共查询到20条相似文献,搜索用时 15 毫秒
1.
The aims of this study were to establish a normal reference range (mean ± 2 SD) and assess reliability of renal dimensions obtained using transabdominal ultrasonography in Thoroughbred horses (n = 7). A minimum of three ultrasonographic cineloops were obtained from each intercostal space and the left paralumbar fossa by two observers daily for three consecutive days. Renal length, width, and thickness and cortex, medulla, and pelvic dimensions were obtained. Measurements were undertaken by both observers, who were unaware of prior measurements, to assess reproducibility and measured on three separate occasions to evaluate short-term measurement repeatability. Measurements from images obtained by both operators were compared to evaluate image repeatability. The left kidney was consistently identified in the left 15th-17th intercostal space and the paralumbar fossa with maximal length in the 16th intercostal space (12.7 ± 2.0 cm) and maximal width in the paralumbar fossa (7.9 ± 1.1 cm). The right kidney was consistently identified in the right 15th-17th intercostal space with maximal length and maximal width in the 15th intercostal space (16.0 ± 0.7 cm and 7.9 ± 1.0 cm). Reproducibility, image repeatability, measurement repeatability were good to excellent, although were less good for the smaller structures. There were no differences in renal dimensions between horses. Overall renal ultrasonography was reliable and a normal reference range for Thoroughbred horses was established. Renal dimensions vary between rib spaces. As repeatability and reproducibility were excellent for renal length and width, it may be prudent to use those measurements in rib spaces where parameters were maximal. 相似文献
2.
SONIA BITHELL JOCELYN L. HABERSHON‐BUTCHER I. MARK BOWEN GAYLE D. HALLOWELL 《Veterinary radiology & ultrasound》2010,51(6):647-651
The aims of this study were to assess the repeatability and reproducibility of transabdominal ultrasonography to assess intestinal wall thickness in adult Thoroughbred horses (n=8). Ultrasonographic cineloops were captured by one examiner from each horse for five consecutive days. During each examination at least three cineloops were obtained for five different intestinal tract locations. Measurements were performed by three separate observers to assess reproducibility and measured on three separate occasions by three observers to evaluate short‐term repeatability. The repeatability of measurements from the duodenum (0.3 ± 0.04 cm), jejunum (0.29 ± 0.05 cm), ventral colon (0.37 ± 0.01 cm), and cecum (0.42 ± 0.03 cm) were good ( P >0.291). The reproducibility of measurements from the duodenum, jejunum, and ventral colon were good ( P >0.394). Reproducibility of measurement of the cecal wall was inadequate ( P =0.01), although the maximum difference between observers was 0.07 cm. It was possible to image all areas on all days, with the exception of the duodenum, which could not be imaged in one horse, on 1 day. Equine intestinal wall measurements are therefore repeatable and reproducible with the exception of reproducibility of the measurements of cecal wall. Although an accepted clinical technique, measurement of cecal wall thickness from intestinal ultrasound images in a clinical setting must be interpreted with care. 相似文献
3.
Anne A. Wooldridge DVM Thomas L. Seahorn DVM MS Jamie Williams MS DVM H. Wayne Taylor DVM Ph.D. Julian L. Oliver DVM Ph.D. Dae Young Kim DVM Thomas J. Vicek DVM 《Veterinary radiology & ultrasound》1999,40(4):361-364
A 2-year-old quarter horse gelding presented for evaluation of polyuria and polydipsia. Azotemia was detected on serum chemistry profile. Small, misshapen, hyperechoic kidneys with decreased corticomedullary demarcation, hydronephrosis, and a right nephrolith were noted ultrasonographically. The diagnosis of end-stage kidney disease and dysplasia was made histopathologically using ultrasound-guided biopsy. Two ureteroliths were found in the right ureter via cystoscopy, and a nephrolith was seen in the right kidney at necropsy. Clinical, ultrasonographic, and pathologic features of equine urolithiasis and renal dysplasia are discussed. 相似文献
4.
5.
Radiography has a limited role in the evaluation of the kidneys in foals and adult horses. Ultrasonography is the current method of choice for structural evaluation of the kidneys in horses as it provides additional information to standard serum chemistry and urinalysis evaluation. A variety of structural abnormalities have been identified in diseased equine kidneys with the use of ultrasound. Ultrasound guided renal biopsy is the preferred method for performing renal biopsy in the horse. The use of Duplex Doppler ultrasound may allow for the characterization of regional hemodynamics of the equine kidneys, but is currently an untapped method for evaluation of equine renal hemodynamics.
Radionuclide methods including scintigraphy and quantitative renal function measurement can be used to provide further information about equine renal function. Scintigraphy can provide structural and possibly functional information. Quantitative methods using radiopharmaceuticals can provide precise measurement of glomerular filtration rate and effective renal blood flow. This method is especially helpful in identifying acute renal failure and in guiding response to treatment.
All equine renal imaging techniques should be a supplement to the physical examination and standard laboratory tests. Additional diagnostic aids such as urinary tract endoscopy should also be considered in horses with hematuria, hydroureter, and suspected calculi. Taken together, all these modalities provide a through evaluation of the equine renal system and provide a basis for the clinician to select treatment options and provide prognostic information to the owner. 相似文献
Radionuclide methods including scintigraphy and quantitative renal function measurement can be used to provide further information about equine renal function. Scintigraphy can provide structural and possibly functional information. Quantitative methods using radiopharmaceuticals can provide precise measurement of glomerular filtration rate and effective renal blood flow. This method is especially helpful in identifying acute renal failure and in guiding response to treatment.
All equine renal imaging techniques should be a supplement to the physical examination and standard laboratory tests. Additional diagnostic aids such as urinary tract endoscopy should also be considered in horses with hematuria, hydroureter, and suspected calculi. Taken together, all these modalities provide a through evaluation of the equine renal system and provide a basis for the clinician to select treatment options and provide prognostic information to the owner. 相似文献
6.
H. J. CHALMERS J. CHEETHAM A. E. YEAGER N. G. DUCHARME 《Veterinary radiology & ultrasound》2006,47(5):476-481
Nasopharyngeal and laryngeal evaluation is important when examining horses with upper airway signs for poor performance. Currently endoscopy is the most common method to evaluate the equine upper airway. Ultrasonography of the equine larynx has not previously been described. Using six cadaveric specimens and four standing horses, the ultrasonographic appearance of the equine larynx was established. A scanning technique, including useful acoustic windows and the normal ultrasonographic appearance at each site, is described. Ultrasound allowed visualization of portions of the hyoid apparatus, laryngeal cartilages, associated soft tissues, and intrinsic and extrinsic laryngeal musculature, that are not seen using endoscopy. Additionally, real-time ultrasound allowed observation of the movement of the vocal folds and the arytenoid cartilages during respiration. In three horses with arytenoid chondritis, ultrasonography aided in the diagnosis and localization of arytenoid abcessation and perilaryngeal inflammation. The establishment of this technique will serve as the basis for future investigations in the evaluation of clinical patients with upper airway abnormalities. 相似文献
7.
KELLY L. CARLSON M. KEITH CHAFFIN WAYNE V. CORAPI KAREN F. SNOWDEN DAVID G. SCHMITZ 《Veterinary radiology & ultrasound》2011,52(5):568-572
The starry sky hepatic pattern is an unusual ultrasonographic appearance of equine liver characterized by numerous small, hyperechoic foci, some of which cast an acoustic shadow, distributed randomly throughout the hepatic parenchyma. Our objectives were to describe the signalment, clinical signs, clinicopathological findings, primary disease process, and ultrasonographic findings of horses with this ultrasonographic pattern, as well as determine the associated gross and histologic changes. The starry sky pattern was identified in 18 adult horses of mixed gender and breed. The horses had various clinical signs, with weight loss and anorexia reported most commonly. Liver size and parenchymal echogenicity were normal in most horses. The hyperechoic foci frequently caused acoustic shadowing. Biliary dilation was noted rarely. The ultrasonographic pattern was the result of numerous fibrosing hepatic granulomas in all horses evaluated histologically. γ‐Glutamyltransferase was the most commonly elevated hepatic enzyme, though it was increased in fewer than half the horses. Fifteen horses had an additional disease that was identified as the apparent cause of clinical signs. Three horses had primary hepatic disease while 12 had diseases of other body systems. Therefore, the starry sky ultrasonographic pattern is likely incidental in most horses and not clinically significant. Improved recognition of this pattern and further investigation of affected horses may help refine the etiology and clinical significance of the granulomas. 相似文献
8.
9.
Laryngoplasty is commonly used to treat laryngeal hemiplegia in Thoroughbred racehorses. Evaluation of the success of the laryngoplasty is traditionally determined using endoscopy. Laryngeal ultrasonography and normal ultrasonographic appearance have been reported in the standing horse, but post‐laryngoplasty and ventriculectomy ultrasonographic evaluation has limited literature coverage. A prospective case series of 10 Thoroughbred racehorses with left laryngeal hemiplegia was examined ultrasonographically and endoscopically prior to 3‐10 days, 30‐50 days, and 6‐12 months after laryngoplasty and ventriculectomy. Anatomical structures and Plica vocalis movements were described and measurements and gradings analyzed by repeated means analysis of variance (P < .05). Postsurgical ultrasonographic visualization of Ventriculus laryngis entrances was possible. The distance between Plica vocalis in exhalation was significantly larger than that during inhalation (P < .05). Pre‐ and postsurgical caudal Basihyoideum and rostral Cartilago thyroidea depth was significantly different in some instances (P < .05). No significant differences in the Muscularis cricoarytenoideus lateralis measurements were found. Complications in the extra‐luminal structures were found in seven horses including soft tissue swelling, seroma, and hematoma. A luminal Plica vocalis abscess and Plica vocalis granuloma were also detected ultrasonographically. Ultrasonography can be used to evaluate the post‐laryngoplasty horse for assessing the success of the procedure, monitoring healing, and detecting complications. 相似文献
10.
Meghann Lustgarten W. Rich Redding Raphael Labens Weston Davis Thomas M. Daniel Emily Griffith Gabriela S. Seiler 《Veterinary radiology & ultrasound》2015,56(6):670-679
Compression elastography is an ultrasonographic technique that estimates tissue strain and may have utility in diagnosing and monitoring soft tissue injuries in the equine athlete. Recently, elastography has been proven to be a feasible and repeatable imaging modality for evaluating normal tendons and ligaments of the equine distal forelimb. The purposes of this prospective study were to investigate the ability of elastography to detect spontaneously occurring lesions of equine tendons and ligaments diagnosed with magnetic resonance imaging (MRI) and gray‐scale ultrasound (US) and to characterize the differences in the elastographic appearance of acute vs. chronic injuries. Fifty seven horses with a total of 65 lesions were evaluated. Images were assessed quantitatively and qualitatively. Acute lesions were found to be significantly softer (P < 0.0001) than chronic lesions (P < 0.0001) and the stiffness of lesions increased with progression of healing (P = 0.0138). A negative correlation between lesion hypoechogenicity and softness was appreciated with more hypoechoic lesions appearing softer (P = 0.0087) and more hyperechoic regions harder (P = 0.0002). A similar finding occurred with increased signal intensity on short tau inversion recovery (STIR) and proton density (PD) MRI sequences correlating with increased softness on elastography (P = 0.0164). Using US and MRI as references, commonly encountered soft tissue injuries of the equine distal limb could be detected with elastography. However, elastography was limited for detecting small, proximal injuries of the hindlimb proximal suspensory ligament. Elastographic evaluation of equine tendons and ligaments may allow better characterization of lesion chronicity and severity, and sequential examinations may optimize lesion management, rehabilitation, and return to training. 相似文献
11.
GEORGE A. HENRY DVM CLARK S. PATTON DVM MS DALLAS O. GOBLE DVM 《Veterinary radiology & ultrasound》1986,27(5):132-140
Iatrogenic lesions to the accessory ligament (carpal check or inferior check) and to the superficial digital flexor tendon of five ponies were monitored utilizing diagnostic ultrasound for a period of 6–24 weeks post-injury. The opposite limb was used as a non-surgical control. Sonographic differences from control limbs were recorded and correlated with the gross and microscopic post-mortem lesions. Early post-surgical sonographic findings included thickening with discrete hypoechoic areas within the injured tissues which corresponded to regions of hemorrhage, edema, and tissue disruption at necropsy. The linear hyperechoic pattern seen in normal tendons was disorganized in the injured portion of the tendons or ligaments. Disruption of the margins of the incised tissues was observed. The initial hypoechoic areas disappeared or decreased in size and became more echoic as healing progressed. The increasing echoic pattern in these areas corresponded to regions of fibrous tissues invasion and collagen deposition. As post-injury time increased, the size of the tendon or ligament decreased, the margins became more distinct, and the internal structure again became more organized (linear). It was concluded that diagnostic ultrasound can be useful in evaluating injury and healing of the accessory ligament and the superficial digital flexor tendon of horses. 相似文献
12.
Meghann Lustgarten W. Rich Redding Raphael Labens Michel Morgan Weston Davis Gabriela S. Seiler 《Veterinary radiology & ultrasound》2014,55(1):92-101
Tendon and ligament injuries are common causes of impaired performance in equine athletes. Gray‐scale ultrasonography is the current standard method for diagnosing and monitoring these injuries, however this modality only provides morphologic information. Elastography is an ultrasound technique that allows detection and measurement of tissue strain, and may provide valuable mechanical information about equine tendon and ligament injuries. The purpose of this study was to determine the feasibility, reproducibility, and repeatability of elastography; and to describe elastographic characteristics of metacarpal tendons in sound horses. Nineteen legs for 17 clinically sound horses without evidence of musculoskeletal pathology were included. Elastographic images of the superficial and deep digital flexor tendons and the branches of the suspensory ligament (tendon of the interosseous muscle) were described quantitatively and qualitatively. There was no statistically significant difference between operators (P = 0.86) nor within operators (P = 0.93). For qualitative assessments, reproducibility (0.46) was moderate and repeatability (0.78) was good. Similar to human Achilles tendons, equine tendons were classified as predominantly hard using elastography. There was no statistically significant difference in stiffness of the flexor tendons (P = 0.96). No significant difference in stiffness was found with altered leg position during standing (P = 0.84) and while nonweight bearing (P = 0.61). The flexor tendons were softer when imaged in longitudinal versus transverse planes (P < 0.01) however, the suspensory branches were not (P = 0.67). Findings supported future clinical application of elastography as a noninvasive “stall‐side” imaging modality for evaluation of the tendons and ligaments of the distal forelimb in horses. 相似文献
13.
The transrectal ultrasonographic appearance of the lumbosacral joint was assessed in 43 horses with no history or clinical evidence of back pain or hindlimb lameness. In the majority of horses (34/43, 79.1%) the lumbosacral disc had uniform or mildly heterogeneous echogenicity. However, variation in the ultrasonographic appearance of the lumbosacral joint was also identified, including hyperechogenic regions within the lumbosacral disc with or without an acoustic shadow, and mild or moderate irregularity of the opposing surfaces of the last lumbar and the first sacral vertebral bodies. Marked irregularity of the bony surfaces or marked disruption of the lumbosacral disc was not seen in any horse. The mean distance between the ventral aspects of the last lumbar and first sacral vertebrae was 14.2 mm (range: 7.1–26.5 mm, median: 14.4 mm). The degree of protrusion of the ventral aspect of the lumbosacral disc ranged from 0 to 5 mm (mean: 1.32 mm, median: 1.2 mm). The mean angle between the ventral surfaces of the last lumbar and first sacral vertebrae was 147° (range: 118–165°, median: 150°). There was no significant effect of age, breed, gender, or the size of the horses on either subjective findings in the lumbosacral joint or objective measurements. 相似文献
14.
Clinical diagnosis of renal tumors in the horse has been difficult because the traditional diagnostic techniques are inadequate. Because of this shortcoming, early publications rarely reported antemortem diagnosis of primary renal tumors. Conventional radiographic techniques cannot effectively outline kidneys in the adult horse. With the advent of ultrasonography, a new dimension to the evaluation of the large-animal kidney has been introduced. Percutaneous diagnostic ultrasonography provides a noninvasive method of examining both kidneys. This report describes a 15 year-old Tennessee Walking Horse mare presented for evaluation of a mass in the sublumbar region, polyuria and polydipsia. Clinical examination and laboratory test results suggested intra-abdominal neoplasia. Two-dimensional ultrasonographic images of the mass were consistent with renal neoplasia. Histologic diagnosis of ultrasound-guided renal biopsy was renal tubular cell carcinoma. 相似文献
15.
16.
Jeffrey R. Crass MD Ronald L. Genovese VMD James A. Render DVM Errol M. Bellon MD 《Veterinary radiology & ultrasound》1992,33(4):206-216
Ultrasonography and MRI have become valuable tools for imaging of tendon injuries. The current study examines the histopathologic basis for the imaging abnormalities. Five injured equine forelimbs and two normal contralateral limbs were studied with high resolution real time ultrasound and MRI. Histologic sections were made and correlated with the diagnostic images. All lesions were readily seen by both modalities. Lesions characterized by hemorrhage, edma, and cellular infiltration were sonolucent on ultrasound and bright on MRI images. MRI returned to normal as fibrogenesis ensued. Ultrasound images remained abnormal until fibrillar reallgnment occured with completion of the healing process. High resolution real time ultrasound and MRI both accurately reflect the tissue abnormalities in acute tendon injuries. The injured horse does appear to be an effective model for correlative imaging studies of tendon injuries. 相似文献
17.
Gareth H. Spurlock DVM MS Shauna L. Spurlock DVM MS George A. Parker DVM 《Veterinary radiology & ultrasound》1989,30(4):184-188
Collagenase-induced lesions of the superficial digital flexor tendon were monitored using diagnostic ultrasound and subsequently compared with gross and microscopic findings. The postinjury sonograms demonstrated hypoechoic or anechoic areas corresponding to areas of hemorrhage and necrosis. The size of the lesion increased and the echogenicity decreased with increasing units of collagenase injected into the tendon. As postinjury time increased, echogenicity increased, which corresponded to fibrous-tissue invasion and collagen deposition. The extent of tendon injury produced correlated with the amount of collagenase injected into the tendon. Diagnostic ultrasound is useful in evaluating injury and healing in collagenase— induced tendinitis. 相似文献
18.
The purpose of this study was to describe ultrasonographic changes of the equine palmar metacarpal area attributed to the infiltration of local anesthetic solution and to determine whether these changes were noted immediately or at 24 h. The palmar metacarpal region of one forelimb in each of six horses was examined ultrasonographically with a 10-MHz linear array transducer and a 7.5-MHz curvilinear transducer. Transverse and longitudinal images were recorded at 5-cm intervals distal to the accessory carpal bone. High and low palmar and palmar metacarpal nerve blocks were performed with a 2% mepivacaine hydrochloride solution. Ultrasonographic examinations similar to the initial examination then were performed immediately, 1 h and 24 h postinjection. Cross-sectional area and mean pixel value were determined for the superficial and deep digital flexor tendons, the accessory ligament of the deep digital flexor tendon, the suspensory ligament, and the suspensory branches at each level and time period. Subjective ultrasonographic changes also were noted. No significant difference was noted in the cross-sectional area or mean pixel value of any structure at any level or time period compared to baseline. Subjective changes in the tendons and ligaments were not noted. There was mild hypoechoic swelling of the surrounding soft tissues and gas in the region of the injections. Gas could interfere with the evaluation of the origin of the suspensory ligament and the proximal portion of the accessory ligament of the deep digital flexor tendon within the first hour but was not detectable ultrasonographically at 24 h. Based on these findings, if gas interferes with an ultrasonographic examination performed temporally close to perineural anesthesia, a repeat examination at 24 h is recommended. 相似文献
19.
Kate Alexander DMV Howard Dobson BVM & SC DVSC 《Veterinary radiology & ultrasound》2003,44(4):456-464
A study of the ultrasonographic appearance and size of the sciatic, tibial, peroneal, suprascapular, radial, median, and ulnar nerves and a comparison with the anatomic size and location of these nerves in the normal adult horse is reported. Cadavers and live horses were studied. Landmarks for localization and techniques for nerve identification are described. The depth and diameter of each nerve at various locations and the success rate in imaging each nerve are reported. Statistically significant correlations were found between anatomically and ultrasonographically measured nerve depths and diameters. The success rate in identifying nerves was 70% in the live horses and 49% in cadavers, with the deep peroneal nerve being the easiest to identify. Some applications of this technique in horses are discussed. 相似文献
20.
N.M. Werpy J.M. Denoix C.W. McIlwraith D.D. Frisbie 《Veterinary radiology & ultrasound》2013,54(5):536-547
Previous studies have proposed that standard ultrasonography may not adequately represent the pertinent anatomic characteristics of the equine proximal suspensory ligament. The purpose of the study was to compare the use of standard ultrasonography, angle contrast ultrasonography, MRI, and histology for identification of the anatomic characteristics of the normal equine suspensory ligament in the forelimb. Horses free from forelimb lameness with no palpable abnormalities in the region of the suspensory ligament were included in the study. The proximal suspensory ligaments in 20 forelimbs were examined using the standard ultrasound technique, angle contrast ultrasound technique, and MRI, followed by histologic evaluation. Total transverse (cross‐sectional) area of the proximal suspensory ligament was estimated using the standard ultrasound and the angle contrast ultrasound techniques, MRI, and histologic sections for the following parameters: total area of the ligament, ligament fibers, muscle, and fat. The proximal suspensory ligament lobe size and tissue distribution were compared and subjectively graded (0–4) for asymmetry. Subjectively, angle contrast ultrasound technique improved differentiation of fibers from the remaining tissue types and allowed identification of the peripheral ligament margin. There was no significant difference in asymmetry scores between modalities. The asymmetry scores of the right and left forelimbs were significantly different with both ultrasound and MRI, based on the level of measurement. The angle contrast ultrasound technique has limitations compared to MRI. However, it provides additional diagnostic information that is not available with the standard ultrasound technique. 相似文献