首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 843 毫秒
1.
OBJECTIVE: To determine the relationship between bispectral index (BIS) and minimum alveolar concentration (MAC) multiples of isoflurane after IM injection of medetomidine or saline (0.9% NaCl) solution in anesthetized dogs. ANIMALS: 6 dogs. PROCEDURE: Each dog was anesthetized 3 times with isoflurane. First, the MAC of isoflurane for each dog was determined by use of the tail clamp method. Second, anesthetized dogs were randomly assigned to receive an IM injection of medetomidine (8 microg x kg(-1)) or an equal volume of isotonic saline (0.9% NaCl) solution 30 minutes prior to beginning BIS measurements. Last, anesthetized dogs received the remaining treatment (medetomidine or isotonic saline solution). Dogs were anesthetized at each of 4 MAC multiples of isoflurane. Ventilation was controlled and atracurium (0.2 mg/kg followed by 6 microg/kg/min as a continuous infusion, IV) administered. After a 20-minute equilibration period at each MAC multiple of isoflurane, BIS data were collected for 5 minutes and median values of BIS calculated. RESULTS: BIS significantly decreased with increasing MAC multiples of isoflurane over the range of 0.8 to 2.0 MAC. Mean (+/- SD) MAC of isoflurane was 1.3 +/- 0.2%. During isoflurane-saline anesthesia, mean BIS measurements at 0.8, 1.0, 1.5, and 2.0 MAC were 65 +/- 8, 60 +/- 7 52 +/- 3, and 31 +/- 28, respectively. During isoflurane-medetomidine anesthesia, mean BIS measurements at 0.8, 1.0, 1.5, and 2.0 MAC were 77 +/- 4, 53 +/- 7, 31 +/- 24, and 9 +/- 20, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: BIS monitoring in dogs anesthetized with isoflurane has a predictive value in regard to degree of CNS depression. During isoflurane anesthesia, our results support a MAC-reducing effect of medetomidine.  相似文献   

2.
The relationships between bispectral index (BIS), cardiovascular variables and minimum alveolar concentration (MAC) multiples of sevoflurane in puppies were determined. Five puppies were anesthetized with sevoflurane on two occasions. First, the individual sevoflurane MAC values were determined for each puppy. Secondly, dogs were anesthetized with sevoflurane at each of 5 MAC multiples, 0.75, 1, 1.25, 1.5 and 1.75 MAC administered in random order. Hemodynamic parameters and BIS data were collected for 20 min. Somatic stimulus was then applied and the same parameters and data were collected for 6 min. Correlation between BIS and end tidal sevoflurane and between BIS and hemodynamic parameters were studied. We found positive significant correlation in both cases. BIS is lower in puppies that in adults at the same alveolar anesthetic concentrations and sevoflurane appears to be a safe anesthetic in puppies.  相似文献   

3.
OBJECTIVE: To evaluate the use of a lithium dilution cardiac output (LiDCO) technique for measurement of CO and determine the agreement between LiDCO and thermodilution CO (TDCO) values in anesthetized cats. ANIMALS: 6 mature cats. PROCEDURE: Cardiac output in isoflurane-anesthetized cats was measured via each technique. To induce different rates of CO in each cat, anesthesia was maintained at > 1.5X end-tidal minimum alveolar concentration (MAC) of isoflurane and at 1.3X end-tidal isoflurane MAC with or without administration of dobutamine (1 to 3 microg/kg/min, i.v.). At least 2 comparisons between LiDCO and TDCO values were made at each CO rate. The TDCO indicator was 1.5 mL of 5% dextrose at room temperature; with the LiDCO technique, each cat received 0.005 mmol of lithium/kg (concentration, 0.015 mmol/mL). Serum lithium concentrations were measured prior to the first and following the last CO determination. RESULTS: 35 of 47 recorded comparisons were analyzed; via linear regression analysis (LiDCO vs TDCO values), the coefficient of determination was 0.91. The mean bias (TDCO-LiDCO) was -4 mL/kg/min (limits of agreement, -35.8 to + 27.2 mL/kg/min). The concordance coefficient was 0.94. After the last CO determination, serum lithium concentration was < 0.1 mmol/L in each cat. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated a strong relationship and good agreement between LiDCO and TDCO values; the LiDCO method appears to be a practical, relatively noninvasive method for measurement of CO in anesthetized cats.  相似文献   

4.
OBJECTIVE: To quantitate effects of dose of sevoflurane and mode of ventilation on cardiovascular and respiratory function in horses and identify changes in serum biochemical values associated with sevoflurane anesthesia. ANIMALS: 6 healthy adult horses. PROCEDURE: Horses were anesthetized twice: first, to determine the minimum alveolar concentration (MAC) of sevoflurane and second, to characterize cardiopulmonary and serum biochemical responses of horses to 1.0, 1.5, and 1.75 MAC multiples of sevoflurane during controlled and spontaneous ventilation. Results-Mean (+/- SEM) MAC of sevoflurane was 2.84 +/- 0.16%. Cardiovascular performance during anesthesia decreased as sevoflurane increased; the magnitude of cardiovascular depression was more severe during mechanical ventilation, compared with spontaneous ventilation. Serum inorganic fluoride concentration increased to a peak of 50.8 +/- 7.1 micromol/L at the end of anesthesia. Serum creatinine concentration and sorbitol dehydrogenase activity reached their greatest values (2.0 +/- 0.8 mg/dL and 10.2 +/- 1.8 U/L, respectively) at 1 hour after anesthesia and then returned to baseline by 1 day after anesthesia. Serum creatine kinase, aspartate aminotransferase, and alkaline phosphatase activities reached peak values by the first (ie, creatine kinase) or second (ie, aspartate aminotransferase and alkaline phosphatase) day after anesthesia. CONCLUSIONS AND CLINICAL RELEVANCE: Sevoflurane causes dose-related cardiopulmonary depression, and mode of ventilation further impacts the magnitude of this depression. Except for serum inorganic fluoride concentration, quantitative alterations in serum biochemical indices of liver- and muscle-cell disruption and kidney function were considered clinically unremarkable and similar to results from comparable studies of other inhalation anesthetics.  相似文献   

5.
OBJECTIVE: To characterize halothane and sevoflurane anesthesia in spontaneously breathing rats. ANIMALS: 16 healthy male Sprague-Dawley rats. PROCEDURE: 8 rats were anesthetized with halothane and 8 with sevoflurane. Minimum alveolar concentration (MAC) was determined. Variables were recorded at anesthetic concentrations of 0.8, 1.0, 1.25, and 1.5 times the MAC of halothane and 1.0, 1.25, 1.5, and 1.75 times the MAC of sevoflurane. RESULTS: Mean (+/- SEM) MAC for halothane was 1.02 +/- 0.02% and for sevoflurane was 2.99 +/- 0.19%. As sevoflurane dose increased from 1.0 to 1.75 MAC, mean arterial pressure (MAP) decreased from 103.1 +/- 5.3 to 67.9 +/- 4.6 mm Hg, and PaCO2 increased from 58.8 +/- 3.1 to 92.2 +/- 9.2 mm Hg. As halothane dose increased from 0.8 to 1.5 MAC, MAP decreased from 99 +/- 6.2 to 69.8 +/- 4.5 mm Hg, and PaCO2 increased from 59.1 +/- 2.1 to 75.9 +/- 5.2 mm Hg. Respiratory rate decreased in a dose-dependent fashion from 88.5 +/- 4.5 to 58.5 +/- 2.7 breaths/min during halothane anesthesia and from 42.3 +/- 1.8 to 30.5 +/- 4.5 breaths/min during sevoflurane anesthesia. Both groups of rats had an increase in eyelid and pupillary aperture with an increase in anesthetic dose. CONCLUSIONS AND CLINICAL RELEVANCE: An increase in PaCO2 and a decrease in MAP are clinical indicators of an increasing halothane and sevoflurane dose in unstimulated spontaneously breathing rats. Increases in eyelid aperture and pupil diameter are reliable signs of increasing depth of halothane and sevoflurane anesthesia. Decreasing respiratory rate is a clinical indicator of an increasing dose of halothane.  相似文献   

6.
OBJECTIVE: To determine the effect of inhalation of isoflurane at end-tidal concentrations greater than, equal to, and less than the minimum anesthetic concentration (MAC) on bispectral index (BIS) in chickens. Animals-10 chickens. PROCEDURES: For each chicken, the individual MAC of isoflurane was determined by use of the toe-pinch method. After a 1-week interval, chickens were anesthetized with isoflurane at concentrations 1.75, 1.50, 1.25, 1.00, and 0.75 times their individual MAC (administered from higher to lower concentrations). At each MAC multiple, a toe pinch was performed and BIS was assessed and correlated with heart rate, blood pressure, and an awareness score (derived by use of a visual analogue scale). RESULTS: Among the chickens, mean +/- SD MAC of isoflurane was 1.15 +/- 0.20%. Burst suppression was detected at every MAC multiple. The BIS and awareness score were correlated directly with each other and changed inversely with increasing isoflurane concentration. Median (range) BIS values during anesthesia at 1.75, 1.50, 1.25, 1.00, and 0.75 MAC of isoflurane were 25 (15 to 35), 35 (25 to 45), 35 (20 to 50), 40 (25 to 55), and 50 (35 to 65), respectively. Median BIS value at extubation was 70 +/- 9. Values of BIS correlated with blood pressure, but not with heart rate. Blood pressure changed with end-tidal isoflurane concentrations, whereas heart rate did not. CONCLUSIONS AND CLINICAL RELEVANCE: Assessment of BIS can be used to monitor the electrical activity of the brain and the degree of unconsciousness in chickens during isoflurane anesthesia.  相似文献   

7.
OBJECTIVE: To compare the minimum alveolar concentration (MAC) of isoflurane required to prevent corticocerebral activation, autonomic responses, and purposeful movements after somatic or visceral stimulation in cats anesthetized with isoflurane. ANIMALS: 17 healthy spayed female cats. PROCEDURE: Bispectral index (BIS), autonomic parameters, and purposeful movements were monitored before and after somatic or visceral stimuli in cats anesthetized with isoflurane. End-tidal (ET) isoflurane concentration was varied to determine MAC values for cortical arousal (MAC(BIS)), autonomic responsiveness (MAC(BAR)), and purposeful movement (MAC). Bispectral index values > or = 60 were considered to represent corticocerebral activation. RESULTS: Minimum alveolar concentration for purposeful movement was significantly less than MAC(BIS) and MAC(BAR) for both somatic and visceral stimulation. Individual MAC values for somatic stimulation were not significantly different from respective MAC values for visceral stimulation. The percentage of cats that had a BIS response > or = 60 was inversely related to the end-tidal isoflurane concentration. CONCLUSIONS AND CLINICAL RELEVANCE: Corticocerebral arousal and subcortical autonomic reflexes occured at isoflurane anesthetic concentrations at which reflexive or purposeful movements were absent. These results suggested that isoflurane had a preferential effect on voluntary motor output at low end-tidal isoflurane concentrations, and that sensory pathways, subcortical sympathetic output, and cortical responsiveness are less susceptible to the anesthetic effects of isoflurane. Bispectral index values obtained after somatic or visceral stimulation were sensitive for the detection of early changes in cortical excitability.  相似文献   

8.
OBJECTIVE: To evaluate bispectral index (BIS), spectral edge frequency 95% (SEF), and median frequency (MED) in relation to a visual analogue scale (VAS) as indicators of anesthetic depth for various concentrations of sevoflurane and isoflurane in pigs. ANIMALS: 32 pigs. PROCEDURE: Pigs were randomly allocated to 8 groups (4 pigs/group). An electroencephalogram (EEG) was recorded in each conscious pig. Pigs were then anesthetized by use of sevoflurane (n = 16) or isoflurane (16). Agents were administered in oxygen at minimum alveolar concentrations (MACs) of 1, 1.25, 1.5, and 1.75 MAC in a randomized order. End-tidal sevoflurane and isoflurane concentrations were maintained for 30 minutes, after which an EEG was recorded for 5 minutes; BIS, SEF, and MED were then calculated. Anesthetic depth was evaluated by use of the VAS. Cardiovascular and EEG responses to nociceptive stimuli were evaluated for each anesthetic agent. RESULTS: BIS decreased significantly for the various concentrations of each anesthetic. At equivalent MACs, BIS values were significantly higher during sevoflurane-induced anesthesia than during isoflurane-induced anesthesia. Values of MED and SEF decreased significantly from basal values to 1 MAC of sevoflurane and isoflurane. For both agents, there was good correlation between VAS scores and BIS values and between VAS scores and SEF values. CONCLUSIONS AND CLINICAL RELEVANCE: BIS was useful for predicting changes in anesthetic depth at clinical dosages of inhalant anesthetics. Values of BIS, SEF, and MED were significantly higher during anesthesia induced by administration of sevoflurane than during anesthesia induced by administration of isoflurance at equivalent MACs.  相似文献   

9.
OBJECTIVE: To determine the effects of constant rate infusion of morphine, lidocaine, ketamine, and morphine-lidocaine-ketamine (MLK) combination on end-tidal isoflurane concentration (ET-Iso) and minimum alveolar concentration (MAC) in dogs anesthetized with isoflurane and monitor depth of anesthesia by use of the bispectral index (BIS). ANIMALS: 6 adult dogs. PROCEDURE: Each dog was anesthetized with isoflurane on 5 occasions, separated by a minimum of 7 to 10 days. Individual isoflurane MAC values were determined for each dog. Reduction in isoflurane MAC, induced by administration of morphine (3.3 microg/kg/min), lidocaine (50 microg/kg/min), ketamine (10 microg/kg/min), and MLK, was determined. Heart rate, mean arterial blood pressure, oxygen saturation as measured by pulse oximetry (Spo2), core body temperature, and BIS were monitored. RESULTS: Mean +/- SD isoflurane MAC was 1.38 +/- 0.08%. Morphine, lidocaine, ketamine, and MLK significantly lowered isoflurane MAC by 48, 29, 25, and 45%, respectively. The percentage reductions in isoflurane MAC for morphine and MLK were not significantly different but were significantly greater than for lidocaine and ketamine. The Spo2, mean arterial pressure, and core body temperature were not different among groups. Heart rate was significantly decreased at isoflurane MAC during infusion of morphine and MLK. The BIS was inversely related to the ET-Iso and was significantly increased at isoflurane MAC during infusions of morphine and ketamine, compared with isoflurane alone. CONCLUSIONS AND CLINICAL RELEVANCE: Low infusion doses of morphine, lidocaine, ketamine, and MLK decreased isoflurane MAC in dogs and were not associated with adverse hemodynamic effects. The BIS can be used to monitor depth of anesthesia.  相似文献   

10.
OBJECTIVE: To determine induction characteristics and the minimum alveolar concentration (MAC) at which consciousness returned (MACawake) in dogs anesthetized with isoflurane or sevoflurane. ANIMALS: 20 sexually intact male Beagles. PROCEDURES: In experiment 1, 20 dogs were randomly assigned to have anesthesia induced and maintained with isoflurane or sevoflurane. The MAC at which each dog awoke in response to auditory stimulation (MACawake-noise) was determined by decreasing the end-tidal concentration by 0.1 volume (vol %) every 15 minutes and delivering a standard audible stimulus at each concentration until the dog awoke. In experiment 2, 12 dogs received the same anesthetic agent they were administered in experiment 1. After duplicate MAC determination, the end-tidal concentration was continually decreased by 10% every 15 minutes until the dog awoke from anesthesia (MACawake). RESULTS: Mean induction time was significantly greater for isoflurane-anesthetized dogs (212 seconds), compared with the sevoflurane-anesthetized dogs (154 seconds). Mean+/-SD MACawake-noise was 1.1+/-0.1 vol % for isoflurane and 2.0+/-0.2 vol % for sevoflurane. Mean MAC was 1.3+/-0.2 vol % for isoflurane and 2.1+/-0.6 vol % for sevoflurane, and mean MACawake was 1.0+/-0.1 vol % for isoflurane and 1.3+/-0.3 vol % for sevoflurane. CONCLUSIONS AND CLINICAL RELEVANCE: Sevoflurane resulted in a more rapid induction than did isoflurane. The MACawake for dogs was higher than values reported for both agents in humans. Care should be taken to ensure that dogs are at an appropriate anesthetic depth to prevent consciousness, particularly when single-agent inhalant anesthesia is used.  相似文献   

11.
OBJECTIVE: To compare the effects of acupuncture (AP), electroacupuncture (EA), and transcutaneous cranial electrical stimulation (TCES) with high-frequency intermittent currents on the minimum alveolar concentration (MAC) of isoflurane and associated cardiovascular variables in dogs. ANIMALS: 8 healthy adult female Beagles. PROCEDURE: Each dog was anesthetized with isoflurane on 4 occasions, allowing a minimum of 10 days between experiments. Isoflurane MAC values were determined for each dog without treatment (controls) and after treatment with AP and EA (AP points included the Large Intestine 4, Lung 7, Governing Vessel 20, Governing Vessel 14, San Tai, and Baihui) and TCES. Isoflurane MAC values were determined by use of noxious electrical buccal stimulation. Heart rate, mean arterial blood pressure (MAP), arterial blood oxygen saturation (Spo2) measured by use of pulse oximetry, esophageal body temperature, inspired and expired end-tidal isoflurane concentrations, end-tidal carbon dioxide concentration, and bispectral index (BIS) were monitored. Blood samples were collected for determination of plasma cortisol concentration. RESULTS: Mean +/- SD baseline MAC of isoflurane was 1.19 +/- 0.1%. Acupuncture did not significantly change MAC of isoflurane. Treatments with EA and TCES significantly lowered the MAC of isoflurane by 10.1% and 13.4%, respectively. The Spo2, heart rate, MAP, BIS, esophageal body temperature, and plasma cortisol concentration were not significantly different after AP, EA, TCES, and control treatments at any time interval. CONCLUSIONS AND CLINICAL RELEVANCE: Use of EA and TCES decreased MAC of isoflurane in dogs without inducing adverse hemodynamic effects. However, the reduction in isoflurane MAC by EA andTCES treatments was not considered clinically relevant.  相似文献   

12.
OBJECTIVE: To determine whether opioids with varying interactions at receptors induce a reduction in minimum alveolar concentration (MAC) of isoflurane in cats. ANIMALS: 12 healthy, female, spayed cats. PROCEDURE: Cats were anesthetized with isoflurane and instrumented to allow collection of arterial blood and measurement of arterial blood pressure. Each drug was studied separately, and for each drug cats were randomly allocated to receive 2 doses. The drugs studied were morphine (0.1 or 1.0 mg/kg), butorphanol (0.08 or 0.8 mg/kg), buprenorphine (0.005 and 0.05 mg/kg), and U50488H (0.02 and 0.2 mg/kg). All drugs were diluted in 5 ml of saline (0.9% NaCl) solution and infused IV for 5 minutes. The MAC of isoflurane was determined in triplicate, the drug administered, and the MAC of isoflurane redetermined for a period of 3 hours. RESULTS: All drugs had a significant effect on MAC over time. With morphine only, the effect on MAC over time was different between doses. The greatest mean (+/- SD) reductions in MAC of isoflurane in response to morphine, butorphanol, buprenorphine, and U50488H administration were 28 +/- 9, 19 +/- 3, 14 +/- 7, and 11 +/- 7%, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: Morphine (1.0 mg/kg) and butorphanol (0.08 and 0.8 mg/kg) induced significant reductions in MAC of isoflurane that were considered clinically important. Although significant, reductions in MAC of isoflurane induced by morphine (0.1 mg/kg), buprenorphine (0.005 and 0.05 mg/kg), and U50488H (0.02 and 0.2 mg/kg) were not considered clinically relevant because they fell within the error of the measurement technique. Administration of morphine or butorphanol decreases the need for potent inhalant anesthetics in cats and could potentially be beneficial in combination with inhalants.  相似文献   

13.
OBJECTIVE: To determine the minimum alveolar concentration (MAC) of sevoflurane in spontaneously breathing llamas and alpacas. DESIGN: Prospective study. ANIMALS: 6 healthy adult llamas and 6 healthy adult alpacas. PROCEDURE: Anesthesia was induced with sevoflurane delivered with oxygen through a mask. An endotracheal tube was inserted, and a port for continuous measurement of end-tidal and inspired sevoflurane concentrations was placed between the endotracheal tube and the breathing circuit. After equilibration at an end-tidal-to-inspired sevoflurane concentration ratio > 0.90 for 15 minutes, a 50-Hz, 80-mA electrical stimulus was applied to the antebrachium until a response was obtained (ie, gross purposeful movement) or for up to 1 minute. The vaporizer setting was increased or decreased to effect a 10 to 20% change in end-tidal sevoflurane concentration, and equilibration and stimulus were repeated. The MAC was defined as the mean of the lowest end-tidal sevoflurane concentration that prevented a positive response and the highest concentration that allowed a positive response. RESULTS: Mean +/- SD MAC of sevoflurane was 2.29 +/- 0.14% in llamas and 2.33 +/- 0.09% in alpacas. CONCLUSIONS AND CLINICAL RELEVANCE: The MAC of sevoflurane in llamas and alpacas was similar to that reported for other species.  相似文献   

14.
OBJECTIVE: To determine the minimum anesthetic concentration for sevoflurane and effects of various multiples of minimum anesthetic concentration on arterial pressure and heart rate during controlled ventilation in chickens. STUDY DESIGN: Prospective experimental study. ANIMALS: Seven healthy chickens, 6 to 8 months old, weighing 1.6 to 3.4 kg. METHODS: A rebreathing, semiclosed anesthetic circuit was used. Anesthesia was induced by mask with sevoflurane in oxygen. Each chicken was endotracheally intubated, then controlled ventilation was started and the end-tidal CO2 partial pressure was maintained at 30 to 40 mm Hg. Body temperature was maintained at 39.5 degrees to 41.0 degrees C. The inspired and end-tidal sevoflurane concentration were monitored with a multigas monitor. Minimum anesthetic concentration was determined as the minimal end-tidal sevoflurane concentration which prevented gross purposeful movement in response to clamping a toe for 1 minute. After the determination, the cardiovascular effects of sevoflurane at 1.0, 1.5, and 2.0 times the minimum anesthetic concentration were determined. RESULTS: The minimum anesthetic concentration for sevoflurane was 2.21% + 0.32% (mean +/- SD). Mean arterial pressure and heart rate at minimum anesthetic concentration were 84 +/- 13 mm Hg and 150 +/- 58 beats/min, respectively. There was a dose-dependent decrease in arterial pressure. The heart rate did not change significantly over the range 1 to 2 x minimum anesthetic concentration. No cardiac arrhythmias developed throughout the experiments. CONCLUSIONS AND CLINICAL RELEVANCE: The minimum anesthetic concentration for sevoflurane in chickens was within the range of minimum alveolar concentration reported in mammals. When the concentration of sevoflurane is increased during controlled ventilation in chickens, decrease in arterial pressure should be expected.  相似文献   

15.
OBJECTIVE: To compare the anesthetic index of sevoflurane with that of isoflurane in unpremedicated dogs. DESIGN: Randomized complete-block crossover design. ANIMALS: 8 healthy adult dogs. PROCEDURE: Anesthesia was induced by administering sevoflurane or isoflurane through a face mask. Time to intubation was recorded. After induction of anesthesia, minimal alveolar concentration (MAC) was determined with a tail clamp method while dogs were mechanically ventilated. Apneic concentration was determined while dogs were breathing spontaneously by increasing the anesthetic concentration until dogs became apneic. Anesthetic index was calculated as apneic concentration divided by MAC. RESULTS: Anesthetic index of sevoflurane (mean +/- SEM, 3.45 +/- 0.22) was significantly higher than that of isoflurane (2.61 +/- 0.14). No clinically important differences in heart rate; systolic, mean, and diastolic blood pressures; oxygen saturation; and respiratory rate were detected when dogs were anesthetized with sevoflurane versus isoflurane. There was a significant linear trend toward lower values for end-tidal partial pressure of carbon dioxide during anesthesia with sevoflurane, compared with isoflurane, at increasing equipotent anesthetic doses. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that sevoflurane has a higher anesthetic index in dogs than isoflurane. Sevoflurane and isoflurane caused similar dose-related cardiovascular depression, but although both agents caused dose-related respiratory depression, sevoflurane caused less respiratory depression at higher equipotent anesthetic doses.  相似文献   

16.
The anesthetic potency and cardiopulmonary effects of sevoflurane were compared with those of isoflurane and halothane in goats. The (mean +/- SD) minimal alveolar concentration (MAC) was 0.96 +/- 0.12% for halothane, 1.29 +/- 0.11% for isoflurane, and 2.33 +/- 0.15% for sevoflurane. Cardiopulmonary effects of sevoflurane, halothane and isoflurane were examined at end-tidal concentrations equivalent to 1, 1.5 and 2 MAC during either spontaneous or controlled ventilation (SV or CV). During SV, there were no significant differences in respiration rate, tidal volume and minute ventilation between anesthetics. Dose-dependent decreases in both tidal volume and minute ventilation induced by halothane were greater than those by either sevoflurane or isoflurane. Hypercapnia and acidosis induced by sevoflurane were not significantly different from those by either isoflurane or halothane at 1 and 1.5 MAC, but were less than those by halothane at 2 MAC. There was no significant difference in heart rate between anesthetics during SV and CV. During SV, all anesthetics induced dose-dependent decreases in arterial pressure, rate pressure product, systemic vascular resistance, left ventricular minute work index and left ventricular stroke work index. Systemic vascular resistance with isoflurane at 2 MAC was lower than that with sevoflurane. During CV, sevoflurane induced dose-dependent circulatory depression (decreases in arterial pressure, cardiac index, rate pressure product, systemic vascular resistance, left ventricular minute work index and right ventricular minute work index), similar to isoflurane. Halothane did not significantly alter systemic vascular resistance from 1 to 2 MAC.  相似文献   

17.
OBJECTIVE: To determine the median effective dose (ED(50); equivalent to the minimum alveolar concentration [MAC]) of isoflurane, sevoflurane, and desflurane for anesthesia in iguanas. ANIMALS: 6 healthy adult green iguanas. PROCEDURE: In unmedicated iguanas, anesthesia was induced and maintained with each of the 3 volatile drugs administered on separate days according to a Latin square design. Iguanas were endotracheally intubated, mechanically ventilated, and instrumented for cardiovascular and respiratory measurements. During each period of anesthesia, MAC was determined in triplicate. The mean value of 2 consecutive expired anesthetic concentrations, 1 that just permitted and 1 that just prevented gross purposeful movement in response to supramaximal electrical stimulus, and that were not different by more than 15%, was deemed the MAC. RESULTS: Mean +/- SD values for the third MAC determination for isoflurane, sevoflurane, and desflurane were 1.8 +/- 0.3%, 3.1 +/- 1.0%, and 8.9 +/- 2.1% of atmospheric pressure, respectively. The MAC for all inhaled agents was, on average, 22% greater for the first measurement than for the third measurement. CONCLUSIONS AND CLINICAL RELEVANCE: Over time, MACs decreased for all 3 agents. Final MAC measurements were similar to values reported for other species. The decrease in MACs over time may be at least partly explained by limitations of anesthetic uptake and distribution imposed by the reptilian cardiorespiratory system. Hence, for a constant end-tidal anesthetic concentration in an iguana, the plane of anesthesia may deepen over time, which could contribute to increased morbidity during prolonged procedures.  相似文献   

18.
The purpose of this study was to investigate the effects of sevoflurane concentration on canine visual evoked potentials with pattern stimulation (P-VEPs). Six clinically normal laboratory-beagle dogs were used. The minimum alveolar concentration (MAC) of sevoflurane was detected from all subjects by tail clamp method. The refractive power of the right eyes of all subjects was corrected to −2 diopters after skiascopy. For P-VEP recording, the recording and reference electrode were positioned at inion and nasion, respectively, and the earth electrode was positioned on the inner surface. To grasp the state of CNS suppression objectively, the bispectral index (BIS) value was used. The stimulus pattern size and distance for VEP recording were constant, 50.3 arc-min and 50 cm, respectively. P-VEPs and BIS values were recorded under sevoflurane in oxygen inhalational anesthesia at 0.5, 1.0, 1.5, 2.0, 2.5 and 2.75 sevoflurane MAC. For analysis of P-VEP, the P100 implicit time and N75-P100 amplitude were estimated. P-VEPs were detected at 0.5 to 1.5 MAC in all dogs, and disappeared at 2.0 MAC in four dogs and at 2.5 and 2.75 MAC in one dog each. The BIS value decreased with increasing sevoflurane MAC, and burst suppression began to appear from 1.5 MAC. There was no significant change in P100 implicit time and N75-P100 amplitude with any concentration of sevoflurane. At concentrations around 1.5 MAC, which are used routinely to immobilize dogs, sevoflurane showed no effect on P-VEP.  相似文献   

19.
OBJECTIVE-To compare the effect of oral administration of tramadol alone and with IV administration of butorphanol or hydromorphone on the minimum alveolar concentration (MAC) of sevoflurane in cats. DESIGN-Crossover study. ANIMALS-8 Healthy 3-year-old cats. PROCEDURES-Cats were anesthetized with sevoflurane in 100% oxygen. A standard tail clamp method was used to determine the MAC of sevoflurane following administration of tramadol (8.6 to 11.6 mg/kg [3.6 to 5.3 mg/lb], PO, 5 minutes before induction of anesthesia), butorphanol (0.4 mg/kg [0.18 mg/lb], IV, 30 minutes after induction), hydromorphone (0.1 mg/kg [0.04 mg/lb], IV, 30 minutes after induction), saline (0.9% NaCl) solution (0.05 mL/kg [0.023 mL/lb], IV, 30 minutes after induction), or tramadol with butorphanol or with hydromorphone (same doses and routes of administration). Naloxone (0.02 mg/kg [0.009 mg/lb], IV) was used to reverse the effects of treatments, and MACs were redetermined. RESULTS-Mean +/- SEM MACs for sevoflurane after administration of tramadol (1.48 +/- 0.20%), butorphanol (1.20 +/- 0.16%), hydromorphone (1.76 +/- 0.15%), tramadol and butorphanol (1.48 +/- 0.20%), and tramadol and hydromorphone (1.85 +/- 0.20%) were significantly less than those after administration of saline solution (2.45 +/- 0.22%). Naloxone reversed the reductions in MACs. CONCLUSIONS AND CLINICAL RELEVANCE-Administration of tramadol, butorphanol, or hydromorphone reduced the MAC of sevoflurane in cats, compared with that in cats treated with saline solution. The reductions detected were likely mediated by effects of the drugs on opioid receptors. An additional reduction in MAC was not detected when tramadol was administered with butorphanol or hydromorphone.  相似文献   

20.
OBJECTIVE: To evaluate bispectral index (BIS) values in pigs during anesthesia maintained with sevoflurane-fentanyl or propofol-fentanyl as a predictor of changes in hemodynamic parameters and duration of recovery from anesthesia. ANIMALS: 12 pigs. PROCEDURE: Pigs were randomly allocated to undergo 1 of 2 anesthetic regimens. Anesthesia was induced with propofol (2 mg/kg, i.v.); 6 pigs were administered sevoflurane via inhalation (1 minimum alveolar concentration [MAC] at a fresh gas flow rate of 3 L/min; group I), and 6 were administered propofol (11 mg/kg/h, i.v.; group II). All pigs received fentanyl (2.5 mg/kg, i.v., q 30 min). After abdominal surgery, pigs were allowed to recover from anesthesia. Cardiovascular variables and BIS values were recorded at intervals throughout the procedure; duration of recovery from anesthesia was noted. RESULTS: No correlation was established between arterial blood pressure and BIS and between heart rate and BIS. Mean BIS at discontinuation of administration of the anesthetic agent was greater in group-II pigs (65.2 +/- 10.6 minutes) than in group-I pigs (55.8 +/- 2.9 minutes). However, recovery from anesthesia was significantly longer in group II (59.80 +/- 2.52 minutes) than in group I (9.80 +/- 2.35 minutes). CONCLUSIONS AND CLINICAL RELEVANCE: In swine anesthetized with sevoflurane or propofol and undergoing abdominal surgery, the BIS value derived from an electroencephalogram at the end of anesthesia was not useful for predicting the speed of recovery from anesthesia. Moreover, BIS was not useful as a predictor of clinically important changes in arterial blood pressure and heart rate in those anesthetized pigs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号