首页 | 本学科首页   官方微博 | 高级检索  
     检索      

药品选择及径流水样存放时间对总氮测定的影响
引用本文:张丽君,罗旭辉,陈恩.药品选择及径流水样存放时间对总氮测定的影响[J].福建农业科技,2016(11):47-50.
作者姓名:张丽君  罗旭辉  陈恩
作者单位:福建省农业科学院农业生态研究所 350013
基金项目:福建省省属公益类科研院所基本科研专项(2017R1016-3)
摘    要:研究了国药集团、优耐德、Fluka的过硫酸钾药品以及水样存放时间对总氮含量测定的影响,结果表明:未经过提纯的3种药品均无法达到试验的要求,使用提纯后的Fluka过硫酸钾药品可达到总氮测定的要求;在-20℃环境下保持4个月径流水样总氮浓度无显著变化.

关 键 词:总氮  过硫酸钾  存放时间

Effects of drug selection and storage time of runoff-wateron total nitrogen determination
Abstract:Effects of potassium persulfate from Guoyao group, Younaide and Fluka, and storage time of runoff-water on total nitrogen determination were studied.The results showed that the 3 drugs without purification were unable to reach the requirements of total nitrogen determination but purified potassium persulfate of Fluka could.And the total nitrogen concentrations of runoff water keeping 4 month in-20℃ had no significantly changed.
Keywords:Total nitrogen  potassium persulfate  storage time
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号