首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Introduction/objectivesPulmonary artery dissection is a rare complication following balloon valvuloplasty for pulmonic stenosis. We sought to report the rate of this complication in dogs and describe the demographic, clinical, procedural, and outcome data in affected dogs.Animals, materials and methodsMedical records at a single academic institution between 2002 and 2021 were reviewed for dogs with pulmonic stenosis treated by a balloon valvuloplasty. Dogs were included for evaluation if there was evidence of pulmonary artery dissection on echocardiography or necropsy following balloon valvuloplasty. The demographic, clinical, surgical, and follow-up information were then recorded.ResultsSix dogs were included from 210 balloon valvuloplasty procedures for pulmonic stenosis giving a 3.9% rate of pulmonary dissection. There was a variety of signalment, pulmonary valve morphologies, and balloon catheter types used in each dog. All dogs had severe pulmonic stenosis (median pressure gradient of 208 mmHg, range 94–220 mmHg) with 5/6 dogs having a pressure gradient >144 mmHg. The median balloon to pulmonary valve annulus ratio was 1.35 (range 1.25–1.5). Three dogs died perioperatively, and three dogs were alive at follow up 3.3, 4.0, and 4.1 years postoperatively.ConclusionPulmonary artery dissection is a rare complication following balloon valvuloplasty for pulmonic stenosis. Extreme elevations in preoperative pulmonary valve flow velocity were common. Prognosis is variable, with a potential 50% perioperative survival rate, but extended survival times were noted in those patients discharged from hospital.  相似文献   

2.
Placement of an Amplatz Canine Duct Occluder (ACDO) is usually performed by fluoroscopy (Nguyenba and Tobias, 2007). The latter technical approach presents limitations, mostly due to radiation exposure, making this practice dangerous for the patient and operators. In this study, we describe the successful placement of an Amplatz Canine Duct Occluder device by using transthoracic echocardiographic (TTE) guidance, performed on an 11-month-old female mongrel dog with a grade VI/VI continuous heart murmur diagnosed with patent ductus arteriosus (PDA). The TTE is useful in eliminating exposure to radiation and is more versatile than fluoroscopy in conveying real-time detailed information concerning the position of the ACDO.  相似文献   

3.
A 6-months old female German shepherd dog was referred for management of congenital heart disease. A diagnosis of pulmonic stenosis (PS) and patent ductus arteriosus (PDA) was confirmed by Doppler echocardiography and cardiac catheterisation. The conditions were treated during a single cardiac catheterisation procedure using percutaneous techniques. Gianturco coil embolisation was used to close the PDA, and the PS was relieved using a balloon valvuloplasty technique.  相似文献   

4.
ObjectiveTo evaluate the effect of a prophylactic lidocaine constant rate infusion (CRI) on the incidence and malignancy of catheter-induced ventricular ectopic complexes (VECs) during balloon valvuloplasty for management of pulmonic stenosis in dogs.Study designSingle-centre, prospective, randomized study.AnimalsClient-owned dogs (n = 70) with pulmonic stenosis.MethodsDogs were randomly assigned to one of two anaesthetic protocols: administration of lidocaine 2 mg kg–1 bolus followed by a CRI (50 μg kg–1 minute–1; group LD) or a saline placebo (group SL) during balloon valvuloplasty. All dogs were premedicated with methadone (0.3 mg kg–1) intramuscularly and a digital three-lead Holter monitor was applied. Anaesthetic co-induction was performed with administration of alfaxalone (2 mg kg–1) and diazepam (0.4 mg kg–1), and anaesthesia was maintained with isoflurane vaporised in 100% oxygen. CRIs were started on positioning of the dog in theatre and discontinued as the last vascular catheter was removed from the heart. All dogs recovered well and were discharged 24 hours postoperatively. Blinded Holter analysis was performed by an external veterinary cardiologist using commercially available dedicated analysis software; p < 0.05.ResultsOf the 70 dogs enrolled in the study, 61 were included in the final analysis: 31 in group LD and 30 in group SL.There was no significant difference between sinus beats (p = 0.227) or VECs (p = 0.519) between groups. In group LD, 19/31 (61.3%) dogs had a maximum ventricular rate ≥250 units and 20/30 (66.7%) dogs in group SL (p = 0.791).Conclusion and clinical relevanceIn this study, the use of a prophylactic lidocaine bolus followed by CRI in dogs undergoing balloon valvuloplasty for management of pulmonic stenosis did not significantly decrease the incidence nor the malignancy of VECs during right heart catheterization compared with a saline CRI.  相似文献   

5.
ObjectivesTo evaluate the natural history of primary pulmonic infundibular stenosis in cats and the effects of balloon valvuloplasty.BackgroundPrimary pulmonic infundibular stenosis is an uncommon congenital defect in cats. The natural history of the disease has not been described. Information regarding balloon valvuloplasty in the cat is limited.AnimalsRecords between January 1, 1999 and December 31, 2005 were reviewed and cats with a confirmed echocardiographic diagnosis of primary pulmonic infundibular stenosis, a complete medical history, and no evidence of significant systemic disease were identified.MethodsEchocardiographic, electrocardiographic, and radiographic findings are described. The natural history of those with severe disease was compared to those with mild to moderate disease. Balloon valvuloplasty was performed in six of the cats. The technique used is described.ResultsA stenotic gradient ≥70 mmHg and a right ventricular outflow tract (measured at the level of the stenosis) to pulmonary valve annulus ratio of ≤0.25 were consistent with clinical and echocardiographic severe disease. Cats with severe disease had a very guarded prognosis with a high incidence of congestive heart failure (CHF). Balloon valvuloplasty was successfully performed in 4 of the cats and appeared to improve prognosis, especially if performed prior to the development of CHF. Concurrent hypertrophic cardiomyopathy complicated the outcome in some cats.ConclusionsSevere primary pulmonic infundibular stenosis carries a very guarded prognosis in the cat. Balloon valvuloplasty should be considered in the presence of severe disease and should be performed prior to the development of CHF if possible. The presence of concurrent hypertrophic cardiomyopathy may complicate the prognosis.  相似文献   

6.
Case records of 30 dogs in which valvular pulmonic stenosis (PS) was treated by balloon dilation were reviewed retrospectively. Physical examination, thoracic radiographs, 9-lead ECG, echocardiography, and Doppler studies were performed in all dogs. Two-dimensional and Doppler echocardiography were repeated after 24 h and 1 year after treatment. Dogs were divided into 2 groups based on their valvular anatomy on echocardiography and aortic:pulmonary ratio: 18 had type A PS with normal annulus diameter and aortic:pulmonary ratio < or = 1.2, and 12 had type B PS with pulmonary annulus hypoplasia and aortic:pulmonary ratio > 1.2. Most dogs in the type B group were brachycephalic and had no poststenotic dilatation on thoracic radiographs. Of the dogs with type A stenosis, 100% survived valvuloplasty with resolution of clinical signs. At 1-year follow-up, 94.4% were still alive and remained asymptomatic. Of those with type B stenosis, 66.6% had favorable outcome postvalvuloplasty. At 1-year follow-up, 66.6% of dogs were alive, and resolution of clinical signs was obtained in 50%. This study revealed the immediate and long-term efficacy of balloon valvuloplasty in dogs with PS.  相似文献   

7.
ObjectiveDetermine if plasma N-terminal pro-brain natriuretic peptide (NT-proBNP) correlates with markers of hemodynamically significant patent ductus arteriosus (PDA) in dogs.AnimalsTen dogs with PDA and 30 healthy dogs of similar ages.MethodsProspective case series with control population. Dogs with PDA were initially evaluated with thoracic radiographs, transthoracic echocardiography, pulmonary capillary wedge pressure (PCWP) and NT-proBNP. Following ductal occlusion, NT-proBNP and echocardiography were repeated within 24 h and at day 90. PCWP was repeated at day 90. Correlation between NT-proBNP and hemodynamic measurements was assessed, and accuracy of NT-proBNP for identifying PDA severity was estimated.ResultsNT-proBNP was significantly higher (median; absolute range) in dogs with PDA (895; 490–7118 pmol/L) than controls (663; 50–1318 pmol/L) (p = 0.025). NT-proBNP decreased significantly 90 days post-ductal closure (597; 154–1858 pmol/L) (p = 0.013). Left atrial and ventricular size decreased significantly within 24 h and at day 90 as did PCWP (day 90 only). NT-proBNP correlated with vertebral heart size (VHS) and indexed left ventricular systolic diameter (iLVIDs); concentrations ≥ 1224 pmol/L distinguished dogs with elevated VHS and iLVIDs.ConclusionsNT-proBNP is elevated in dogs with PDA, decreases following PDA closure and correlates with select radiographic and echocardiographic markers of cardiac remodeling.  相似文献   

8.
Pulmonary valve stenosis (PS) is one of the most commonly diagnosed congenital heart defects in dogs. Currently, transthoracic echocardiography (TTE) is the standard modality used to evaluate PS. Image acquisition by TTE can be challenging in some brachycephalic breeds of dogs. The use of echocardiographic‐gated CT angiography (ECG‐gated CTA) in veterinary medicine is limited. This retrospective method comparison study investigated right and left ventricular outflow diameters by sedated ECG‐gated CTA and unsedated TTE in 14 brachycephalic dogs with PS and 12 brachycephalic dogs without PS. Measurements of ventricular outflow structures were made in early systole and end diastole for both modalities and then compared for significance between systolic and diastolic phases, as well as between the two modalities. Ratios of the pulmonary trunk diameter to the aorta at different locations (aortic valve, aortic annulus, and ascending aorta) and in different planes (transverse, sagittal) were compared between dogs with PS and without PS, as well as within dogs, by both TTE and ECG‐gated CTA. Transthoracic echocardiography and ECG‐gated CTA both detected significantly greater pulmonary trunk to aorta ratios in dogs with PS at all aortic locations (P < 0.05). Pulmonary valve to aortic valve ratios were significantly smaller in dogs with PS (P < 0.05). Pulmonary trunk to aorta and pulmonary valve to aorta ratios were achieved with good anatomic detail using ECG‐gated CTA. Ratios of the pulmonary trunk and pulmonary valve relative to the aorta may be useful to evaluate for PS using a modality that is underutilized for cardiac assessment.  相似文献   

9.
The Amplatz® canine duct occluder (ACDO) is a nitinol mesh device with a short waist that separates a flat distal disc from a cupped proximal disc. The device is designed to conform to the morphology of the canine patent ductus arteriosus (PDA). PDA dimensions are determined by angiography, and a guiding catheter is advanced into the main pulmonary artery via the aorta and PDA. An ACDO with a waist diameter approximately twice the angiographic minimal ductal diameter (MDD) is advanced via the catheter using an attached delivery cable until the flat distal disc deploys within the main pulmonary artery. The partially deployed ACDO, guiding catheter, and delivery cable are retracted until the distal disc engages the pulmonic ostium of the PDA. With the delivery cable stabilized, the catheter is retracted to deploy the waist across the pulmonic ostium and cupped proximal disc within the ductal ampulla. Tension on the delivery cable is released, and correct ACDO positioning and stability are confirmed by observing that the device assumes its native shape, back-and-forth maneuvering of the delivery cable, and a small contrast injection made through the guiding catheter. The delivery cable is detached and removed with the guiding catheter. To assess for any residual ductal flow, an angiogram is performed at the conclusion of the procedure, followed by Doppler echocardiography at 1 day and 3 months post-procedure. PDA occlusion in dogs with the ACDO is straightforward and extremely effective across a wide range of body weights, somatotypes, MDDs, and ductal morphologies.  相似文献   

10.
Background: Appropriate device selection for transcatheter occlusion of patent ductus arteriosus (PDA) is essential to procedural success. Objectives: To determine if transesophageal echocardiography (TEE) influences device selection for PDA occlusion and to report benefits, limitations, and complications associated with TEE. Animals: Twenty‐two client‐owned dogs with left‐to‐right shunting PDA. Methods: PDA dimensions were obtained via transthoracic echocardiography (TTE) and then TEE followed by angiography. Based solely on information from TTE and angiography, an initial device type and size were selected. After initial device selection, TEE measurements were disclosed and changes in device selection were recorded. After device release, angiography, TEE, or both were performed to assess occlusion. Results: An Amplatz canine duct occluder (ACDO) was securely positioned and released in 21 dogs and an embolization coil was deployed in 1 dog. Based on TEE evaluation, initial selected device type was unchanged but ACDO size was changed in 3 dogs. TEE was utilized throughout the procedure allowing real time visualization of device deployment, release and assessment of closure in 17 dogs. No complications occurred related to TEE. Complete PDA closure was achieved in all dogs. Conclusions and Clinical Importance: TEE provided anatomic information regarding PDA morphology that closely approximated angiographic ductal dimensions while aiding in device deployment, release and confirmation of closure. We conclude that TEE provides complementary anatomical and intraprocedural information and is well tolerated in dogs.  相似文献   

11.
A 5-year old, 5.8 kg, castrated male Pomeranian was diagnosed with a type IIa patent ductus arteriosus (PDA) with a minimal ductal diameter of 3.5 mm and ampulla width of 7.1 mm based on angiographic assessment. A 6 mm Amplatz® Canine Duct Occluder (ACDO) was deployed within the PDA. Once deployed, the device assumed it's native shape and back-and-forth maneuvering was performed with the delivery cable to assess device stability. Device position and complete occlusion were confirmed with both angiography and transesophageal echocardiography prior to and after release of the device. The device location was confirmed within the ductus arteriosus by echocardiography prior to discharge. The dog was discharged with instructions for strict activity restriction. Two days after discharge, the dog was left unsupervised in the backyard and shortly afterwards was found coughing with severe respiratory distress. The dog was evaluated at an emergency hospital and thoracic radiographs documented embolization of the ACDO to the main pulmonary artery along with a severe alveolar pattern throughout the right lung fields. Shortly after obtaining thoracic radiographs, the dog experienced cardiopulmonary arrest with unsuccessful resuscitation. This case describes a possible complication of transcatheter PDA occlusion with an ACDO, which has not been previously reported. An incident report, or catalog of adverse events with these devices, may prove useful in identifying additional fatal complications that others may have encountered, but are not reported in the literature. The report of this complication emphasizes the importance of strict activity restriction after device placement in dogs.  相似文献   

12.
ObjectivesTo describe the clinical and echocardiographic findings in dogs with quadricuspid aortic valve (QAV).BackgroundQAV is a rare canine congenital heart disease which has been reported only three times in the young dog.Animals, materials and methodsSix dogs (0.3- to 13-year-old) with QAV diagnosed by two-dimensional echocardiography were retrospectively evaluated. Medical records, echocardiograms, and follow-ups were reviewed.ResultsAccording to aortic cusp morphology, QAV was classified as type A (n = 1), type B (n = 4) or type C (n = 1). QAV was associated with at least one other heart disease in all of the dogs including, ventricular septal defect (n = 1), enlarged left coronary ostium (n = 4), degenerative mitral valve disease (MVD, n = 1) and patent ductus arteriosus (PDA, n = 3). Mild to moderate aortic regurgitation was also detected in all dogs by continuous-wave and color-flow Doppler echocardiography. QAV was diagnosed in four asymptomatic dogs referred for evaluation of a heart murmur. The remaining two dogs had QAV and PDA with evidence of mild exercise intolerance and moderately retarded growth. The PDA was surgically corrected in both dogs and at the time of writing, 1–2.5 years after the initial diagnosis, none of the six animals shows evidence of clinical signs.ConclusionQAV is a cause of aortic insufficiency. It may incidentally be found by two-dimensional echocardiography in dogs of various ages in association with other congenital or acquired cardiac abnormalities.  相似文献   

13.
IntroductionThe objective of the study was to evaluate the accuracy of two- and three-dimensional (2D, 3D) transthoracic echocardiography (TTE), 2D transesophageal echocardiography, and computed tomography angiography (CTA) compared with cardiac magnetic resonance imaging (CMR) in normal dogs and to assess repeatability of 2D and 3D TTE for the assessment of left ventricular (LV) and left atrial (LA) dimensions.AnimalsThe study was performed on six healthy dogs.Materials and MethodsTransthoracic echocardiography, transesophageal echocardiography, CTA, and CMR were performed on each dog. Right ventricular (RV) and LV volumes (in systole and diastole), ejection fraction (EF), and LA and right atrial (RA) volumes were assessed. Repeatability and intrarater and interrater measurements of variability were quantified by average coefficient of variation (CV) for 2D and 3D TTE.ResultsNo clinically relevant differences in LV volume were detected between CMR and all modalities. Importantly, 3D TTE had the lowest CV (6.45%), correlated with (rs = 0.62, p = 0.01), and had the highest overlap in distribution with CMR (OVL >80%). Left ventricular EF and LA size via CTA compared best with CMR and RV and RA volumes were best estimated by 3D TTE. Assessment of LV and LA volumes via 3D TTE had moderate repeatability (15–21%) compared with LV M-mode measurements and 2D LA-to-aortic ratio (<10%), respectively. For LV size, interrater CV for 3D TTE (19.4%) was lower than 2D TTE (23.1%).ConclusionsMeasurements of LV, RV, and RA volumes via 3D TTE and LA volume and LV EF assessed by CTA compared best with CMR. Three-dimensional echocardiography had lower interrater and intrarater CV compared with 2D TTE.  相似文献   

14.
Pulmonic valvuloplasty is a well-established method for the treatment of valvular pulmonic stenosis in people and dogs. In dogs, pulmonic valvuloplasty has been restricted to a single balloon; however, the simultaneous use of two balloons is common in pediatric cardiology. The use of two balloons provides an alternative to the use of a single large balloon in small dogs with a pulmonic anulus size that requires a large dilation catheter and large diameter introducer. Moreover, double balloon valvuloplasty permits dilation in large dogs with large pulmonic anulus sizes for which standard dilation catheters are not available. This report outlines the materials required, describes the technique, gives the advantages and disadvantages encountered when performing percutaneous double balloon valvuloplasty and provides some ‘tips’ for a successful outcome.  相似文献   

15.
Four adult dogs weighing <10 kg presented for the evaluation of severe mitral valve stenosis with clinical signs. Owing to the size of the dogs, a hybrid surgical and interventional approach was utilized for balloon valvuloplasty. A left lateral thoracotomy was performed to allow direct entry through the left atrial wall. Transesophageal echocardiography was utilized for the entirety of the procedure in all dogs, and fluoroscopy was additionally used in two dogs. One dog had mild to moderate intra-operative bleeding from the left atrial wall during the procedure, but no other intra-operative complications were observed. No dogs developed a clinically relevant amount of worsened mitral regurgitation. Based on mitral leaflet mobility and transmitral flow profiles, there was perceived improvement in all four dogs. One dog died 6 h after extubation due to respiratory arrest. The remaining dogs survived to discharge and had resolution of clinical signs at home and discontinuation of heart failure medications. One dog died of an unknown cause at five months and another developed atrial fibrillation, and the owners elected to euthanize at ten months after the procedure. One dog continues to do well six months after the procedure as of the time of this writing. Hybrid balloon valvuloplasty can be a viable management option for small breed dogs with severe mitral stenosis exhibiting clinical signs, and both transesophageal echocardiography and fluoroscopy can be used intra-operatively to assist in successful procedural outcomes.  相似文献   

16.
Background: English Bulldogs (EB) with pulmonic stenosis (PS) sometimes have an aberrant coronary artery (CA) type R2A encircling the pulmonary artery (PA). Balloon valvuloplasty (BV) is treatment of choice for severe PS, but is considered to be contraindicated in dogs with aberrant CA. Hypothesis: Conservative BV in EB with aberrant CA is safe and improves clinical signs and quality of life. Animals: Four client‐owned EB with severe PS were retrospectively reviewed/analysed. Methods: Retrospective study: Case records, echocardiography, BV, and follow‐up investigations of EB diagnosed with severe PS and treated with BV were reviewed. The ratios of PA to aortic (Ao) velocity time integral (VTI) were calculated to assess progression/improvement of PS. Results: An aberrant CA was confirmed on angiography in all EB. Conservative BV was performed, using a balloon of the size of the PA annulus or smaller (0.6–1 × PA annulus size). All dogs survived the procedure, but only a mild reduction in pressure gradient was achieved. There was an improvement in PA to Ao VTI in 3 of 4 dogs (P≤ .017), which were free of evidence of congestive heart failure (CHF) 5, 10, and 15 months after BV. One dog that had right‐sided CHF when BV was performed died due to progressive right‐sided CHF within 3 months. Conclusions: Conservative BV in EB might be safe and might improve quality and quantity of life.  相似文献   

17.
BACKGROUND: Per-catheter patent ductus arteriosus (PDA) occlusion in dogs with devices intended for humans is associated with technical difficulties, high rates of procedure abandonment, device migration, and residual ductal flow. HYPOTHESIS: Use of a custom-made canine duct occluder (Amplatz Canine Duct Occluder, ACDO) would be feasible in dogs of varying weights and somatotypes and effective in occluding a wide range of PDA shapes and sizes. ANIMALS: Eighteen client-owned dogs of various breeds with PDA. Weights ranged from 3.8 to 32.3 kg (median, 17.8 kg), and angiographic minimal ductal diameters ranged from 1.1 to 6.9 mm (median, 3.7 mm). Ductal morphologies included types IIA, IIB, and III. METHODS: Per-catheter PDA occlusion with the ACDO was performed in all dogs. Persistent or recurrent ductal flow was assessed at the end of the procedure by angiography and at 1 day, 3 months, and >or=12 months after the procedure by echocardiography. RESULTS: Successful ACDO placement was achieved in all 18 dogs. One dog required a 2nd procedure with a larger ACDO after the 1st device migrated to the pulmonary vasculature. Complete occlusion was confirmed in 17 of 18 dogs during the procedure, as well as at 1 day and 3 months after the procedure, and in 12 of 13 dogs evaluated at >or=12 months after the procedure. CONCLUSIONS AND CLINICAL IMPORTANCE: Per-catheter PDA occlusion in dogs with the ACDO is feasible and effective in dogs of a wide range of weights and somatotypes and with PDAs of varying shapes and sizes.  相似文献   

18.
Balloon valvuloplasty was performed on two dogs with pulmonic valve stenosis. Immediately following balloon valvuloplasty, peak right ventricular systolic pressure declined from 92 to 44 mm Hg in the first dog and from 108 to 46 mm Hg in the second dog. The peak systolic pressure gradient across the pulmonic valve declined from 60 to 12 mm Hg in the first dog and from 84 to 22 mm Hg in the second dog. Hemodynamic improvement was sustained in both dogs at the time of recatheterization 3 months later. Both dogs tolerated the procedure well and there were no serious complications. It was concluded that balloon valvuloplasty offers an alternative to surgery for the treatment of valvular pulmonic stenosis in dogs. The exact indications for and limitations of balloon valvuloplasty must await the results of additional and more long-term studies.  相似文献   

19.
Assessment of balloon pulmonary valvuloplasty in six dogs   总被引:1,自引:0,他引:1  
The effectiveness of balloon valvuloplasty was assessed, clinically and haemodynamically, in six dogs with moderate to severe pulmonic stenosis. The haemodynamic assessment was based on Doppler echocardiography, with colour flow mapping, in the conscious dog and by direct catheterisation in the anaesthetised dog, before and after balloon valve dilatation. Four of the six dogs were presented with exercise intolerance, of which two were in congestive heart failure. Balloon valvuloplasty resulted in improved exercise tolerance and resolution of congestive heart failure in these dogs. The average Doppler and catheter transvalvular pressure gradients were reduced to 43 per cent and 46 per cent of the preoperative gradient, respectively. The average pressure gradient obtained by catheter, in the anaesthetised dog, was 59 per cent of the pressure gradient obtained by spectral Doppler echocardiography in the conscious dog. Balloon valvuloplasty was considered successful in five out of the six dogs. Postoperative pulmonic regurgitation was not found to be a complication of balloon valvuloplasty.  相似文献   

20.
Transcatheter occlusion of patent ductus arteriosus (PDA) using an Amplatz® Canine Duct Occluder (ACDO) is routinely performed in dogs. Pulmonary embolization of the device is a rarely reported complication of this procedure. We report here the first two cases of successful transcatheter retrieval of an embolized ACDO. An 8-month-old, 21-kg, German shepherd (case 1) was referred for pulmonary edema secondary to a large PDA with left-to-right shunting. After medical stabilization, an emergency procedure for PDA closure was recommended. An 8-mm ACDO was deployed under general anesthesia. The device was released after confirming its stability with a gentle tug test but migrated into the pulmonary trunk. A 10-mm ACDO was subsequently successfully deployed and released. Vascular access was then obtained from the right jugular vein so that a vascular snare could be used to capture the ACDO waist and pull it back toward the right ventricle and then the right atrium. It was then removed through the jugular vein. The dog recovered uneventfully and was discharged after confirmation of complete ductal occlusion. The same complication occurred in a second case (case 2, asymptomatic 6-month-old, 7.9-kg, cocker spaniel), and a similar procedure was used to successfully retrieve the embolized device. Both dogs are still doing well 9 and 21 months, respectively, after the procedure. These cases illustrate that transcatheter retrieval of ACDO devices embolized in the pulmonary artery using vascular snares is technically feasible in the dog.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号