首页 | 本学科首页   官方微博 | 高级检索  
     检索      

恒温恒湿检定系统日常维护与故障分析
引用本文:张佳佳,封皖.恒温恒湿检定系统日常维护与故障分析[J].安徽农业科学,2014(30):10487-10488.
作者姓名:张佳佳  封皖
作者单位:河北省气象技术装备中心,河北石家庄,050021
摘    要:简述了伟思富奇恒温恒湿箱以及与之配套使用的神荣露点仪日常维护与保养的注意事项,指出以预防故障为前提的日常维护工作的必要性.分析了设备可能出现的故障情况,并列举排除故障的方法和维修措施.

关 键 词:伟思富奇恒温恒湿箱  神荣露点仪  故障分析  维护维修

Routine Maintenance and Failure Analysis of Humidity Calibration System
ZHANG Jia-jia,FENG Huan.Routine Maintenance and Failure Analysis of Humidity Calibration System[J].Journal of Anhui Agricultural Sciences,2014(30):10487-10488.
Authors:ZHANG Jia-jia  FENG Huan
Institution:ZHANG Jia-jia, FENG Huan ( Meteorological Technical Equipment Center of Hebei Province, Shijiazhuang, Hebei 050021 )
Abstract:This paper describes the Humidity Chamber of Weiss voetsch and the SHINYEI dewpoint meter with supporting the use of daily care and maintenance precautions, points out the necessity to prevent failure is the prerequisite for routine maintenance work. Analysis of the failure of the equipment that may arise, and methods troubleshooting and repair measures are enumerated.
Keywords:Humidity Chamber of Weiss voetsch  SHINYEI dewpoint meter  Failure analysis  Maintenance and service
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号