1.
OBJECTIVE: To determine accuracy of an oscillometric blood pressure monitor used over a wide range of pressures in anesthetized cats. DESIGN: Prospective study. ANIMALS: 6 healthy cats. PROCEDURE: 4 female cats and 2 male cats that weighed 2.7 to 4.5 kg (5.9 to 9.9 lb) and were 2 to 8 years old were anesthetized. Blood pressure was measured directly with an arterial catheter placed in the right femoral artery and indirectly from the left antebrachium by use of an oscillometric monitor. A series of diastolic arterial pressure (DAP), mean arterial pressure (MAP), and systolic arterial pressure (SAP) measurements were obtained during hypotension, normotension, and hypertension. Values obtained indirectly and directly were compared. RESULTS: The oscillometric monitor was accurate for DAP and MAP throughout the entire pressure range and met the standards of the Association for the Advancement of Medical Instrumentation (mean +/- SD difference from values obtained directly, < or = 5 +/- 8 mm Hg). The SAP was increasingly underestimated with increasing overall pressure; mean differences from direct measurements were -5.2, -12.1, and -17.7 mm Hg during hypo-, normo-, and hypertension, respectively. Standard deviations for SAP were all < or = 8 mm Hg. The monitor gave readings during all attempts. The direct blood pressure recording system appeared to perform well with neither under- nor overdamping. CONCLUSIONS AND CLINICAL RELEVANCE: Except for a minor underestimation of SAP during normo- and hypertension, the oscillometric monitor yielded reliable and easily obtainable blood pressure measurements in anesthetized cats.  相似文献   

2.
Objective – To determine the accuracy and precision of an oscillometric noninvasive blood pressure device as a predictor of invasive direct blood pressure in healthy anesthetized hypotensive and normotensive dogs. Design – Prospective observational study. Setting – University teaching hospital. Animals – Eight crossbred adult dogs. Interventions – Anesthesia was induced with propofol and maintained with isoflurane. A catheter was placed in the dorsal pedal artery to record systolic, mean, and diastolic arterial blood pressures (aSAP, aMAP, and aDAP, respectively). The noninvasive blood pressure device cuff was placed around the contralateral front limb to record noninvasive systolic, mean, and diastolic blood pressure (nSAP, nMAP, and nDAP). Two states of blood pressure (BP) were studied: baseline state was established by keeping end‐tidal isoflurane concentration at 1.2±0.1%. The hypotensive state was achieved by maintaining the same isoflurane concentration while withdrawing approximately 40% of the animal's blood volume until aMAP was stable at approximately 40 mm Hg. At the end of the study, blood was returned to the animal and it was allowed to recover from anesthesia. Measurements and Main Results – Agreement between the direct and indirect BP measurements was determined by the Bland‐Altman method. The SAP and MAP but not DAP bias varied significantly between each BP state. Normotensive absolute biases (mean [SD]) for SAP, MAP, and DAP were ?14.7 mm Hg (15.5 mm Hg), ?16.4 mm Hg (12.1 mm Hg), and ?14.1 mm Hg (15.8 mm Hg), respectively. Absolute biases during the hypotensive state for SAP, MAP, and DAP were ?32 mm Hg (22.6 mm Hg), ?24.2 mm Hg (19.5 mm Hg), and ?16.8 mm Hg (17.2 mm Hg), respectively. Conclusion – The oscillometric device was not reliably predictive of intra‐arterial BP during hypotension associated with acute hemorrhage.  相似文献   

3.
OBJECTIVE: To compare intraocular pressure (IOP) measurements obtained with a rebound tonometer in dogs and horses with values obtained by means of applanation tonometry and direct manometry. DESIGN: Prospective study. ANIMALS: 100 dogs and 35 horses with clinically normal eyes, 10 enucleated eyes from 5 dogs, and 6 enucleated eyes from 3 horses. PROCEDURES: In the enucleated eyes, IOP measured by means of direct manometry was sequentially increased from 5 to 80 mm Hg, and IOP was measured with the rebound tonometer. In the dogs and horses, results of rebound tonometry were compared with results of applanation tonometry. RESULTS: For the enucleated dog and horse eyes, there was a strong (r2 = 0.99) linear relationship between pressures obtained by means of direct manometry and those obtained by means of rebound tonometry. Mean +/- SD IOPs obtained with the rebound tonometer were 10.8 +/- 3.1 mm Hg (range, 5 to 17 mm Hg) and 22.1 +/- 5.9 mm Hg (range, 10 to 34 mm Hg) for the dogs and horses, respectively. Mean IOPs obtained with the applanation tonometer were 12.9 +/- 2.7 mm Hg (range, 8 to 18 mm Hg) and 21.0 +/- 5.9 mm Hg (range, 9 to 33 mm Hg), respectively. Values obtained with the rebound tonometer were, on average, 2 mm Hg lower in the dogs and 1 mm Hg higher in the horses, compared with values obtained with the applanation tonometer. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that the rebound tonometer provides accurate estimates of IOP in clinically normal eyes in dogs and horses.  相似文献   

4.
OBJECTIVE: To examine the agreement between direct arterial blood pressure measurements obtained from 2 arteries and indirect blood pressure measurements obtained with an oscillometric blood pressure monitor (OBPM) during normotension and phenylephrine-induced hypertension in dogs. ANIMALS: 16 male Beagles. PROCEDURES: In anesthetized dogs, arterial catheters were placed in the lingual and dorsal pedal arteries for measurement of arterial blood pressure. A blood pressure cuff was placed on either the dog's fore- or hind limb and connected to an OBPM. Systolic, diastolic, and mean arterial blood pressures (SAP, DAP, and MAP, respectively) were recorded from both arteries and the OBPM every 5 minutes for 30 minutes (baseline), during a 30-minute period in which dogs received a phenylephrine infusion IV to induce hypertension, and for 30 minutes after discontinuation of the infusion. Mean differences in blood pressure values and confidence intervals were calculated to compare the indirect and direct measurement techniques. RESULTS: In dogs, oscillometry underestimated SAP during normotension, and the difference between oscillometric and direct measurements increased during hypertension. Oscillometry underestimated DAP, but the difference between oscillometric and direct measurements decreased during hypertension. There was close agreement among techniques for MAP determinations. Biases between direct measurements and OPBM blood pressure values measured from dogs' forelimbs or hind limbs were not significantly different. CONCLUSIONS AND CLINICAL RELEVANCE: In normotensive dogs, oscillometric measurements of MAP and SAP agreed more closely with direct arterial pressure measurements than oscillometric estimates of DAP. Oscillometric measurement of MAP was accurate during both normotension and hypertension in dogs.  相似文献   

5.
Postadulticide pulmonary hypertension mechanisms and treatment with antihistamines and supplemental oxygen were studied in eight dogs with heartworm disease. To ensure severe postadulticide thromboembolism, additional heartworms (either 20 or 40 into 4 dogs each) were transplanted into naturally infected dogs before thiacetarsamide treatment. During pentobarbital anesthesia, 2 pulmonary hemodynamic studies were conducted on each dog with a sequence of baseline, hypoxia with FlO2 = 10%, hyperoxia with FlO2 = 100%, a second baseline, treatment with either diphenhydramine (D) or cimetidine (C), and another hypoxia. All dogs were pulmonary hypertensive, with each dog having a mean pulmonary arterial pressure (PPA) greater than 20 mm of Hg. Mean PPA increased from baseline conditions (25.0 +/- 4.5 SD for D and 24.3 +/- 4.4 for C) to hypoxia (28.5 +/- 4.7 for D and 28.4 +/- 3.7 for C), and decreased during hyperoxia (16.9 +/- 3.0 for D and 17.4 +/- 3.0 for C), respectively. Neither antihistamine reduced PPA at normoxia. The degree of pulmonary hypertension when breathing room air increased even more during hypoxia, and this increase was not attenuated by either antihistamine. Histamine did not appear to mediate pulmonary hypertension during postadulticide thromboembolism, nor to modify the hypoxia-mediated pulmonary hypertension at this disease stage. Because baseline PO2 was low (66.6 +/- 11.7 mm of Hg for D and 69.4 +/- 14.2 for C) and because PPA decreased during administration of oxygen, the pulmonary hypertension was mostly hypoxia-induced. In addition to the arterial lesions, much of the pulmonary hypertensive mechanism was an active and reversible vasoconstriction in response to hypoxia caused by the secondary lung disease.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
OBJECTIVE: To determine arterial blood pressure in client-owned dogs, using direct arterial puncture, oscillometry, and Doppler ultrasonography in a clinical setting. DESIGN: Prospective study. ANIMALS: 8 clinically normal client-owned dogs. PROCEDURE: Blood pressures of nonsedated dogs were measured simultaneously, using each of the 3 methods. Mean values obtained were compared with published mean values. Ability of noninvasive methods (Doppler ultrasonography and oscillometry) to accurately predict results of the invasive method, and relationships between blood pressure and age, body weight, and degree of patient anxiety were determined. RESULTS: Calculated ranges of values (mean +/- 2 SD) determined by direct arterial puncture were: systolic pressure, 114 to 194 mm Hg; diastolic pressure, 66 to 102 mm Hg; and mean pressure, 85 to 129 mm Hg. Ranges determined by use of oscillometry were: systolic, 110 to 190 mm Hg; diastolic, 35 to 107 mm Hg; and mean, 78 to 138 mm Hg. Ultrasonographic and oscillometric values did not accurately predict direct values, but mean values of systolic and mean pressures were similar among methods. Relationships were not detected between age or body weight and blood pressure. Significant differences in blood pressure were not detected between anxious and nonanxious dogs. CONCLUSIONS AND CLINICAL RELEVANCE: Mean values of systolic, diastolic, and mean arterial blood pressure measured in nonsedated client-owned dogs, using invasive and noninvasive methods in a clinical setting, are comparable with those determined for acclimatized, trained, or sedated dogs. However, results of noninvasive methods may not accurately reflect direct values.  相似文献   

7.
OBJECTIVE: To compare the performance of the Surgivet Non-Invasive Blood Pressure (NIBP) monitor V60046 with an invasive blood pressure (IBP) technique in anaesthetized dogs. STUDY DESIGN: A prospective study. ANIMALS: Thirty-four dogs, anaesthetized for a variety of procedures. METHODS: Various anaesthetic protocols were used. Invasive blood pressure measurement was made using a catheter in the femoral or the pedal artery. A cuff was placed on the contralateral limb to allow non invasive measurements. Recordings of arterial blood pressures (ABPs) were taken at simultaneous times for a range of pressures. For analysis, three pressure levels were determined: high [systolic blood pressure (SAP) > 121 mmHg], normal (91 mmHg < SAP < 120 mmHg) and low (SAP < 90 mmHg). Comparisons between invasive and non invasive measurements were made using Bland-Altmann analysis. RESULTS: The NIBP monitor consistently underestimated blood pressure at all levels. The lowest biases and greatest precision were obtained at low and normal pressure levels for SAP and mean arterial pressure (MAP). At low blood pressure levels, the biases +/- 95% confidence interval (CI) were 1.9 +/- 2.96 mmHg (SAP), 8.3 +/- 2.41 mmHg diastolic arterial pressure (DAP) and 3.5 +/- 2.09 mmHg (MAP). At normal blood pressure levels, biases and CI were: 1.2 +/- 2.13 mmHg (SAP), 5.2 +/- 2.32 mmHg (DAP) and 2.1 +/- 1.54 mmHg (MAP). At high blood pressure levels, the biases and CI were 22.7 +/- 5.85 mmHg (SAP), 5.5 +/- 3.13 mmHg (DAP) and 9.4 +/- 3.52 mmHg (MAP). In 90.6% of cases of hypotension (MAP < 70 mmHg), the low blood pressure was correctly diagnosed by the Surgivet. CONCLUSIONS: Measurement of blood pressure with the indirect monitor allowed detection of hypotension using either SAP or MAP. The most accurate readings were determined for MAP at hypotensive and normal levels. The monitor lacked accuracy at high pressures. CLINICAL RELEVANCE: When severe challenges to the cardiovascular system are anticipated, an invasive method of recording ABP is preferable. For routine usage, the Surgivet monitor provided a reliable and safe method of NIBP monitoring in dogs, thereby contributing to the safety of anaesthesia by providing accurate information about the circulation.  相似文献   

8.
Intraocular pressure (IOP) was measured in 114 eyes of 57 clinically normal dogs with 2 applanation tonometers (Tono-Pen and Mackay-Marg) and the Schiotz indentation tonometer, using the 5.5- and 7.5-g weights. Significant differences were not detected between measurements obtained with the Tono-Pen and Mackay-Marg tonometers the Mackay-Marg and Schiotz tonometers using either weight and conversion with the human calibration table, or the Tono-Pen and Schiotz tonometers using the 7.5-g weight and the human calibration table. Values obtained by use of the Tono-Pen tonometer were significantly less (P less than 0.005) than values obtained with the Schiotz tonometer when a 5.5-g weight and the human calibration table were used, but the amount was clinically unimportant. Estimates of IOP using the Schiotz tonometer and the canine calibration table, and either the 5.5- or 7.5-g weight were clinically and significantly much higher (P less than 0.0001) than estimates obtained with the Tono-Pen, Mackay-Marg, or Schiotz tonometers, using the human calibration table and either weight. Sixty to 70% of clinically normal dogs had an IOP greater than or equal to 30 mm of Hg when Schiotz scale measurements were converted with the canine conversion table. For clinically normal dogs, the human calibration table was the most clinically useful table for converting Schiotz tonometer measurements to mm of Hg. Normal mean (+/- SD) canine readings with the Schiotz tonometer and the 5.5-g weight was 4.9 +/- 1.5 tonometer scale units (range, 2 to 11; 95% confidence interval, 1.9 to 7.9).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

9.
Evaluation of two applanation tonometers in horses   总被引:1,自引:0,他引:1  
Comparisons were made of measurements obtained in horses, using 2 applanation tonometers in vivo and in vitro. In vitro comparisons indicated that although neither instrument accurately recorded intraocular pressure (IOP), compared with manometric measurements, results of both instruments indicated linear digression from manometric IOP values that could readily be corrected, thereby accurately estimating IOP in horses. For tonometer 1 (MacKay-Marg), calculated actual IOP = 1.48 - 0.9 mm of Hg; and for tonometer 2 (Tono-Pen), calculated actual IOP = 1.38 + 2.3 mm of Hg. The coefficients of determination (r2) values were markedly high (0.99 for both equations). In vivo comparisons in clinically normal horses did not reveal significant differences in measured IOP between the 2 instruments, and IOP was not altered from baseline after auriculopalpebral nerve block. Mean (+/- SD) IOP in clinically normal horses was 23.5 +/- 6.10 mm of Hg and 23.3 +/- 6.89 mm of Hg, for tonometers 1 and 2, respectively.  相似文献   

10.
ObjectiveTo evaluate the agreement between invasive blood pressure (IBP) and Doppler ultrasound blood pressure (DUBP) using three cuff positions and oscillometric blood pressure (OBP) in anesthetized dogs.Study designProspective study.AnimalsNine adult dogs weighing 14.5–29.5 kg.MethodsThe cuff was placed above and below the tarsus, and above the carpus with the DUBP and above the carpus with the OBP monitor. Based on IBP recorded via a dorsal pedal artery catheter, conditions of low, normal, and high systolic arterial pressures [SAP (mmHg) <90, between 90 and 140, and >140, respectively] were induced by changes in isoflurane concentrations and/or dopamine administration. Mean biases ± 2 SD (limits of agreement) were determined.ResultsAt high blood pressures, regardless of cuff position, SAP determinations with the DUBP underestimated invasive SAP values by more than 20 mmHg in most instances. With the DUBP, cuff placement above the tarsus yielded better agreement with invasive SAP during low blood pressures (0.2 ± 16 mmHg). The OBP underestimated SAP during high blood pressures (?42 ± 42 mmHg) and yielded better agreement with IBP for mean (MAP) and diastolic (DAP) arterial pressure measurements [overall bias: 2 ± 15 mmHg (MAP) and 0.2 ± 16 mmHg (DAP)].ConclusionsAgreement of SAP determinations with the DUBP is poor at SAP > 140 mmHg, regardless of cuff placement. Measurement error of the DUBP with the cuff placed above the tarsus is clinically acceptable during low blood pressures. Agreement of MAP and DAP measurements with this OBP monitor compared with IBP was clinically acceptable over a wide pressure range.Clinical relevanceWith the DUBP device, placing the cuff above the tarsus allows reasonable agreement with IBP obtained via dorsal pedal artery catheterization. Only MAP and DAP provide reasonable estimates of direct blood pressure with the OBP monitor evaluated.  相似文献   

11.
OBJECTIVE: To determine effects of the topically applied calcium-channel blocker flunarizine on intraocular pressure (IOP) in clinically normal dogs. ANIMALS: 20 dogs. PROCEDURES: Baseline diurnal IOPs were determined by use of a rebound tonometer on 2 consecutive days. Subsequently, 1 randomly chosen eye of each dog was treated topically twice daily for 5 days with 0.5% flunarizine. During this treatment period, diurnal IOPs were measured. In addition, pupillary diameter and mean arterial blood pressure (MAP) were evaluated. Serum flunarizine concentrations were measured on treatment day 5. Intraday fluctuation of IOP was analyzed by use of an ANOVA for repeated measures and a trend test. Changes in IOP from baseline values were assessed and compared with IOPs for the days of treatment. Values were also compared between treated and untreated eyes. RESULTS: A significant intraday fluctuation in baseline IOP was detected, which was highest in the morning (mean +/- SE, 15.8 +/- 0.63 mm Hg) and lowest at night (12.9 +/- 0.61 mm Hg). After 2 days of treatment, there was a significant decrease in IOP from baseline values in treated (0.93 +/- 0.35 mm Hg) and untreated (0.95 +/- 0.34 mm Hg) eyes. There was no significant treatment effect on pupillary diameter or MAP. Flunarizine was detected in serum samples of all dogs (mean +/- SD, 3.89 +/- 6.36 microg/L). CONCLUSIONS AND CLINICAL RELEVANCE: Topically applied flunarizine decreased IOP in dogs after 2 days of twice-daily application. This calcium-channel blocker could be effective in the treatment of dogs with glaucoma.  相似文献   

12.
This study was performed to determine the cardiovascular responses to isoflurane in euthyroid and hypothyroid dogs. Four healthy mixed-breed dogs were studied prior to thyroidectomy (PRE), 6 months after thyroidectomy (HYP), and after 2 months of oral supplementation with 1-thyroxine (SUP). Heart rate (HR), cardiac output (), stroke volume (SV), systolic, diastolic, mean arterial blood pressure (SAP, DAP, MAP), and total peripheral resistance (TPR) were determined in awake dogs and in the same dogs when end-tidal isoflurane concentrations were 1.28%, 1.92%, and 2.56%. Ventilation was controlled in anesthetized dogs and Paco2 maintained between 38 to 42 mm Hg. Isoflurane caused significant ( P <.05) dose-dependent reduction in , SV, SAP, DAP, and MAP in the PRE, HYP, and SUP dogs. Cardiac output was lower in the HYP dogs than in the PRE or SUP dogs during awake measurement. TPR was increased in the awake HYP dogs compared with the PRE or SUP dogs. During anesthesia, HYP dogs tended to have lower , SV, SAP, and MAP than the PRE or SUP groups, but the only significant reduction was SAP during 1.5 MAC. The cardiovascular responses to isoflurane in hypothyroid dogs are similar to euthyroid animals with a dose-dependent depression in , SV, and arterial pressure.  相似文献   

13.
OBJECTIVE: To evaluate the use of a portocaval venograft without an ameroid constrictor in the surgical management of intrahepatic portosystemic shunts (PSS). STUDY DESIGN: Prospective clinical study. ANIMALS: Seven dogs with intrahepatic PSS. METHODS: Portal pressure was measured after temporary suture occlusion of the intrahepatic PSS. In dogs with an increase in portal pressure > or =8 mm Hg or signs of portal hypertension, a single extrahepatic portocaval shunt was created using a jugular vein. Clinical outcome and complications were recorded. RESULTS: The mean (+/-SD) portal pressure increased from 5.9+/-1.6 to 17.9+/-4.1 mm Hg with PSS occlusion. There were no intraoperative complications and, after creation of the portocaval shunt, the intrahepatic PSS could be completely ligated in all dogs. The final portal pressure was 9.6+/-1.9 mm Hg. Complications developed during postoperative hospitalization in 5 dogs and included incisional discharge (4 dogs), ascites (3), ventricular premature contractions (2), and melena, bloody diarrhea, neurologic signs, coagulopathy, and aspiration pneumonia (each in 1 dog). Six dogs died or were euthanatized with clinical signs related to depression, inappetance, abdominal pain, vomiting, melena, and abdominal distention, with a median survival of 82 days (range, 20-990 days). One dog was clinically normal at 33 months after surgery. CONCLUSIONS: Clinical signs observed in 6 dogs after surgery were consistent with portal hypertension. Use of a portocaval venograft without an ameroid constrictor may reduce the likelihood of hepatic vascular development, thereby increasing the risk of life-threatening portal hypertension should the venograft suddenly occlude. CLINICAL RELEVANCE: Use of a portocaval venograft without an ameroid constrictor to control portal hypertension after ligation of an intrahepatic PSS cannot be recommended.  相似文献   

14.
Left ventricular hypertrophy signals a poor prognosis in hypertensive humans. Cardiac disease is common in cats with systemic hypertension. The aims of this study were to characterize the echocardiographic findings of cats with systemic hypertension and to determine if reducing the degree of hypertension is associated with resolution of cardiac hypertrophy. Echocardiographic examinations were performed on 19 cats with naturally occurring systemic hypertension. Fourteen of these cats were subsequently studied after a minimum of 3 months of treatment with the antihypertensive agent amlodipine. Hypertensive cats had a significantly thicker interventricular septum in both systole and diastole, thicker left ventricular free wall in both systole and diastole, and larger left atrium compared to the published normal values and 74% (14/19) of the cats met criteria for left ventricular hypertrophy (diastolic septal or free-wall thickness > 0.60 cm). Systolic blood pressure was lower after treatment (217 +/- 25 mm Hg, range: 180-275 mm Hg; and 142 +/- 27 mm Hg, range: 90-200 mm Hg). No difference was found in any of the echocardiographic measurements between the untreated and treated cats, although more cats had ventricular hypertrophy before treatment (11/14) than after initiating amlodipine (6/14; P = .006). Ventricular hypertrophy is common in hypertensive cats and may resolve after the initiation of amlodipine.  相似文献   

15.
Systemic hypertension is hypothesized to cause renal injury to dogs. This study was performed on dogs with surgically induced renal failure to determine whether hypertension was associated with altered renal function or morphology. Mean arterial pressure (MAP), heart rate (HR), systolic arterial pressure (SAP), and diastolic arterial pressure (DAP) were measured before and after surgery. Glomerular filtration rate (GFR) and urine protein:creatinine ratios (UPC) were measured at 1, 12, 24, 36, and 56-69 weeks after surgery, and renal histology was evaluated terminally. The mean of weekly MAP, SAP, and DAP measurements for each dog over the 1st 26 weeks was used to rank dogs on the basis of MAP, SAP, or DAP values. A statistically significant association was found between systemic arterial pressure ranking and ranked measures of adverse renal responses. When dogs were divided into higher pressure and lower pressure groups on the basis of SAP, group 1 (higher pressure, n = 9) compared with group 2 (lower pressure, n = 10) had significantly lower GFR values at 36 and 56-69 weeks; higher UPC values at 12 and 56-69 weeks; and higher kidney lesion scores for mesangial matrix, tubule damage, and fibrosis. When dogs were divided on MAP and DAP values, group 1 compared with group 2 had significantly lower GFR values at 12, 24, 36, and 56-69 weeks; higher UPC values at 12 and 56-69 weeks; and higher kidney lesion scores for mesangial matrix, tubule damage, fibrosis, and cell infiltrate. These results demonstrate an association between increased systemic arterial pressure and renal injury. Results from this study might apply to dogs with some types of naturally occurring renal failure.  相似文献   

16.
Discrete subvalvular aortic stenosis with peak systolic pressure gradients of more than 60 mm Hg was treated by closed transventricular dilation in six young dogs. Peak systolic pressure gradients were measured by direct catheterization before surgery, immediately after dilation, and 3 months after surgery. Maximum instantaneous pressure gradients were measured by continuous wave Doppler echocardiography before surgery and 6 weeks to 9 months after surgery. All dogs survived the procedure, and two dogs were clinically normal after 9 and 14 months. Two dogs died at week 6 and month 7. One dog was receiving medication for pulmonary edema 15 months after surgery. One dog underwent open resection of the subvalvular ring at month 3, and was clinically normal 6 months after the second procedure. Complications included intraoperative ventricular fibrillation in one dog, and mild postoperative aortic insufficiency in one dog. Closed transventricular dilation resulted in an immediate 83% decrease in the peak systolic pressure gradient from a preoperative mean of 97 +/- 22 mm Hg to a mean of 14 +/- 15 mm Hg. However, systolic pressure gradients measured by direct catheterization at month 3 (77 +/- 26 mm Hg), and by Doppler echocardiography at week 6 to month 9 (85 +/- 32 mm Hg) were not significantly different from preoperative values, which suggested recurrence of the aortic stenosis. Closed transventricular dilation should not be considered a definitive treatment for discrete subvalvular aortic stenosis in dogs, but may be useful in young dogs with critical aortic stenosis as a bridge to more definitive surgery.  相似文献   

17.
BACKGROUND: Systemic hypertension is likely underdiagnosed in veterinary medicine because systemic blood pressure is rarely measured. Systemic blood pressure can theoretically be estimated by echocardiography. According to the modified Bernoulli equation (PG = 4v(2)), mitral regurgitation (MR) velocity should approximate systolic left ventricular pressure (sLVP), and therefore systolic systemic blood pressure (sSBP) in the presence of a normal left atrial pressure (LAP) and the absence of aortic stenosis. The aim of this study was to evaluate the use of echocardiography to estimate sSBP by means of the Bernoulli equation. HYPOTHESIS: Systemic blood pressure can be estimated by echocardiography. ANIMAL: Seventeen dogs with mild MR. No dogs had aortic or subaortic stenosis, and all had MR with a clear continuous-wave Doppler signal and a left atrial to aorta ratio of < or = 1.6. METHODS: Five simultaneous, blinded continuous-wave measurements of maximum MR velocity (Vmax) and indirect sSBP measurements (by Park's Doppler) were obtained for each dog. Pressure gradient was calculated from Vmax by means of the Bernoulli equation, averaged, and added to an assumed LAP of 8 mm Hg to calculate sLVP. RESULTS: Calculated sLVP was significantly correlated with indirectly measured sSBP within a range of 121 to 218 mm Hg (P = .0002, r = .78). Mean +/- SD bias was 0.1 +/- 15.3 mm Hg with limits of agreement of -29.9 to 30.1 mm Hg. CONCLUSION: Despite the significant correlation, the wide limits of agreement between the methods hinder the clinical utility of echocardiographic estimation of blood pressure.  相似文献   

18.
OBJECTIVE: To determine norepinephrine (NE) kinetics in dogs with experimentally induced renal vascular hypertension. ANIMALS: 4 mixed-breed dogs. PROCEDURE: The study comprised a control and hypertensive period. The hypertensive period followed induction of renal vascular hypertension achieved by surgical placement of clips on both renal arteries to reduce diameter by approximately 80%. Arterial blood pressure, renal clearance, and NE kinetics were measured during each period while dogs were receiving a low-sodium diet. Measurements of NE kinetics and renal clearance during the hypertensive period were made 5 days after induction of hypertension. RESULTS: Five days after induction of hypertension, arterial blood pressure increased by 15 to 20 mm Hg. Mean (+/- SEM) plasma NE concentration and NE spillover rate increased significantly from 151.5+/-14.1 pg/ml and 8.03+/-0.62 ng/kg/min, respectively, during the control period to 631.4+/-30.5 pg/ml and 54.0+/-5.2 ng/kg/min, respectively, during the hypertensive period. Norepinephrine clearance rate also increased (54.0+/-2.4 vs. 86.0+/-9.3 ml/kg/min). Positive associations between mean arterial pressure (MAP) and NE concentration and spillover rate were detected. However, MAP and NE clearance rate were not associated. CONCLUSIONS AND CLINICAL RELEVANCE: Increased blood pressure during the hypertensive period was likely attributable to increased NE spillover rate, which resulted in a significant increase in plasma NE concentration. Analysis of these results suggests that central sympathetic outflow was increased and may be responsible for the pathogenesis of high blood pressure during the acute phase of renal vascular hypertension in dogs.  相似文献   

19.
Evaluation of two applanation tonometers in cats.   总被引:2,自引:0,他引:2  
Comparisons of the MacKay-Marg and Tono-Pen applanation tonometers in open and closed in vitro systems were made for the eyes of cats. Both instruments significantly underestimated intraocular pressure (IOP) vs direct manometry (P less than 0.001), but in readily predictable manner, with high coefficients of determination (r2 = 0.99). For tonometer 1 (MacKay-Marg), calculated actual IOP = 1.36 x (MacKay-Marg measurement) - 1.67 mm of Hg; and for tonometer 2 (Tono-Pen), calculated actual IOP = 1.37 x (Tono-Pen measurement) + 0.8 mm of HG, using measurements from 11 enucleated eyes. In vivo comparisons were initially made in 81 clinically normal eyes (n = 41 cats) by applying the Tono-Pen first followed by the MacKay-Marg. Compared with the MacKay-Marg, the Tono-Pen significantly (P less than 0.001) underestimated IOP in these cats. When the order of tonometer applanation was subsequently reversed in 73 clinically normal eyes (n = 37 cats) the Tono-Pen again significantly (P less than 0.001) underestimated IOP, compared with the MacKay-Marg. Alterations in tonometer order did not result in significant differences in measured IOP for the MacKay-Marg when compared with itself, but Tono-Pen measurements were significantly (P less than 0.05) less when its use followed, rather than preceded, that of the MacKay-Marg. Mean (+/- SD) IOP in clinically normal cats when each tonometer was used first was 22.6 +/- 4.0 mm of Hg (range, 14 to 32 mm of Hg) for the MacKay-Marg and 19.7 +/- 5.6 mm of Hg (9 to 31 mm of Hg) for the Tono-Pen.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

20.
Seventeen clinically normal adult English Cocker Spaniels from a kennel population with a history of cardiomyopathy were assessed, using M-mode echocardiography, to establish reference values for left ventricular (LV) dimensions for this breed of dog. Echocardiographic measurements were compared with postmortem measurements in 10 of 17 dogs. The LV weight calculated from the echocardiographic measurements correlated significantly with LV weight at postmortem (P less than 0.05). Echocardiographic measurements of end diastolic and end systolic diameters for the 17 dogs correlated significantly with body surface area (P less than 0.01). Measurements of the interventricular septum were in close agreement with values in clinically normal dogs and were significantly correlated with postmortem measurements (r = 0.94, P less than 0.01). However, 76% of the measurements for LV caudal wall thickness in this group of dogs were above the normal range. Calculation of fractional shortening values identified a group of 5 dogs with reduced fractional shortening (mean +/- SD, 20.97 +/- 3.66%), which indicates that a depression in contractility may be present in some apparently healthy dogs of this kennel population. The remaining 12 dogs had fractional shortening values of mean +/- SD, 34.26 +/- 4.54%.  相似文献   