首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
OBJECTIVE: To describe a modified 3-loop pulley suture pattern for the reattachment of canine tendons to bone along with a biomechanical comparison with the locking-loop suture. STUDY DESIGN: In vitro biomechanical study and clinical case report. ANIMALS OR SAMPLE POPULATION: Biomechanical study: 10 paired gastrocnemius tendons and calcaneii harvested from 5 canine cadavers. Case report: a Doberman with avulsion of the gastrocnemius tendon of insertion. METHODS: Biomechanical study: paired tendons were reattached to the calcaneus with either a modified 3-loop pulley pattern or a locking-loop pattern. Tensile loading to failure was performed. A direct, non-contact, method of gap measurement, using digital video, was used to measure gap formation. Load required to initiate gap formation (defined as load at a 1 mm gap) and to produce a 3 mm gap was evaluated in addition to maximum load and gap at failure. RESULTS: Mean (+/-SEM) 1 mm gap loads were 31.0+/-4.2 and 17.2+/-2.5 N, mean 3 mm gap loads were 49.1+/-2.4 and 28.9+/-3.2 N, and mean maximum loads were 72.9+/-4.3 and 55.8+/-2.2 N for the modified 3-loop pulley suture and the locking-loop suture, respectively. These differences were statistically significant (P<.05). The gap at failure was similar for both repairs. The clinical case remained sound 7 months postoperatively. CONCLUSIONS: A modified 3-loop pulley pattern is biomechanically superior to a locking-loop pattern for reattachment of the canine gastrocnemius tendon to bone and may be suitable for clinical use. CLINICAL RELEVANCE: Tendon repairs with a gap >3 mm are reported to be at increased risk of rupture during the first 6 weeks postoperatively. A modified 3-loop pulley pattern resists gap formation better than a locking-loop pattern.  相似文献   

2.
Size 3-0 polydioxanone was used as a single strand, single braid (3 strands), or double braid (6 strands) to create six suture material-pattern combinations for equine tenorrhaphy: single-strand locking loop, single-braid locking loop, double-braid locking loop, single-strand three-loop pulley, single-braid three-loop pulley, and double-braid three-loop pulley. Maximum load to failure for the single-strand locking loop (46.1 +/- 2.9 newtons [N]) was less than for all other sutures (range, 103-155 N). The load required to form a 2 mm gap between tendon ends was greater for the single-braid three-loop pulley (66.7 +/- 6.9 N) and double-braid three-loop pulley (85.4 +/- 17.7 N) than any other sutures. The load required to produce a 10 mm gap was least for the single-strand locking loop (34.3 +/- 3.9 N) and greatest for the double-braid three-loop pulley (131.5 +/- 27.5 N). Gap between tendon ends at maximum load was greater for the single-braid (18.1 +/- 0.9 mm) and double-braid (19.2 +/- 2.2 mm) locking loops than for any other sutures. Suture material broke in 53% of the locking-loop tests but in only 17% of the three-loop pulley tests. Tendon matrix disruption accounted for 43% of the locking-loop failures and 77% of the three-loop pulley failures. The three-loop pulley pattern provided more support, less tendon distraction, and less tendon matrix constriction and distortion than the locking-loop pattern.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
OBJECTIVE: To compare pullout strength of 3 suture patterns used for canine tracheal anastomosis. STUDY DESIGN: Experimental study. SAMPLE POPULATION: Cadaveric canine tracheae (n = 20). METHOD: Tracheal segments were anastomosed with 1 of 3 suture patterns: simple continuous, simple interrupted, and simple interrupted reinforced with horizontal mattress, each encircling annular cartilage rings adjacent to the transection site. Horizontal mattress sutures encircled the annular rings proximal and distal to the rings closest to the anastomosis. Each construct was distracted (0.5 mm/s) in a materials testing machine to failure. Load-displacement curves were generated and failure load (pullout strength) determined and mode of failure recorded. RESULTS: Tracheal anastomosis with a simple interrupted pattern was significantly weaker (mean+/-SD pullout strength, 102.55+/-30.14 N) than simple continuous (135.53+/-15.47 N) or simple interrupted plus horizontal mattress (132.39+/-21.46 N), which were not different from each other. Mode of failure was consistently by suture tear out. CONCLUSIONS: Both simple continuous and simple interrupted reinforced with horizontal mattress suture patterns have significant biomechanical advantage over a simple interrupted pattern alone in canine cadaveric tracheal anastomosis. The simple continuous pattern had the least variability in pullout strength. CLINICAL RELEVANCE: A simple continuous technique should be considered when selecting a tension-relieving pattern for canine tracheal anastomosis. It offers the same biomechanical advantage as a simple interrupted pattern reinforced with a horizontal mattress pattern and its strength appears to be reliably maintained when tested in canine cadaver tracheae.  相似文献   

4.
The locking loop tendon suture is demonstrated. Five cases of its use in both acute and chronic lacerations of the calcanean tendon are presented. The results in all five cases were excellent. Advantages of this suture pattern include preservation of the intrinsic blood supply of the tendon, gap formation produced only with extreme load, simple and rapid placement of the suture, and reduction in adhesions. This suture pattern also can be used for other tendons.  相似文献   

5.
OBJECTIVE: To compare a 3-loop pulley suture pattern with 2 locking-loop sutures for the repair of components of the canine Achilles mechanism. STUDY DESIGN: In vitro biomechanical study. ANIMALS: Forty-eight paired tendons collected from 9 canine cadavers. METHODS: Paired tendons were repaired with either a 3-loop pulley suture or 2 locking-loop sutures and tensile tested to failure. To ensure accurate anastomosis gap measurement a direct, non-contact, method of gap measurement, using digital video, was devised. Load initiating gap formation (defined as load at a 1 mm gap) and load producing a 3 mm gap were evaluated in addition to maximum load, gap at failure, mode of failure, and time spent placing the sutures. RESULTS: Maximum load values were similar for both repairs. The mean 1 mm gap loads were 44.0 and 18.4 N, and the mean 3 mm gap loads were 56.3 and 34.7 N, for the 3-loop pulley pattern and the 2 locking-loops, respectively; these differences were statistically significant. The 3-loop pulley pattern was faster to place and resulted in a smaller gap at failure. All but 2 repairs failed by suture pull out. CONCLUSIONS: The 3-loop pulley pattern is more resistant to gap formation during tensile loading, and is quicker to place, than 2 locking-loop sutures. CLINICAL RELEVANCE: Gap formation can significantly delay tendon healing. Tendon repairs with a gap >3 mm are reported to be at increased risk of rupture during the first 6 weeks postoperatively.  相似文献   

6.
OBJECTIVES: To compare suture patterns (simple interrupted, modified pulley, horizontal mattress, double butterfly) by use of a novel in vitro model that quantifies force required for closure against tension. STUDY DESIGN: In vitro study. SAMPLE POPULATION: Suture constructs. METHODS: An in vitro suturing frame was constructed with extension springs to provide a standard resistance against movement of 2 panels of loops toward each other. Four different suture patterns were applied to the frame in randomized trials. The frame was affixed to a tensiometer that measured the force required for each suture pattern to close a fixed distance (3.81 cm) at a constant rate (5.08 cm/min) against the tension (0.6 kg/cm) of the extension springs. The closure distance and tension were selected subjectively to mimic tension encountered clinically during wound reconstruction oncologic surgical procedures. RESULTS: The modified pulley suture required the least force to close, followed by the double butterfly, simple interrupted, and horizontal mattress patterns. CONCLUSIONS: The modified pulley suture and double butterfly suture patterns require less force to close a given distance under tension than either simple interrupted or horizontal mattress suture patterns. CLINICAL RELEVANCE: Application of tension relieving suture techniques for fascia, subcutaneous, and buried-knot subdermal suturing should be considered to facilitate direct closure of wounds under tension. Modified pulley and double butterfly suture patterns offer some mechanical advantage by requiring less force to achieve closure compared with other suture patterns that might be used in reconstructive surgery.  相似文献   

7.
Development of ischemia in healing tendons was assessed in 18 rabbits. One superficial digital flexor tendon in each rabbit was incised and anastomosed using a Bunnell pattern. The repair site was enclosed in a porous, woven Dacron tube before skin closure. The limb was immobilized with a cast. Rabbits were euthanized 1, 4, and 8 weeks after surgery, and tendons were harvested and examined microscopically. Regions of the tendon included in the suture pattern were ischemic and acellular at 1 week, while adjacent areas still containing patent vessels remained viable. Within 4 weeks, a well vascularized neotendon with collagen bundles organized parallel to the long axis of the tendon developed along the periphery and between the opposed tendon ends. After 8 weeks, the ischemic regions of the tendon had not revascularized or become integrated with the neotendon. Adjacent collagen bundles not originally included in the Bunnell pattern were integrated with neotendon collagen fibers.  相似文献   

8.
This study compares the healing of oronasal defects created by partial maxillectomy when closed using two different suture materials and two different suture patterns. In experiment 1, 24 dogs were divided into four equal groups. Partial maxillectomy was performed on each dog and was closed using either a two-layer simple interrupted suture pattern (12 dogs) or a modified Mayo mattress pattern (12 dogs) with either polyglactin 910 (12 dogs) or polypropylene (12 dogs) sutures. On the seventh postoperative day, the dogs were euthanized, suture line bursting pressures were measured, and wound healing was evaluated grossly and histopathologically. Suture line dehiscence occurred in one dog from each of the four groups. These were the only dogs in which electrocoagulation had been used. The healing of suture lines closed with the two-layer simple interrupted pattern was superior to that of those closed with the modified Mayo mattress pattern based on the degree of gross oral ulceration, suppurative inflammation, fibrosis and oral epithelial covering at the suture line, and the number of necrotic sites in the adjacent tissue. The healing of suture lines closed with polypropylene was superior to that of those closed with polyglactin 910 based on suture line bursting pressures and the degree of suppurative inflammation and tissue necrosis at the suture sites. In Experiment 2, partial maxillectomies were performed on four dogs, and closure was achieved using a two-layer simple interrupted suture pattern with either polyglactin 910 (two dogs) or polypropylene (two dogs). On the 30th postoperative day, the dogs were euthanized, and wound healing was evaluated grossly and histopathologically. All suture lines were well healed. All polyglactin 910 oral sutures were absent, while all polypropylene oral sutures were still present.  相似文献   

9.
Esophagotomies were performed on 36 dogs and closed with 3-0 polydioxanone in double-layer simple interrupted, single-layer simple interrupted, or single-layer simple continuous patterns. The operative time was shortest for single-layer simple continuous closure, followed by single-layer simple interrupted and double-layer simple interrupted, respectively. Three dogs with each suture pattern were euthanatized at hours 0 and 1, and days 4 and 28 after surgery. The esophagotomy incisions were subjected to bursting strength testing and examined microscopically. The bursting wall tension was higher for all three suture pattern groups at 28 days than at 0 and 1 hour. The double-layer closure had higher bursting wall tension than the single-layer closures at 0 hour and 4 days. Single-layer simple continuous closure had the lowest bursting wall tension for each time period. Single-layer simple interrupted closure had the highest bursting wall tension at 28 days. Microscopic examination revealed close approximation of tissue planes for the double-layer closure and mucosal ever-sion for the simple interrupted and simple continuous single-layer closures. Healing was superior histologically with the double-layer closure.  相似文献   

10.
OBJECTIVE: To compare ease of insertion, load to failure, and mode of failure of cortical and cancellous screws, BoneBiter, IMEX, and TwinFix suture anchors in canine metaphyseal tibial bone. STUDY DESIGN: Experimental biomechanical study. ANIMALS: Canine cadaveric tibias. METHODS: One investigator inserted all anchors and subjectively evaluated ease of placement. Anchor systems were loaded to failure along axis of insertion with audio-video recording to determine failure mode. RESULTS: BoneBiter was the most difficult anchor to insert successfully. Mean+/-SD loads to failure were cancellous screw (711+/-193 N), IMEX 4.7 mm 18 g wire (661+/-163 N), IMEX 4.0 mm 18 g wire (661+/-165 N), cortical screw (635+/-184 N), BoneBiter #5 Kevlar suture (393+/- 109 N), and TwinFix 5.0 mm #2 polyester (267+/-73 N). No significant differences were noted among the cortical screw, cancellous screw, IMEX 4.7 and 4.0 mm, all of which were significantly (P<.001) greater than BoneBiter and TwinFix . Failure modes were pullout of bone, suture-wire breakage, eyelet breakage, or no failure to 1000 N: screws (18,0,0,2), IMEX (18,1,1,0), BoneBiter (2,8,0,0), and TwinFix (0,10,0,0). CONCLUSIONS: Fixation devices were user friendly, with the exception of BoneBiter. Mode of failure is dependent on suture material and anchor design. Cortical and cancellous screws, and IMEX anchors with 18 g wire have significantly greater load to failure compared with BoneBiter and TwinFix suture anchors. CLINICAL RELEVANCE: Based on load to failure, ease of use, design characteristics, and cost, IMEX anchors may have advantages over other comparable soft tissue fixation devices.  相似文献   

11.
OBJECTIVE: To describe the healing characteristics of deep digital flexor tenorrhaphy within the digital sheath. STUDY DESIGN: Experimental study. ANIMALS: Five mature horses. METHODS: Right thoracic limb, deep digital flexor tenorrhaphy was performed within the digital sheath. Limbs were cast in partial flexion using a short limb cast for 6 weeks. Next, extended heel shoes were used for limb support for 14 weeks. Healing was evaluated by sequential ultrasonographic examinations, and limb use was evaluated by force plate analysis. At 26 weeks, mechanical strength and morphologic characteristics of the repair site were evaluated. RESULTS: Gap (mean, 0.93 cm.) formation was evident in unloaded limbs at 3 weeks. This increased markedly by 6 weeks and was 5 cm at 26 weeks. Demarcation between the deep and superficial flexor tendons decreased as the transected ends adhered to the dorsal surface of the superficial flexor tendon. The intrathecal space was reduced by fibrous tissue. Mean maximum load to failure of the repair tissue was 4,616 +/- 3,556 N, with a mean stress of 12.99 +/- 2.78 MPa. The repair consistently failed at the adhesion between the transected tendon and the superficial flexor tendon. CONCLUSIONS: Intrathecal tenorrhaphy with external coaptation (in partial limb flexion) for 6 weeks resulted in gap healing, fibrous adhesion between the deep and superficial flexor tendons, fibrous tissue reduction of the intrathecal space, and a pasture-sound horse at 26 weeks. CLINICAL RELEVANCE: Without improved methods for immobilizing the deep digital flexor tendon, intrathecal tenorrhaphy is unlikely to result in first intention tendon healing.  相似文献   

12.
OBJECTIVE: To compare 3 techniques for ureteroneocystostomy in cats. STUDY DESIGN: Experimental surgical study. ANIMALS: Fifteen adult cats. METHODS: Cats (15) had ureteroneocystostomy with ureteronephrectomy of the contralateral kidney: 5 cats had an intravesical mucosal apposition technique (modified Leadbetter-Politano; intravesical-MA group), 5 cats had extravesical ureteroneocystostomy (modified Lich Gregoir) using a simple continuous suture pattern (extravesical-SC group) and 5 cats had an extravesical technique using a simple interrupted suture pattern (extravesical-SI group). Renal function was evaluated by measuring serum creatinine concentration. Ultrasonographic assessment of the kidney and ureteroneocystostomy site was performed the day after surgery, twice weekly for 3 weeks and once weekly for the remainder of the study. Cats were euthanatized 50 days after surgery. The kidney and ureter removed at surgery, the remaining kidney, ureter, ureteroneocystostomy site, and bladder were examined histologically. RESULTS: Two extravesical-SC cats were euthanatized because of azotemia and uroabdomen, and 1 died acutely at day 4 for unknown reasons. In the intravesical-MA and extravesical-SI cats, the serum creatinine concentration increased after surgery, peaking at a mean (+/-SD) of 9.4+/-2.4 mg/dL and 4.9+/-3.3 mg/dL on day 3, and decreasing to 3.4+/-5.7 mg/dL and 1.5+/-0.4 mg/dL on day 7, respectively. The extravesical-SI technique was associated with consistently lower serum creatinine concentrations for the first week after surgery compared with the other techniques. The mean serum creatinine concentration was within the reference range in cats in the intravesical-MA and extravesical-SI groups by days 10 and 5, respectively. Renal pelvic dilatation occurred in all cats but resolved more rapidly in cats after extravesical techniques. There was no significant difference in serum creatinine concentrations or renal pelvic dilation between the intravesical-MA and extravesical-SI techniques. Bladder mass height at the anastomosis site was significantly larger and persisted for longer with intravesical-MA technique. CONCLUSION: An extravesical-SI technique is seemingly the choice for ureteroneocystostomy in cats with undilated ureters. Renal pelvic dilation on ultrasound examination should be expected after ureteroneocystostomy in cats. CLINICAL RELEVANCE: An extravesical ureteroneocystostomy technique using a simple interrupted pattern for anastomosis should be considered in cats undergoing renal transplantation.  相似文献   

13.
Three different suture patterns (simple interrupted, interrupted horizontal mattress, subcuticular) were placed in a full thickness incision (skin and body wall) of 18 goldfish (Carassius auratus). After 14 days all fish were euthanized using benzocaine solution. The tissue reactions were evaluated by gross visual inspection and histopathological examination. The superficial inflammatory reactions were graded on a scale from 0 (no inflammation) to 3 (severe inflammation). The inflammatory response in histological examination was graded on a scale from 0 (no inflammatory response or normal skin tissue) to 5 (severe inflammatory response and necrosis). The interrupted horizontal mattress induced a moderately severe to severe inflammatory response and necrosis (grades 4–5) but the subcuticular suture induced a very mild to mild inflammatory response (grades 0–1). The simple interrupted suture induced a moderate to moderately severe inflammatory response (grades 2–4). In conclusion, results showed that a subcuticular suture is the most appropriate to use in the closure of a full thickness body wall incision.  相似文献   

14.
OBJECTIVE: To test the failure strength and energy of 2 bioabsorbable implants applied to transected deep digital flexor tendons (DDFT) from adult horses. STUDY DESIGN: Ex vivo biomechanical experiment. SAMPLE POPULATION: Twelve pairs of deep digital flexor tendons harvested from the forelimbs of fresh equine cadavers. METHODS: Poly-L-lactic acid tendon plates were custom manufactured for application to the cylindrical surface of an adult equine deep digital flexor tendon. Twelve pairs of DDFTs were transected 2 cm distal to the insertion of the distal check ligament of the deep digital flexor tendon. One tendon of each pair was randomly selected for repair with a biodegradable plate or a 3-loop pulley method. Size 2 polydioxanone suture was used in both repairs. Repairs were tested in tension to failure, with peak force (PF) and total energy (TE) at repair failure recorded in Newtons (N) and Joules (J), respectively. A paired t-test was used for statistical evaluation with a significant level set at P< or = .05. RESULTS: Mean+/-SD PF for failure of plated tendons (1507.08+/-184.34 N) was significantly greater than for sutured tendons (460.86+/-60.93 N). TE was also significantly greater for failure of plated tendons versus sutured tendons. CONCLUSIONS: Plate fixation of transected cadaver DDFTs appear to have superior immediate failure strength than 3-loop pulley repairs. CLINICAL RELEVANCE: Whereas in vivo testing is required, a bioabsorbable tendon plate may provide initial increased strength to support tendon healing and decrease external coaptation requirements.  相似文献   

15.
OBJECTIVE: To describe and compare a simple continuous suture pattern with a simple interrupted pattern for enterotomy closure or end-to-end intestinal anastomosis. DESIGN: Retrospective study. ANIMALS: 58 dogs and 25 cats that underwent enterotomy or intestinal resection and anastomosis. PROCEDURE: Signalment, surgical procedure, suture pattern, suture material, confirmation of dehiscence, and follow-up were reviewed. Groups were compared by procedure (anastomosis or enterotomy) and by suture pattern. RESULTS: 57 animals underwent continuous closure; 26 had interrupted closure. Only polydioxanone or polypropylene suture materials were used. Overall, 81 (98%) animals had no signs of intestinal dehiscence and survived > 2 weeks. Two animals had confirmed dehiscence after foreign body removal, 1 of 57 (2%) after continuous closure, and 1 of 26 (4%) after interrupted closure. CLINICAL IMPLICATIONS: The simple continuous closure pattern is an acceptable alternative to simple interrupted closure for small intestinal anastomosis or enterotomy closure.  相似文献   

16.
The aim of this retrospective study was to describe the use of simple interrupted suture pattern for the closure of the abdomen after ventral midline celiotomy in horses and to evaluate the prevalence of resulting incisional complications. Seventy horses undergoing abdominal surgery (2006–2015) and surviving at least 30 days were included in the study. Closure technique of the abdominal wall was performed on three layers. Linea alba was closed with a simple interrupted pattern using number two coated braided absorbable polyglycolic acid suture. Follow-up information was recovered at the 90th day postoperatively. Incisional complications considered included drainage, infection, dehiscence, and herniation. The complications observed in the present study using simple interrupted suture pattern were 4.29% (3 of 70), lower than reported in literature with different suture pattern. Simple interrupted suture pattern could be a valid option for the closure of linea alba after ventral midline celiotomy in horses.  相似文献   

17.
Objective: To test single cycle to failure tensile strength characteristics of 6 suture material–pattern combinations in equine superficial digital flexor (SDF) tenorrhaphy, specifically to compare a 10‐strand modification of the Savage core suture technique with the 3‐loop pulley technique. Study Design: Ex vivo mechanical experiment comparing 3 different suture patterns with 2 different materials. Sample Population: Forelimb and hindlimb SDF tendons (n=48) harvested from adult Thoroughbred and Standardbred horses of mixed age and gender. Methods: Six suture material–pattern combinations were evaluated: (1) 10‐strand Savage, size 2 polydioxanone (PDS); (2) 10‐strand Savage, size 2 polyglactin 910 (PG910); (3) 10‐strand Savage, size 2 PDS with Lin‐locking epitenon suture, size 2–0 PDS; (4) 10‐strand Savage size 2 PG910 with Lin‐locking epitenon suture, size 2–0 PDS; (5) 3‐loop pulley, size 2 PDS; and (6) 3‐loop pulley, size 2 PG910. Maximum load at failure (N), gap at failure (mm), and mode of failure (suture breakage or pull through) were evaluated for each of the 6 suture material–pattern combinations and underwent statistical analysis to determine significance of differences and interactions of the measured data. Results: The 10‐strand Savage technique failed at a mean load of 872 N (804–939, 95% CI). The 10‐strand Savage with Lin‐locking failed at a significantly greater mean load of 998 N (930–1065, 95% CI). The 3‐loop pulley pattern failed with a mean load of 337 N (270–405, 95% CI). There were significant interactions between the technique and suture material used. Conclusion: The 10‐strand Savage technique for repair of transected cadaver SDF tendons has superior strength characteristics with or without the epitenon suture when compared to the 3‐loop pulley. Suture material and pattern interactions were observed with PG 910 conferring higher strength for the 10‐strand Savage whereas PDS did so for the 3‐loop pulley.  相似文献   

18.
OBJECTIVE: To determine a hand-tied ligature knot configuration, suture size, and suture type that would be an acceptable substitute to commercially available ligature knots for use in equine laparoscopic surgery. STUDY DESIGN: Three-factor ANOVA with the fixed effects being suture type, suture size, and knot type. The dependent variable was ligature security (load to failure). METHODS: Commercially available Endoloop and 4 hand-tied slipknot ligatures were compared with a 4-layer square knot. The hand tied ligature knots tested were the 4S modified Roeder knot, the Brooks knot, the modified Roeder knot, and the Weston knot. Two suture sizes (0, 2) of each of 2 suture types (polydioxanone, polyglactin 910) were tested with each hand tied knot. Two types (polydioxanone, polyglactin 910) of size 0 Endoloop were tested. Twenty repetitions of each knot suture type were tested for force to yield on a materials testing machine. Statistical analysis consisted of a 3-way ANOVA with individual comparisons made using the Bonferroni method. Significance was P< or = .05. RESULTS: Only the 4S modified Roeder knot in 2 polydioxanone (103 N) was comparable with the breaking strength of the square knots (157 N). All other knot suture combinations tested were significantly weaker than the square knot (range, 2-18 N). CONCLUSION: For equine laparoscopy, a 2 polydioxanone 4S modified Roeder knot would be an acceptable alternative to the commercially available Endoloop. CLINICAL RELEVANCE: Laparoscopic slip knots are commonly used in equine laparoscopic surgery. Various knot configuration and suture size and type combinations will affect the security of the slip knot.  相似文献   

19.
Dorsal cystotomies were performed in 60 healthy dogs. Twenty bladders were closed with a single-layer interrupted appositional suture pattern, 20 with a two-layer interrupted appositional suture pattern, and 20 with a two-layer continuous inverting suture pattern. Four dogs from each group were euthanatized at hours 0, 3, 12, 18, and 24. Mechanical strength of the cystotomy closures was evaluated by calculating the circular bursting wall tension. The single-layer interrupted appositional suture pattern was as strong as both two-layer suture patterns at hours 3, 12, 18, and 24. The two-layer interrupted appositional suture pattern was as strong as the two-layer continuous inverting suture pattern during the first 24 hours.  相似文献   

20.
The purpose of this study was to determine the biomechanical properties of feline long bone by testing cadaver bone from mature cats in compression, three-point bending, notch sensitivity and screw pull-out strength. The determination of these properties is of clinical relevance with regard to the forces resulting in long bone fractures in cats as well as the behaviour and failure mode of surgical implants utilized for fracture stabilization and repair in the cat. Cadaveric cat femurs were tested in compression, three-point bending and in three-point bending after the addition of a 2.0 mm screw hole. Cortical screws, 2.7 mm in diameter, were inserted in cadaveric cat femur samples for screw pull-out testing. The mean maximum load to failure of mid diaphyseal feline femurs tested in compression was 4201+/-1218 N. Statistical analysis of the parameter of maximum load tested in compression revealed a statistical difference between sides (p=0.02), but not location (p=0.07), or location by side (p=0.12). The maximum strength of mid diaphyseal feline femurs tested in compression was 110.6+/-26.6 MPa. The modulus of elasticity of mid-diaphyseal cat femurs tested in compression was determined to be 5.004+/-0.970 GPa. The mean maximum load to failure of feline femurs tested in three-point bending was 443+/-98 N. The mean maximum load to failure of feline femurs tested in three-point bending after a 2.0 mm diameter hole was drilled in the mid-diaphyseal region of each sample through both cortices was 471+/-52 N. The mean maximum load required for screw pull-out of 2.7 mm cortical screws placed in feline femurs tested in tension was 886+/-221 N. This data should be suitable for investigating fracture biomechanics and the testing of orthopaedic constructs commonly used for fracture stabilization in the feline patient.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号