1. Equine Department, University of Zurich, , Switzerland.;2. Section of Diagnostic Imaging, University of Zurich, , Switzerland.;3. Section of Anaesthesia, Vetsuisse‐Faculty, University of Zurich, , Switzerland.
Abstract:
A closed complete mid‐diaphyseal spiral fracture of the left femur in a one‐year‐old donkey was treated with a 4.5 mm titanium locking compression plate distal femur (LCP‐DF)1. This plate was originally manufactured for human orthopaedics, primarily for femoral osteosynthesis. The LCP‐DF1 has a distal head plate that was advantageous in this case because the distal fragment was smaller. Post operative radiographs showed optimal femoral reconstruction and a callus was present 3 weeks after surgery. The donkey was sound at the walk and trot 2 months after surgery. Radiographs taken 5 months after surgery showed stable implants and complete healing without complications.