首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
5.
6.
7.
The anatomical and clinical studies of computed tomography (CT) in Camelidae are scarce. The use of CT in large animal medicine is currently limited by the logistic problems of acquiring computed tomographic images. Several CT studies exist on adult llamas, but not in camels. Accurate interpretation of the planimetric CT normal anatomy is necessary for the study and evaluation of pathological tissues. The purpose of our work was to evaluate the thorax of the newborn camel and related structures by means of CT images and macroscopic sections. One newborn camel of one week was used. It was euthanized for medical reasons unrelated to disease of the thorax. CT images were obtained and detailed anatomy of the thorax was acquired. Different CT windows, soft‐tissue and pulmonary windows, were applied in order to obtain detailed attenuation shades of the thoracic structures. The camel was frozen and sectioned using an electric saw, and we obtained high quality images of the thorax compared with CT images. Clinically relevant anatomic structures of the thorax cavity were identified and labelled in the corresponding CT and gross‐section photographs. The information presented in this paper should serve as an initial reference to evaluate CT images of the newborn camel thorax.  相似文献   

8.
9.
10.
11.
Objectives— To compare the precision of radiography and computed tomography (CT) preoperatively in the standing position for identification of guidelines for screw insertion in the distal phalanx, and to identify whether standing CT might improve operative time compared with preoperative radiographic planning.
Study Design— Experimental ex vivo study.
Animals— Cadaveric equine thoracic limb pairs (n=10).
Methods— Insertion of a 4.5 mm cortex screw in lag fashion into an intact distal phalanx was evaluated in 2 groups (n=10) of cadaveric equine thoracic limbs. In 1 group, the site, direction, and length of the implant were determined by radiography, and in the other group, by CT. Accuracy of screw placement was verified by specimen dissection. Outcomes were (1) absence of penetration of the articular surface, the solar surface, or the semilunar canal (2) appropriate length and direction of the screw. Surgical time was also measured.
Results— No screw penetrated the articular surface, the solar surface, or the semilunar canal in either group. CT was more accurate to identify guidelines for screw insertion (U=23.50, P =.049). With CT, surgical time (mean, 7.7 minutes) was significantly shorter (U=0.000, P =.000) than with radiography (mean, 12.7 minutes).
Conclusion— Standing CT can be used to accurately determine anatomic landmarks for screw insertion in lag fashion in sagittal fractures of the distal phalanx.
Clinical Relevance— This study has a clear clinical relevance for improved internal fixation of sagittal fractures of the distal phalanx.  相似文献   

12.
An 18-year-old Quarter Horse mare was evaluated because of moderate left forelimb lameness of 4 weeks’ duration. The clinical evaluation and diagnostic perineural analgesia localized the lameness to the distal portion of the left forelimb. There was swelling on the dorsal and lateral aspect of the coronary band. Radiography, ultrasound, magnetic resonance imaging, and computed tomography of the foot revealed circumscribed well-capsulated soft tissue mass causing a focal deformation of the dorsolateral border of the middle phalanx. The treatment aimed to remove the mass surgically and stabilized the interphalangeal joint, but the owner elected human euthanasia before treatment attempt. Histopathology diagnosis was an epidermoid cyst, which was characterized by multilayers of keratin surrounded by stratified squamous epithelium. Although rare, an epidermoid cyst should be considered as a differential diagnosis for space-occupying mass in horses’ foot that develops chronic lameness after trauma. This report describes the multimodality appearance of the epidermoid cyst.  相似文献   

13.
14.
15.
16.
17.
Over the last two decades, there have been significant advances in the use of assisted reproductive technology for genetic and reproductive management of captive dolphin populations, including evaluation of sperm DNA quality. This study validated a customized sperm chromatin dispersion test (SCDt) for the bottlenose dolphin (Tursiops truncatus) as a means of assessing sperm DNA damage both in the field and in the laboratory. After performing the SCDt, two different sperm morphotypes were identified: (i) sperm with fragmented DNA showed large haloes of dispersed DNA fragments emerging from a compact sperm nucleoid core and (ii) sperm containing non‐fragmented DNA displayed small compact haloes surrounded by a dense core of non‐dispersed DNA and protein complex. Estimates of sperm DNA fragmentation by means of SCDt were directly comparable to results obtained following a two‐tailed comet assay and showed a significant degree of correlation (= 0.961; p < 0.001). This investigation also revealed that the SCDt, with minor modifications to the standard protocol, can be successfully conducted in the field using a LED florescence microscopy obtaining a high correlation (= 0.993; p = 0.01) between the data obtained in the laboratory and in the field.  相似文献   

18.
Objective —To develop a radiographic procedure to measure dorsolateral subluxation (DLS) of the femoral head in canine coxofemoral (hip) joints in a weight-bearing position. Study Design —DLS measured on a radiographic projection was compared with DLS measured on computed tomography (CT) images of hip joints in a weight-bearing position. Animals —A total of 24 dogs of varying ages were examined including Labrador retrievers, greyhounds, and Labrador-greyhound crossbreeds. Methods —Anesthetized dogs were placed in sternal recumbency in a kneeling position in a foam rubber mold. The stifles were flexed and adducted with the femora perpendicular to, and in contact with, the table. To test for DLS, dogs were imaged in this weight-bearing position (DLS test) with routine radiography and CT. For each hip, the DLS score was determined by measuring the percentage of the femoral head medial to the lateralmost point of the cranial acetabular rim on the dorsoventral radiographic projection and the lateralmost point of the central, dorsal acetabular rim on the CT image. Higher DLS scores indicated better coverage of the femoral head by the acetabulum. DLS scores were compared with the distraction index (DI) by grouping joints according to their probability of developing osteoarthritis (OA) as predicted by the DI. Results —The DLS score in the new position ranged from 29% to 71% for radiography and 15% to 59% for CT. Joints classified as OA unsusceptible had a mean score of 64%± 1.5% for radiography and 55%± 0.8% for CT (n = 10); hip joints having a high probability of developing OA had a score of 39%± 2.6% for radiography and 26%± 1.9% for CT (n = 8). When the DLS test was repeated on the same dogs at a different time, the intraclass correlation coefficient for the DLS score on the radiographs was 0.85 (left hip) and 0.89 (right hip). There was a strong correlation (r = .89 for both hips) between the DLS score measured on the weight-bearing radiograph and the CT image. A strong correlation also was observed between the DLS score and the DI (r = -.87). The DLS scores for OA unsusceptible joints and joints with a high probability of developing OA were significantly different (P < .05). Conclusions and Clinical Relevance —The DLS test can be performed with CT or routine radiography to measure variable amounts of DLS in weight-bearing hip joints oriented similarly to those of a standing dog. After additional long-term follow-up studies evaluating the development of OA and breed effects are performed, the DLS method may prove useful in studies of normal and abnormal hip joint development related to canine hip dysplasia.  相似文献   

19.
20.
Computed tomography (CT) is a modern technique of image diagnosis particularly recommended in human medicine to evaluate the existence of pulmonary pathological changes such as neoplasms, metastasis, interstitial infiltrates, etc. In veterinary medicine, however, few anatomical and clinical CT studies in the dog have used apparatus of the latest generation, including injection of intravenous contrast and application of regional specific CT windows with different window width (WW) and window level (WL) to evaluate the lungs, the pulmonary vessels and the bronchial structures. This methodology allows the obtaining of clear CT images with high capacity of tissue discrimination and different shades of attenuation. In this work we have planned a tomographic study of the lungs of the dog by using a six-generation spiral CT scanner (Toshiba Ex Vision), belonging to the private Medical Institute of Radiology 'Irion' of Porto Alegre, Brazil. Four mixed-breed mature dogs (4–6 years, 15–20 kg) were used, two males and two females. The dogs were anaesthetized and kept in a maximum inspiration when obtaining the images. Dogs were placed in a stretcher in a ventral or sternal recumbency. Previously, the contrast urografin® was injected in the cephalic vein. Different CT windows were applied in order to increase the quality of the images: pulmonary window (WW 928; WL -680), high-resolution pulmonary window (WW 1085; WL -750), and soft tissue window (WW 652; WL -34). The use of intravenous contrast, different CT windows and a modern CT apparatus produced excellent images of the pulmonary parenchyma, the pleural cavity, the pulmonary veins, the lobular rami of the pulmonary artery and the lobular bronchi.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号