首页 | 本学科首页   官方微博 | 高级检索  
     检索      

单井循环地下水源热泵换热特性CFD模拟与验证
引用本文:宋伟,倪龙,姚杨.单井循环地下水源热泵换热特性CFD模拟与验证[J].农业工程学报,2015,31(24):201-206.
作者姓名:宋伟  倪龙  姚杨
作者单位:1.北方工业大学土木工程学院,北京 100144,2.哈尔滨工业大学市政环境工程学院,哈尔滨 150090,2.哈尔滨工业大学市政环境工程学院,哈尔滨 150090
基金项目:供热供燃气通风及空调工程北京市重点实验室研究基金资助课题;北方工业大学科研启动基金项目资助。
摘    要:针对单井循环地下换热系统CFD模拟研究的不足,建立了该系统多区域耦合的CFD模型用于研究其地下水流动和换热特性。结果表明,循环单井、抽灌同井和填砾抽灌同井CFD模型的抽水温度和含水层特征点温度模拟结果均与试验测试结果吻合较好,3种热源井25 min的累计取热量相对误差分别为12.1%、3.0%和8.2%。所建立的3种热源井CFD模型可以用于分析和预测实际单井循环地下换热系统中热源井特性、含水层流场和温度场的变化情况,并能提供较为准确的模拟数据。

关 键 词:水源热泵系统    热交换器  多区域耦合  CFD
收稿时间:2015/6/13 0:00:00
修稿时间:2015/11/5 0:00:00

CFD simulation and experiment of heat exchanger characteristic for single well cycling underground heat pump
Song Wei,Ni Long and Yao Yang.CFD simulation and experiment of heat exchanger characteristic for single well cycling underground heat pump[J].Transactions of the Chinese Society of Agricultural Engineering,2015,31(24):201-206.
Authors:Song Wei  Ni Long and Yao Yang
Institution:1. School of Civil Engineering, North China University of Technology, Beijing 100144, China;,2. School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China; and 2. School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China;
Abstract:Abstract: Ground source heat pump (GSHP) systems are considered as an ideal approach to heat and cool building, due to their attractive advantages of high efficiency, low carbon emission and using renewable energy instead of electricity for heating and cooling. Many of projects have been applied in residential and commercial buildings successfully. Single well groundwater heat pump (SWGWHP) systems are new member of GSHP system, which become increasingly popular for use because of their economic advantages. In general, SWGWHP systems included three different variations, i.e. standing column well (SCW) system, pumping & recharging well (PRW) system, and pumping & recharging well filled with gravel (PRWFG) system. Although there are some theoretical and experimental researches on SWGWHP systems, there are not many researches on Computational Fluid Dynamics (CFD) simulation about flow and thermal performance in these systems. CFD are well known for their capability to carry out in-depth analysis of fluid flow, heat transfer, mass transfer and several other related issues. They provide numerical solutions of partial differential equations governing fluid flow and heat transfer in a discretized form. CFD employs a very simple principle of resolving the entire system in small cells or grids and applying governing equations on these discrete elements to find numerical solutions regarding pressure distribution, temperature gradients and flow parameters in a shorter time at a lower cost. Meanwhile, CFD simulation has been widely used in research field of Heating, Ventilating and Air Conditioning (HVAC), such as indoor climate, horizontal and vertical ground heat exchanger, earth-to-air heat exchanger and so on. To examine the complicated characteristics of groundwater flow and heat transfer in thermal well and aquifer, CFD software FLUENT 14.5 was used in this study. In this analysis, the CFD simulation results were compared with experimental measurements. A good agreement was obtained between predicted outlet water temperature and aquifer characteristics temperature, thus confirming that the CFD model was successful in reproducing the flow and heat transfer processes in aquifer. The relative errors of three thermal wells in 25 min heat accumulation were 12.1%, 3.0% and 8.2%, respectively. Therefore, the establishment of these three thermal well CFD model can be used to analyze and predict the actual SWGWHP performance with the variation of groundwater flow field and temperature field, which can also provide accurate simulation data. This study suggested that the developed multi zone coupling CFD model can be useful tool in evaluating the flow and heat transfer performance. However, the established CFD simulation model can explain the complex flowed and heat transferred in porous media, CFD simulation in determining realistic initial conditions when attempting to model field conditions still remained a challenge. Further exploration of thermal well structure variations throughout the full range of climatic conditions is also needed.
Keywords:heat pump systems  wells  heat exchangers  multi-zone coupling  CFD
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《农业工程学报》浏览原始摘要信息
点击此处可从《农业工程学报》下载免费的PDF全文