首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Development of a sensitive and rapid method for the measurement of total microbial activity using fluorescein diacetate (FDA) in a range of soils
Institution:1. Brazilian Biorenewables National Laboratory (LNBR), Brazilian Center for Research in Energy and Materials (CNPEM), Campinas, 13083-970 Sao Paulo, Brazil;2. Department of Plant & Soil Sciences, University of Delaware, Newark, DE 19716 USA, USA;3. University of São Paulo, College of Agriculture “Luiz de Queiroz”, Soil Science Department, Av. Pádua Dias 11, Box 9, Piracicaba, 13418-900 Sao Paulo, Brazil;4. Brazilian Nanotechnology National Laboratory (LNNano), Brazilian Center for Research in Energy and Materials (CNPEM), Campinas, 13083-970 Sao Paulo, Brazil;5. Brazilian Synchrotron Light Laboratory (LNLS), Brazilian Center for Research in Energy and Materials (CNPEM), 13083-970, Campinas, Sao Paulo, Brazil;1. Instituto de Desarrollo Tecnológico para la Industria Química (INTEC, UNL-CONICET), 3000, Santa Fe, Argentina;2. RISE- Research Institutes of Sweden, Uppsala, S-750 07, Sweden;3. Dep. Medioambiente, FICH-UNL, Ciudad Universitaria, 3000, Santa Fe, Argentina;1. College of Natural Resources and Environment, Northwest A&F University, Key Laboratory of Plant Nutrition and Agro-environment in Northwest China, Ministry of Agriculture, Yangling, 712100, Shaanxi, China;2. Key Laboratory of Soil Environment and Pollution Remediation, Institute of Soil Science, Chinese Academy of Sciences, Nanjing, 210008, China;3. Key Laboratory of Vegetation Restoration and Management of Degraded Ecosystems, South China Botanical Garden, Chinese Academy of Sciences, 723 Xingke Rd., Tianhe District, Guangzhou, 510650, China;4. Global Centre for Environmental Remediation, Faculty of Science, University of Newcastle, Callaghan, NSW, 2308, Australia
Abstract:Fluorescein diacetate (FDA) hydrolysis is widely accepted as an accurate and simple method for measuring total microbial activity in a range of environmental samples, including soils. Colourless fluorescein diacetate is hydrolysed by both free and membrane bound enzymes, releasing a coloured end product fluorescein which can be measured by spectrophotometry. The current method for measuring FDA hydrolysis in soils is limited in its application. FDA activity was very low in sandy and clayey soils. The low activity observed for these soil types was made difficult to measure by the original authors’ choice of solvent for terminating the hydrolysis reaction. Acetone (50% v/v) was found to be most efficient at stopping the hydrolysis reaction. During this study acetone (50% v/v) was found to cause a decrease of approximately 37% in the absorbance of fluorescein produced by the soil samples measured. Although this colour loss is independent of initial fluorescein concentration, it makes the measurement of FDA hydrolytic activity extremely difficult in soils with low microbial activity i.e. sandy and/or clayey soils. Chloroform/methanol (2:1 v/v) was found to successfully stop the hydrolysis reaction for up to 50 min in a range of soil samples without causing the loss of colour observed with acetone. By changing the solvent used for terminating the hydrolysis reaction, low activity soils could be measured successfully. Other parameters of the hydrolysis reaction were optimised for the measurement of soil samples including effect of pH, optimum temperature of incubation, amount of soil, time of incubation, amount of substrate and preparation of suitable standards. A new, more sensitive method is proposed adapted from the original method, which provides a more accurate determination of FDA hydrolysis in a wide range of soils.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号