Pilot study of the practicability of a commercially-available Salmonella rapid test for the detection of the Salmonella content of cattle fecal samples |
| |
Authors: | A Weber F Enders |
| |
Institution: | Landesuntersuchungsamt für das Gesundheitswesen Nordbayern, Nürnberg. |
| |
Abstract: | 100 faeces samples of cattle were investigated in comparison to a recent commercially available Salmonella Rapid Test (OXOID) and a cultural standard method (non-selective enrichment in buffered peptone water, selective enrichment in RAPPAPORT-VASSILIADIS-medium) for presence of Salmonella. The Salmonella Rapid Test showed in positive results an accuracy ("sensitivity") of 94.7% and in negative results an assurance ("specificity") of 97.5% and is therefore suitable for rapid detection (within 2 days) of faeces sample of cattle with Salmonella. |
| |
Keywords: | |
|
|