首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Spectral waveform analysis of blood flow velocity in the major arteries of six healthy, conscious immature micropigs was determined using Doppler ultrasonography. Doppler spectral tracings were recorded from the external iliac artery, femoral artery, and renal arcuate artery. Tracings were also taken from three parts of the common carotid artery and two parts of the abdominal aorta. Spectral Doppler parameters included peak systolic velocity, early diastolic velocity, peak systolic velocity-to-end diastolic velocity ratio, resistive index, and pulsatility index. In addition, the diameter of major arteries and indirect blood pressure were measured. These results from spectral Doppler analysis in major arteries may be useful as reference ranges in the future studies of vascular hemodynamics in immature micropigs.  相似文献   

2.
The purpose of this study was to qualify and quantify the femoral artery blood flow by duplex Doppler ultrasonography (DDU) in healthy dogs, before and after the administration of a combination of acepromazine maleate and buprenorphine hydrochloride (ACP-BPN). Seven healthy adult mongrel dogs and three adult beagles were used. Heart rate, arterial blood pressure and measurement of femoral artery blood flow by DDU were also recorded. The DDU measurements were: femoral artery diameter (FAD), peak systolic velocity (PSV), early retrograde (EDV) and end diastolic velocities (EnDV), mean velocity (BMV), pulsatility index (PI), flow velocity integral (FVI) and femoral blood flow (FBF). After 30 min, combination ACP-BPN was administered intramuscularly, and all the measurements were recorded again. The ACP-BPN protocol induced a significant decrease in systolic, mean, and diastolic arterial blood pressure, and heart rate. A significant increase in peak systolic velocity and integral flow velocity integral of the femoral blood were obtained. The Doppler spectra of the blood flow in the femoral artery revealed a spectral dispersion pattern after ACP-BPN administration in all the dogs. These results demonstrate that despite quantitative and qualitative changes, the overall femoral blood flow (FBF) is not significantly modified.  相似文献   

3.
The purpose of this study was to measure splanchnic blood flow during digestion in unsedated dogs by using duplex Doppler sonography. The study population consisted of 12 healthy dogs. Blood flow in the cranial mesenteric artery, the celiac artery, and the aorta was measured before a test meal and at 20, 60, and 90 minutes after eating. The following measurements were made or calculated: vessel diameter, peak systolic velocity, end diastolic velocity, mean velocity, resistive index, pulsatility index, and flow volume. There was a significant postprandial decrease in the resistive and pulsatility indices in both the cranial mesenteric (preprandial RI = 0.867, postprandial RI = 0.796, preprandial PI = 3.033, postprandial PI = 2.173) and the celiac (preprandial RI = 0.854, postprandial RI = 0.769, preprandial PI = 2.639, postprandial PI = 1.930) arteries. In both vessels the end diastolic velocity, the mean velocity, and the flow volume increased significantly postprandially. These changes occurred significantly earlier in the celiac artery than in the cranial mesenteric artery. The findings most likely correspond to postprandial splanchnic vasodilation. Doppler ultrasound provide a good methode of detecting changes in postprandial splanchnic blood flow in the dog.  相似文献   

4.
Doppler spectra of the abdominal aorta (AAo), cranial mesenteric artery (CMA), celiac artery (CA), and left renal artery (LRA) were obtained from 11 fasted, clinically healthy, conscious Beagles before and after inducing severe acute normovolemic anemia (mean±standard deviation hematocrit 16.0±0.77%). Peak systolic, end diastolic, and time-averaged mean velocities were measured. The different vessels were compared with each other. Peak systolic velocity ratio and time-averaged mean velocity ratio of splanchnic vessels to corresponding variables of the AAo were computed and compared between and within vessels during physiologic and anemic states. There was no difference between LRA and AAo, CMA or CA regarding time-averaged mean velocity, time-averaged mean velocity ratio, or end diastolic velocity during the physiological state. During the anemic state, LRA mean time-averaged mean velocity ( P ≤0.008) and mean end diastolic velocity ( P ≤0.041) were significantly lower than those of AAo, CMA, and CA. Mean time-averaged mean velocity ratio of the LRA was also significantly ( P ≤0.004) lower than the CMA and CA ratios, and significantly ( P =0.014) lower during anemic state than physiologic state of the same vessel. End diastolic and time-averaged mean velocities of the AAo, CMA, and CA increased proportionally during anemia, but there was a relatively less increase in the same variables of the LRA, suggesting less increase in blood flow. Doppler ratios allowed a noninvasive comparison between splanchnic and aortic hemodynamics. Velocity ratios might be useful for clinical detection of relative hemodynamic changes between different vessels.  相似文献   

5.
The purpose of this study was to evaluate the effects of medetomidine administration on the Doppler variables of abdominal arteries. The study population consisted of 20 healthy dogs. The haemodynamic effects of the medetomidine were defined using Doppler variables of the abdominal aorta, renal arteries, cranial mesenteric artery and celiac artery. The dogs were monitored continuously and different measurements were performed before medetomidine injection, at 10, 40 and 80 minutes after medetomidine medication and after atipamezole administration. Changes in the characteristic Doppler spectra of different vessels were more marked in the abdominal aorta, in which a greater reverse flow was found. There was a significant decrease in peak systolic velocity (PSV), end diastolic velocity (EDV), and mean velocity (MV) at ten minutes in every vessel studied and this effect persisted until atipamezole administration. Pulsatility index (PI) increased significantly in the abdominal aorta at ten minutes and persisted during the study until atipamezole administration. Resistive index (RI) did not vary significantly in any vessel. A significant decrease was found in flow volume of the abdominal aorta, the cranial mesenteric artery and the celiac artery at ten minutes, persisting until atipamezole administration. We conclude that medetomidine can be a good sedative in aiding sonographic evaluation of RI in all the abdominal vessels studied. On the other hand, the changes in other Doppler variables suggest that medetomidine administration causes significant hemodynamic differences between sedated and non-sedated dogs.  相似文献   

6.
Insonation of Circle of Willis by transcranial Doppler duplex color sonography is described in 30 healthy dogs with 15 weighing <33 lb and 15 weighing >33 lb. Imaging was via a temporal window to explore the rostral, middle, and caudal cerebral arteries on both the left and right-hand sides; and through an suboccipital window to study the basilar artery. Normal mean values of the peak systolic velocity (PSV), end diastolic velocity, mean velocity, resistance index (RI), and pulsatility index (PI) were characterized and compared with those obtained in previous studies. There was significant differences in the PSV, RI, and PI in the rostral cerebral artery between dogs weighing <33 vs. >33 lb. Mean PSV was higher in weighing over 33 lb, whereas the mean resistive index and mean PI were lower in these dogs.  相似文献   

7.
The accuracy of Doppler-derived blood flow velocity depends on the angle of incidence between the ultrasound beam and the direction of flow. In dogs with subaortic stenosis, it is known that the subcostal transducer site provides higher left ventricular ejection velocities than does the apical site. Left ventricular ejection velocities obtained from the subcostal site in healthy dogs have not been reported; accordingly, we examined healthy, random-source dogs to test the hypothesis that aortic velocities obtained from the subcostal and apical transducer sites differ. In 38 unsedated dogs, high-pulsed repetition frequency (HPRF) and continuous-wave (CW) Doppler studies of the proximal aorta and left ventricular outflow tract were performed using two-dimensional echocardiographic guidance. The effects of Doppler modality, transducer site, and their interaction on peak aortic velocity were tested through the use of analysis of variance. P values less than 0.05 were considered to indicate significance. The mean (+/-SE) peak aortic velocities were as follows: subcostal site (HPRF) = 1.44 +/- 0.03; apical site (HPRF) = 1.39 +/- 0.03; subcostal site (CW) = 1.48 +/- 0.03; apical site (CW) = 1.39 +/- 0.03. Aortic velocities obtained from the subcostal site were significantly greater than those obtained from the cardiac apex (P = 0.0001). Lower and upper limits of 95% reference intervals for aortic velocities by method of measurement and transducer location are proposed. In a population of healthy dogs, peak aortic velocities obtained from the subcostal site exceeded those obtained from the cardiac apex but did so only to a marginal degree.  相似文献   

8.
Judith A.  Hudson  DVM  PhD  Donald F.  Buxton  DVM  PhD  Nancy R.  Cox  DVM  PhD  Susan T.  Finn-Bodner  DVM  MS  Stephen T.  Simpson  DVM  MS  James C.  Wright  DVM  PhD  Shellie S.  Wallace  DVM  MS  Alexander  Mitro  MD  PhD  DSc 《Veterinary radiology & ultrasound》1997,38(4):313-322
Doppler ultrasonography was performed on the cerebral arteries o f 19 neontal dogs.Vascular structures were identified using anatomic preparations of brains pre-injected with a radiopaque silicone rubber product and cleared using a modified tissue clearing technique. Brain sections were subsequently radiographed of examined under a steromicroscope. Color flow Doppler imagin was used to facilitate positioning of the Doppler calipers for measurement of peak systolic velocity, minimum diastolic velocity, and resistance index. Blood flow velocities in the internal carotid and middle cerebral arteries were lower when measured intransvere images than in sagittal images. The rostral cerebral arteries could be measured using either plane but values obtained from different locations or using different methods of measurement were statistically different. Blood flow velocities generally increased during the first month after birth. Arterial signals were diphasic with flow throughout diastole. Resistance indices most often were between 0.6 and 0.7 and did not exceed 0.86.  相似文献   

9.
ObjectivesThis study aimed to evaluate the effect of 8 hemodynamic conditions on blood pressure measurements taken from the carotid, femoral and dorsal pedal arteries of dogs.AnimalsSix healthy dogs.MethodsDuring isoflurane anesthesia, catheters were introduced into the carotid, femoral and dorsal pedal arteries of dogs to allow simultaneous monitoring of direct blood pressure in each artery. The dogs were submitted to 8 hemodynamic conditions induced by combining changes in heart rate (bradycardia, normocardia, tachycardia) with changes in blood pressure (hypotension, normotension, hypertension). Values obtained from each arterial catheter were compared and agreement between central (carotid) and peripheral (femoral and dorsal pedal) values were analyzed by the Bland–Altman method.ResultsDuring hypotensive conditions, systolic arterial pressure (SAP) was lower in the femoral and dorsal pedal arteries compared to the carotid artery whereas during normotensive and hypertensive conditions, SAP was higher in peripheral arteries. During hypotensive states, increases in heart rate resulted in greater bias between central and peripheral SAP whereas during normotensive states, the bias decreased as heart rate increased. Mean and diastolic arterial pressures were lower in the femoral and dorsal pedal arteries than in the carotid artery during most hemodynamic conditions.ConclusionsIn healthy anesthetized dogs, invasive blood pressure measurements in peripheral arteries may differ significantly from measurements in a central artery. The greatest differences were observed in SAP and the magnitude of differences between central and peripheral blood pressure measurements varied according to the dog's hemodynamic condition.  相似文献   

10.
Nineteen of 28 (67%) Greyhounds enrolled in the Blood Donor Program at The Veterinary Teaching Hospital, The Ohio State University (Columbus, OH), had a left basilar systolic murmur. Ten Greyhounds with murmurs and 9 without murmurs were evaluated to gain knowledge about the pathogenesis of this murmur. Echocardiograms were performed without sedation by means of a GE Vivid 7 Echocardiographic System with a continuous ECG; systolic arterial blood pressure (SABP) was measured with an Ultrasonic Doppler Flow detector model 811-B. The mean peak aortic velocity in the Greyhounds with murmurs (2.15 m/s; range, 1.8-2.2 m/s) was significantly higher than in the Greyhounds without murmurs (1.89 m/s; range, 1.6-2.0 m/s) (P < .001); there were no significant differences between groups for aortic valve or annulus diameter, fractional shortening, pulmonic velocity, SABP, hematocrit, serum protein concentration, or red blood cell counts. In this study, Greyhounds with soft, left basilar systolic murmurs had mildly (but significantly) higher mean peak aortic velocities than similar dogs without murmurs. In the dogs with murmurs (and higher velocities), we could not identify structural abnormalities, such as valvular lesions or other congenital defects. There was no inverse correlation between the systolic murmur and the higher hematocrit and red blood cell counts observed in this breed. This 1-2/6 basilar systolic murmur is common in Greyhounds, and it does not appear to be of any clinical consequence.  相似文献   

11.
Two-dimensional ultrasound was used in combination with colour-coded and pulsed Doppler sonography to study the blood flow of the testes and prostate gland in a total of 30 male dogs. After detection of the vessels by colour-coded Doppler sonography, the blood flow patterns were determined by pulsed Doppler sonography measuring and describing the systolic and diastolic peak velocity (SPV, DPV), the end-diastolic velocity, the time-averaged maximum velocity (TAMAX), the pulsatility and resistance index, as well as the ratios of the systolic peak velocity and end-diastolic velocity and of the systolic and diastolic peak velocities. The blood flow of the testicular artery was measured within the pampiniform plexus and the marginal location. The prostatic blood supply was measured in the artery of the deferential duct (cranial), the prostatic artery outside (lateral) and within the gland (subcapsular). The physiological testicular flow pattern was monophasic with a high diastolic flow. Testes with neoplastic alterations showed a significant increase of SPV and TAMAX. The epididymal vessels could not be detected. Under physiological conditions the prostatic blood flow pattern was biphasic in the cranial and lateral location and monophasic in the subcapsular location. Benign prostatic hyperplasia was characterized by a significant increase of SPV, DPV and TAMAX. The results of the present investigation demonstrate that the colour-coded and pulsed Doppler sonography give additional valuable information which improves the andrological diagnostics in the dog.  相似文献   

12.
The aim of this study was to identify ultrasound accessible blood vessels in the loggerhead sea turtle (Caretta caretta) and describe their Doppler waveform patterns, peak systolic velocity, mean velocity, systolic/diastolic ratio as well as pulsatility and resistive indices. B-mode, colour and pulsed-wave Doppler examinations were performed on 10 turtles. Flow measurements were recorded for the left and right aorta, epigastric and internal iliac arteries, and right hepatic vein. Additionally, the large blood vessels of three dead turtles were injected with latex and dissected for anatomical support. A parabolic flow velocity profile was observed in all arteries. The waveforms of the right and left aortic arteries showed an unusual pattern when compared with mammals. The hepatic vein flow velocity waveform of the loggerhead sea turtle was found to be similar to that in the dog, although the flow velocity in the C-wave was higher than that in the A-wave. The low resistance flow pattern observed suggests that the loggerhead sea turtle's organs require a continuous blood supply.  相似文献   

13.
The purpose of this study was to compare the haemodynamic effects of equipotent isoflurane and halothane anaesthesia. Six adult horses were investigated on two separate occasions at least 4 weeks apart. On both occasions anaesthesia was induced by ketamine 2.2 mg/kg bwt given 5 min after i.v. administration 100 microg/kg bwt romifidine. Anaesthesia was maintained either by halothane or isoflurane (end-tidal concentrations 0.9-1.0% and 1.3-1.4%, respectively). Horses were ventilated by intermittent positive pressure to maintain PaCO2 between 40-50 mmHg. Haemodynamic variables were measured using catheter-mounted strain gauge transducers in the left and right ventricle, aorta, and right atrium. Cardiac output (CO), velocity time integral (VTI), maximal aortic blood flow velocity (Vmax) and acceleration (dv/dt(max)), left ventricular pre-ejection period (PEP) and ejection time (ET) were measured from aortic blood flow velocity waveforms obtained by transoesophageal Doppler echocardiography. Flow velocity waveforms were recorded from the femoral arteries and veins using low pulse repetition frequency Doppler ultrasound. Time-averaged mean velocity (TAV), velocity of component a (TaVa), velocity of component b (TaVb) and early diastolic deceleration slope (EDDS) were measured. Pulsatility index (PI) and volumetric flow were calculated. Microvascular blood flow was measured in the left and right semimembranosus muscles by laser Doppler flowmetry. Maximal rate of rise of LV pressure (LVdp/dt(max)), CO, Vmax, dv/dt(max), ET, VTI were significantly higher at all time points during isoflurane anaesthesia compared to halothane anaesthesia. Pre-ejection period and diastolic aortic blood pressure were significantly less throughout isoflurane anaesthesia compared to halothane. Isoflurane anaesthesia was associated with significantly lower systemic vascular resistance than halothane anaesthesia. Femoral arterial and venous blood flow were significantly higher and EDDS and PI were significantly lower during isoflurane anaesthesia compared to halothane anaesthesia. In addition during both halothane and isoflurane anaesthesia, femoral arterial flow was higher and EDDS and PI lower in the left (dependent) artery compared to the right (nondependent) artery. This study supports previous work demonstrating improved left ventricular systolic function during isoflurane compared to halothane anaesthesia. This improvement was still evident after premedication with a potent-long acting alpha2-adrenoreceptor agonist, romifidine, and induction of anaesthesia with ketamine. There was also evidence of increased hindlimb blood flow during isoflurane anaesthesia. However, there were differences observed in flow between the left and right hindlimb during maintenance of anaesthesia with each agent, suggesting that there were differences in regional perfusion in anaesthetised horses caused by factors unrelated to agents administered.  相似文献   

14.
OBJECTIVE: To determine blood flow patterns in the common carotid artery and external jugular vein in cows before and after sedation achieved by administration of xylazine hydrochloride. ANIMALS: 30 clinically normal Swiss Braunvieh cows. PROCEDURE: A 5.0-MHz sector transducer was used to examine the common carotid artery and external jugular vein before and after cows were sedated by administration of xylazine. Several variables were calculated, including diameter of the blood vessels, blood flow velocity, and flow-time volume. RESULTS: The common carotid artery before sedation had a maximum systolic velocity of 89 +/- 8.5 cm/s, maximum diastolic velocity of 36 +/- 6.0 cm/s, mean velocity of 35 +/- 5.4 cm/s, and flow-time volume of 28.2 +/- 3.48 cm3/s. In all cows, sedation achieved by administration of xylazine resulted in a significant decrease in velocity of arterial blood flow and flow-time volume. The external jugular vein before sedation had a maximum velocity of 65 +/- 8.3 cm/s, maximum velocity of retrograde venous blood flow of 20 +/- 6.6 cm/s, and flow-time volume of 29.7 +/- 5.42 cm3/s. These values decreased significantly after cows were sedated by administration of xylazine. CONCLUSIONS AND CLINICAL RELEVANCE: Doppler ultrasonography is particularly suitable for evaluation of blood flow patterns in the common carotid artery and external jugular vein of healthy cows. The results reported here provide a basis for use in examination of cows with cardiac and blood vessel disease.  相似文献   

15.
Hypobaric (high-altitude) hypoxia is a physiologic cause of pulmonary hypertension, and alters left ventricular (LV) systolic and diastolic function. In the presence of tricuspid regurgitation, systolic pulmonary artery pressure can be measured noninvasively using the peak tricuspid regurgitation velocity and the Bernoulli equation. In the absence of measurable tricuspid regurgitation, severity of pulmonary hypertension may be estimated using two-dimensional, M-mode, and Doppler-derived parameters. To evaluate the usefulness of echocardiographic parameters for detecting mild-to-moderate pulmonary hypertension caused by moderate-to-marked hypoxia and to study the effect of high-altitude hypoxia on systolic and diastolic LV function in dogs, 19 Greenland dogs were examined at moderate altitude (2300 m) and high altitude (3500 m), and 10 Greenland control dogs were examined at 700-900 m. Evaluated parameters were pulmonary flow profile (shape, right ventricular acceleration time (RVAT), ejection time (RVET), RVAT/ET), peak mitral inflow velocities (LVE, LVA, LVE/A-ratio), LV % fractional shortening (FS), systolic time intervals (LVPEP, LVPEP/ET), and stroke volume index (SVI). Notching during deceleration was common in dogs at high altitude and in the control dogs, but not in dogs at moderate altitude. RVAT was shorter in dogs at high altitude compared with moderate altitude, but not compared with control dogs. Peak A-velocity was higher and E/A-ratio was lower in dogs at high altitude compared with moderate altitude and control dogs. FS was increased in dogs at high altitude compared with moderate altitude, and LVPEP and LVPEP/ET were shorter in the dogs at high altitude compared with moderate altitude and control dogs. In conclusion, significant differences in pulmonary flow profiles and systolic and diastolic parameters can be observed echocardiographically in dogs at different degrees of hypobaric hypoxia. However, overlap between the groups compromises their usefulness for diagnosing and estimating the degree of mild-to-moderate pulmonary hypertension in individual dogs.  相似文献   

16.
Ultrasonography of the femoral artery in the horse, including color, power and spectral Doppler, provides morphologic and dynamic information. This paper describes the use of the techniques in six clinically normal horses and three with femoral artery thrombosis. Useful landmarks for orientation are the saphenous artery and the medial saphenous vein. The lateral circumflex femoral artery can not be visualized. Recognition of the genus descendens artery is complicated due to the presence of multiple distal caudal femoral arteries. The femoral artery feeds a high resistance bed. In normal horses the peak systolic velocity varies between 50–90 cm/sec. Echoic tissue in the femoral artery lumen with stenosis, occlusion and collateral blood flow formation are features encountered in the patients.  相似文献   

17.
Transcranial Doppler ultrasonography (TCD) may be useful for determining alterations in cerebral blood flow (CBF) during excessive hemodynamic changes by non-invasive measurement of the CBF velocity. The purpose of this study was to measure the correlation between CBF and the middle cerebral artery (MCA) and basilar artery (BA) flow velocities, as measured by TCD during excessive hemodynamic changes produced by hypertension and hypotension in adult dogs. The peak, diastolic, and mean flow velocities were measured by TCD. Arterial hypertension was induced by administration of dopamine at 5 and 15 microg/kg/min, and hypotension was induced by hemorrhage. During the hemodynamic changes, the BA velocity correlated more closely with the alteration in the CBF than the MCA velocity. In terms of percentages of the values during anesthesia, there was good correlation between CBF and the MCA and BA velocities. In conclusion, our findings indicate that MCA and BA velocity measurements, as a percentage of the values during anesthesia, both give an equally accurate indication of alterations in CBF during excessive hemodynamic changes.  相似文献   

18.
A preliminary study was conducted to compare uncomplicated canine babesiosis (CB) and experimentally induced normovolaemic anaemia (EA) using Doppler ultrasonography of abdominal splanchnic vessels. Fourteen dogs with uncomplicated CB were investigated together with 11 healthy Beagles during severe EA, moderate EA and the physiological state as a control group. Canine babesiosis was compared with severe EA, moderate EA and the physiological state using Doppler variables of the abdominal aorta, cranial mesenteric artery (CMA), coeliac, left renal and interlobar, and hilar splenic arteries, and the main portal vein. Patterns of haemodynamic changes during CB and EA were broadly similar and were characterised by elevations in velocities and reductions in resistance indices in all vessels except the renal arteries when compared with the physiological state. Aortic and CMA peak systolic velocities and CMA end diastolic and time-averaged mean velocities in CB were significantly lower (P < 0.023) than those in severe EA. Patterns of renal haemodynamic changes during CB and EA were similar. However, the renal patterns differed from those of aortic and gastrointestinal arteries, having elevations in vascular resistance indices, a reduction in end diastolic velocity and unchanged time-averaged mean velocity. The left renal artery resistive index in CB was significantly higher (P < 0.025) than those in EA and the physiological state. Renal interlobar artery resistive and pulsatility indices in CB were significantly higher (P < 0.016) than those of moderate EA and the physiological state. The similar haemodynamic patterns in CB and EA are attributable to anaemia, while significant differences may additionally be attributed to pathophysiological factors peculiar to CB.  相似文献   

19.
This study was performed to characterize the normal blood flow of the canine testis and to measure the peak systolic velocity (PSV), end-diastolic velocity (EDV), resistive index (RI) and pulsatility index (PI) of testicular arteries weekly during a period of 6 months in five healthy Beagle dogs and to evaluate whether there were any change along this time. The ultrasonographic exams were made with an 11 MHz linear transducer. The vessels of the testes were subdivided into three categories: supratesticular arteries, marginal artery and intratesticular vessels. At the supratesticular arteries, two measurements were recorded at the cranial and the looping parts. No significant differences in any of the parameters studied were observed for the 6 months that the study was performed. The cranial part of the supratesticular artery showed a flow pattern of high-resistive vessel, whereas in the looping part of the supratesticular artery, marginal and intratesticular arteries, the flow showed a low-resistance pattern. PSV, RI and PI values were higher at the cranial part of the supratesticular artery, followed by the looping part of the supratesticular artery, marginal and intratesticular vessels. EDV measurements were higher in the looping part of the supratesticular artery.  相似文献   

20.
This study was carried out with the objectives to test the differences in the haemodynamic characteristics of the prostatic artery in normal and benign prostatic hyperplasia (BPH)–affected dogs using Doppler ultrasonography. In sixteen male German shepherd dogs, prostatic volume was detected and prostatic biopsy was performed. The prostatic artery blood flow parameters determined were as follows: peak systolic velocity (PSV), end diastolic velocity (EDV), Resistive Index (RI) and Pulsatility Index. The power Doppler mode was used for colour flow mapping of the prostatic artery. In PW mode at marginal locations, the waveforms recorded showed a continuous pattern typical of the high‐resistance vessels, while in subcapsular locations, the waveforms recorded were continuous characteristic of the low‐resistance vessel. Peak systolic velocity and EDV in both locations were significantly higher in BPH group (p < 0.001) than normal group (p < 0.05). Pixel number in BPH group in both locations was significantly higher (p < 0.05) compared to the normal group. This study shows that Doppler ultrasonography represents a valid and non‐invasive method for the characterization of the blood flow in the prostatic artery in dogs affected with BPH. Moreover, statistically significant differences of blood flow velocities in prostatic artery in normal and BPH‐affected dogs were detected. The RI was not able to differentiate normal dogs from dogs affected by BPH and therefore is not a parameter usable for diagnostic purposes, while Power Doppler could represent an additional diagnostic tool.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号