首页 | 本学科首页   官方微博 | 高级检索  
     

水泵选型与运行模式对变频调速供
引用本文:樊建军,梁志君,董毅,崔艳堂. 水泵选型与运行模式对变频调速供[J]. 中国农村水利水电, 2007, 0(7): 25-27
作者姓名:樊建军  梁志君  董毅  崔艳堂
作者单位:1. 广州大学土木工程学院,广州,510006
2. 华南理工大学建筑设计研究院,广州,510641
基金项目:广东省自然科学基金;广州市高校科技项目
摘    要:从离心水泵工况分析入手,研究了变频调速恒压供水系统中水泵的适用性问题,给出了保证系统高效运行的水泵选型控制参数。在水泵选型和运行调度都合理时,变频调速供水系统才可取得预期的节能效果,小流量条件下需辅以气压给水技术节能。为充分利用高效率调速运行的流量区间,设定的工作压力应等于或略大于所选水泵高效区右端点的扬程。同型号水泵并联工作,只对1台水泵调速时,调速泵仍然存在小流量供水现象;设定工作压力下单泵最大供水量大于高效调速区间下限流量的2倍时,对2台水泵实施调速可避免水泵工况点偏离高效区。

关 键 词:变频调速供水  特性曲线  水泵工况  水泵效率  节能
文章编号:1007-2284(2007)07-0025-03
修稿时间:2006-08-15

Influence of Pump Type-Selection and Operating Mode on Energy-Consumption of Frequency-Conversion and Speed-Adjusting Water Supply System
FAN Jian-jun,LIANG Zhi-jun,DONG Yi,CUI Yan-tang. Influence of Pump Type-Selection and Operating Mode on Energy-Consumption of Frequency-Conversion and Speed-Adjusting Water Supply System[J]. China Rural Water and Hydropower, 2007, 0(7): 25-27
Authors:FAN Jian-jun  LIANG Zhi-jun  DONG Yi  CUI Yan-tang
Affiliation:1. School of Civil Eng., Guangzhou Univ., Guangzhou 510006; 2. Arch. Design Institute of South China Univ. of Tech. , Guangzhou 510641
Abstract:Based on the analysis of operation condition of centrifugal pumps, the applicability of frequency-conversion and speed-adjusting water supply system was studied, and main parameters for type-selection with high operation efficiently of the system were proposed. The expected energy-saving effect of the system could be obtained when the pumps were selected and operated reasonably, and the pneumatic tank should be used when water supply discharge is small. In order to take full advantage of the quantity range with higher efficiency, the given pressure should be equal to or slightly higher than the head of right end of characteristic performance curve in high efficient area. In the system of parallel connection of same type pumps and only one pump was controlled by frequency converter, the speed-varying pump may still operate inefficiently because of small quantity. If the maximal water supply quantity of one pump under given pressure is more than two times of the minimum water supply quantity in the high efficient range, pumps can operate without deviating from high efficient area by means of controlling two pumps with frequency converter.
Keywords:frequency-conversion and speed-adjusting water supply   characteristic performance curve   operation condition of pump   efficiency of pump   energy-saving