首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 186 毫秒
1.
A rapid confirmatory method for determining 12 sulfonamide (SAs) antibacterials in whole milk and eggs is presented. This method is based on the matrix solid-phase dispersion technique with hot water as extractant followed by liquid chromatography (LC)-mass spectrometry (MS). The LC-MS instrument was equipped with an electrospray ion source and a single quadrupole. After 4 mL of a milk sample containing the analytes had been deposited on sand (crystobalite), this material was packed into an extraction cell. SAs were extracted by flowing 4 mL of water through the cell heated at 75 degrees C. With some modifications, this procedure was applied also to eggs. After pH adjustment and filtration, 0.5 mL of the final extracts was then injected into the LC column. MS data acquisition was performed in the positive-ion mode and by monitoring at least three ions for each target compound. The in-source collision-induced dissociation process produced confirmatory ions. At the 50 ng/g level, recovery of the analytes in milk and eggs was 77-92% with relative standard deviations ranging between 1 and 11%. Estimated limits of quantification (S/N = 10) were 1-3 ng/g of SAs in milk and 2-6 ng/g in eggs. With both matrices, attempts to reduce the analysis time by using a short chromatographic run time caused severe ion signal suppression for the early-eluted SAs. This effect was traced to competition effects by polar endogenous coextractives, maybe proteinaceous species, which are eluted in the first part of the chromatographic run. This unwelcome effect was almost completely removed by simply adopting more selective chromatographic conditions.  相似文献   

2.
A rapid, specific, and sensitive procedure for determining four widely used tetracycline antibiotics and three related epimers in bovine, swine, and poultry muscle tissues is presented. The method is based on the matrix solid-phase dispersion technique with heated water as the extractant followed by liquid chromatography (LC)-tandem mass spectrometry (MS) equipped with an electrospray ion source. Target compounds were extracted from tissues with 5 mL of water heated at 70 degrees C. After acidification and filtration, 100 microL of the aqueous extract was injected in the LC column. MS data acquisition was performed in the multireaction monitoring mode, selecting two precursor ion to product ion transitions for each target compound. Heated water appeared to be an excellent extractant, since the absolute recovery data ranged between 70 and 78%. The accuracy of the method was determined at three spike levels, using minocycline as a surrogate analyte, in any different kind of muscle tissues considered and varied between 88 and 109% with relative standard deviations ranging between 3 and 11%. Limits of quantification were estimated to range between 1 (chlortetracycline) and 9 ng/g (4-epioxytetracycline), based on a signal-to-noise ratio of 10, and are well below the tolerance levels set by the European Union. The effects of the extraction temperature, volume of the extractant, and washing of the material supporting the biological matrix with ethylenediamine tetraacetic disodium salt on the analyte recovery were studied.  相似文献   

3.
A simple, specific, and sensitive procedure for determining six cyanotoxins, that is, microcystins RR, LR, YR, LA, and LW and nodularin, in fish muscle tissue is presented. This method is based on the matrix solid-phase dispersion technique with heated water as extractant followed by liquid chromatography (LC)-tandem mass spectrometry (MS) equipped with an electrospray ion source. Target compounds were extracted from tissue by 4 mL of water acidified to pH 2 and heated at 80 degrees C. After acidification and filtration, 0.2 mL of the aqueous extract was injected in the LC column. MS data acquisition was performed in the multireaction monitoring mode, with at least two precursor ion > product ion transitions selected for each target compound. Analyte recovery ranged between 61 and 82% and was not substantially affected by either the analyte concentrations or the type of fish. The nonexcellent recovery of some of the microcystins was traced to binding of these compounds to protein phosphatases in fish tissue occurring during sample treatment. The existence of covalently bound microcystins in fish has been evidenced by several studies. Compared to an older sample preparation procedure, this one extracted larger amounts of the analytes in a simpler and much more rapid way. On the basis of a signal-to-noise ratio of 10, limits of quantification were estimated to range between 1.6 and 4.0 ng/g. The effects of temperature and volume of the extractant on the analyte recovery were studied.  相似文献   

4.
A new methodology is described for rapidly determining the herbicide oryzalin in water, citrus fruits, and stone fruits by liquid chromatography with negative ion electrospray ionization tandem mass spectrometry (LC/MS/MS). Oryzalin is extracted from water using a polymeric sorbent solid phase extraction (SPE) column and from fruit using methanol. The water samples require no further purification, but an aliquot of the fruit sample extracts is diluted with water and purified using a polymeric 96 well SPE plate. Purified extracts are concentrated prior to determination by LC/MS/MS at m/z 345 (Q1) and m/z 281 (Q3) using an external standard for calibration. The validated limits of quantitation were 0.05 microg/L in water (drinking water, surface water, and groundwater) and 0.01 microg/g in citrus fruits (oranges and lemons) and stone fruits (peaches and cherries). Recoveries averaged 102% for water samples and 85-89% for the various types of fruit samples. For all fortification levels combined, the relative standard deviations ranged from 4 to 6% for water and from 2 to 4% for fruit.  相似文献   

5.
Two independently developed liquid chromatography (LC) methods for the quantitative determination of biotin in multivitamin/multielement tablets (NIST Standard Reference Material 3280 (SRM 3280)) are described. The methods use distinctly different tablet extraction solvents (methanol vs 1.5% aqueous formic acid) and analyte detection principles (mass spectrometry (MS) versus evaporative light-scattering detection (ELSD)) to ensure quantitative reliability. The use of different extraction and detection procedures allows cross-validation of the methods and enhances confidence in the final quantitative results. Both methods yield highly comparable results for the mean level of biotin (LC/MS = 26.5 mg/kg +/- 0.3 mg/kg (n = 12); LC/ELSD = 24.7 mg/kg +/- 1.7 mg/kg (n = 12)) in SRM 3280, yet the methods differ considerably in their analytical characteristics. The isotope-dilution LC/MS method exhibits excellent linearity from 0.02 ng to 77 ng biotin on-column with a method limit of detection (LOD) and limit of quantification (LOQ) of 0.02 ng (S/N > 3) and 0.06 ng (S/N > 10) biotin on-column, respectively. The LC/ELSD method exhibits good linearity from 155 ng to 9900 ng biotin on-column with a method LOD and LOQ of 155 ng (S/N > 3) and 310 ng (S/N > 10) biotin on-column, respectively. Method performance data indicates that the LC/MS method is analytically superior to the LC/ELSD method; however, either method in combination with SRM 3280 should provide quality assurance, accuracy, and traceability for biotin levels in multivitamin/multielement dietary supplements.  相似文献   

6.
A sensitive method has been developed for the simultaneous determination of residues of 25 β?-agonists and 23 β-blockers in animal foods by high-performance liquid chromatography coupled with linear ion trap mass spectrometry (HPLC-LIT-MS). This method is based on a new procedure of hydrolysis and extraction by 5% trichloracetic acid, and then cleaned up by mixed strong cation exchange (MCX) cartridges coupled with a novelty cleanup step by methanol. Methanol and 0.1% formic acid were used as mobile phases for gradient elution, while a Supelco Ascentis Express Rp-Amide column was used for LC separation. ESI positive ion scan mode was used with consecutive reaction monitoring (CRM, MS3). Nine β?-agonists labeled by the deuterium isotope were used as internal standards for quantification. The linear ranges of 48 analytes were from 5 to 200 μg/L; the coefficient of correlation was not less than 0.995. Blank pork muscle, blank liver, and blank kidney were selected as representative matrix for spiked standard recovery test. The recoveries of each compound were in the range of 46.6-118.9%, and the relative standard deviations were in the range of 1.9-28.2%. Decision limits (CCα, α = 0.01) of 48 analytes in muscles, liver, and kidney samples ranged from 0.05 to 0.49 μg/kg, and the detection capability (CCβ, β = 0.05) ranged from 0.13 to 1.64 μg/kg. This method was successfully applied to 110 real animal origin food samples including meat, liver, and kidney of pig and chicken samples.  相似文献   

7.
Analysis of coffee for the presence of acrylamide by LC-MS/MS   总被引:5,自引:0,他引:5  
A variety of popular instant, ground, and brewed coffees were analyzed using a modified liquid chromatography-tandem mass spectrometry (LC-MS/MS) method specifically developed for the determination of acrylamide in foods. Coffee test portions were spiked with 13C3-labeled acrylamide as an internal standard prior to their extraction and cleanup. Ground coffees (1 g) and instant coffees (0.5 g) were extracted by shaking with 9 mL of water for 20 min. Brewed coffee test portions (9 mL) were taken through the cleanup procedure without further dilution with extraction solvent. Coffee test portions were cleaned up by passing 1.5 mL first through an Oasis HLB (hydrophilic/lipophilic copolymer sorbent) solid phase extraction (SPE) cartridge and then a Bond Elut-Accucat (cation and anion exchange sorbent) SPE cartridge. The cleaned up extracts were analyzed by positive ion electrospray LC-MS/MS. The MS/MS data was used to detect, confirm, and quantitate acrylamide. The limit of quantitation of the method was 10 ng/g for ground and instant coffees and 1.0 ng/mL for brewed coffee. The levels of acrylamide ranged from 45 to 374 ng/g in unbrewed coffee grounds, from 172 to 539 ng/g in instant coffee crystals, and from 6 to 16 ng/mL in brewed coffee.  相似文献   

8.
A method based on a gel permeation chromatography (GPC) extraction procedure combined with an additional cleanup by solid-phase extraction (SPE) on silica gel and liquid chromatography-mass spectrometry (LC-MS) detection has been validated for the analysis of seven glycidyl esters (GEs) including glycidyl laurate, myristate, palmitate, stearate, oleate, linoleate, and linolenate in various edible oils. This method was conjointly developed and validated by two different laboratories, using two different detection systems, a LC time of flight MS (LC-ToF-MS) and a LC triple-quadrupole MS (LC-MS/MS). The extraction procedure allowed targeting low contamination levels due to a highly efficient matrix removal from the 400 mg oil sample loaded on the GPC column and is suitable for routine analysis as 24 samples can be extracted in an automated and reproducible way every 12 h. GPC extraction combined with SPE cleanup and LC-MS/MS detection leads to a limit of quantification in oil samples between 50 and 100 μg/kg depending on the type of glycidyl ester. Recoveries ranged from 68 to 111% (average = 93%). Quantification was performed by automated standard addition on extracts to compensate matrix effects artifacts. To control recoveries of each sample four isotopically labeled GEs ((13)C(3) or (13)C(4)) were included in the method.  相似文献   

9.
A simple, specific, and rapid analytical method for determining seven largely used carbamate insecticides in tomato, spinach, lettuce, zucchini, pear, and apple is here presented. This method is based on the matrix solid-phase dispersion technique, with heated water as extractant followed by liquid chromatography (LC)-mass spectrometry (MS) equipped with a single quadrupole and an electrospray ion source. Target compounds were extracted from the vegetal matrixes by water heated at 50 degrees C. After acidification and filtration, 0.25 mL of any aqueous extract was injected in the LC column. MS data acquisition was performed in the selected ion monitoring mode, selecting three ions for each target compound. Heated water appeared to be an excellent extractant because recovery data ranged between 76 (carbaryl in spinach) and 99% (pirimicarb in spinach), with RSDs not larger than 10%. Using trimethacarb (an obsolete carbamate insecticide) as a surrogate internal standard, the accuracy of the analysis varied between 84 and 110%, with RSDs not larger than 9%. On the basis of a signal-to-noise ratio of 10, limits of quantification were estimated to range between 2 (pirimicarb) and 10 ppb (oxamyl) and were not influenced by the type of matrix. When trying to fractionate analytes by using a short chromatographic run time, marked weakening of the ion signals for oxamyl, methomyl, and aldicarb were observed. This effect was traced to polar endogenous co-extractives eluted in the first part of the chromatographic run that interfered with gas-phase ion formation for carbamates. Adopting more selective chromatographic conditions eliminated this effect.  相似文献   

10.
A rapid LC-MS/MS method was developed for the quantitative determination of grayanotoxins I, II, and III in rumen contents, feces, and urine. The grayanotoxins were extracted from solid samples with methanol. The methanol extract was diluted with water and cleaned up using a reversed phase solid phase extraction column. HPLC separation was performed by reversed phase HPLC using a gradient of water and methanol containing 1% acetic acid. Determination was by positive ion electrospray ionization and ion trap tandem mass spectrometry. Grayanotoxin I quantitation was based on fragmentation of the sodium adduct ion at m/z 435 to a product ion at m/z 375. Grayanotoxins II and III were quantitated on the basis of fragmentation of the ion at m/z 335 to the product ion at m/z 299. The method detection limits were 0.2 microg/g in rumen contents and feces and 0.05 microg/g in urine. Fortifications at the detection limits and 10 times the detection limits of bovine rumen contents, caprine feces, and ovine urine were recovered in the range 80-114%. The diagnostic utility of the method was tested by analyzing samples submitted to the veterinary toxicology laboratory.  相似文献   

11.
A method was developed for detection of a variety of polar drug residues in eggs via liquid chromatography/tandem mass spectrometry (LC/MS/MS) with electrospray ionization (ESI). A total of twenty-nine target analytes from four drug classes-sulfonamides, tetracyclines, fluoroquinolones, and beta-lactams-were extracted from eggs using a hydrophilic-lipophilic balance polymer solid-phase extraction (SPE) cartridge. The extraction technique was developed for use at a target concentration of 100 ng/mL (ppb), and it was applied to eggs containing incurred residues from dosed laying hens. The ESI source was tuned using a single, generic set of tuning parameters, and analytes were separated with a phenyl-bonded silica cartridge column using an LC gradient. In a related study, residues of beta-lactam drugs were not found by LC/MS/MS in eggs from hens dosed orally with beta-lactam drugs. LC/MS/MS performance was evaluated on two generations of ion trap mass spectrometers, and key operational parameters were identified for each instrument. The ion trap acquisition methods could be set up for screening (a single product ion) or confirmation (multiple product ions). The lower limit of detection for screening purposes was 10-50 ppb (sulfonamides), 10-20 ppb (fluoroquinolones), and 10-50 ppb (tetracyclines), depending on the drug, instrument, and acquisition method. Development of this method demonstrates the feasibility of generic SPE, LC, and MS conditions for multiclass LC/MS residue screening.  相似文献   

12.
A new rapid and sensitive method based on matrix solid-phase dispersion (MSPD) followed by liquid chromatography-electrospray-tandem mass spectrometry was devised for the determination of biogenic amines at trace levels in cheese samples. The method required 0.25 g of sample, CN-bonded silica as a dispersant sorbent, and a formic acid aqueous solution/methanol mixture as an eluting solvent. Extraction recoveries from soft cheese products were calculated in the 98 +/- 4-110 +/- 6% range. A procedure based on solid-phase extraction was also evaluated for the extraction of these compounds in cheese. Chromatographic separation was performed using a C18 column with an aqueous ammonium acetate/methanol mixture as the mobile phase under gradient conditions. The method was validated in terms of detection limits (LOD), quantitation limits (LOQ), linearity, recovery, precision, and trueness. Results in the 0.05-0.25 mg kg(-1) range were obtained for the LOD of histamine, tyramine, and beta-phenylethylamine in soft cheese samples. Linearity was established over 2 orders of magnitude. Excellent precision in terms of intra-day repeatability was calculated (RSD% < 5). The applicability of the method to the determination of biogenic amines in cheese products was demonstrated.  相似文献   

13.
A reverse-phase liquid chromatographic (LC) method is described for simultaneously determining 5 coccidiostats--aklomide, dinsed, ethopabate, nitromide, and zoalene in chicken liver. The method entails blender extraction of 10 g liver with ethyl acetate, column chromatography through Sephadex LH-20 and neutral alumina, and LC analysis on a C18 column with UV detection at 260 nm. The drugs were eluted from Sephadex with methanol-benzene (10 + 90), from alumina with methanol-dichloromethane (10 + 90), and from C18 with acetonitrile-water (linear gradient: 25% acetonitrile for 10 min, increasing to 55% over 15 min; flow rate 1 mL/min). Liquid chromatography was completed in 40 min and calculations were based on peak height measurements. Average recoveries of the coccidiostats from fortified liver ranged from 72 to 97%, except for dinsed, which showed a relatively constant average recovery of 57%. The detection limit for the standards was 2.5 ng on column. Levels as low as 50 ng/g were detected in fortified liver samples.  相似文献   

14.
建立了基质固相分散萃取-高效液相色谱串联质谱法(MSPD-HPLC-MS/MS)测定土壤中3种磺酰脲类除草剂(氯磺隆、甲磺隆、苯磺隆)残留的分析方法。对基于球磨的基质固相分散萃取条件进行了详细优化,最终确定最佳条件为:0.2 g土壤样品、0.8 g HC-C18粉末状分散剂与直径为8 mm的小钢珠一起球磨10 min后,转移至空的玻璃萃取小柱,用10 m L乙腈洗脱,氮气吹干后用甲醇定容至0.6 m L,再经0.22μm的滤膜抽滤后装入自动进样瓶中。用Syncronis C18反相色谱柱分离,以甲醇(A)~1‰甲酸溶液(B)为流动相进行梯度洗脱,选择反应监测(SRM)模式下进行检测。氯磺隆在20~200μg·kg~(-1),甲磺隆和苯磺隆在10~200μg·kg~(-1)范围内线性良好,相关系数r在0.997 9~0.999 5。土壤样品的平均加标回收率在84.7%~104.6%,相对标准偏差在4.5%~7.9%(n=5)。方法的检出限(S/N=3)0.32~0.68μg·kg~(-1)。该方法简单、效率高、干扰少、回收率高,满足土壤中除草剂的残留分析要求。  相似文献   

15.
A specific and sensitive method based on liquid chromatography-tandem mass spectrometry using atmospheric pressure chemical ionization (LC-APCI-MS/MS) has been developed for the determination of four anabolic steroids [trenbolone, methylboldenone, methyltestosterone, and norethandrolone] in bovine muscle. Methyltestosterone- d 3 was used as internal standard. The procedure involved enzymatic hydrolysis, extraction with tert-butyl methyl ether, defattening, and final cleanup with solid-phase extraction with Oasis HLB cartridges. The analytes were analyzed by reversed-phase LC-MS/MS, acquiring two diagnostic product ions from the chosen precursor [M + H] (+) for the unambiguous confirmation of hormones. The method was validated according to the European Commission Decision 2002/657/EC for the detection and confirmation of residues in products of animal origin. The limits of detection (LOD) and limits of quantitation (LOQ) were found to be 0.3 ng/g and 1.0 ng/g, respectively. The accuracy and precision have been determined, with recoveries ranging from 83% to 104% and the CV factor not exceeding the value of 7%. The decision limits CCalpha were calculated and ranged from 0.05 to 0.15 ng/g while the detection capabilities CCbeta ranged from 0.09 to 0.25 ng/g. The method proved to be sensitive and reliable and thus renders an appropriate means for residue analysis studies.  相似文献   

16.
This paper describes a new method for the rapid extraction and unequivocal confirmation of 13 sulfonamides (SAs) in raw meat and infant foods. The highly automated extraction procedure is based on accelerated solvent extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) as a confirmatory analysis. After 1 g of food matrix was blended with 2 g of C18 as a solid support material, the mixture was packed into the extraction cell and the SAs were extracted with 10 mL of hot water at 160 degrees C and 100 atm; 100 microL of the extract was directly injected into the LC-MS system. The analytes were ionized in an electrospray interface operating in the positive ion mode and were identified by selecting two multireaction monitoring transitions, which guaranteed method specificity. Typical recoveries from crude meat and baby food samples ranged from 70 to 101% at a fortification level of 100 ppb, corresponding to the maximum residue limits established by the European Union and the U.S. Food and Drug Administration. The interday method precision was less than 8.5%, and the limits of detection were below 2.6 ppb. This study has taken matrix-induced suppression of ionization into account, by comparing standard and matrix-matched calibration curves. Four of the 13 monitored SAs have been detected in some baby foods and raw meat samples, bought from Roman supermarkets and butchers' shops, using the described methodology.  相似文献   

17.
Butachlor is a chloroacetanilide herbicide successfully employed in weeding some important crops, and benoxacor is a safening compound able to induce the enzymatic mechanism of chloroacetanilide detoxification in plants. A practical method for a simultaneous detection of butachlor and benoxacor residues in wheat and in soil is described. The procedure can be performed by GC and HPLC. They were extracted with methanol and cleaned up by solid phase extraction (SPE). The analytes were satisfactorily separated via both GC and HPLC techniques, and no interferences were observed coming from plant or soil matrixes or reagents. The limit of quantitation was found to be 5.0 ng by GC and 20.0 ng by HPLC for butachlor and 2.5 ng by GC and 15.0 ng by HPLC for benoxacor. Butachlor recovery tests ranged from 85.4% to 91.7% in wheat shoots and 84.0% to 93.2% in soil; benoxacor recovery tests ranged from 86.5% to 90.8% in wheat shoots and 85.7% to 90.7% in soil. The reproducibility and the accuracy make this method a selective and sensitive tool for routine analyses.  相似文献   

18.
A method has been developed for the extraction of capsaicinoids from peppers by pressurized liquid extraction (PLE); these compounds are determined by reverse phase high-performance liquid chromatography (HPLC), with detection by fluorescence spectrophotometry and mass spectrometry (MS). The stability of capsaicin and dihydrocapsaicin has been studied at different temperatures (50-200 degrees C), and several extraction variables have been assayed: solvent (methanol, ethanol, and water), different percentages of water in the methanol (0-20%) and in the ethanol (0-20%), and the number of extraction cycles. The study has evaluated the repeatability (RSD < 7%) and the reproducibility (RSD < 7%) of the method. Finally, the PLE method developed has been applied to quantify the capsaicinoids present in three varieties of hot peppers cultivated in Spain, quantifying five capsaicinoids: nordihydrocapsaicin, capsaicin, dihydrocapsaicin, an isomer of dihydrocapsaicin, and homodihydrocapsaicin.  相似文献   

19.
A reliable, rapid, and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of chloramphenicol and aflatoxin M(1) in milk has been developed. This method includes simple extraction of sample with acetonitrile, separation on a MGIII-C(18) column using 5 mM ammonium acetate aqueous solution/methanol (60:40, v/v) as mobile phase, and MS/MS detection using multiple reaction monitoring mode. The method was validated according to Commission Decision 2002/657/EC. The limits of detection (LODs) were 0.05 μg/kg for chloramphenicol and 0.005 μg/kg for aflatoxin M(1.) The limits of quantification (LOQs) were 0.2 μg/kg for chloramphenicol and 0.02 μg/kg for aflatoxin M(1). The recovery values ranged from 88.8% to 100.6%, with relative standard deviation lower than 15% in all cases, when samples were fortified at three different concentrations. The decision limits (CCα) and detection capability (CCβ) of the method were also reported. This method has been successfully applied for simultaneous analysis of chloramphenicol and aflatoxin M(1) residues in milk from local supermarkets in China.  相似文献   

20.
The official methods for the quantification of aflatoxin M1 in dairy products (cheese and yogurt) include extraction into dichloromethane or chloroform, evaporation of the solvent, partitioning of the reconstituted residue with hexane, and subsequent analysis. To secure a rapid and inexpensive screen for aflatoxin M1 contamination, a sensitive competitive ELISA, using a rabbit polyclonal antibody, was developed for measuring aflatoxin M1 in milk and used in a comparative study for measuring the extraction efficiency of aflatoxin M1 in aqueous or organic solvent buffers using yogurt samples. An aqueous sodium citrate solution was found to be suitable for extracting aflatoxin M1, thus eliminating the need for organic solvents. The citrate extraction proved to be efficient (recovery ranged from 70 to 124%) in fortified samples of very different kinds of dairy products, including yogurt and six types of cheese. Fourteen yogurt and cheese samples were extracted with citrate solution and analyzed by ELISA. A good correlation was observed (y=0.95x-0.59, r2=0.98) when the data were compared with those obtained through the official method, across a wide range of aflatoxin M1 contaminations (10-200 ng/kg).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号