed by fractional mass spectrometry. None of the 6 dogs showed any side effects after 13C-aminopyrine administration. All 6 dogs showed a measurable increase of the PCD in gas samples extracted from blood samples at 30 min, 60 min, and 120 min after 13C-aminopyrine administration. Coefficients of variation between the triplicate samples were statistically significantly higher for the %CO2, a measure of extraction efficiency, than for PCD values (P < 0.0001). The 13C-aminopyrine demethylation blood test described here is technically feasible. Oral administration of 13C-aminopyrine did not lead to gross side effects in the 6 dogs. Clinically healthy dogs show a measurable increase of PCD in gas extracted from blood samples after oral administration of 13C-aminopyrine. Efficiency of CO2 extraction from blood samples does not have an impact on PCD determined from these blood samples. This test may prove useful to evaluate hepatic function in dogs.  相似文献   

10.
The dog is widely used as a translational experimental model studying the host response and new treatments for human endotoxemia. The present study evaluated the applicability of a novel patient-near neutrophil chemiluminescence assay for the measurement of endotoxin activity in human blood when applied to canine blood samples. The assay was observed to be analytically sensitive and specific to endotoxin when tested in vitro, spiked with purified Escherichia coli lipopolysaccharide and live E. coli. The diagnostic sensitivity was sustained during Gram-positive contamination. Finally, it also demonstrated diagnostic potential when able to discriminate dogs with spontaneously occurring endotoxemia from both healthy dogs and diseased dogs without endotoxemia. The rapid patient-near assessment of endotoxin activity in canine blood should facilitate future studies on endotoxemia in both spontaneous disease and in experimental settings.  相似文献   

11.
In human medicine, diagnosis of diabetic ketoacidosis (DKA) is usually based on measurement of capillary 3-β-hydroxybutyrate (3-HB) with a hand held ketone sensor. This study was conducted to determine if measurement of capillary 3-HB could be useful for the diagnosis and monitoring of canine DKA. Fifteen dogs with diabetic ketosis and 10 with DKA were evaluated. Paired measurements of 3-HB of capillary and venous blood samples were analysed by the electrochemical sensor and reference method. Use of capillary 3-HB measurement during DKA management was then evaluated through simultaneous measurements of capillary 3-HB, urinary AcAc and venous blood gas analysis. Good agreement between capillary and venous 3-HB measurement was detected by the electrochemical sensor and reference method. Monitoring treatment of DKA revealed a significant correlation between capillary 3-HB and acidosis markers, while no significant correlation was observed between AcAc and acidosis markers. A cut-off value of capillary blood 3-HB >3.8 mmol/L for diagnosis of DKA resulted in 70% and 92% sensitivity and specificity. The electrochemical sensor accurately measures 3-HB concentration in both capillary and venous blood samples, is accurate in diagnosing canine DKA, and appears to reflect the patient''s metabolic status during DKA treatment.  相似文献   

12.
OBJECTIVE: To evaluate the effect of dilution of blood samples with sodium heparin on blood gas, electrolyte, and lactate measurements in dogs. Sample Population-Venous blood samples collected from 6 adult dogs of various breeds. PROCEDURE: Syringes were prepared with anticoagulant via 1 of 4 techniques, and the residual volume of liquid heparin in each type of prepared syringe was determined. Blood gas values and other selected clinicopathologic variables were measured in whole blood samples after collection (baseline) and after aliquots of the samples were diluted with heparin via 1 of the 4 manual syringe techniques. By use of a tonometer, whole blood samples were adjusted to 1 of 3 oxygen concentrations (40, 100, or 600 mm Hg) and the PO2 values were measured at baseline and subsequent to the 4 heparin dilutions. RESULTS: The 4 syringe techniques resulted in 3.9%, 9.4%, 18.8%, and 34.1% dilutions of a 1-mL blood sample. Compared with baseline values, dilution of blood samples with liquid heparin significantly changed the measured values of PCO2, PO2, and base deficit and concentrations of electrolytes and lactate. Of the variables assessed, measurement of ionized calcium concentration in blood was most affected by heparin dilution. CONCLUSIONS AND CLINICAL RELEVANCE: These findings in dogs indicate that dilution of blood samples with heparin can be a source of preanalytical error in blood gas, electrolyte, and lactate measurements. Limiting dilution of blood samples with heparin to < 4% by volume via an evacuation technique of syringe heparinization is recommended.  相似文献   

13.
The purpose of this study is to report the aterial blood gas findings in dogs with bacterial pneumonia. Arterial blood gas samples were collected from 62 dogs with culture-confirmed bacterial pneumonia. These results were compared with 46 normal dog arterial blood gas samples. Results demonstrated that respiratory acidosis was not a problem in dogs with pneumonia in this study. Significant evidence of hypoxemia was noted with abnormal mean values in PaO2 (P<0.001) and the Alveolar-arterial (A-α) gradient (P<0.001).  相似文献   

14.
Background: The Reflovet system is designed for chemical analysis of whole blood. However, plasma or serum is recommended for potassium analysis because of possible interference from RBC potassium. Because RBC potassium concentration is low in most canine erythrocytes, however, there should be little or no interference.
Objective: The objective of this study was to compare potassium results obtained in whole blood and in plasma from dogs using the Reflovet system.
Methods: Blood samples were collected from 104 dogs into lithium-heparin tubes. The potassium concentration was measured in whole blood, and subsequently the PCV was measured. Samples were centrifuged and the potassium concentration was measured in plasma. Comparisons were made using Deming's regression and Bland-Altman difference plots.
Results: There was very good correlation between results of potassium measurements in whole blood and plasma ( r = 0.93). Potassium values were moderately lower in whole blood: Potassiumblood= 0.912 × Potassium plasma+ 0.119. Hemolysis had a negligible effect on the results, but the difference increased with the PCV value. In more than 90% of samples, the difference between the 2 measurements was ≤ 0.3 mmol/L.
Conclusion: There is only a negligible difference in most cases between potassium values in canine plasma and whole blood using the Reflovet system.  相似文献   

15.
Erythrocyte sedimentation rates of canine and feline blood were measured by the Wintrobe method and by a capillary method utilizing 75 times 1 mm microhaematocrit tubes. Results obtained with each method were generally similar for both species.
The erythrocyte sedimentation rate (ESR) with the Wintrobe method as well as with the capillary method was inversely related to the packed cell volume (PCV), i. e., the lower the PCV, the higher the ESR. However, there was no consistent relationship between the ESR values obtained by the two methods at all levels of PCV. Wintrobe ESR values were slightly higher than capillary tube values for canine blood having a PCV of 36-60% and for 'reconstituted' canine and feline bloods having a high PCV. In contrast, capillary tube ESR values were slightly higher than Wintrobe values for 'reconstituted' canine blood having a PCV of 8-38 % and for feline blood with a PCV below 30%. It was, therefore, concluded that ESR values obtained by the two methods cannot be considered equivalent.
Only a slight decrease occurred in the ESR of blood held at 4°C for 2-6 hours, whereas the ESR of blood held at room temperature dropped markedly and blood stored for 24 hours at either temperature consistently gave lower values. Therefore, it is recommended that if the ESR cannot be determined soon after sampling, the blood should be stored at 4°C and the test conducted within 6 hours.  相似文献   

16.
For the measurement of canine blood volume, various experimental conditions and techniques have been investigated using a non radioactive stable isotope 50Cr. On the basis of the results in this preliminary work, erythrocytes were labeled using 50Cr. Five micrograms of 50Cr per 1 ml of blood was added and incubated for 60 min. The canine erythrocytes were tagged using 50Cr and injected into vein of the same dogs. The blood samples collected at 60 min after the injection were irradiated by thermal neutron for 20 min at the reactor of the JAERI. Activities of 51Cr (the 50Cr concentration method) and 51Cr/59Fe radioactivity ratios (the 51Cr/59Fe ratio method) in the samples were measured. There was a very high correlation (r = 0.97, P less than 0.001) between the blood volumes calculated by the 50Cr concentration method and the 51Cr/59Fe ratio method. The latter method is less complicated than the former, because measurement of the sample weight and correction of thermal neutron flux are unnecessary. The mean blood volumes calculated by the ratio method and the Evans blue method were 89.8 +/- 6.8 ml/kg B.W. (mean +/- SD) and 98.9 +/- 10.6 ml/kg, respectively, showing a significant difference between them (P less than 0.05). However, these values are almost in accord by correction of venous blood PCV values with factor 0.97. As a detection limit of 50Cr was approximately 0.1 ng per 1 ml of blood in this system, this method has been concluded to be applicable to the measurement of the blood volume of cattle.  相似文献   

17.
Polymerase chain reaction (PCR) was first applied to diagnosis of canine babesiosis in Japan. Blood samples from 13 dogs suffering from canine babesiosis were used for examination of specificity and sensitivity of the PCR diagnosis. Of the 13 dogs, three were experimentally infected, and ten were naturally infected with Babesia species in west part of Japan. We designed a nested PCR to amplify the babesial small subunit ribosomal RNA gene and found that only the nested PCR produced a visual band, which were not apparent by the first-round PCR to the positive samples. Specificity of the nested PCR was confirmed by amplification after the second-round PCR. Sensitivity of the nested PCR was examined by diluting the blood samples from infected and uninfected dogs. The nested PCR was found to show positive results on the most diluted blood at 0.0001% parasitemia. These results indicate that the nested PCR is highly sensitive and useful for diagnosis of canine babesiosis.  相似文献   

18.
Two new methods for collection of capillary blood from the ear of dogs and cats for the measurement of blood glucose concentration using portable blood glucose meters (PBGMs) are described. The first method uses a lancing device after pre-warming the ear, while the second employs a vacuum lancing device. Both methods generated blood drops of adequate size, although the latter method was faster and easier to perform. Accuracy of the two PBGMs was evaluated clinically and statistically. Although assessment of statistical accuracy revealed differences between the PBGMs and the reference method, all of the PBGM readings were within clinically acceptable ranges. Measurement of capillary blood glucose concentration is easy to perform, inexpensive and fast. It may be used by owners to determine blood glucose concentrations at home, and could serve as a new tool for monitoring diabetic dogs and cats.  相似文献   

19.
A method for assaying canine glycosylated haemoglobin was evaluated. The method is a turbidimetric inhibition immunoassay and the final reaction is bichromatically measured using a multichannel automatic analyser. Within-run coefficients of variation (2.07 to 4.46 per cent) were permissible, but between-run coefficients of variation (2.10 to 8.25 per cent) were slightly more elevated. The detection limit of this assay is 0.052 per cent. A sample dilution of 10 microliters of sample and 500 microliters of haemolysing reagent is recommended for routine analysis of canine blood samples. A normal reference interval of 1.39 +/- 0.70 per cent was obtained from the glycosylated haemoglobin analysis in 82 healthy dogs and no statistically significant differences in relation to age or gender were observed. Some changes in glycosylated haemoglobin concentrations were noted throughout the ovarian cycle, although differences between dogs were evident. Since this assay specifically measures the glycosylated haemoglobin content in canine blood samples, it could be very useful for monitoring diabetic dogs.  相似文献   

20.
Abstract: The objective of this study was to compare and assess the agreement between the Coulter AcT Diff hematology analyzer (CAD) and the Bayer Technicon H1 (H1) using blood samples from 391 animals of 4 species. The H1 has been used in veterinary laboratories for many years. Recently, Coulter modified the CAD and added veterinary software for hematologic analysis of feline, canine, and equine samples. A comparison of hemograms from dogs, cats, horses, and cattle was made using EDTA-anticoagulated blood samples. Both instruments were calibrated using human blood products. Performance characteristics were excellent for most values. The exceptions were MCV in canine samples (concordance correlation of .710), platelet counts for feline and equine samples (.258 and .740, respectively), feline and bovine WBC counts (.863 and .857, respectively), and bovine hemoglobin (.876).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号