首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Contrast harmonic imaging characterization of canine splenic lesions
Authors:Ohlerth S  Dennler M  Rüefli E  Hauser B  Poirier V  Siebeck N  Roos M  Kaser-Hotz B
Institution:Vetsuisse Faculty, University of Zurich, Section of Diagnostic Imaging and Radio-Oncology, Winterthurerstrasse, Zurich, Switzerland,;Department of Pathology, Winterthurerstrasse, Zurich, Switzerland,;Section of Small Animal Medicine, Winterthurerstrasse, Zurich, Switzerland;Department of Biostatistics, Institute of Social and Preventive Medicine, University of Zurich, Hirschengraben, Zurich, Switzerland
Abstract:Background: Although B-mode ultrasound is very sensitive for the detection of splenic lesions, its specificity is low. Contrast harmonic imaging is used successfully to differentiate benign from malignant liver lesions in humans and dogs.
Hypothesis: Contrast harmonic imaging could be useful to differentiate benign and malignant splenic lesions in dogs.
Animals: Sixty dogs (clinical patients) with splenic abnormalities detected during abdominal ultrasonography.
Methods: A prospective study was performed with a Philips ATL 5000 unit for contrast pulse inversion harmonic imaging (mechanical index: 0.08, contrast medium: SonoVue). Perfusion was assessed subjectively and quantitatively.
Results: Cytology or histology identified 27 benign (hyperplasia, extramedullary hematopoiesis, hematoma) and 29 malignant (hemangiosarcoma, malignant lymphoma, malignant histiocytosis, mesenchymal tumors without classification, mast cell tumors, and others) lesions and 4 normal spleens. Except for 1 benign nodule, extensive to moderate hypoechogenicity was only seen in malignant lesions during wash-in, at peak enhancement, and during wash-out ( P = .0001, odds ratios: 37.9 95% CI 4.5–316.5], 66.4 95% CI 8.0–551.1], and 36.9 95% CI 4.4–308.4]). Although all but 1 benign lesion enhanced well and were mildly hypo-, iso-, or hyperechoic in comparison with the normal spleen during all blood pool phases, marked enhancement occurred both in benign as well as in malignant splenic lesions. Quantitative perfusion values did not differ significantly between benign and malignant lesions.
Conclusions and Clinical Importance: Moderate to extensive hypoechogenicity clearly identifies canine splenic malignant lesions. In nodules with marked enhancement, contrast harmonic ultrasound is of limited value and histology is needed.
Keywords:Dog  Microbubble  Perfusion  Spleen  Ultrasound
本文献已被 PubMed 等数据库收录!