首页 | 本学科首页   官方微博 | 高级检索  
     检索      

光学表面等离子共振测定盐酸克伦特罗的试验研究
引用本文:李会芹,李遂亮,李伟,江敏,魏文松,胡枫江,赵媛媛,胡建东.光学表面等离子共振测定盐酸克伦特罗的试验研究[J].河南农业大学学报,2012,46(2):198-202.
作者姓名:李会芹  李遂亮  李伟  江敏  魏文松  胡枫江  赵媛媛  胡建东
作者单位:1. 河南农业大学机电工程学院,河南郑州,450002
2. 河南农业大学理学院,河南郑州,450002
3. 河南农业大学生命科学学院,河南郑州,450002
基金项目:国家863计划项目,河南省杰出青年基金,河南省教育厅创新人才项目,郑州市科技领军人才项目
摘    要:为了实现高灵敏度定量检测盐酸克伦特罗,提出了一种新颖的、无标记、快速的内嵌TSPR1K23生物传感器的光学表面等离子共振(Surface plasmon resonance,SPR)盐酸克伦特罗测定方法,并通过试验验证了光学表面等离子共振生物测定装置的性能.光学表面等离子共振盐酸克伦特罗测定装置由集成光学SPR生物传感器、微流通池、便捷更换芯片的夹具、触电屏,USB接口板及光电转换电路板组成.在光学SPR芯片金膜表面固定盐酸克伦特罗抗原,在标准样品中(盐酸克伦特罗抗体质量浓度33.75 mg·L-1)分别添加0,10,20,40 mg·L-1的盐酸克伦特罗抗原,采用竞争免疫反应方法建立的盐酸克伦特罗测定标准曲线,相关系数0.997,相对标准偏差6.5%.

关 键 词:光学表面等离子(SPR)  盐酸克伦特罗  生物传感器  微流池

Experimental study on detection of clenbuterol hydrochloride using surface plasmon resonance
LI Hui-qin , LI Sui-liang , LI Wei , JIANG Min , WEI Wen-song , HU Feng-jiang , ZHAO Yuan-yuan , HU Jian-dong.Experimental study on detection of clenbuterol hydrochloride using surface plasmon resonance[J].Journal of Henan Agricultural University,2012,46(2):198-202.
Authors:LI Hui-qin  LI Sui-liang  LI Wei  JIANG Min  WEI Wen-song  HU Feng-jiang  ZHAO Yuan-yuan  HU Jian-dong
Institution:1(1.College of Mechanical and Electrical Engineering,Henan Agricultural University,Zhengzhou 450002,China;2.College of Sciences,Henan Agricultural University,Zhengzhou 450002,China;3.College of Life Sciences,Henan Agricultural University,Zhengzhou 450002,China)
Abstract:In order to realize a high sensitive quantitative detection of residual clenbuterol hydrochloride(CLB),an novel and label-free surface plasmon resonance(SPR) analytical approach based on the TSPR1K23 biosensor was systematically proposed,and validated experimentally for its high performance.This device is composed of an integrated biosensor,a micro-flow cell,a clamp,a touch monitor screen and an electrical control unit(ECU) incorporated with a photoelectric conversion board and a USB interface board.In this study,the measurement approach was validated using the clenbuterol hydrochloride surface antigen as an example.The antigen-CLB is immobilized to the surface of the biosensor chip by a self-assembly technology.The antigen-CLB samples at 0,10,20,40 mg·L-1 were respectively added into the standard solution of antibody-CLB(mass concentration 33.75 g·mL-1),and a fitting curve is obtained,which optimized with a R-squared value 0.997,RSD 6.5%.
Keywords:surface plason resonance  clenbuterol hydrochloride  biosensors  micro-flow cell
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号