 共查询到20条相似文献,搜索用时 13 毫秒
1.
Objective To evaluate the effect of central corneal thickness (CCT) on the measurement of intraocular pressure (IOP) with the rebound (TonoVet®) and applanation (TonoPen XL®) tonometers in beagle dogs. Animal studied Both eyes of 60 clinically normal dogs were used. Procedures The IOP was measured by the TonoVet®, followed by the TonoPen XL® in half of the dogs, while the other half was measured in the reverse order. All CCT measurements were performed 10 min after the use of the second tonometer. Results The mean IOP value measured by the TonoVet® (16.9 ± 3.7 mmHg) was significantly higher than the TonoPen XL® (11.6 ± 2.7 mmHg; P < 0.001). The IOP values obtained by both tonometers were correlated in the regression analysis (γ2 = 0.4393, P < 0.001). Bland–Altman analysis showed that the lower and upper limits of agreement between the two devices were ?0.1 and +10.8 mmHg, respectively. The mean CCT was 549.7 ± 51.0 μm. There was a correlation between the IOP values obtained by the two tonometers and CCT readings in the regression analysis (TonoVet® : P = 0.002, TonoPen XL® : P = 0.035). The regression equation demonstrated that for every 100 μm increase in CCT, there was an elevation of 1 and 2 mmHg in IOP measured by the TonoPen XL® and TonoVet®, respectively. Conclusions The IOP obtained by the TonoVet® and TonoPen XL® would be affected by variations in the CCT. Therefore, the CCT should be considered when interpreting IOP values measured by tonometers in dogs.  相似文献   

2.
3.
Objective  To evaluate and to validate the accuracy of the Perkins® handheld applanation tonometer in the measurement of IOP in dogs and cats.
Animals  Twenty eyes from 10 dogs and 10 cats immediately after sacrifice were used for the postmortem study and 20 eyes from 10 clinically normal and anesthetized dogs and cats were used for the in vivo study. Both eyes of 20 conscious dogs and cats were also evaluated.
Procedure  Readings of IOP postmortem and in vivo were taken using manometry (measured with a mercury column manometer) and tonometry (measured with a Perkins® handheld applanation tonometer). The IOP measurement with Perkins® tonometer in anesthetized and conscious dogs and cats was accomplished by instillation of proxymetacaine 0.5% and of 1% fluorescein eye drops.
Results  The correlation coefficient ( r 2) between the manometry and the Perkins® tonometer were 0.982 (dogs) and 0.988 (cats), and the corresponding linear regression equation were y  = 0.0893 x  + 0.1105 (dogs) and y  = 0.0899 x  + 0.1145 (cats) in the postmortem study. The mean IOP readings with the Perkins® tonometer after calibration curve correction were 14.9 ± 1.6 mmHg (range 12.2–17.2 mmHg) in conscious dogs, and were 15.1 ± 1.7 mmHg (range 12.1–18.7 mmHg) in conscious cats.
Conclusion  There was an excellent correlation between the IOP values obtained from direct ocular manometry and the Perkins® tonometer in dogs and cats. The Perkins® handheld tonometer could be in the future a new alternative for the diagnosis of glaucoma in veterinary ophthalmology.  相似文献   

4.
5.

Objective

The objectives of the study were to compare intraocular pressure (IOP) readings across a wide range and obtained via three rebound tonometers in ADAMTS10-mutant Beagle-derived dogs with different stages of open-angle glaucoma (OAG) and normal control dogs and to investigate the effect of central corneal thickness (CCT).

Animals Studied

Measurements were performed on 99 eyes from 50 Beagle-derived dogs with variable genetics—16 non-glaucomatous and 34 with ADAMTS10-OAG. Seventeen OAG eyes were measured twice—with and without the use of IOP-lowering medications.

Procedures

IOP was measured in each eye using three tonometers with their “dog” setting—ICare® Tonovet (TV), ICare® Tonovet Plus® (TVP), and the novel Reichert® Tono-Vera® Vet (TVA)—in randomized order. CCT was measured with the Accutome® PachPen. Statistical analyses included one-way ANOVA, Tukey pairwise comparisons, and regression analyses of tonometer readings and pairwise IOP-CCT Pearson correlations (MiniTab®).

Results

A total of 116 IOP measurements were taken with each of the three tonometers. When comparing readings over a range of ~7–77 mmHg, mean IOPs from the TV were significantly lower compared with TVP (−4.6 mmHg, p < .001) and TVA (−3.7 mmHg, p = .001). We found no significant differences between TVA and TVP measurements (p = .695). There was a moderate positive correlation between CCT and IOP for TVA (r = 0.53, p < .001), TVP (r = 0.48, p < .001), and TV (r = 0.47, p < .001).

Conclusions

Our data demonstrate strong agreement between TVP and TVA, suggesting that the TVA may similarly reflect true IOP values in canines. CCT influenced IOP measurements of all three tonometers.  相似文献   

6.
OBJECTIVE: To examine the feasibility and accuracy of a handheld rebound tonometer, TonoVet, and to compare the intraocular pressure (IOP) readings of the TonoVet with those of an applanation tonometer, TonoPen XL, in normal Eurasian Eagle owls. ANIMALS STUDIED: Ten clinically normal Eurasian Eagle owls (20 eyes). PROCEDURES: Complete ocular examinations, using slit-lamp biomicroscopy and indirect ophthalmoscopy, were conducted on each raptor. The IOP was measured bilaterally using a rebound tonometer followed by a topical anesthetic agent after 1 min. The TonoPen XL tonometer was applied in both eyes 30 s following topical anesthesia. RESULTS: The mean +/- SD IOP obtained by rebound tonometer was 10.45 +/- 1.64 mmHg (range 7-14 mmHg), and by applanation tonometer was 9.35 +/- 1.81 mmHg (range 6-12 mmHg). There was a significant difference (P = 0.001) in the IOP obtained from both tonometers. The linear regression equation describing the relationship between both devices was y = 0.669x + 4.194 (x = TonoPen XL and y = TonoVet). The determination coefficient (r(2)) was r(2) = 0.550. CONCLUSIONS: The results suggest that readings from the rebound tonometer significantly overestimated those from the applanation tonometer and that the rebound tonometer was tolerated well because of the rapid and minimal stress-inducing method of tonometry in the Eurasian Eagle owls, even without topical anesthesia. Further studies comparing TonoVet with manometric measurements may be necessary to employ rebound tonometer for routine clinical use in Eurasian Eagle owls.  相似文献   

7.
OBJECTIVE: To establish the central corneal thickness (CCT) of normal koi fish by ultrasonic pachymetry, and its relationship to age, sex, body length and corneal diameter. METHODS: Age, sex and body length of 33 koi fish (17 male and 16 female fish) were recorded. Horizontal and vertical corneal diameters of each eye were obtained using Jameson calipers. Central corneal thickness of all eyes was measured by ultrasonic pachymetry. Intraocular pressure (IOP) by rebound tonometry was obtained for a subgroup of nine koi (18 eyes). RESULTS: Mean central corneal thickness was 325.9 microm. Central corneal thickness of female koi was greater than CCT of male fish (P < 0.01). Central corneal thickness increased with increasing age overall and within both sexes (P < 0.01). Central corneal thickness increased with increasing body length (P < 0.001). For male and female fish, CCT increased with increasing horizontal and vertical corneal diameters (P < 0.01). Mean horizontal corneal diameter (HCD) was 8.05 mm, mean vertical corneal diameter (VCD) was 7.38 mm, and HCD was consistently greater than VCD. Mean IOP of a subgroup of these koi was 4.9 mmHg by rebound tonometry. CONCLUSIONS: Koi CCT increases with increasing age, body length and corneal diameter.  相似文献   

8.
The objective of this study was to evaluate and validate the accuracy of the Perkins handheld applanation tonometer for measuring intraocular pressure (IOP) in horses and cattle. Both eyes of 10 adult horses and cattle were evaluated in a postmortem study. The eyes from 10 clinically normal adult horses and cattle were also examined after bilateral auriculopalpebral nerve block and topical anesthesia for an in vivo study. IOP was measured postmortem using direct manometry (measured with an aneroid manometer) and tonometry (measured with a Perkins handheld applanation tonometer). The correlation coefficients (r2) for the data from the postmortem manometry and Perkins tonometer study were 0.866 for horses and 0.864 for cattle. In the in vivo study, IOP in horses was 25.1 ± 2.9 mmHg (range 19.0~30.0 mmHg) as measured by manometry and 23.4 ± 3.2 mmHg (range 18.6~28.4 mmHg) according to tonometry. In cattle, IOP was found to be 19.7 ± 1.2 mmHg (range 18.0~22.0 mmHg) by manometry and 18.8 ± 1.7 mmHg (range 15.9~20.8 mmHg) by tonometry. There was a strong correlation between the IOP values obtained by direct ocular manometry and the tonometer in both horses and cattle. Our results demonstrate that the Perkins handheld tonometer could be an additional tool for accurately measuring IOP in equine and bovine eyes.  相似文献   

9.
Objective To determine the effect of 0.5% proparacaine in tonometry by evaluating corneal touch threshold (CTT) and intraocular pressure (IOP). Animal studied Nine rats (18 eyes, Sprague–Dawley) and 10 dogs (20 eyes, Beagle) Procedures The IOP and CTT were measured in each eye before and after topical anesthesia with 0.5% proparacaine. The IOP was evaluated using Tonopen for dogs and Tonolab for rats. The corneal sensitivity was evaluated by CTT through a Cochet–Bonnet aesthesiometer. Results The mean IOP was not significantly changed in rats or dogs before and after topical anesthesia. However, after application of proparacaine, CTT was significantly increased in both animal groups compared with that before application of proparacaine. Conclusion From this study, topical anesthesia was found to significantly lower the corneal sensitivity but have little effect on IOP measurements. In ophthalmologic examination, topical anesthesia can be used to reduce corneal sensation without an effect on IOP.  相似文献   

10.
11.
12.
OBJECTIVE: To compare intraocular pressure (IOP) measurements obtained by recently introduced rebound tonometer (ICare) and the well-known applanation tonometer Tonopen XL in normal canine eyes. METHODS: In a prospective, randomized, single-center study, IOP measurements by ICare and Tonopen XL tonometers were compared in 160 nonpathologic canine eyes (80 dogs). Complete slit-lamp biomicroscopy and indirect ophthalmoscopy were performed on each dog. Rebound tonometry was performed first and immediately after topical anesthetic drops were instilled in both eyes. One minute after the application of the topical anesthetic, applanation tonometry was performed in both eyes. The intraocular pressures obtained by use of both techniques were compared by statistical analysis. RESULTS: The mean IOP readings were 9.158 mmHg (SD 3.471 mmHg) for the ICare tonometer (x) and 11.053 mmHg (SD 3.451 mmHg) for the Tonopen XL readings (y). The mean difference in intraocular pressures (-1.905 mmHg) was within clinically acceptable limits. The correlation coefficient (r2) of the relationship within both tonometers was r2=0.7477. The corresponding linear regression between the tonometers readings was y=0.6662x+4.942. CONCLUSIONS: Intraocular pressures obtained with the ICare rebound tonometer were concordant with the IOP readings obtained by applanation Tonopen XL, but ICare values were significantly (P<0.0001) lower. Rebound tonometry could be an appropriate tonometry method for routine clinical use after its calibration for canine eyes.  相似文献   

13.
14.
15.
Objective To compare intraocular pressure (IOP) measurements made on healthy adult rabbits without the effect of tranquilizers using the new applanation tonometer, Tono‐Pen Avia®, and the rebound tonometer Tonovet®. Methods Intraocular pressure was measured throughout the day (6:00, 9:00, 12:00, 15:00, and 18:00 h) in 38 adult New Zealand White rabbits (76 eyes). The animals were 20 males and 18 females, with a mean weight of 3.5 kg and an average age of 6 months. A complete ocular exam (including Schirmer tear test, fluorescein staining, slit‐lamp biomicroscopy, and direct ophthalmoscopy) was performed on all animals at the beginning of the trial. Rebound tonometry was performed, and after 10 min, anesthetic drops were instilled and applanation tonometry was carried out. IOP values obtained using the two techniques were analyzed statistically. Results The mean IOP was 9.51 ± 2.62 mmHg with Tonovet®, and 15.44 ± 2.16 mmHg with the Tono‐Pen Avia®. Significant differences between measurements with the two tonometers were observed (P < 0.001). The linear regression equation describing the relationship between the two tonometers was y = 0.4923x + 10.754 (y = Tonovet® and x = Tono‐Pen Avia®). High IOPs were recorded in the early measurements (6:00), but the average IOPs from both devices were statistically similar throughout the day (P = 0.086). The correlation coefficient was r2 = 0.357. No significant difference in IOP regarding gender was observed. Conclusion The Tono‐Pen Avia® recorded higher levels of IOP compared with the Tonovet®. Early in the day, the IOP of rabbits was higher than later in the day, regardless of the tonometer used.  相似文献   

16.
17.
18.
19.
20.
Objective To determine the practicability and accuracy of central corneal thickness (CCT) measurements in living chicks utilizing a noncontact, high‐speed optical low‐coherence reflectometer (OLCR) mounted on a slit lamp. Animals studied Twelve male chicks (Gallus gallus domesticus). Procedures Measurements of CCT were obtained in triplicate in 24 eyes of twelve 1‐day‐old anaesthetized chicks using OLCR. Every single measurement taken by OLCR consisted of the average result of 20 scans obtained within seconds. Additionally, corneal thickness was determined histologically after immersion fixation in Karnovsky’s solution alone (20 eyes) or with a previous injection of the fixative into the anterior chamber before enucleation (4 eyes). Results Central corneal thickness measurements using OLCR in 1‐day‐old living chicks provide a rapid and feasible examination technique. Mean CCT measured with OLCR (189.7 ± 3.34 μm) was significantly lower than histological measurements (242.1 ± 47.27 μm) in eyes with fixation in Karnovsky’s solution (P = 0.0005). In eyes with additional injection of Karnovsky’s fixative into the anterior chamber, mean histologically determined CCT was 195.2 ± 8.25 μm vs. 191.9 ± 8.90 μm with OLCR. A trend for a lower variance was found compared to the eyes that had only been immersion fixed. Conclusion Optical low‐coherence reflectometry is an accurate examination technique to measure in vivo CCT in the eye of newborn chicks. The knowledge of the thickness of the chick cornea and the ability to obtain noninvasive, noncontact measurements of CCT in the living animal may be of interest for research and development of eye diseases in chick models.  相似文献   