The aims of this study were to determine if accurate diagnosis of congenital portosystemic shunt was possible using two dimensional, grey-scale ultrasonography, duplex-Doppler, and color-flow Doppler ultrasonography in combination, and to determine if dogs with congenital portosystemic shunts have increased or variable mean portal blood flow velocity. Eighty-two dogs with clinical and/or clinicopathologic signs compatible with portosystemic shunting were examined prospectively. Diagnosis of congenital portosystemic shunt was subsequently confirmed in 38 of these dogs using operative mesenteric portography: 14(37%) dogs had an intrahepatic shunt and 24(63%) had an extrahepatic shunt. Ultrasonography had a sensitivity of 95%, specificity of 98%, and accuracy of 94%. Ultrasonographic signs in dogs with congenital portosystemic shunts included small liver, reduced visibility of intrahepatic portal vessels, and anomalous blood vessel draining into the caudal vena cava. Correct determination of intra - versus extrahepatic shunt was made ultrasonographically in 35/38 (92%) dogs. Increased and/or variable portal blood flow velocity was present in 21/30 (70%) dogs with congenital portosystemic shunts. In one dog with an intrahepatic shunt the ultrasonographic diagnosis was based partly on finding increased mean portal blood flow velocity because the shunting vessel was not visible. Detection of the shunting vessel and placement of duplex-Doppler sample volumes were facilitated by use of color-flow Doppler. Two-dimensional, grey-scale ultrasonography alone is sufficient to detect most intrahepatic and extrahepatic shunts; sensitivity is increased by additional use of duplex-Doppler and color-flow Doppler. Increased and/or variable portal blood flow velocity occurs in the majority of dogs with congenital portosystemic shunts.  相似文献   

2.
Twenty-two dogs with congenital single portosystemic shunts were treated by partial or complete ligation of the shunts. Intraoperative portal pressures before and after shunt ligation, and central venous pressures measured after 3 minutes of temporary shunt occlusion, were evaluated prospectively. Portal pressures after ligation, increases in portal pressure above baseline values, and decreases in central venous pressure during temporary occlusion were significantly greater in dogs that underwent partial portosystemic shunt ligation and in dogs that developed postoperative complications. Absence of arborizing intrahepatic vasculature in intraoperative mesenteric portograms did not indicate whether partial or complete shunt attenuation could be performed safely, but it was correlated with greater occurrence of post-operative complications.  相似文献   

3.
Transvenous retrograde portography for identification and characterization of portosystemic shunts in dogs A method for transvenous retrograde portography (TRP) in dogs suspected to have a portosystemic shunt (PSS) and results in 20 dogs are described. For TRP, dogs were anesthetized and positioned in left lateral recumbency A dual-lumen balloon-tipped catheter was inserted into the right jugular vein and advanced into the azygos vein. The balloon was inflated to occlude the azygos vein, and contrast material was injected during fluoroscopic evaluation. The catheter was then positioned in the caudal vena cava just cranial to the diaphragm. The balloon was again inflated to occlude the vena cava, and contrast material was again injected. Once a shunt was identified, selective catheterization was attempted with a guide wire and angled catheter. A PSS was identified in 18 of the 20 dogs. In 10 of the 18, the shunt vessel could be selectively catheterized, allowing measurement of portal pressures while the shunt was occluded with the balloon. In 1 dog, results of TRP were normal, but subsequent exploratory celiotomy revealed a single extrahepatic PSS, which was surgically attenuated. The other dog in which results of TRP were normal did not have a macroscopic PSS. In dogs suspected to have a PSS, TRP may be a useful adjunctive diagnostic test that is less invasive than operative mesenteric vein portography and allows measurement of portal pressures before and after temporary shunt occlusion.  相似文献   

4.
OBJECTIVE: To determine portal hemodynamic changes associated with surgical shunt ligation and establish ultrasonographic criteria for determining the optimal degree of shunt narrowing and predicting outcome. DESIGN: Case series. ANIMALS: 17 dogs, each with a single congenital extrahepatic portosystemic shunt. PROCEDURE: Pre- and postligation flow velocities and flow directions were determined by Doppler ultrasonography intraoperatively in the shunt and in the portal vein cranial and caudal to the shunt origin. Outcome was evaluated 1 month after surgery by measuring blood ammonia concentration and performing abdominal ultrasonography. RESULTS: Hepatofugal flow was detected in 9 of 17 dogs before shunt attenuation in the portal segment that was between the shunt origin and the entering point of the gastroduodenal vein. If hepatofugal flow became hepatopetal after shunt ligation, hyperammonemia resolved. Hepatofugal portal flow was caused by blood that flowed from the gastroduodenal vein toward the shunt. Shunt attenuation converted hepatofugal flow to hepatopetal in the shunt in 12 of 17 dogs. Chronic portal hypertension developed or perioperative death occurred when the portal congestion index caudal to the shunt origin increased by > 3.6 times. CONCLUSIONS AND CLINICAL RELEVANCE: After hepatopetal flow in the cranial portal vein and the shunt is established, further shunt narrowing is contraindicated. Increase of the portal congestion index caudal to the shunt > 3.5 times should be avoided. Poor outcome because of severe hypoplasia of the portal branches can be expected if the flow direction remains hepatofugal after shunt occlusion cranial to the shunt origin.  相似文献   

5.
The investigators studied the hepatic angiographic technics used in human medicine with respect to their applicability for the investigation of circulatory liver diseases in the dog and cat. The technics were performed in 11 normal dogs and 2 normal cats, and the normal radiographic anatomy of the hepatic portal system and its tributaries was described. The potential indications for the angiographic technics were defined and their respective advantages and disadvantages discussed. Splenoportography was a valuable method for outlining the intrahepatic portal vein branches and for percutaneous prehepatic portal vein pressure determination. Percutaneous transhepatic portography was more difficult to perform, but it provided better detail of the intrahepatic portal veins than splenoportography. Transjugular transhepatic portography was the most versatile but also the most cumbersome of all technics tested. Percutaneous kinetic hepatography proved impractical in dogs and cats. The mesenteric tributaries to the hepatic portal system were best outlined by cranial mesenteric arterial portography or by operative mesenteric venous portography. Operative mesenteric venous portography, in contrast to cranial mesenteric arterial portography, was also useful for prehe-patic portal vein pressure determination. Free and wedged hepatic venography provided an opportunity for the functional and morphologic investigation of the hepatic sinusoid circula-tion.  相似文献   

6.
Ultrasonographic diagnosis of congenital portosystemic shunt in 14 cats   总被引:2,自引:0,他引:2  
Twenty-four cats with clinical and, or, clinico-pathological signs compatible with portosystemic shunting were examined prospectively using two-dimensional grey-scale, duplex and colourflow Doppler ultrasonography. Diagnosis of congenital portosystemic shunt was subsequently confirmed in 14 cats using operative mesenteric portography and surgery. Of the 14 affected cats, nine were purebred; eight were male and six female. The mean age at the time of diagnosis was nine months (range four to 27 months). Ultrasonographic evidence of a small liver was present in seven cats (50 per cent); visibility of intrahepatic portal vessels was reduced in three (21 per cent). An anomalous blood vessel was identified ultrasonographically in each cat; in 10 cats (71 per cent) the vessel was observed to originate from the portal vein and drain into the caudal vena cava. Abnormally variable portal blood flow waspresent in eight of the 10 cats in which it was measured. At surgery, six shunts were intrahepatic and eight extrahepatic; the ultrasonographic diagnosis of intra- versus extra-hepatic shunt was correct in 13 cats (93 per cent). No anomalous blood vessels or abnormalities affecting the portal vein were detected ultrasonographically in any of the 10 cats that did not have congenital portosystemic shunting. Hence, the accuracy of ultrasonography for diagnosis of congenital portosystemic shunting in this series was 100 per cent.  相似文献   

7.
Measurement of portal blood flow in dogs using duplex-Doppler ultrasonography has potential clinical utility for diagnosis of cirrhosis and portosystemic shunts. Three methods for calculating portal blood flow were compared to identify a consistent method with minimal potential for intraoperator variation. Sixteen unsedated, normal beagles had their mean portal blood flow velocity determined using three methods: method 1 used a small Doppler sample volume positioned over the center of the portal vein and manual selection of data points on the resulting velocity spectra, followed by arithmetic correction of the calculated maximum velocity to mean velocity using the factor 0.57; method 2 used a small centrally-located Doppler sample volume and computed maximum flow determination, again corrected using the factor 0.57; method 3 used a large Doppler sample volume that overlapped the walls of the portal vein followed by computed mean blood flow velocity determination. The calculated mean (SD) portal blood flow velocity was 15.8 (1.8), 15.1 (1.4), and 14.7 (2.5) cm/s using methods 1–3, respectively. There was no significant difference between the results of the three methods; however, method 3 (uniform insonation) was easier to use and produced a higher amplitude Doppler signal and therefore represents a useful alternative to the peak flow methods.  相似文献   

8.
A 5-month-old alpaca cria was examined for chronic poor growth and repeated episodes of diarrhea. Examination of feces for parasites yielded negative results. Serum bile acid and blood ammonia concentrations were high. Subsequent examination by ultrasonography, percutaneous splenic portography, and colonic scintigraphy did not reveal evidence of a portosystemic vascular anomaly. Exploratory celiotomy with mesenteric vein portography revealed a colonic vein shunt in the caudal portion of the abdomen from the caudal vena cava to the portal vein. The shunt vessel was ligated without incident. Following surgery, the cria began to gain weight and was more alert. Eighteen months after surgery, the cria was doing well, although it had loose feces and was slightly small for its age. Portosystemic shunts are rare in cattle and horses but should be considered in alpacas with chronic poor growth when parasitism has been ruled out.  相似文献   

9.
Objectives : To compare the serum level of hyaluronic acid in dogs with congenital portosystemic shunt with that in healthy dogs and to investigate the perioperative change in serum hyaluronic acid following shunt attenuation. Methods : Blood samples were obtained from 29 congenital portosystemic shunt dogs before the operation, and 2 and 4 weeks after the operation from 17 and 7 dogs, respectively. The serum hyaluronic acid level of these dogs was measured and compared with that of 10 healthy beagles. Results : The median preoperative hyaluronic acid level in dogs with congenital portosystemic shunt was significantly elevated compared with that in healthy dogs. Furthermore, the median postoperative hyaluronic acid level significantly decreased compared with the median preoperative levels in congenital portosystemic shunt dogs. Clinical Significance : In the case of dogs with congenital portosystemic shunt, the reduction of intrahepatic portal blood flow might lower the clearance rate of hyaluronic acid in hepatic sinusoidal endothelial cells, so hyaluronic acid clearance could be improved by attenuation of a shunt vessel. Hence, serum hyaluronic acid levels might be useful to evaluate liver function and also have the potential to evaluate successful attenuation of a shunt vessel in dogs with congenital portosystemic shunt. Further investigations are required to clarify whether serum hyaluronic acid offers significant benefits over existing markers such as serum bile acid or ammonia concentrations.  相似文献   

10.
OBJECTIVE: To determine whether hepatic portal vascularity, as assessed by intraoperative mesenteric portovenography (IMP), is related to outcome in dogs undergoing attenuation of single congenital portosystemic shunts (CPSSs). DESIGN: Retrospective case series. ANIMALS: 45 dogs, each with a single CPSS, in which IMP was performed before and after temporary complete occlusion of the shunting vessel and that underwent complete (17 dogs) or partial (28 dogs) CPSS attenuation (surgery 1). PROCEDURES: Medical records were reviewed for signalment, clinical history, and bile acids stimulation test results. Intrahepatic portal vessel (IPV) opacification in pre- and postocclusion portovenograms was graded to determine whether the degree of opacification was correlated with the degree of shunt attenuation, clinical or biochemical factors, or long-term clinical outcome. In 17 of 28 dogs that had partial CPSS attenuation, these procedures were subsequently repeated (surgery 2) to achieve complete (14 dogs) or further partial (3 dogs) CPSS attenuation. RESULTS: Compared with preattenuation findings, IPV opacification increased significantly after partial or complete CPSS attenuation. The degree of IPV opacification before and after CPSS occlusion (surgery 1) was greater in dogs that tolerated complete versus partial CPSS attenuation and was correlated positively with age. The degree of IPV opacification following CPSS occlusion (surgery 1) was maximal in all dogs without encephalopathy and was correlated negatively with follow-up preprandial serum bile acids concentrations and positively with clinical improvement. CONCLUSIONS AND CLINICAL RELEVANCE: Data suggest that IMP can be used to assess changes in IPV blood flow and help predict outcome following attenuation of single CPSSs in dogs.  相似文献   

11.
Examination of a 2-month-old male golden retriever presented to the hospital revealed malnutrition, ascites, cardiac murmur and hyperammonemia. Identification of subaortic stenosis and hepatic arteriovenous fistula was made through ultrasonography and angiocardiography. In addition, intrasurgical mesenteric portography showed an intrahepatic portosystemic shunt. The dog did not show portal hypertension and secondary multiple extrahepatic portosystemic shunts. Surgical correction was attempted after medical treatment. The hepatic artery branch which was connected to the hepatic arteriovenous fistula was separated, and completely ligated using silk ligature. However, the separation of the intrahepatic shunt blood vessel was unsuccessful and the dog died 15 hr postoperatively.  相似文献   

12.
Surgical Management of Multiple Congenital Intrahepatic Shunts in Two Dogs   总被引:1,自引:0,他引:1  
Objective —To present details of an unusual type of portosystemic shunt and its surgical management in two dogs.
Animals —Two young dogs that had a tentative diagnosis of a portosystemic shunt on the basis of clinical signs and serum biochemical abnormalities. Abdominal ultrasonography and contrast portography demonstrated multiple intrahepatic shunts. In both cases, the multiple shunts arose from a single branch of the portal vein.
Outcome—It was possible to locate and attenuate flow through the shunts via a transportal venotomy under conditions of hepatic vascular occlusion. Clinical and biochemical abnormalities resolved after surgery in both dogs. Postoperative sonography revealed complete obliteration of the shunt plexus in one of the dogs.  相似文献   

13.
An overview of clinical, laboratory, and diagnostic imaging features of congenital porto-systemic shunt (PSS) in dogs and cats is presented through the analysis of recent literature, and personal case log. Particular emphasis is given to diagnostic accuracy of ultrasonographic examination of PSS in the evaluation of shunt vessel anatomy, and of ancillary findings such as abnormalities of portal vein flow, portal branches, and liver size. Operative mesenteric portography to obtain information on PSS morphology and position, and quantitative hepatic scintigraphy, which allows the calculation of shunt fractions, are also described. Limitations for each diagnostic imaging technique are given.  相似文献   

14.
A retrospective study of the use of intraoperative mesenteric portovenography (IOMP) in the surgical management of congenital portosystemic shunts in 100 dogs and cats was performed. Each portovenogram was scored using a subjective visual analogue scale (VAS) and was assessed for the presence of portal atresia or hypoplasia. VAS scores and portal hypoplasia assessments were obtained for portovenogram images obtained for each animal both before shunt manipulation (preligation) and following the temporary, complete ligation of the vessel (postligation). In each patient, surgical records were reviewed to ascertain the degree of shunt attenuation that was achieved at surgery. Hepatic portal vasculature was significantly different on postligation compared with preligation IOMP. Sixty-two percent of animals had apparent portal hypoplasia or atresia on their preligation IOMP. The majority of these (81%) had an improvement in portal vasculature on postligation IOMP. It was concluded that both preligation and postligation IOMP provided valuable information regarding the morphology of congenital portosystemic shunts. An accurate assessment of an animal's portal vasculature could only be made following the interpretation of a postligation portovenogram, and these findings significantly influenced the surgical management of the patient. Although individuals with high postligation VAS scores were more likely to achieve full shunt attenuation at surgery, there was no quantifiable relationship between IOMP findings and the degree of shunt attenuation achieved.  相似文献   

15.
OBJECTIVE: To evaluate the effect of intraoperative attenuation of congenital extrahepatic portosystemic shunts (CEPSSs) during cellophane banding procedures in dogs. STUDY DESIGN: Retrospective case series and prospective study. ANIMALS: 18 cases evaluated retrospectively and 14 dogs evaluated prospectively. PROCEDURES: Gradual occlusion of CEPSSs was performed via cellophane banding. Shunts were occluded to a diameter < 3.0 mm during surgery in dogs prospectively enrolled in the partial attenuation group, whereas the shunt was not attenuated during surgery in dogs prospectively enrolled in the no-attenuation group or in dogs that had previously undergone surgery and were retrospectively evaluated. Postprandial serum bile acids (PPSBA) concentrations were measured before surgery and at various time points after surgery. RESULTS: Mean +/- SD PPSBA concentrations were 26.8 +/- 24.5 micromol/L at < 2.25 months after surgery (n = 16 dogs), 22.1 +/- 14.0 micromol/L from 2.25 to 6 months after surgery (12 dogs), and 34.9 +/- 32.5 micromol/L at > 6 months after surgery (22 dogs). In the prospectively enrolled dogs, mean PPSBA concentrations increased over time in dogs in the partial attenuation group, but not in dogs in the no-attenuation group. CONCLUSIONS AND CLINICAL RELEVANCE: Cellophane banding may be used to occlude larger CEPSSs and may decrease the need for intraoperative monitoring of portal vein blood pressure. The technique may facilitate minimally invasive treatment of CEPSSs in dogs. Intraoperative attenuation of CEPSSs to a diameter < 3.0 mm is not necessary and may result in a less favorable outcome.  相似文献   

16.
OBJECTIVE:To evaluate the use of a portocaval venograft and ameroid constrictor in the surgical management of intrahepatic portosystemic shunts (PSS). STUDY DESIGN: Prospective, clinical study. Animal Population: Ten client-owned dogs with intrahepatic PSS. METHODS: Portal pressure was measured after temporary suture occlusion of the intrahepatic PSS. In dogs with an increase in portal pressure greater than 8 mm Hg, a single extrahepatic portocaval shunt was created using a jugular vein. An ameroid ring was placed around the venograft and the intrahepatic PSS was attenuated. Transcolonic pertechnetate scintigraphy was performed before surgery, 5 days after surgery, and 8 to 10 weeks after surgery. Dogs with continued portosystemic shunting were evaluated further by laparotomy or portography. Clinical outcome and complications were recorded. RESULTS: Mean (+/- SD) portal pressure increased from 6 +/- 3 to 19 +/- 6 mm Hg with PSS occlusion; in all 10 dogs, the increase in portal pressure was greater than 8 mm Hg. There were no intraoperative complications, and, after creation of the portocaval shunt, the intrahepatic PSS could be completely ligated in 8 of 10 dogs. The final portal pressure was 9 +/- 4 mm Hg. Postoperative complications included coagulopathy and death (1 dog), ascites (3 dogs), and incisional discharge (3 dogs). Five of 8 dogs had continued portosystemic shunting at 8 to 10 weeks after surgery. Multiple extrahepatic PSS were demonstrated in 4 of these dogs. Clinical outcome was excellent in all 9 surviving dogs. CONCLUSIONS AND CLINICAL SIGNIFICANCE: The surgical technique resulted in a high incidence of multiple extrahepatic PSS. Short-term clinical results were promising, but long-term outcome must be evaluated further.  相似文献   

17.
Congenital portosystemic shunts (PPS) are abnormal vascular communications that allow blood from the intestine to bypass the liver, and are classified as intrahepatic or extrahepatic. Clinical signs are generally related to the nervous, gastrointestinal or urinary systems, and are often vague. In addition, changes present on routine blood analysis are often mild and non-specific. For this reason, alternative tests are required for a diagnosis. Diagnostic tests include serum bile-acid concentrations, ammonia tolerance test, portography, ultrasonography and/or scintigraphy. Medical therapy involves reducing absorption of encephalopathic toxins from the gastrointestinal tract and may prolong survival. Surgical therapy is aimed at attenuation of the shunting vessel and provides improved survival rates. The traditional approach has been complete or partial ligation of the shunt. More recent approaches have involved slow, progressive attenuation with ameroid constrictors or cellophane banding. Overall, prognosis following surgical therapy is good in dogs and fair in cats.  相似文献   

18.
OBJECTIVE: To evaluate the efficacy of cellophane banding of single congenital extrahepatic portosystemic shunts in dogs using transcolonic portal scintigraphy. To investigate the portal circulation of those dogs with elevated postoperative shunt fractions to determine the cause of the persistent shunting. Further, to evaluate whether presenting signs, clinical pathology findings and liver histopathology are predictive of outcome. DESIGN: Prospective study of 16 dogs presenting with single congenital extrahepatic portosystemic shunts. PROCEDURE: Dogs with single extrahepatic portosystemic shunts attenuated by cellophane banding underwent portal scintigraphy and bile acids tolerance testing pre- and post-operatively. Dogs identified with elevated shunt fractions at 10 weeks post-operatively underwent mesenteric portovenography. Qualitative hepatic histopathology from all dogs was reviewed by a veterinary pathologist and assigned a semi-quantitative score to identify any abnormalities that may predict surgical outcome. RESULTS: At 10 weeks post cellophane banding, 10 of 16 cases (63%) had normal shunt fractions, whilst six dogs (37%) had increased shunt fractions and seven dogs (44%) had increased serum bile acids. Of these dogs, mesenteric portovenography revealed incomplete closure of the shunt in three dogs (18.6%) and multiple acquired shunts in three dogs (18.6%). Liver histopathology findings were similar for all dogs, regardless of outcome. CONCLUSIONS: Cellophane banding is an efficacious method for complete gradual occlusion of single extrahepatic shunts when the shunt vessel is attenuated to < or = 3 mm. Transcolonic portal scintigraphy is a reliable method for assessment of shunt attenuation and, unlike serum bile acids, is not influenced by other causes of liver dysfunction.  相似文献   

19.
Objective— To evaluate trans-splenic portal scintigraphy (TSPS) and per-rectal portal scintigraphy (PRPS) for diagnosis of congenital portosystemic shunts (CPSS) in dogs, and compare these results with surgical findings.
Study Design— Prospective, randomized cross over clinical trial.
Animals— Dogs (n=42) with suspected CPSS.
Methods— Dogs had TSPS and PRPS 48 hours apart; quantity of radionuclide administered was recorded. Three independent, blinded reviewers evaluated each scintigraphic study for study quality, shunt presence, number, and location of shunt termination (caudal vena cava, azygos vein). All dogs had exploratory celiotomy. Negative scintigraphic findings were confirmed with intraoperative mesenteric portography. Ameroid constrictors were placed on all extrahepatic CPSS, and hepatic biopsies were obtained.
Results— TSPS was 100% sensitive and specific for diagnosis of CPSS and significantly ( P <.05) more likely than PRPS to detect shunt number and termination. Interpretation was consistent between observers, and TSPS required significantly less radionuclide than PRPS.
Conclusion— TSPS was as sensitive as PRPS for detection of shunting vessels, and consistently yielded studies of higher quality, allowing detection of shunt number and location with consistent interpretation among radiologists.
Clinical Relevance— TSPS provides information about shunt number and location, which allows improved surgical planning. Because it requires significantly less radionuclide, TSPS improves safety, allows for more comprehensive patient care, and earlier surgical intervention.  相似文献   

20.

Background

Doppler ultrasonography is an important tool for evaluating hepatic portal hemodynamics. However, no study in dogs of different body weights, in the range encountered in routine clinical veterinary practice, has been reported. It can be difficult to obtain an ideal insonation angle when evaluating the main portal vein, so evaluation of the right portal vein branch has been described in humans as an alternative. The aim of this study was to analyze, through Doppler ultrasonography, the hemodynamics in the right portal vein branch in dogs of different body weights.

Methods

Thirty normal dogs were divided in three groups by weight, in order to establish normal values for mean velocity, flow volume and portal congestion index of the right portal vein branch by means of Doppler ultrasonography.

Results

In all dogs ideal insonation angles were obtained for the right portal vein branch. The average velocity was similar in the three groups, but the portal congestion index and the flow volume differed, showing that the weight of the dog can influence these values.

Conclusion

Doppler ultrasonography for the evaluation of flow in the right branch of the portal vein could be a viable alternative, or complement, to examining the main vessel segment. This is especially so in those animals in which an ideal insonation angle for examination of the main portal vein is hard to obtain. In addition, the weight of the dog must be considered for the correct evaluation of the portal system hemodynamics, particularly for portal blood flow and the congestion index.  相似文献   